OPTISONIC 6300 PTechnical DatasheetPortable ultrasonic clamp-on flowmeter User friendly operation through full colour graphic display and full keypad Quick and easy transfer of logged data to your PC through USB interface Sensors: robust, fast installation, high performance KROHNE 03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

CONTENTSOPTISONIC 6300 P1 Product features31.1 Portable clamp-on flowmeter. 31.2 Variants. 51.3 Measuring principle. 72 Technical data82.1 Technical data. 82.2 Dimensions and weights . 142.2.12.2.22.2.32.2.4Clamp-on sensor . 14Converter. 15I/O box . 16Trunk on wheels. 173 Installation183.1 Intended use . 183.2 Find location and determine data . 184 Electrical connections4.14.24.34.4222Safety instructions. 22Power supply . 22Signal cable . 23Connection diagrams . 245 Application form296 Notes31www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

PRODUCT FEATURES 1OPTISONIC 6300 P1.1 Portable clamp-on flowmeterThe new OPTISONIC 6300 P flowmeter combines mobile, straightforward and quick liquidmeasurement with the proven precision and reliability of KROHNE ultrasonic technology. Simplyattach the sensor unit to the tube and connect the compact evaluation unit - now just read theresults. It is just as easy to use the device for data logging. Data is saved to a USB stick andtransferred to external evaluation systems. Its ease of use and flexibility make theOPTISONIC 6300 P the ideal solution for flow measurement in a variety of applications in virtuallyany sector of industry.03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com3

1 PRODUCT FEATURESOPTISONIC 6300 PHighlights Quick and easy sensor mountingComprehensive user interfaceEasy transfer of logged data to PC14 hours battery lifeEnergy measurementIndustries ChemicalsPetrochemicalsPower plantsWaterOil & GasSemi-conductorFood & BeveragesPharmaceuticalsHVACMetal & SteelApplications 4Commissioning of HVAC systemsChecking of inline flowmetersChecking of pump performanceTemporary replacement of defective flowmetersGeneral flow related problem solvingwww.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

PRODUCT FEATURES 1OPTISONIC 6300 P1.2 VariantsThe OPTISONIC 6300 P is a battery powered ultrasonic clamp-on flowmeter that can be fitted onthe outside of piping to measure the flow rate of liquids. The OPTISONIC 6300 P is intended fortemporary flow measurement. It consists of a combination of one or two clamp-on sensor(s) andone handheld electronic signal converter.The OPTISONIC 6300 P comes as a complete and ready to use flowmeter in a robust case thatcan be carried as a trolley.What's standard included? UFC 300 P converter including batterycharger / power supply and mountingstrap Product documentation USB stick Coupling fat Tape measure Backpack Trunk on wheelsFlow sensor options Single rail flow sensor for pipe sizesDN15.DN150 (½.6") Single rail flow sensor for pipe sizesDN50.DN250 (2.10") Dual rail flow sensor for pipe sizesDN200.DN1500 (8.60")Two flow sensors of the same type canbe connected to the converterelectronics simultaneously for dualpath or dual pipe flow measurement.A maximum of 4 sensor rails can befitted in the case.03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com5

1 PRODUCT FEATURESOPTISONIC 6300 PI/O connectionFor connection of I/O signals like pulse orcurrent outputs a cable with I/O connectionbox is available optionally.Energy measurementStandard the OPTISONIC 6300 P is providedwith a measurement option for thermalenergy. This requires the input of 2temperature measurements in addtion to theflow measurement.For temperature measurement an I/Oconnection box is available to connecttemperature transmitters. For directconnection of PT100 sensors, the I/O box canoptionally be fitted with 2 temperaturetransmitters. When temporary temperaturemeasurement is required 2 clamp-on PT100sensors can be ordered optionally.Optional thickness gaugeFor setting up the flow measurement, thepipewall thickness must be known. Tomeasure this, a pipewall thickness gauge canbe ordered with the OPTISONIC 6300 P.6www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

PRODUCT FEATURES 1OPTISONIC 6300 P1.3 Measuring principle Like canoes crossing a river, acoustic signals are transmitted and received along a diagonalmeasuring path. A sound wave going downstream with the flow travels faster than a sound wave goingupstream against the flow. The difference in transit time is directly proportional to the mean flow velocity of the medium.Figure 1-1: Measuring principle12345Transducer ATransducer BFlow velocityTransit time from transducer A to BTransit time from transducer B to A03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com7

2 TECHNICAL DATAOPTISONIC 6300 P2.1 Technical data The following data is provided for general applications. If you require data that is morerelevant to your specific application, please contact us or your local sales office. Additional information (certificates, special tools, software,.) and complete productdocumentation can be downloaded free of charge from the website (Download Center).Measuring systemMeasuring principleUltrasonic transit timeApplication rangeFlow measurement of liquidsMeasured valuePrimary measured valueTransit timeSecondary measured valueVolume flow, mass flow, flow speed, flow direction, speed of sound, gain,signal to noise ratio, diagnosis value, reliability of flow measurement,quality of acoustic signal, thermal energy (requires input of temperature(2x)).DesignThe measurement system consists of one or two measuring sensors anda portable signal converter.Signal converterPortable housingUFC 300 PMeasuring sensorStandardSingle or dual rail sensors with 1 or 2 MHz transducersOptionalOPTISONIC 6300 flow sensors using cable adaptersDiameter rangesDN15.150 / ½.6"One rail, 2 MHz transducersOuter diameter must be at least 20 mm / ¾".DN50.250 / 2.10"One rail, 1 MHz transducersDN200.1500 / 8.60"Two rails, 1 MHz transducersOptionsOutputs0(4).20 mA, pulse, frequency and/or status outputInputs0(4).20 mA (2x) with optional I/O box.Counters4 internal counters with a maximum of 8 counter places, for countingvolume, energy and/or mass units.USB1x host port (PC can use OPTISONIC 6300 P as a removable mediadevice)1x slave (memory stick can be written by converter)Self diagnostics8Integrated verification, diagnostic functions: flowmeter, process,measured value, empty pipe detection, bar graph.www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

TECHNICAL DATA 2OPTISONIC 6300 PDisplay and user interfaceGraphic display4.3" TFT with LED backlight, daylight readable272x480 dots resolutionThe readability of the display could be reduced at ambient temperaturesbelow -25 C / -13 F.Operator input elements21 Key tactile keypad:1 on/off key4 cursor keys for menu operation12 keys for alpha / numerical input (SMS style)4 function keys for direct access to main functionsDisplay functionsMenuWizard for setup and configuration of measurements.Support for the configuration of 2 path / 2 pipe or 2 path / 1 pipemeasurement.Averaging, adding or subtracting of measurement results of 2 pathmeasurements.Storage of measurement configurations as site file.Maximum of site files is 100.Measurement data can be displayed as value or as bar or trend graph.Thermal energymeasurementBy input of 2 temperature sensors providing a temperature difference,thermal energy can be calculated.Data loggerLogging of selected measured / calculated values. Data to be logged andtime interval can be set. A maximum number of 150000 values / 50 filescan be stored. Display of logged data through line graphs.Language of display textsEnglish, French, German, Italian, Spanish.Other languages on request.UnitsMetric, British and US units selectable from list / free unit.Measuring accuracyReference conditionsMedium: waterTemperature: 20 C / 68 FStraight inlet section: 10 DNMaximum measuring error 1% of the measured value for DN 50 mm / 2" and v 0.5 m/s / 1.5 ft/s 3% of the measured value for DN 50 mm / 2" and v 0.5 m/s / 1.5 ft/sRepeatability03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en 0.2%www.krohne.com9

2 TECHNICAL DATAOPTISONIC 6300 POperating conditionsTemperatureProcess temperatureStandard version: -40. 120 C / -40. 248 FAmbient temperatureSensor: -40. 70 C / -40. 158 FSignal converter: -20 55 C / -4 131 F(Humidity: 5.80%, non condensing)Storage temperature-30 80 C / -22 176 F(Humidity: 5.80%, non condensing)Pipe specificationsMaterialMetal, plastic, ceramic, asbestos cement, internal / external coatedpipes (coatings and liners fully bonded to pipe wall)Pipewall thickness 200 mm / 7.87"Liner thickness 20 mm / 0.79"Media propertiesPhysical conditionLiquidsViscosity 100 cSt (general guideline)For detailed information please contact your local representative.Permissible gas content(volume) 2%Permissible solid content(volume) 5%Recommended flow velocity0.5.20 m/sInstallation condititionsMeasurement configurationSingle pipe, single pathSingle pipe, dual pathDual pipe, dual pathInlet run 10 DN straight lengthOutlet run 5 DN straight lengthDimensions and weightsFor detailed information refer to Dimensions and weights on page 14.Materials10SensorAnodized aluminum (rail)ConverterPolyamide PA12, covered with TPE soft touch layer on the sidesTrunk on wheelsPolypropylenewww.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

TECHNICAL DATA 2OPTISONIC 6300 PElectrical connectionsPower supplyAdapter for 100 240 VAC (-10% / 10%), 47.63 HzAdapter voltage: 13.2 VMaximum power consumption: 10 W (25 W during charging)Charging time: 8 hoursBattery type: Lithium polymerBattery lifetime:Measuring operation (display at 50% brightness): 14 hoursSignal cabledouble shielded, internal triax, length: 3 m / 15 ftUSB ports1x for PC, 1x for memorystickInputs / outputs15 pin connector for I/O interfacing with optional I/O boxOptional: PT100 input:Function: PT 100 temperature input by 2x KROHNE TT30C temperaturetransmitters build into an I/O boxFor specifications see TT30C datasheet.Optional: temperature input:Function: temperature input by 2x KROHNE TSR-W 30 clamp-ontemperature sensors only in combination with I/O box with temperaturetransmitters.For specifications see TSR-W 30 datasheet.Inputs and outputsConnectionsInputs and outputs can only be connected using the optional I/O box.Description of usedabbreviationsUext external voltageRL load resistanceUo terminal voltageInom nominal currentCurrent outputIsolationThe output is not galvanically isolated from the other circuits.Output dataAll analog measurement parameters like volume and mass flow (atconstant density), flow speed, speed of sound, gain, signal to noise ratio,reliability of flow measurement, quality of acoustic signal, thermalenergy (requires input of temperature (2x)).SettingsQ 0%: 0 20 mA; Q 100%: 10 21.5 mAError identification: 0 22 mAOperating dataActiveUint,nom 15 VDCI 22 mARL 450 ΩPassiveUext 32 VDCI 22 mAU0 1.8 V at I 22 mA03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com11

2 TECHNICAL DATAOPTISONIC 6300 PPulse or frequency outputIsolationThe output is galvanically isolated from the other circuits.Output dataFor pulse counting and/or analog output: Volume flow, mass flow,thermal energy (requires input of temperature (2x)As analog output: Flow speed, speed of sound, gain, signal to noise ratio,reliability of flow measurement, quality of acoustic signalFunctionCan be set as a pulse output or frequency outputSettingsFor Q 100%: 0.01.10000 pulses per second or pulses per unit volumePulse width: setting automatic, symmetric or fixed (0.05.2000 ms)Operating dataActiveUnom 15 VDCfmax 100 Hz:I 20 mAopen:I 0.05 mAclosed:U0,nom 15 V at I 20 mA100 Hz fmax 10 kHz:I 20 mAopen:I 0.05 mAclosed:U0,nom 13.5 V at I 1 mAU0,nom 12.5 V at I 10 mAU0,nom 9 V at I 20 mAPassiveUext 32 VDCfmax 100 Hz:I 100 mAopen:I 0.05 mA at Uext 32 VDCclosed:U0, max 0.2 V at I 10 mAU0, max 2 V at I 100 mA100 Hz fmax 10 kHz:I 20 mAopen:I 0.05 mA at Uext 32 VDCclosed:U0, max 1.5 V at I 1 mAU0, max 2.5 V at I 10 mAU0, max 5.0 V at I 20 mA12www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

TECHNICAL DATA 2OPTISONIC 6300 PStatus outputIsolationThe output is galvanically isolated from the other circuits.Function and settingsSettable as automatic measuring range change, indicator for direction offlow, overflow, error, operating point or empty pipe detectionStatus and/or control: ON or OFFOperating dataActiveUint 15 VDCI 20 mAopen:I 0.05 mAclosed:U0, nom 15 V at I 20 mAPassiveUext 32 VDCI 100 mAopen:I 0.05 mA at Uext 32 VDCclosed:U0, max 0.2 V at I 10 mAU0, max 2 V at I 100 mACurrent inputsIsolationThe inputs are not galvanically isolated from the other circuits.FunctionInput of temperature, used for energy calculation in combination withflow measurementRange: -50.500 C / -58.932 F (default: 0.120 C / -32.248 F)Operating dataActiveUint 15 VDCI 22 mAImax 26 mA (electronically limited)U0, min 9 V with I 22 mANo HART PassiveUext 32 VDCI 22 mAImax 26 mA (electronically limited)U0, max 5 V with I 22 mANo HART Approvals and certificatesCEThis device fulfills the statutory requirements of the EC directives.The manufacturer certifies successful testing of the product by applyingthe CE mark.Electromagnetic compatibility Directive: 2004/108/ECHarmonized standard: EN 61326-1: 2006Low voltage directiveDirective: 2006/95/ECHarmonized standard: EN 61010: 2001Other approvals and standardsProtection category acc. toIEC 529 / EN 60529 /NEMA 250/2003Sensor: IP 67 / NEMA 6Converter: IP 65 / NEMA 4Trunk on wheels: IP 67 / NEMA 6Power adapter: IP 40 / NEMA 1Shock test sensorIEC 60068-2-27Vibration test sensorIEC 60068-2-6403/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com13

2 TECHNICAL DATAOPTISONIC 6300 P2.2 Dimensions and weights2.2.1 Clamp-on sensorDimensions [mm]LHW4067639.2Approx. weight[kg]2.1 11 with transducers / cable, without mounting strapDimensions [inches]LHW16.03.02.5Approx. weight[lb]4.6 11 with transducers / cable, without mounting strap14www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

TECHNICAL DATA 2OPTISONIC 6300 P2.2.2 Converter12ABC3DEF456GHIJKLMNO789PQRSTUVWXYZ /-0EXPA/a-I/ODISPLAYLOGGERMENUDimensions UFC 300 P converterDimensions [mm]abcd24728916866Dimensions [inch]abcd9.711.46.62.603/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.comApprox. weight[kg]1.6Approx. weight[lb]3.515

2 TECHNICAL DATAOPTISONIC 6300 P2.2.3 I/O boxabbcDimensions I/O boxDimensions [mm]Approx. weight [kg]abc112.584.641.3Dimensions [inch]160.2Approx. weight [lb]abc4.43.31.6www.krohne.com0.4403/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

TECHNICAL DATA 2OPTISONIC 6300 P2.2.4 Trunk on wheelsDimensions trunk on wheelsDimensions [mm]Approx. weight [kg]abc565374241Dimensions [inch]Approx. weight [lb]abc22.214.79.503/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en6.2www.krohne.com13.717

3 INSTALLATIONOPTISONIC 6300 P3.1 Intended useResponsibility for the use of the measuring devices with regard to suitability, intended use andcorrosion resistance of the used materials against the measured fluid lies solely with theoperator.The manufacturer is not liable for any damage resulting from improper use or use for other thanthe intended purpose.The OPTISONIC 6300 P portable clamp-on flow meter is designed for measurement of liquidflows in full pipes, datalogging and transfer of logged results to the PC. The portable clamp-onflow meter makes it possible to measure the flow on places temporary or you can make use of itif you want to compare the output with other measurement devices.If an inline measurement device is broken and you are in need of the information the OPTISONIC6300 P might be the solution for you.3.2 Find location and determine dataInlet, outlet and recommended mounting areaTo perform an accurate flow measurement preferably mount the sensor rail at least 10 DNdownstream of a flow disturbance like elbows, valves, headers or pumps. Follow the giveninstallation recommendations.Figure 3-1: Inlet, outlet and recommended mounting area1 Min. 10 DN2 Min. 5 DN3 Recommended installation location (120 )Make sure that the rail is not mounted at the highest point (risk for air bubbles) or at the lowestpoint (risk for particles) of the pipe.18www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

INSTALLATION 3OPTISONIC 6300 PLong horizontal pipes Install on slightly ascending pipe section. If not possible, make sure that the flow velocity is high enough to prevent air, gas or vapor tocollect in upper part. In partially filled pipes, the clamp-on flowmeter will report incorrect flow rates, or notmeasure.Figure 3-2: Long horizontal pipesVertical pipelinesMake sure that the pipe is fully filled at all times.Both ascending and descending flow directions are measurable.Figure 3-3: Mounting on vertical pipelines is possible03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com19

3 INSTALLATIONOPTISONIC 6300 POpen feed or dischargeInstall meter on a lowered section of the pipe to make sure that there is a full pipe condition.Figure 3-4: Open feed or dischargeDown going pipeline over 5 m / 16 ft lengthInstall an air vent downstream of the flowmeter to prevent vacuum. It may cause gases to comeout of solution (cavitate) that prevent a proper measurement.Figure 3-5: Down going pipeline over 5 m / 16 ft lengthPosition of control valveAlways install control valves downstream of the flowmeter in order to avoid cavitation ordistortion of the flow profile.Figure 3-6: Position of control valve20www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

INSTALLATION 3OPTISONIC 6300 PPosition of pumpNever install the flowmeter at the suction side of a pump in order to avoid cavitation or flashingin the flowmeter.Figure 3-7: Position of pumpDetermine data and dimensions of pipeThe next data must be available before proceeding. Use the supplied tape measure to determine the outside diameter of the pipe. Determine the pipe wall thickness. A pipe wall thickness gauge or pipe tables can be used forthis. Find out what the material of the pipe is. If the pipe has a liner, find out the liner material and the thickness of the liner.03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com21

4 ELECTRICAL CONNECTIONSOPTISONIC 6300 P4.1 Safety instructionsAll work on the electrical connections may only be carried out with the power disconnected. Takenote of the voltage data on the nameplate!Observe the national regulations for electrical installations!Observe without fail the local occupational health and safety regulations. Any work done on theelectrical components of the measuring device may only be carried out by properly trainedspecialists.Look at the device nameplate to ensure that the device is delivered according to your order.Check for the correct supply voltage printed on the nameplate.4.2 Power supplyOnly use the supplied AC charger to charge the battery of the converter!i/oUSB12DC in1Plug in the connector of the supplied charger at the connector 1. Then insert the main powerconnector into your mains outlet.The battery status indicator will be accurate after an initial full discharge directly followed by afull charge of the battery.22www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

ELECTRICAL CONNECTIONS 4OPTISONIC 6300 P4.3 Signal cableFind the calibration numbers that are noted on the labels on the cable of each transducer. Makesure that both transducers have the same calibration number as shown by the converter.The signal cables are prefixed to the transducers in the factory.11221123ABCDEF456GHIJKLMNO789PQRSTUVWXYZ /-0EXPA/a-I/ODISPLAYLOGGERMENU2Figure 4-1: Connecting signal cables1 Connector for "UP" transducer (blue)2 Connector for "DOWN" transducer (green)You can measure two paths with this converter simultaneously. Use the left pair of connectorsfor path 1 and the right pair for path 2.03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com23

4 ELECTRICAL CONNECTIONSOPTISONIC 6300 P4.4 Connection diagramsmA meter0.20 mA or 4.20 mA and otherRL is the internal resistance of the measuring point including the cableresistanceDC voltage source (Uext), external power supply, any connection polarityDC voltage source (Uext), observe connection polarity according toconnection diagramsInternal DC voltage sourceControlled internal power source in the deviceElectronic or electromagnetic counterAt frequencies above 100 Hz, shielded cables must be used to connect thecounters.Ri Internal resistance of the counterButton, NO contact or similar24www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

ELECTRICAL CONNECTIONS 4OPTISONIC 6300 PObserve connection polarity.4.20 mA current output active Uint,nom 15 VDC nominal I 22 mA RL 600 Ω Not galvanically isolated.Figure 4-2: Current output active IaCurrent output passive, basic I/Os Uext 32 VDC I 22 mA U0 1.8 V RL (Uext - U0) / Imax Not galvanically isolated.Figure 4-3: Current output passive Ip03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com25

4 ELECTRICAL CONNECTIONSOPTISONIC 6300 PPulse / frequency output Any connection polarity. Galvanically isolated.Pulse/frequency output passive Uext 32 VDC fmax in operating menu set to fmax 100 Hz:I 100 mAopen:I 0.05 mA at Uext 32 VDCclosed:U0, max 0.2 V at I 10 mAU0, max 2 V at I 100 mA fmax in the operating menu set to 100 Hz fmax 10 kHz:I 20 mAopen:I 0.05 mA at Uext 32 VDCclosed:U0, max 1.5 V at I 1 mAU0, max 2.5 V at I 10 mAU0, max 5.0 V at I 20 mA If the following maximum load resistance RL, max is exceeded, the load resistance RL must bereduced accordingly by parallel connection of R:f 100 Hz: RL, max 47 kΩf 1 kHz: RL, max 10 kΩf 10 kHz: RL, max 1 kΩ The minimum load resistance RL, min is calculated as follows:RL, min (Uext - U0) / Imax Can also be set as a status output; for the electrical connection, see status output connectiondiagram.Pulse/frequency output active Unom 15 VDC fmax in operating menu set to fmax 100 Hz:I 20 mAopen:I 0.05 mAclosed:U0, nom 15 V at I 20 mA fmax in the operating menu set to 100 Hz fmax 10 kHz:I 20 mAopen:I 0.05 mAclosed:U0, nom 13.5 V at I 1 mAU0, nom 12.5 V at I 10 mAU0, nom 9.0 V at I 20 mA26www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

ELECTRICAL CONNECTIONS 4OPTISONIC 6300 P If the following maximum load resistance RL, max is exceeded, the load resistance RL must bereduced accordingly by parallel connection of R:f 100 Hz: RL, max 47 kΩf 1 kHz: RL, max 10 kΩf 10 kHz: RL, max 1 kΩ The minimum load resistance RL, min is calculated as follows:RL, min (Uext - U0) / ImaxC CDD-Figure 4-4: Pulse frequency output active Pa Any connection polarity. Galvanically isolated.Status output Uext 32 VDC I 100 mA RL, max 47 kΩRL, min (Uext - U0) / Imax open:I 0.05 mA at Uext 32 VDCclosed:U0, max 0.2 V at I 10 mAU0, max 2 V at I 100 mA The output is open when the device is de-energized.Figure 4-5: Status output / limit switch passive Sp03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com27

4 ELECTRICAL CONNECTIONSOPTISONIC 6300 PCurrent input active Uint, nom 15 VDC I 22 mA Imax 26 mA (electronically limited) U0, min 19 V at I 22 mA no HART Not galvanically isolated X designates the connection terminals A or B, depending on the version of the signalconverter.Figure 4-6: Current input active IIna1 Signal2 2-wire transmitter (e.g. temperature)28www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

APPLICATION FORM 5OPTISONIC 6300 PPlease fill in this form and fax or email it to your local representive. Please include a sketch ofthe pipe layout as well, including the X, Y, Z dimensions.Customer informationDateSubmitted byCompanyAddressTelephoneFaxE-mailFlow application dataReference information (name, tag etc)New applicationExisting application, currently using:Measurement imum:Continuous / pulsating flow. Description:Entrained air percentage (volume):Eintrained solids percentage (volume):Emulsion present (e.g. oil / water):Emulsion percentage product A:Emulsion percentage product B:03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com29

5 APPLICATION FORMOPTISONIC 6300 PPiping detailsNominal pipe size:Outer diameter:Wall thickness / schedule:Pipe material:Pipe condition (old / new / painted /internal scaling / exterior rust):Liner material:Liner thickness:Straight inlet / outlet section (DN):Upstream situation (elbows, valves,pumps):Flow orientation (vertical up / horizontal/ vertical down / other):Environment detailsCorrosive atmosphere:Sea water:High humidity (% R.H.)Nucleair (radiation):Hazardous area:Additional details:Hardware requirements:Accuracy requested (percentage ofrate):Power supply (voltage, AC / DC):Analog output (4-20 mA)Pulse (specify minimum pulse width,pulse value):Digital protocol:Options:Remote mounted signal converter:specify cable length:Accessories30www.krohne.com03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en

NOTES 6OPTISONIC 6300 P03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 enwww.krohne.com31

KKK KROHNE 03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en - Subject to change without notice.KROHNE product overview Electromagnetic flowmetersVariable area flowmetersUltrasonic flowmetersMass flowmetersVortex flowmetersFlow controllersLevel metersTemperature metersPressure metersAnalysis productsProducts and systems for the oil & gas industryMeasuring systems for the marine industryHead Office KROHNE Messtechnik GmbHLudwig-Krohne-Str. 547058 Duisburg (Germany)Tel.: 49 (0)203 301 0Fax: 49 (0)203 301 10389info@krohne.deThe current list of all KROHNE contacts and addresses can be found at:www.krohne.com

PRODUCT FEATURES 1 3 OPTISONIC 6300 P 03/2013 - 4000950303 - TD OPTISONIC 6300 P R03 en www.krohne.com 1.1 Portable clamp-on flowmeter The new OPTISONIC 6300 P flowmeter combines mobile, straightforward and quick liquid

Related Documents:

Jul 01, 2016 · JDSU DSAM-6300 xt Specs Provided by www.AAATesters.com. 2 DSAM-6300 DigitAl Service AnAlySiS Meter The level mode on a digital channel measures the signal level and MER and tracks the BER and errored seconds. Signal l evel Meter The DSAM-6300 features extremely accurate JDSU digiCheck digital power

Acme Packet 1100 Acme Packet 3900 Acme Packet 4600 front bezel hides the fan assemblies without restricting airflow through the system. Acme Acme Packet 6100 Acme Packet 6300 Packet 6300 Acme Packet 6350 The rear of Acme Packet 6300 least one slot reserved for an NIU.

400-reading memory allows retrieval of previous data for review connects to leading EHr systems to reduce documentation errors 63XXXX-Bconnex VSM 6300—Blood pressure 63XXPX-Bconnex VSM 6300—Blood pressure, printer 63XTXX-Bconnex VSM 6300—Blo

stackable 6300 switches are part of the Aruba CX switching portfolio, designed for today's enterprise campus, branch and data center networks. By combining a modern, fully programmable OS with the Aruba Network Analytics Engine, the 6300 switches provide industry leading monitoring and troubleshooting capabilities for the access layer.

3 Order . AA-6300 . Burner ASSY . 8. Drain ASSY . 2. Item Part Number Part Name . 1 016-35792-09 Tube, Super-Corn-Ace 206 -50735 93 Level Switch Assy 3 206-63698-00 Drain Bottle

For failover configuration with a Cisco ASA firewall, the 6300-CX must be able to provide a static IP address to the secondary WAN interface (port). It cannot do so, however, until IP Passthrough is disabled on the Accelerated device. Reconfiguring the 6300-CX in this manner places the CX in “Router Mode.” The settings outlined below should be

the API 670 standard for machinery protection systems. The AMS 6300 SIS implemented the stricter development regulations during production to actively ensure compliance. In addition, the AMS 6300 SIS rotational direction detection functi

Introduction to Digital Logic with Laboratory Exercises 6 A Global Text. This book is licensed under a Creative Commons Attribution 3.0 License Preface This lab manual provides an introduction to digital logic, starting with simple gates and building up to state machines. Students should have a solid understanding of algebra as well as a rudimentary understanding of basic electricity including .