Relay TerminalG70D-SOC16/FOM16CSM G70D-SOC16 FOM16 DS E 1 1Compact, Low-profile 16-point Output terminal Compact terminal is just 156 51 39 mm (W D H) Models with Power MOSFET Relays are availablefor high-frequency switching of AC or DC loads. Wire loads directly from terminals; no need for relaying. Operation indicators show each I/O signal’sON/OFF status at a glance. The G70D-SOC16 and G70D-FOM16 can be combinedwith a DRT1-OD32ML I/O Terminal for DeviceNetconnectivity or an SRT2-VOD16ML Connector Terminalfor CompoBus/S connectivity. Equipped with surge-absorbing diodes. Relay Removal Tool included. Mount either to DIN rail or via screws.Ordering InformationRelay TerminalsClassificationPointsInternal I/O commonRated voltageNPN ( common)Relay outputs16 points (SPST-NO 16)Power MOSFET relay outputsModelG70D-SOC16PNP ( common)G70D-SOC16-124 V DCNPN ( common)G70D-FOM16PNP ( common)G70D-FOM16-1Note: These are all non-standard model and require a special order. Contact your OMRON representative for details on availability.Accessories (Order Separately)Cables for I/O Relay Terminals XW2Z-R Cable with Loose Wire and Crimp Terminals: Cable with Loose Wires: Cable with Fujitsu connectors W2Z-RO@C-@(1:3):XW2Z-R@C-@-@ Cable with MIL connectors @-@-D@XW2Z-RO@-@-D1Refer to the XW2Z-R Datasheet (Cat. No. G126) for details.Replacement RelaysApplicable Output -FOM16-1Rated voltageModelG6D-1A-ASI DC2424 V DCG3DZ-2R6PL DC24 ** This is a non-standard model and requires a special order.Contact your OMRON representative for details on availability.Accessories for DIN Track MountingRefer to your OMRON website for details on the PFP-@.SpecificationsRatingsPower MOSFET Relay Specifications (G6D Relay)The following specifications apply to G6D Relays mounted in a G70D Relay Terminal and not the G6D Relay itself.Coil Ratings (per G6D Relay)Rated voltage24 V DCRated current10.5 mACoil resistance2,880 ΩMust-operate voltage70% max. of rated voltageMust release voltage10% min. of rated voltageMax. voltage130% of rated voltagePower consumptionApprox. 200 mWNote: 1. The must-operate voltage is 75% or less of the rated voltageif the relay is mounted upside down.2. Rated current and coil resistance were measured at a coiltemperature of 23 C with a tolerance of 10%.3. Operating characteristics were measured at a coiltemperature of 23 C.4. The maximum allowable voltage is the maximum value ofthe allowable voltage range for the relay coil operatingpower supply. There is no continuous allowance.5. The rated current includes the terminal’s LED current.1

G70D-SOC16/FOM16Contact Ratings (per G6D Relay *1)LoadResistive load (cosφ 1)Rated load3 A at 250 V AC, 3 A at 30 V DCRated carry current3AMax. switching voltage250 V AC, 30 V DCMax. switching current3AMin. permissible load (reference value) *2Endurance10 mA at 5 V DCElectrical100,000 operations min. (under and at the rated load at 1,800 operations/hr)Mechanical20,000,000 operations min. (at 18,000 operations/hr)*1. Up to 3 A can be carried by the power supply terminals for outputs (terminals B0 to B7.)*2. This value is for a switching frequency of 120 times per minute.Power MOSFET Relay Specifications (G3DZ Power MOSFET Relay)Note: The following specifications apply to G3DZ Power MOSFET relays mounted in a G70D Relay terminal and not the G3.Input (per G3DZ Power MOSFET Relay)Output (per G3DZ Power MOSFET Relay)Rated voltage24 V DCLoad voltage3 to 264 V AC, 3 to 125 V DCOperating voltage19.2 to 28.8 V DCLoad current100 μA to 0.3 AMust-operate19.2 V DC max.Inrush current6 A (10 ms)Must release1 V DC min.Voltage levelInput impedance4 kΩ 20%Rated current8.2 mA 20%Note: The rated current includes the terminal’s LED 6(-1)ClassificationRelay outputsPower MOSFET relay outputsContact configuration16 points (SPST-NO 16)Contact structureSingle---Contact materialAg-Alloy (Cd free)---Contact resistance100 mΩ max. *1---Must-operate time10 ms max. *26 ms max.Release time10 ms max. *2Isolation method---PhotocouplerOutput ON-resistance---2.4 Ω max.Open-state leakage current---10 μA max. (at 125 V DC)Max. switching frequencyMechanical: 18,000 operations/hRated load: 1,800 operations/h---Insulation resistance100 MΩ min. (at 500 V DC)Dielectric strength2,000 V AC for 1 min between coil and contactNoise immunityPower input (normal mode): 600 V for 10 min with a pulse width of 100 ns to 1 μsPower input (common mode): 1.5 kV for 10 min with a pulse width of 100 ns to 1 μsInput cable (coiling): 1.5 kV for 10 min with a pulse width of 100 ns to 1 μsUnit body (coiling): 600 V for 10 min with a pulse width of 100 ns to 1 μsVibration resistanceDestruction: 10 to 55 to 10 Hz, 0.5-mm amplitude (1.0-mm double)Malfunction: 10 to 55 to 10 Hz, 0.375-mm amplitude (0.75-mm double)Shock resistanceDestruction: 300 m/s2Malfunction: 100 m/s2Operating voltage range24 V DCCurrent consumptionApprox. 300 mA at 24 V DC *3Cable lengthBetween block and controller: 5 m max. (reference value for AWG28)Between block and external device: Dependent on loadLED colorOperation indicator: orange; power supply: greenCoil surge absorberDiode (400 V, 300 mA)Ambient temperatureOperating: 0 to 55 C (with no icing or condensation)Storage: -20 to 65 C (with no icing or condensation)Ambient humidityOperating: 35% to 85%Mounting strengthNo damage when 49 N pull load was applied for 1 s in all directions (except for 9.8 N in direction of rail)Terminal strengthTightening torque: 0.78 to 0.98 N·mPull strength: 49 N for 1 minWeightApprox. 200 g2,000 V AC for 1 min between input and output terminals 10%/–15%Approx. 300 mA at 24 V DC *4Note: These values are initial values.*1. Measurement: 1 A at 5 V DC*2. Ambient temperature: 23 C*3. Current consumption is when all points are ON and includes G6D Relay coil current but does not include any external load current.*4. Current consumption is when all points are ON and includes G3DZ input current but does not include any external load current.2

G70D-SOC16/FOM16Engineering Data (Reference Value)G70D-SOC16(-1)Maximum Switching Capacity500Contact current (A)Number of operations ( 104 operations)Endurance Curve300100250 VAC or 30 VDC resistive load505030103031015250 VAC or 30 VDC inductive load(cosφ 0.4, L/R 7 ms)DC inductive loadAC inductive load(cosφ 0.4)0.50.330AC resistive loadDC resistive load5123456780.109 10351030100250 500 1,000Contact voltage (V)Contact current (A)G70D-FOM16(-1)Load Current vs. Ambient TemperatureSurge Withstand CurrentSurge current (A.Peak)Load current (A)Non-repetitive (If repetitive, keep the inrush current below the dotted line.)10.80.6108640.40.320.20-30 -200204055 6080Ambient temperature ( C)051030 50 100300Note: 1. The characteristics are given for whenthe product is mounted to the G70D.2. The data given here is a graphicrepresentation of actual values that weresampled on a manufacturing line. It isprovided here for reference only.The Relays are mass-produced andtherefore must be used to allow for a500 1,0003,000 10,000certain amount of variation inEnergizing time (ms)characteristics.3

G70D-SOC16/FOM16Internal CircuitsG70D-SOC16G70D-FOM16NPN Outputs ( common)Connector Pin Configuration(Top 109A13A687A14A765A150V430V24 V21Connector pin No.I/O indications onScrew Terminals579111315171968101214161820 XXXXXXXXXXXXXXXX24 VmarkA0B0 A1 B1 A2A3A4 B2 A5 B3 A6 B2 A7B3A8 B4 A9 B5 A10 B4 A11 B52143A12 B6 A13 B7 A14A15 24 0V* The above diagram is for the G70D-SOC16 (model for mounting G6D Relays).For the G70D-FOM16, G3DZ Power MOS FET Relays are mounted here.G70D-SOC16-1G70D-FOM16-1PNP Outputs (- common)Connector Pin Configuration(Top 109A13A687A14A765A150V430V24 V21Connector pin No.I/O indications onScrew Terminals579111315171968101214161820 XXXXXXXXXXXXXXXX24 VmarkA0 B0 A1 B1 A2A3A4 B2 A5 B3 A6 B2 A7B3A8 B4 A9 B5 A10 B4 A11 B54321A12 B6 A13 B7 A14A150V 24* The above diagram is for the G70D-SOC16-1 (model for mounting G6D Relays).For the G70D-FOM16-1, G3DZ Power MOS FET Relays are mounted here.Note: Pin numbers are indicated for convenience. The mark can be used to determine orientation.4

G70D-SOC16/FOM16Dimensions(Unit: mm)G70D-SOC16(-1)G70D-FOM16(-1)(53)156 max.135 0.2(25)40 0.251 max.(54)21.511.57630-M3639 max.Mounting Hole DimensionsTwo, 4.2-dia. holes or M4 screw holes40 0.2135 0.2Terminal Arrangement/Terminal Connection ExampleG70D-SOC16(-1)G70D-FOM16(-1)B7A13 A15LoadLoadLoadLoadPowersupplyB6 A12 A14PowersupplyLoadB4LoadA10PowersupplyA8A11 owersupplyB0B3LoadLoadLoad24-VDCpower supplyA2B1LoadA0A3Powersupply0A1LoadNCSOURCE24VDC PowersupplyNCPowersupplyNCLoadConnector Note: 1.: Internal circuits.2. There are two each of the followingterminals: B2, B3, B4, and B5.Connect the power supply to eitherone of each pair.* The diagram on the left is for the G70DSOC16(-1) (model for mounting G6DRelays). For the G70D-FOM16(-1), G3DZPower MOS FET Relays are mounted here.5

G70D-SOC16/FOM16Safety PrecautionsBe sure to read the Safety Precautions for All I/O Relay Terminals in the website at:http://www.ia.omron.com/.Warning IndicationsPrecautions forCorrect UseSupplementary comments on what to door avoid doing, to prevent failure to operate, malfunction, or undesirable effects onproduct performance.Precautions for Correct Use This Relay Terminal is for outputs only. G6D-1A-ASI DC24V Relays are mounted to the G70D-SOC16(-1),and G3DZ-2R6PL DC24V Relays are mounted to the G70DFOM16(-1). Opening the Front Cover (Rotating)Use both hands to lift up on the edges (A) at the bottom of the coverand rotate the cover.(A)(A)6

Terms and Conditions AgreementRead and understand this catalog.Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if youhave any questions or comments.Warranties.(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanshipfor a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omrondisclaims all other warranties, express or implied.(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUTNON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYERACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THEPRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by theProducts or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, atOmron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal orreplacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amountequal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Productswere properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriatemodification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shallnot be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical orelectronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the abovewarranty.See http://www.omron.com/global/ or contact your Omron representative for published information.Limitation on Liability; Etc.OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.Suitability of Use.Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to thecombination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicablethird party certification documents identifying ratings and limitations of use which apply to the Product. This information by itselfis not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Productwith respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGEQUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THEOVERALL EQUIPMENT OR SYSTEM.Programmable Products.Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequencethereof.Performance Data.Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determiningsuitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlateit to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.Change in Specifications.Product specifications and accessories may be changed at any time based on improvements and other reasons. It is ourpractice to change part numbers when published ratings or features are changed, or when significant construction changes aremade. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbersmay be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative atany time to confirm actual specifications of purchased Product.Errors and Omissions.Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility isassumed for clerical, typographical or proofreading errors or omissions.2017.2In the interest of product improvement, specifications are subject to change without notice.OMRON CorporationIndustrial Automation Companyhttp://www.ia.omron.com/(c)Copyright OMRON Corporation 2017 All Right Reserved.

Power MOSFET Relay Specifications (G6D Relay) The following specifications apply to G6D Relays mounted in a G70D Relay Terminal and not the G6D Relay itself. Coil Ratings (per G6D Relay) Note: 1. The must-operate voltage is 75% or less of the rated voltage if the relay is mounted upside down. 2. Rated current and coil resistance were measured .

Related Documents:

Table 2. Wiring terminal references for non-Excel 10/12 devices signal T7460A terminal T7460B terminal T7460C terminal Excel 800 XF82x terminal (example) Excel 500 XF52xB terminal (example) Excel 500 XFL52x terminal (example) Excel 100 terminal (example) Excel 50 terminal (example) Excel 20 terminal (example) CPO-FB22344R terminal (example)

Nissan Micra - OWM 4734 Nissan Micra - OWM 4734 CPU E6 H33750 1 Battery 2 Ignition switch 3 Fusible link holder 4 Fuse box 5 Fuse and relay box a) accessory relay b) blower motor relay 6 Intelligent power distribution module a) starter relay b) cooling fan hi relay c) cooling fan lo relay d) fuel pump relay e) ignition relay f) ECM relay

38 - Check voltage output to fuel pump @ relay set 39 - Check voltage input to relay set from ignition switch 40 - Check voltage input to fuel pump relay of relay set 41 - Check input voltage to control relay of relay set 42 - Check input voltage to control relay of relay set (continued)

APEX Virtual Terminal 3 Viewing Your Virtual Terminal in the Apex Portal To view your virtual terminal, select the Virtual Terminal menu option and select the My Terminal submenu. From the My Terminal page, you can process credit card and eCheck transactions for your customers. NOTE: My Terminal is a standard terminal that currently .

Results are provided for actual relay testing. Part I: Distance Relay Tests (Texas A&M University) Distance relay testing can evaluate relay performance, calibrate relay settings, and identify system conditions that could cause unexpected relay operation. Developing a relay testing methodology requires consideration of how to model the power .

Relay Computer Harry Porter, Ph.D. Portland State University April 24, 2006. 2. 3 V. 4 Double Throw Relay. 5 V Double Throw Relay. 6 Four Pole, Double Throw Relay. 7 V Four Pole, Double Throw Relay. 8. 9 Schematic Diagrams. 10 Schematic Diagrams Assume other terminal is connected to ground. 11 Schematic Diagrams

contact at one relay terminal to a relay control input at the other relay terminal. Unfortunately, the realities of physics prohibit us from making a simple, direct, hardwired metal-lic control circuit connection betwee

PYTHON PROJECTS . When not programming, he likes climbing, backpacking, and skiing. He is also a keen photographer, artist, and acoustic music enthusiast. He lives in Scotland with his wife, Heather. ABOUT THE TECHNICAL EDITORS ALEX BRADBURY is a compiler hacker, Linux geek, and Free Software enthusiast. He has been a long time contributor to the Raspberry Pi project and also co-authored .