Pilot Operated Pressure Relief ValveSeries R5VCatalogue HY11-3500/UKCharacteristicsPilot operated pressure relief valves series R5V have asimilar design to the subplate mounted R4V series. TheSAE flanges allow to mount the valves directly on theoutlet flanges of pumps or inlet flanges of actuators toachieve a very compact design.Valves with SAE flanges can also be bolted together tocombine functions without the need of a manifold block.Features Pilot operated with manual adjustment R5V with 2-port body- 3 sizes (SAE ¾", 1", 1¼")- SAE61 flange R5V with 3-port body- 4 sizes (SAE ¾", 1", 1¼", 1½")- SAE61 and SAE62 flange 3 pressure stages 3 adjustment modes- Hand knob- Acorn nut with lead seal- Cylinder lock With optional vent functionR5V 2-portR5V 2-portR5V 3-portexternal drainR5V 2-portinternal drainR5V 3-portR5V 3-port9SAE61 B-port SAE61SAE62 B-port SAE62R5V UK.INDD CM 03.03.169-2Parker Hannifin CorporationHydraulics Group

Pilot Operated Pressure Relief ValveSeries R5VCatalogue HY11-3500/UKOrdering CodeR5VPressure NominalSAEsizerelief ilot Switching Solenoid Design SealsoiltypevoltageDesign Optionsseries(not requiredfor ordering)Code06081012 1)Port sizeSAE ¾"SAE 1"SAE 1¼"SAE 1½"Code008 5)070SAE61Max. pressure [bar]210280350SAE62CodeSizeMax. pressure [bar]3506 1) 06/08/10/12Code345Size121006/08152 6)2-port bodyCodepilot ports7Y1 G ¼" 2)3-port bodyCodepilot ports9Y1 2), X1, M G ¼"OptionsVent functionwith slow unloadingMetric 3-port bodyfor R5V10 SAE62:Pressure ports (A):SAE62 with 15 mmthrough holes (for M14),Tank port: SAE61 (M12)3-port bodywith metric threadsCode15SealsNBRFPMCodeSolenoid voltageStandard w/o ventfunction12 V 24 V 98 V 205 V 110 V / 50 Hz120 V / 60 Hz230 V / 50 Hz240 V / 60 HzomitG0RG0QGAR 4)GAG 4)W30Code135 3)Pressure stagesup to 105 barup to 210 barup to 350 barCode1AdjustmentHand knobAcorn nutwith lead sealCylinder lockW31Codeomit340911Code26Further options on requestSwitching typeStandard w/ovent functionSolenoid not activated,unpress. circulationSolenoid activatedunpress. circulationPilot oilDrain lineinternalexternal from Y1-port1)Only R5V 3-port.only available at external drain (pilot oil code 6).R5V10-4*5 up to 280 bar.4) To be used in combination with rectifier plugs at 120 VAC / 230 VAC power supply.5) Only for vent valve function code 09.6) R5V08 SAE62: Tank port SAE61 (M10).2) Y13)R5V UK.INDD CM 03.03.169-3Parker Hannifin CorporationHydraulics Group9

Pilot Operated Pressure Relief ValveSeries R5VCatalogue HY11-3500/UKTechnical Data / Characteristic CurvesTechnical data9General06 (¾")08 (1")10 (1¼")12 (1½")SizeMountingFlanged according to SAE61 and SAE62Mounting positionunrestrictedAmbient temperature[ C] -20. 60MTTFD value[years] 75WeightR5V 2-port[kg]4.04.65.9—R5V 3-port[kg]3.64.65.28.0HydraulicMax. operating pressure[bar]SAE61 Ports A, B350350280210Port Y130303030SAE62 Ports A, B350350350350Port Y130303030Pressure stages[bar] 105, 210, 350Nominal flow[l/min]90300600600FluidHydraulic oil according to DIN 51524Fluid temperature[ C] -20. 70 (NBR: -25. 70)Viscosity,permitted[cSt] / [mm2/s] 20 . 400recommended [cSt] / [mm2/s] 30.80FiltrationISO 4406 (1999); 18/16/13Electrical (solenoid)Duty ratio100 % ED; CAUTION: coil temperature up to 150 C possibleProtection classIP65 in accordance with EN 60529 (with correctly mounted plug-in connector)CodeG0RG0QGARGAGW30W31[V]110 at 50 Hz 230 at 50 HzSupply voltage12 V 24 V 98 V 205 V [V]120 at 60 Hz 240 at 60 HzTolerance supply voltage[%] 10 10 10 10 5 5Current consumption hold[A]2.721.290.330.130.6 / 0.550.3 / 0.27in rush[A]2.721.290.330.132.5 / 2.41.25 / 1.2Power consumption hold[W]32.73131.928.270/70 VA70/70 VAin rush[W]32.73131.928.2280/290 VA280/290 VASolenoid connectionConnector as per EN175301-803, solenoid identification as per ISO 9461Wiring min.[mm2] 3 x 1.5 recommendedWiring length max.[m] 50 recommendedp/Q performance curveMinimum pressure curveAll characteristic curves measured with HLP46 at 50 C.The performance curves are measured with external drain.For internal drain the tank pressure has to be added to curve.R5V UK.INDD CM 03.03.169-4Parker Hannifin CorporationHydraulics Group

Pilot Operated Pressure Relief ValveSeries R5VCatalogue HY11-3500/UKDimensionsDimensions R5V 2-port9SAE61NG060810NG060810Seal kitsNBRFPMS16-91850-0 S16-91850-5S16-91851-0 S16-91851-5S16-91852-0 Y1PressureTankExternal L222.226.230.2Port sizeR5V081" SAE611" SAE61G¼"R5V06¾" SAE61¾" " SAE611¼" SAE61G¼"R5V UK.INDD CM 03.03.169-5Parker Hannifin CorporationHydraulics Group

Pilot Operated Pressure Relief ValveSeries R5VCatalogue HY11-3500/UKDimensionsDimensions R5V 3-portNG060810129Seal 58.769.8L363656192.5L4L5d160152 1962149 2568 150.5 3259.2 171.2 38d210.510.512.513.5d319253038d4 (option 152)3/8”-16 UNC (M10)3/8”-16 UNC (M10)7/16”-14 UNC (M12)1/2”-13 UNC 52 1962149 2568 150.5 3259.2 171.2 38d210.512.513.517d319253038d4 (option 152)3/8”-16 UNC (M10)7/16”-14 UNC (M10)1)1/2”-13 UNC (M12)5/8”-11 UNC H323.827.831.836.5PortFunctionA (2)BX1Y1MPressureTankExternal pilot port 2)External drainPressure gaugeH481103113140Port sizeR5V06¾" SAE61/62¾" SAE61/62G¼"G¼"G¼"R5V081" SAE61/621" SAE61/62G¼"G¼"G¼"R5V101¼" SAE61/621¼" SAE61/62G¼"G¼"G¼"R5V121½" SAE61/621½" SAE61/62G¼"G¼"G¼"T-port SAE61.Closed when supplied.R5V UK.INDD CM 03.03.169-6Parker Hannifin CorporationHydraulics Group

Pilot Operated Pressure Relief ValveSeries R5VCatalogue HY11-3500/UKDimensionsDimensions R5V with vent functionSeal kitsNBRFPMDC solenoidS56-40609-0S56-40609-5AC solenoidS26-35237-0S26-35237-5R5V 2-portCodeInternal drainZAX9R5V 3-portExternal drainAZAYInternal drainXAExternal BBY1R5V UK.INDD CM 03.03.169-7Parker Hannifin CorporationHydraulics Group

Weight R5V 2-port [kg] 4.0 4.6 5.9 — R5V 3-port [kg] 3.6 4.6 5.2 8.0 Hydraulic Max. operating pressure [bar] SAE61 Ports A, B 350 350 280 210 Port Y1 30 30 30 30 SAE62 Ports A, B 350 350 350 350 Port Y1 30 30 30 30 Pressure stages [bar] 105, 210, 350 Nominal flow [l/min] 90 300 600 600 Fluid Hydraulic oil according to DIN 51524

Related Documents:

Pilot Operated Pressure Relief Valves Series R4V / R6V 4-21 R4V-R6V UK.indd 30.05.2018 4 Catalogue HY11-3500/UK Parer Hannifin Corporation . 9 R6V Y-port G 1/8" Code Vent valve 09 Solenoid not activ. unpress. circulation 11 Solenoid activated unpress. circulation Pilot oil Code Drain line 0 internal 1 1) external from subplate

Directional Control Valve Series D3W Catalogue HY11-3500/UK Parer Hannifin Corporation Hydraulics Group 2 Shift Limits / Response Times Measured with HLP46 at 50 C, 90 % U nom and warm solenoids. For even softer shifting, the proportional spools 081, 082, 101 and 102 can be used. Code Orifice size Energize De-energize

Maserati- 3500 GT Coupe Touring- Engine 9 Maserati- 3500 GT Coupe Touring- Exhaust 11 Maserati- 3500 GT Coupe Touring- Fuel System 12 Maserati- 3500 GT Coupe Touring- Glass and Seals 13 Maserati- 3500 GT Coupe Touring- Interior 18 Maserati- 3500 GT Coupe Touring- Lights 20 Maserati- 3500 GT Coupe Touring- Luggage Compartment 22

The series of pilot operated servo proportional valves D*1FP transfers the advantages of the Parker patented Voice Coil Drive (VCD ) to larger frame sizes and thus high flow rates. The high dynamics / high precision drive of the pilot valve allows the optimum control of the main spool and results in servo class performance of the complete valves.

125 crf125f/fb je03e 3500 3500 3500 3500 3500 trx250tm/te te21e, te48e 3250 3250 3250 3250 150 CRF150F KE02E 4250 4250 4250 4250 400 TRX400X TE23E 3500 CRF150R*/ RB* KE03E 6250 6250 6250 6250 6250 420 TRX420FA/FPA TE37E 3250

Bently Nevada* Asset Condition Monitoring 3500/05 System Rack . Description . The 3500 System rack design holds all 3500 monitor modules and rack power supplies. It allows the various 3500 modules to communicate with one another and the power supplies to distribute power to each mod ule as required. 3500 Racks are available in two sizes: 1.

3500/61E & 3500/67E Temperature Monitor . Bently Nevada* Asset Condition Monitoring . 3300/35 6. with the I/O modules used for the 3300/36 2. Description . The 3500/61E and 3500/67E modules provide six channels and two channel of temperature monitoring. Both monitors can be ordered to accept Resis tance

Catalyst 3500 XL Cisco Cisco Catalyst 3500 XL 2900 XL Catalyst 1900 & &' IP 380 &' Gigabit Ethernet&' &' Catalyst 3500 XL&' Cisco IOS( Cisco Visual Switch Manager (CVSM) &' Web Cata-lyst 3500 XL&' * &' * 802.1Q ISL VLAN TACACS Uplink Fast Catalyst 3500 XL 3 Cisco GigaStack( Gigbit Interface Converter (GBIC)