SMC AC MOTOR GEARED MOTOR - Komachine

1y ago
73 Views
12 Downloads
8.50 MB
52 Pages
Last View : 6d ago
Last Download : 3m ago
Upload by : Milena Petrie
Transcription

www.smec.co.krSMCAC MOTORGEARED MOTORExtended capacity Motor 0.2kW 160kWGeared Motor 0.2kW 22kW

Company Overview Foundation : 1958 Business items : Electric motors and Geared motors Head office factory- (#1813-1 Hakwoon-ri)44 Samdo-ro Yangchon-eupGimpo-si Gyeonggi-do Korea Certifications- ISO 9001- UL, CE, high-efficiency approval- INNO-BIZ, Venture Company, R&D Institute- Clean business sites by korean administration- Special Company for parts & material- To be a good corporate chief Awards- Award of 500 million export record- Award of 1000 million export record2www.smec.co.kr

Company History2010Now2015.2015.2014.2014.2014.Developed high-efficiency small wind generatorSelected AEO [authorized economic operator]11.3006.1211.1002.1801.212009. 12.1020002008. 04.142005. 09.172000. 10.121999. 02.24SHINMYUNG ELECTRIC CO.,LTD.2016Developed intelligent-type factory roof window systemSelected high-growth company for exporting Biz by S.B.CSelected Innobiz (INNO-BIZ) Co., Venture CompanyApproval special Company for parts & materialAward of 1000 million export record ertification of high-efficiency three phase electricCinduction motorSelected clean business sites by korean administrationMovement of head office and factory in GimpoCertified ISO 900119901995. 06.151994. 07.151994. 03.26 elected supporting Co., for Export by Gyeonggi SmallSand Medium Business Adminstration D evelopment New models of EP geared motordevelopment.Export of High Effiency motorsFounded R&D Institute. Movement of Head office and factory in Ansan Banwolindustrial complex.Approval of European TUV, CE certificationEstablished China Yantai Shinmyung electric Co., Ltd.UL, CSA approval for Three-phase induction motors.19801984. 02.101981. 06.23Launching geared motor productionUL approval for Single-phase induction motor1976. 10.061973. 07.031973. 03.13 ward 2.'nd prize of Q.C standardized cometition byACommercial & industrial MinistryAcquired Compact AC motor manufacturer's licenseShinmyung electric MFG. co. ltd. Incorporation (S.M.C)1958. 09.01Established Shinmyung Company1998. 07.171997. 10.151997. 03.111995. 10.31197019583신명전기 52P 영문최종출력-1.indd 32016-05-09 오후 4:20:49

ContentsSHINMYUNG ELECTRIC CO.,LTD.4Three-phase induction motorThree Phase Induction MotorThree Phase Induction Motor(Flange Type)Three Phase Induction Motor(Wood Work)Three Phase Induction Motor(Hydraulic Pump Type)Single-phase induction motor Single Phase Induction MotorSingle Phase Induction Motor(Cradle Base Type)Single Phase Induction Motor(Agricultural Dryer & Fan Type)Electric motor connection diagramMotor instruction manual81012131416161819EP Geared motor seriesEP Geared motor series Name, characteristics and advantages of each part22EP Geared motor series Specifications of reference standards and technical data 24EP Geared motor series Electronic motor generating capacity26 EP Geared motor series Electronic motor generating capacity and form classification 27EP Geared motor series EP Geared motor Performance data table I, Ⅱ28Efficiency & Power Plus Geared Motor30EP2 Geared motor SeriesEfficiency & Power2 Geared Motor40SMG Geared motor seriesSMG Geared motor series Type Classification Table (Coding System)SMG Geared motor seriesGeared motor instruction manual444548www.smec.co.kr신명전기 52P 영문최종출력-1.indd 42016-05-09 오후 4:20:49

Main ProductsHigh-efficiency three-phase induction motorThree-phase induction motorSingle-phase induction motor I EP Geared motor I EP2 Geared motorSMG Geared motor I Gear reducer(Helical,Planetary reducer,Worm,Bevel)SHINMYUNG ELECTRIC CO.,LTD.Quality Motors Since 19585신명전기 52P 영문최종출력-1.indd 52016-05-09 오후 4:20:50

Motor efficiency regulationsApplication95KoreaMotor typeExclusion90Output 0.75kW〜375kWIE1(StandardEfficiency)Dutycycleor S3(Duty cycle operationwith load time factor of80% or more)motor etc.80IE175IE270IE37.5kWKSC4202855.5kWspecial Insulation2P,4P,6P3.7kWPolesY-Δ startingSingle-speed,marine duty3 phaseVoltage 1,000V or lower explosion-proofsquirrel cageduty High sliptypeFrequency 60, 50, 60/50Canned motorInduction,extremely lowS1(continuous duty-rated) temperature g range1.5kWInternationalEfficiency Levels(IEC 60034-30)0.75kWSHINMYUNG ELECTRIC CO.,LTD.International Electrotechnical Commission (IEC) enacted IEC60034-30 that regulated efficiency classes for electric motorsin October 2008 and accelerated the high efficiency of electric motors in each country of the world. In Korea, three-phaseinduction motors have been produced according to Minimum Energy Performance Standards meeting the criteria for highefficiency energy appliances (MOTIE Notification No. 2014-220) set according the Article 15 of Energy Use Rationalization Actand the Enforcement Degree.Application timeI Minimum high efficiency standards (IE2)I Premium efficiency (IE3)- 2P/4P/6P0.75kW 15kW: From July 2010- 2P/4P/6P15kW 37kW: From January 2010- 2P/4P37kW 200kW: From July 2008- 6P37kW 160kW: From July 2008- 8P0.75kW 37kW: From January 2011- 8P37kW 110kW: From January 2010- 37kW 200kW: From October 2015- 200kW 375kW: From October 2016- 0.75kW 37kW: From October 2018Efficiency Levels- Minimum high efficiency standards (IE2)*MOTIE No. W160kW200kW6Open drip proof- Premium (IE3) standards*MOTIE Notification No. 2015-28Totally Enclosed2poles 4 poles 6 poles 8 poles 2 poles 4 poles 6 poles 8 93.093.093.693.6-Open drip proofTotally EnclosedRatedoutput 2 poles 4 poles 6 poles 8 poles 2 poles 4 poles 6 poles 8 95.895.882.587 95.885.586.589.589.591.791.792.493.093.693 9.589.591.091.091.791.793 4.085.586.586.589.589.590.290 mec.co.kr신명전기 52P 영문최종출력-1.indd 62016-05-09 오후 4:20:51

Time and effects of motor efficiency regulation2010KoreaUSA20112012Jul. IE2 0.75kW 201520162017Oct. IE3 37kW 200kWOct. IE3 200kW 375kW2018Oct. IE3 0.75kW 37kWDec. IE3 0.75kW (Not including geared motors)EuropeJun. IE2 0.75kW Jan. IE3 0.75kW Jan. IE3 7.5kW JapanJan. IE3.0 75kW ChinaSep. IE2 0.75kW Jan. IE3 0.75kW SHINMYUNG ELECTRIC CO.,LTD.ClassificationSep. IE3 0.75kW Reason for application of high-efficiency motors :To improve the economic efficiency for a long-term periodWhile it is relatively expensive to buy owing to its high-efficiency design, it can save operating costs in proportion to operatingtime. Therefore, it is possible to offset increased prices within a short period of time.st)cogtinal eramproNo es Power-savingricgpprofitsnitorasncy mo st)ierchicffeouc(pa high operatingsses ofExpenhasing price(purcPurchasing prices of a high-efficiency motorPurchasing prices of Normal MotorBreak-even pointThe power-saving profits for this period can write off theincreased price of a high-efficiency motor.Annual electric fee saving (KRW) Output(kW) Operating time (hour/ year)100Electric fee(KRW/kW) Efficiency ofNormal motors(%)100-Efficiency ofhigh-efficiencymotors (%)Example for calculationConditions for calculation2.2kWOutputIE2 Efficiency of a high-efficiency motor87.5%IE1 Efficiency of a standard motor83%Annual operating time1,600 hours (8 hours/day, 200 days)Electric fees57 won/kWhAnnual electric fee saving Approx.12,450 won7신명전기 52P 영문최종출력-1.indd 72016-05-09 오후 4:20:51

Three Phase Induction MotorSpecificationSHINMYUNG ELECTRIC CO.,LTD.LSOEWFQT GVHØDBUCFig ⅠLWOFTVGEQSAI4-ØK 1391591591791791792012012372662612892892894-ØK 18401318462356516406700406805457805457805457 External appearance and size can be changed without an advance notice to improve product performance.8www.smec.co.krAIFig 0m665m675m675m685m685m685m6

EOW Voltage :- 220V,220/380V,380V,220/440V,440VVAIFig ⅢL Poles : 2P,4P,6P,8P,2/4P,4/6P,4/8P rpm : K HOLESCE Type of Enclosure : Totally Enclosed Cooling System : Fan Cooled Type Rating : Continuous Insulation Class : B,F gradeOSFrequency : 60Hz(50Hz)HØDBU QT GFSHINMYUNG ELECTRIC CO.,LTD.LST GCBUWFHQV4-Ø24 HOLESAIFig KEY 0125125130BEARINGWEIGHT(Kg)LOAD UN-LOAD6202zz 6202zz76204zz 6202zz136204zz 6202zz136204zz 6203zz136204zz 6203zz156204zz 6203zz156205zz 6204zz186205zz 6204zz236205zz 6205zz236206zz 6205zz306206zz 6205zz286206zz 6205zz386206zz 6205zz326206zz 6205zz406308zz 6306zz576308zz 6306zz676309zz 6208zz1066309zz 6208zz1276310zz 6309zz1606310zz 6309zz1756312zz 6309zz2406313zz 6311zz2566313zz 6311zz 266/2566314zz 6311zz3206317zz 6313zz3716316zzC3 6313zzC35506319zzC3 6316zzC36906319zzC3 6316zzC38106319zzC3 6316zzc3 1090 External appearance and size can be changed without an advance notice to improve product performance.9

Three Phase Induction Motor (Flange Type)LSAP/2REVØKTØBØPFGJ IØUSHINMYUNG ELECTRIC CO.,LTD.SpecificationØDN-ØC HOLESFig ⅠLSARJ IØKTGFØBØPØUEVP/2ØDN-ØC HOLESFig 140350140450140450170450170450 External appearance and size can be changed without an advance notice to improve product 110110140140140140170170

SHINMYUNG ELECTRIC CO.,LTD.LARFP/2ØKTØBØPØUEVGSØDN-ØC HOLESFig Ⅲ Voltage : 220V,220/380V,380V,220/440V,440V Frequency : 60Hz(50Hz) Poles : 2P,4P,6P,2/4P,4/6P,4/8P rpm : 3,600(3,000), 1,800(1,500), 1,200(1,000), 900(750) Type of Enclosure : Totally Enclosed Cooling System : Fan Cooled Type Rating : Continuous Insulation Class : B,F 0540540F55556888810101212141416181820202222KEY 05060609090909090110110110110130130BEARINGLOAD UN-LOAD6204zz 6202zz6202zz 6202zz6204zz 6203zz6204zz 6203zz6205zz 6203zz6205zz 6204zz6205zz 6204zz6206zz 6205zz6206zz 6205zz6308zz 6306zz6308zz 6306zz6310zz 6208zz6310zz 6208zz6311zz 6309zz6311zz 6309zz6312zz 6311zz6313zz 6311zz6315zzC3 6311zzC36317zzC3 6313zzC36316zzC3 6313zzC36319zzC3 6316zzC36319zzC3 171/184248248268/274332381/394550690810 External appearance and size can be changed without an advance notice to improve product performance.11

Three Phase Induction Motor (For Wood Work)SHINMYUNG ELECTRIC CO.,LTD.Specification Voltage : 220V,220/380V,380V,220/440V,440V Frequency : 60Hz(50Hz) Poles : 2P rpm : 3,600(3,000) Type of Enclosure : Totally Enclosed Cooling System : Fan Cooled Type Rating : Continuous Insulation Class : B,F gradeLSOEWQHØDFUCIFig ⅠFrame Output(kW)No. POLE 1C4141393939DIMENSION(mm)QDE146 33 133146 33 133181 33 133181 33 154181 33 154F55555H7171909090I140140170170170 External appearance and size can be changed without an advance notice to improve product 43143143BEARINGWEIGHT 205zz256208zz6205zz286208zz6205zz33

Three Phase Induction Motor (For Hydraulic Pump Type) Poles : 4P rpm : 1,800(1,500) Type of Enclosure : Totally Enclosed Cooling System : Fan Cooled Type Rating : Continuous Insulation Class : B,F gradeWOSLEON-JFQCBUAI4-ØK HOLESFig ⅡFig ⅠLOESOEØDFN-JØDFØPN-JHBUC4-ØK HOLESAICBUFig 112S112M112M112M112M132S132MOutputPOLE Kw4 0.754 0.754 0.754 1.54 1.54 1.54 1.54 1.54 2.24 2.24 2.24 2.24 2.24 3.74 3.74 3.74 3.74 5.54 �ⅠⅡVVLS239 205249 202255 202261 222275 222275 222275 222261 222276.5 234.5293 244293 244270 228270 228318 258300 258300 258300 258337 292375 �RWLØRSAI4-ØK HOLESTQCPHTQHBUWN-JØDFØPØDFØRFrequency : 60Hz(50Hz)PE ØRLVoltage : 220V,220/380V,380V,220/440V,440VSHINMYUNG ELECTRIC CO.,LTD.S 4-ØK HOLESAIFig 4140140140140140178DIMENSION(mm)CDOWPH56.5 15.88 134.5 82 106.4 8062 12.7 152 99 82 9068 15.88 152 99 106.4 9051.5 19.05 152 99 90 9065.5 19.05 152 99 106.4 9065.5 15.88 152 99 106.4 9065.5 12.7 152 99 106.4 9051.5 19.05 152 99 105.6 9048.5 19.05 170 106.5 90 10055.5 19.05 173 108 106.4 10055.5 15.88 173 108 106.4 10057 19.05 177 115 90 11257 19.05 177 115 105.6 11275 22.23 177 115 146 11257 15.88 177 115 106.4 11257 19.05 177 115 106.4 11257 19.05 177 115 90 11266 19.05 224 139 146 13266 19.05 224 139 146 132QR162 82.55189 50.8189 82.55189 95.02189 82.55189 82.55189 82.55189 82.55207.5 95.02208 82.55208 82.55227 95.02227 82.55227 101.6227 82.55227 82.55227 95.02271 101.6271 101.6N2224222442244244444 External appearance and size can be changed without an advance notice to improve product 0146146170170170170177215BEARING WEIGHTTF LOAD UN-LOAD (Kg)17.74 3.98 6206zz 6203zz 2014.5 3.2 6205zz 6204zz 2017.74 3.98 6206zz 6204zz 2021.5 4.77 6207zz 6204zz 2321.5 4.77 6207zz 6204zz 2317.74 4 6207zz 6205zz 2314.5 3.2 6206zz 6204zz 2421.5 4.77 6207zz 6204zz 2321.5 4.77 6207zz 6205zz 3021.5 4.77 6207zz 6205zz 3017.74 3.98 6207zz 6205zz 3021.5 4.77 6207zz 6205zz 3221.5 4.77 6207zz 6205zz 3225.12 6.38 6008zz 6205zz 4017.74 3.98 6207zz 6205zz 3921.5 4.77 6207zz 6205zz 3921.5 4.77 6207zz 6205zz 3925.12 6.38 6308zz 6306zz 5725.12 6.38 6308zz 6306zz 6713

Single Phase Induction MotorSLEOVWTHØDQØNSHINMYUNG ELECTRIC CO.,LTD.SpecificationCBUFig ⅠSLAI4-ØK HOLESOEWHQØNVC4-ØK HOLESTFAIGBUFig ⅡØDFRAMENo.Split phase apacitorStarting & 1005612556125561147011470100561407014070 External appearance and size can be changed without an advance notice to improve product performance.14www.smec.co.krOUTPUT 4.3114.3

OEWVoltage : 220V Frequency : 60Hz(50Hz) Poles : 4P rpm : 1,800(1,500) Type of Enclosure : Open Drip-Proof Rating : Continuous Insulation Class : B,F grade Starting Method :- Split Phase Starting- Capacitor Starting- Capacitor Starting & Run HTFGQØNVCBUFig ⅢSLAIØD 4-ØK HOLESEOWBUFig 21212HTFGØNQVSHINMYUNG ELECTRIC CO.,LTD.LSØD 4-ØK 165165165T1313161616162018182424FKEY INGWEIGHTLOAD UN-LOAD (Kg)6202zz 6202zz76202zz 6202zz86204zz 6203zz116204zz 6203zz136204zz 6203zz166204zz 6203zz286205zz 6203zz326206zz 6204zz216206zz 6204zz326206zz 6204zz356206zz 6204zz38 External appearance and size can be changed without an advance notice to improve product performance.15

Single Phase Induction Motor (Cradle Base Type)LOEWVTHØDQØNSHINMYUNG ELECTRIC CO.,LTD.SBCAI4-ØK HOLESUFig ⅠFRAMENo.4848565656OUTPUTPOLE kW4 0.24 0.254 0.44 0.554 K30 76.2 143.2 150 930 76.2 143.2 150 940 94 176.3 165 1040 94 176.3 165 1040 94 176.3 165 248248T131315.515.515.5F666KEY SIZEGV- 25- 256 306 306 30BEARING WEIGHTLOAD UN-LOAD (Kg)6202zz 6202zz 76202zz 6202zz 96204zz 6203zz 126204zz 6203zz 146204zz 6203zz 16Single Phase Induction Motor (Agricultural Dryer & Fan Type)LSWBEICN-ØKJM( )ØPØUAØRHTA'ØDFig ⅠSECTIONA-A'SLWCJEIN-KM( TIONA-A'HFFig ⅡGA'DIMENSION(mm)KEY SIZEBEARING WEIGHTOUTPUTFIGPOLE kWLSECWBJM UDHNKPRTFGV LOAD UN-LOAD (Kg)4 0.25 Ⅰ 165.4 133 32.4 71.5 61.5 55.5 9.5 10(Left) 128 12 1100 49 160 182 11.5 - 6202zz 6202zz 54 0.754 1.014 1.1For order production of the above-mentioned size-information requests expected4 1.354 1.54 2.2 External appearance and size can be changed without an advance notice to improve product performance.www.smec.co.kr

SHINMYUNG ELECTRIC CO.,LTD.Brake OptionMiddle plateShaftmounting hubHexcoreExclusive 115,130 coreFeatures1. Best as a safety brake2. Large braking torque3. Controllable torque and easy attachment4. Long life and easy repairing5. Beautiful external appearance with DC power supply system attached in terminal box6. Good response and durabilityHDB Type Brake B-02 HDB-03 HDB-04 HDB-05 HDB-06 HDB-07 HDB-08 HDB-09 HDB-10 HDB-11 HDB-12 HDB-13 ge(DC V)DC 90 ( DC190, DC24 )Current(DC A) ty(Watt) 19.628.0405353120122150150166166 External appearance and size can be changed without an advance notice to improve product performance.신명전기 52P 영문최종출력-1.indd 17172016-05-09 오후 4:21:09

Motor Connection DiagramSHINMYUNG ELECTRIC CO.,LTD.1) Single-phase connectionSINGLE VOLTAGE3 Leads out4 leads out11Normal ERReversal rotationDOUBLE VOLTAGELow voltageHigh Voltage53164254321POWER556432POWERCOMPOWERCOM2) Three-phase connection3 Leads Out6 Leads outDirect startingRST1Single VoltageY- Starting23614253Low-voltage 220V ( Connection)Dual Voltage220V/380V614253RSTY- Start-up possible6 strands for connectionSame except forretrieval Operation (Direct Starting)RST614253RSTHigh-voltage: 380V (Y Connection)614253RSTY- Startupimpossible9 Leads outLow voltage (220V) High Voltage (440V) Low voltage (220V) High Voltage (440V)Double Voltage(1)220V/440V*Y- Startup impossible761842953RST761842953RSTConnections within electronic motor ( Connection)Reversal Rotation471582693RST471582693RST1R2S3TConnections within electronic motor (Y Connection)12 leads outLow voltage (220V)High Voltage (440V) Operation (direct startup)Y Startup Operation (direct startup)Y StartupDouble Voltage(2)220V/440V*Y- 85212963RST741218510296113역회전RSTElectric motor troubles and checking ListPhenomenonStarting TroublesOverheatingRapid speed drop underloadingSerious vibrationBearing overheating andnoise18CauseChecking list Frost formation (poor power supply checkup, coildisconnection) Less of Starting torque & Over Loading Check power supply Check winding resistance Check load condition Check bearing constrain state Overload Power supply trouble (like overvoltage) Winding trouble Rotor hit Stator ID Bad ventilation Check electric current (same with or less than electric currentwritten on rating plate) Check voltage, frequency Measure winding Measure air gap Check factorspreventing ventilation Voltage drop Overload Incorrect Y-Δ Connection Check power line Check load condition Check contact Incorrect Loading connection Bearing failure Disconnected 1 phase operating Shaking fixing supporter Check load connection, replace bearings Check power supply and measure winding resistance Strong mounting Incorrect load connection Grease shortage Excessive tension Check load connection Supplement grease Adjust tensionwww.smec.co.kr신명전기 52P 영문최종출력-1.indd 182016-05-09 오후 4:21:10

Motor Instruction Manual❷ Winding❽ Frame❻ Rotor❸ Bearing❼ Shaft For using the products for long time, the level of electric current shouldbe lower than that written on the rating plate. Don’t put inflammable substances on the surface of electric motors oraround them to prevent fires. Be sure to equip devices to protect electric motors. It is highly dangerous to change motors arbitrarily to use them forspecial purposes. While operating motors of 3 4P 7.5kW(6P 5.5kW) or higher, right Y- switches and starting compensators should be chosen.4 Check before operation and right operation method Check before operation❺ Stator❶ Cooling Fan❹ Lead BoxI sincerely thank customers for buying products of ShinmyungElectric. Shinmyung equipped with competent technical workersand ultra-precision machinery does its best to make high-qualityproducts by strictly managing quality. We ask customers to be fullyaware of this instruction before testing and using our products inorder to prevent safety accidents and maintain the best performanceof the products.2 Installation place and suggestions for installation Installation place Install the products at places where ambient temperature is 40 or lower. To use the products for long, they should be installed in dry and wellventilated places. Suggestions for installation Please check if there are something that can cause problems beforeoperating electric motors Bolts for fixing motors should fit motor base holes and washers shouldbe used for connecting bolts to prevent them from being loosened byvibration. Be careful not to put high strain to the shaft while connecting a pulleyand a coupling. If a shock is given to the shaft, bearings can be damagedand there can be strange sound. While conveying turning force using a belt, the load point should beinside the shaft end, or close to the motor. The pulley and the coupling should be balanced while being used. If theyare not balanced, bearings can be worn and there can be vibration.3 Matters to be observed Wiring should be done following standards for electric facilities, wiringrules and KEPCO regulations. Grounding should be done using attached earth bolts. Be careful not to drop insulation efficiency by rain or water whileinstalling or keeping the products at outdoor places and to prevent rustfrom being formed in shafts and outside and inside of electronic motors.SHINMYUNG ELECTRIC CO.,LTD.1 Configuration of parts Check if supplied power is same with that of the rating plate. Check if connection was done following the circuit diagram of the rating plate. Check if shafts of electric motors by turning them with hands. Check if capacities of switches and breakers are same with those of electricmotors. Right operation method Check the rotation direction. If the rotation direction is wrong, powersupply should be cut and the direction should be changed according toconnection of the rating plate and instructions. Check if the electric current in full load is same or less than that of the ratingplate. If the electric current is higher than that of the rating plate, it can causeproblems in motors due to overload. In that case, load should be adjusted. Check if there is noise or serious vibration in bearings during operation. While opening or closing switches, connection or blocking should be donerapidly. If connection is not complete while injecting switches, powerfacilities and motors can be affected. Load should be light as much as possible and load should be put whenmotors rotate in full speed. If load is put before motors rotate in full speed,motors may stop because they don’t bear load. During a blackout, switches should be turned off.5 Spot check and regular check Spot check Check if the electric current is same with or lower than rating electriccurrent of the rating plate during operation. If the figure is higher than thatwritten on the rating plate, there can be overload. Check if there are no problems in bearing noise and vibration. Check if there are loose motor fixing bolts. Check if belt tension is proper while using belts. Regular check Dust or dirt inside and outside of motors can cause troubles in coolingeffects or insulation performance, so they should be cleaned using cleancloth or brushes. Precaution: Windings should not be cleaned with matters affectinginsulation, such as solvent, thinner and water. Parts loosened from vibration should be perfectly connected to preventmotor troubles. Winding connection and insulation conditions should be checked regularlyto prevent electric leakage and shock which may cause property damagesand casualties. Proper lubricants should be injected regularly in bearings and sealedbearings should be replaced regularly.19신명전기 52P 영문최종출력-1.indd 192016-05-09 오후 4:21:10

Motor Instruction ManualSHINMYUNG ELECTRIC CO.,LTD.6 Electric Motor troubles and measures for themTroubleCause1.Power switches are blocked.2.Rating voltage is low3.Winding or circuits are disconnected.4.The fuse is blown.5.There is overloading.6.Starters have problems.7.Bearings are worn or have troubles.8.There are troubles in centrifugal switches.(in case of single-phase)9.Capacitor has problems. (in case of single-phase)1.Connect power switches.2.Check if it is the rating voltage.3.Measure the resistance and check circuits.4.Replace with a right fuse.5.Check load conditions and adjust load.6.Check if there are problems in starter connection.7.Replace bearings.8.Check centrifugal switches.9. Check if there are problems in Capacitor and theirconnection.1.Ventilation is not smooth.2.There are problems in the power voltage and frequency.3.There is the over current in the state of overload.4.There are problems in connection and joining of leader lines.5.Windings or circuits have problems.1.Remove dust or foreign substances from the wind course.2.Check the power voltage and frequency.3.Adjust the load to lower than the rating electric current.4.Check joining, connection and disconnection.5.Measure resistance to check problems.The rotation speedrapidly drops duringoperation.1.There is overload during operation.2.The power voltage rapidly dropped.3.Coils are disconnected or circuit joining is bad.1.Check load and adjust it.2.Check the power voltage.3. Measure the resistance and check disconnection and joining.There are seriousvibration and noise.1.The shaft center is not straight.2.Fixing bolts are loos

AC MOTOR GEARED MOTOR Extended capacity Motor 0.2kW 160kW Geared Motor 0.2kW 22kW. Company Overview Foundation : 1958 . 07.03 Acquired Compact AC motor manufacturer's license 1973. 03.13 Shinmyung electric MFG. co. ltd. Incorporation (S.M.C) 1958. 09.01 Established Shinmyung Company 2016 2010 2000 1990

Related Documents:

Mexico SMC Corporation (Mexico), S.A.de C.V. Argentina SMC Argentina S.A. Europa/Africa Switzerland SMC Pneumatik AG Austria SMC Pneumatics GmbH (Austria) Sweden SMC Pneumatics Sweden AB France SMC Pneumatique S.A. Spain SMC España, S.A. Asia/Oceania Australia SMC Pneumatics (Aust.)Pty.Ltd. Singapore SMC Pneumatics (S.E.A.)Pte.Ltd.

GF-SMC UD prepreg Pure CF-SMC CF-SMC UD prepreg Co-Molding Process SMC Prepreg Materials Used Estimated Part Mass* (including inserts for composites) Mass Change Estimated Stiffness* Stamped Aluminum 6.50 kg 0 (baseline) 70 GPa GF-SMC UD/CF-prepreg 4.90 kg 25 % GF-SMC: 11.5 GPa Prepreg: 120 GPa CF-SMC UD/CF-prepreg 3.90 kg 40%

SMC-3, SMC Flex, and SMC-50 Smart Motor Controllers Control Mode Overview Allen-Bradley SMC controllers have multiple control modes available to control standard 3-phase induction motors, depending upon the product selected. For a full description of the control modes available for each product type, consult the appropriate product user manual.

AUSTRALIA SMC Pneumatics(Australia)Pty.Ltd. NEW ZEALAND SMC Pneumatics(N.Z.)Ltd. Asia/Oceania JAPAN SMC Corporation Asia/Oceania CZECH REPUBLIC SMC Industrial Automation CZ s.r.o. HUNGARY SMC Hungary Ipari Automatizálási Kft. POLAND SMC Industrial Automation Polska Sp. z o.o. SLOVAKIA SMC Priemyselná Automatizácia Spol s.r.o.

Using the SMC HTTP Server Component 36 SMC Configuration Scenarios 37 Scenario 1: Single TapePlex with SMC and HSC on the Same Host 38 Scenario 2: Single TapePlex using the SMC Client/Server Feature 39 Scenario 3: Two TapePlexes Accessed by a Single SMC 41 Client/Server Drive Address Mapping 43 SMC Drive Type Information Synchronization 44

ONLINE commed.smc.edu PHONE 310-434-3402 EMAIL smcext@smc.edu FAX 310-434-3409 MAIL SMC Community Education 1900 Pico Boulevard Santa Monica, CA 90405 VISIT SMC Bundy Campus 3171 S. Bundy Drive, Room 112 Los Angeles, CA 90066 8:30 am to 5 pm, M-F Table of Contents SMC Extension Santa Monica College Prof

memory. The SMC-R protocol defines a means to exploit the shared memory for communications - transparent to the applications! Shared Memory Communications via RDMA SMC SMC RDMA enabled (RoCE) RNIC Clustered Systems This solution is referred to as SMC-R (Shared Memory Communications over RDMA). SMC-R is an open sockets

Access to Accounting Software – SAMS – Assessment book . 2 . Notes for students . This sample assessment is designed to demonstrate as many of the possible question types you may find in a live assessment. It is not designed to be used on its own to determine whether you are ready for a live assessment. In a live assessment, you will be required to upload documents as part of your evidence .