Safety Light CurtainF3SG- RE Serieshttp://www.ia.omron.com/f3sg-rQuick Installation ManualDocument TitleSafty Light Curtain F3SG-R Series User's ManualCat. No.Z352-E1 OMRON Corporation 2015-2016 All Rights Reserved.Original instructions8900153-0B

IntroductionThank you for purchasing the F3SG- RE Series Safety Light Curtain (hereinafter referred to as the "F3SGRE"). This document contains simple instructions to install the F3SG-RE.Please download the F3SG-RE User's Manual for full contents of the instructions from our website at:http://www.ia.omron.com/f3sg-rTable of Contents1. What is Included.12. System Components .23. F3SG-RE Setup Procedure Example .24.Wiring Examples .34-1. Long Mode .34-2. Short Mode.35. Mounting and Beam Alignment .45-1. Mounting with Standard Fixed Brackets (F39-LGF).45-2. Mounting with Standard Adjustable Brackets (F39-LGA).66. Operation Check .9Suitability for Use/Contact Information .91. What is IncludedProductF3SG- RE main unitQuantityEmitter x 1, Receiver x 1Standard Fixed BracketThe number of brackets included depends on protective height of the F3SG-RE.Less than 1,280 mm: 2 sets1,280 mm or longer and up to 2,270 mm: 3 sets2,350 mm or longer and up to 2,510 mm: 4 setsTroubleshooting Guide StickerSafety PrecautionsQuick Installation Manual141For ratings/specifications, input/output circuit, LED indicator status and troubleshooting, refer to Safety Light Curtain F3SG-RSeries User's Manual.1F3SG-REQuick Installation Manual

2. System Components Emitter Beam center-line mark Receiver 1. Top-beam-state indicator (Blue)BeamEmitterIndicatorReceiver2. Operating range indicator (Green)Power Cable(Gray)3. Power indicator (Green)9. Internal error indicator (Red)4. Lockout indicator (Red)10. Lockout indicator (Red)11. Stable-state indicator (Green)12. ON/OFF indicator (Green/Red)13. Communication indicator (Green)14. Bottom-beam-state indicator (Blue)Power Cable(Black)Extension cable3. F3SG-RE Setup Procedure ExampleSetupWiring. . . . . . page 3Mounting/Beam Alignment. . . . . . page 4Operation check. . . . . . page 9DoneF3SG-REQuick Installation Manual2

Mounting/Beam AlignmentWiringOperation check4.Wiring ExamplesFor input/output circuit and other examples than below, refer to Safety Light Curtain F3SG-R Series User's Manual.24 VDC : BrownOSSD2 : WhiteOSSD1 : Black0 VDC : Blue24 VDC : BrownNot used : BlackOperating RangeSelect Input : White0 VDC : BlueEmitterReceiver4-1. Long Mode 24 VDCPowerSupply0V*1. Refer to F3SG-R Series User's Manual for more information.*2. The safety controller and the F3SG-RE must share thepower supply or be connected to the common terminal ofthe power supply.IN1IN2SafetyController *1 *224 VDC : BrownOSSD2 : WhiteOSSD1 : Black0 VDC : Blue24 VDC : BrownNot used : Black0 VDC : BlueOperating RangeSelect Input : WhiteEmitterReceiver4-2. Short Mode 24 VDCPowerSupply0V*1. Refer to F3SG-R Series User's Manual for more information.*2. The safety controller and the F3SG-RE must share thepower supply or be connected to the common terminal ofthe power supply.3IN1IN2SafetyController *1 *2F3SG-REQuick Installation Manual

Mounting/Beam AlignmentWiringOperation check5. Mounting and Beam Alignment5-1. Mounting with Standard Fixed Brackets (F39-LGF)Step1 Dimensions (Check position)Checkposition50.35[Backside mounting]Step2Mount150 max2-M5 or M6FA6.46651Standard FixedBracket(F39-LGF)51FDC2 (Protective height for 14 mm)C1 (Protective height for 30 mm)A51Standard FixedBracket(F39-LGF)150 max35403524.852515P150 max150 max2-M5 or M69.224.85 Screw: M5 or M6 [ Unit : mm ]F3SG- RE 30 SeriesF3SG- RE 14 SeriesDimension AC1Dimension AC2 30Dimension C14-digit number of the type name(Protective height)Dimension C24-digit number of the type name(Protective height)Dimension DC1-50Dimension DC2-20Dimension P20Dimension P10Protective height(C1)Number of StandardFixed Brackets *1Dimension FProtective height(C2)Number of StandardFixed Brackets *10190 to 12301310 to 22702 *21000 mm max.0160 to 12002 *21000 mm max.31000 mm max.1280 to 208031000 mm max.2350 to 251041000 mm max.Dimension F*1. The number of brackets required to mount either one of emitter and receiver.*2. Mounting an emitter or receiver with one bracket is possible for the models of protective height of 0160 to 0270. In this case, locatethis bracket at half the Dimension A (or at the center of the sensor length).Refer to Safety Light Curtain F3SG-R Series User's Manual for dimensions of side mounting.F3SG-REQuick Installation Manual4

Mounting/Beam AlignmentWiringOperation check MountingStep1Note: Although this chapter uses the figures of the F3SG-RA series safety light curtain, the mounting procedure of the F3SG-RE series is the same as the F3SG-RA series.1. Loosen the screw.CheckpositionHexagon socket headcap screw (M3 x 15)Fixed BracketStep2hookMount2. Lightely tighten the screw. Backside mounting Side mounting Optical surfaceof F3SG-REOptical surfaceof F3SG-RESlide the hookin the grooveFixed BracketFixed BracketSlide the hookin the groove3. Adjust the mounting position and secure the bracket. Backside mounting Adjust the bracketto mounting position Side mounting Adjust the bracketto mounting positionTightening torque:2.0 N m (recommended)4. Secure the bracket to the wall. Backside mounting Side mounting Screws to mount the brackets to the wall are not included.5F3SG-REQuick Installation Manual

Mounting/Beam AlignmentWiringOperation check5-2. Mounting with Standard Adjustable Brackets (F39-LGA) Dimensions (Check position)Step1[Backside mounting]50.35CheckpositionStep248.635352-M5 or M6Step3AlignbeamsFA2-M5 or M624.85150 max9.224.852515P150 max6.48472Standard AdjustableBracket(F39-LGA)72FDC2 (Protective height for 14 mm)C1 (Protective height for 30 mm)A72Standard AdjustableBracket(F39-LGA)150 max150 maxMount Screw: M5 or M6 [ Unit : mm ]F3SG- RE 30 SeriesF3SG- RE 14 SeriesDimension AC1Dimension AC2 30Dimension C14-digit number of the type name(Protective height)Dimension C24-digit number of the type name(Protective height)Dimension DC1-50Dimension DC2-20Dimension P20Dimension P10Protective height(C1)Number of StandardAdjustable Brackets *1Dimension FProtective height(C2)Number of StandardAdjustable Brackets *1Dimension F0190 to 12302 *21000 mm max.0160 to 12002 *21000 mm max.1310 to 227031000 mm max.1280 to 208031000 mm max.2350 to 251041000 mm max.*1. The number of brackets required to mount either one of emitter and receiver.*2. Mounting an emitter or receiver with one bracket is possible for the models of protective height of 0160 to 0270. In this case, locatethis bracket at half the Dimension A (or at the center of the sensor length).Refer to Safety Light Curtain F3SG-R Series User's Manual for dimensions of side mounting.F3SG-REQuick Installation Manual6

Mounting/Beam AlignmentWiringOperation check Mounting and Beam AlignmentStep1Note: Although this chapter uses the figures of the F3SG-RA series safety light curtain, the mounting procedure of the F3SG-RE series is the same as the F3SG-RA series.1. Loosen the screws and adjust the angle.Checkpositionhexagon socket headcap screw (M3 x 15)hexagon socket headcap screw (M3 x 15)Step2MounthookStep3Alignbeams2. Lightely tighten the screw. Backside mounting Side mounting Optical surfaceof F3SG-REOptical surfaceof F3SG-RESlide the hookin the grooveSlide the hookin the grooveAdjustableBracketAdjustaBracket3. Adjust the mounting position and secure the bracket. Backside mounting Adjust the bracketto mounting position Side mounting Adjust the bracketto mounting positionTightening torque:2.0 N m (recommended)4. Secure the bracket to the wall. Backside mounting Side mounting Screws to mount the brackets to the wall are not included.7F3SG-REQuick Installation Manual

Mounting/Beam AlignmentWiringOperation check5. Perform beam alignment according to the indicators. Emitter Receiver Receiver Receiver ngle adjustment range: 15 6. Securely tighten the remaining screws. Backside mounting Side mounting Tightening torque:2.0 N m (recommended) Enlarged view F3SG-REQuick Installation ManualHexagon socket headcap screw (M3x15)8

WiringMounting/Beam AlignmentOperation check6. Operation CheckAfter wiring, mounting and beam alignment are done, check the operation of the F3SG-RE. Attach theincluded Troubleshooting Guide Sticker nearby, if necessary.For more information, visitTROUBLESHOOTING [EN]BlinkingOFFhttp://www.ia.omron.com/f3sg-rLED INDICATORMAJOR CAUSEError of internal circuitINTERNALLOCKOUTON/OFFBlinking OnceLONGLOCKOUTON/OFF, COM, orINTERNALError of OSSD linesError of Operating Range Select Input lineError of emitterPOWERBlinking TwiceLOCKOUTError due to abnormal power supply or noiseError due to noisePOWERSTBError due to vibration or ambient light8600128-9A(5)Refer to Safety Light Curtain F3SG-R Series User's Manual or the web site for ability forfor UseSuitabilityUse/Contact InformationOmron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to thecombination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicablethird party certification documents identifying ratings and limitations of use which apply to the Product. This information byitself is not sufficient for a complete determination of the suitability of the Product in combination with the end product,machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of theparticular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in allcases.NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUTENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THEOMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALLEQUIPMENT OR SYSTEM.See also Product catalog for Warranty and Limitation of Liability.OMRON CorporationIndustrial Automation Company (Manufacturer)Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 JAPANRegional Headquarters OMRON EUROPE B.V. (Representative and Importer in EU)Wegalaan 67-69, NL-2132 JD HoofddorpTHE NETHERLANDSTel: (31)-2356-81-300 / FAX: (31)-2356-81-388 OMRON SCIENTIFIC TECHNOLOGIES INC.6550 Dumbarton CircleFremont, CA 94555 U.S.A.Tel: (1) 510-608-3400 / Fax: (1) 510-744-1442Contact: www.ia.omron.com OMRON ASIA PACIFIC PTE. LTD.No. 438A Alexandra Road # 05-05/08 (Lobby 2),Alexandra Technopark,Singapore 119967Tel: (65) 6835-3011 / Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD.Room 2211, Bank of China Tower,200 Yin Cheng Zhong Road,PuDong New Area, Shanghai, 200120, ChinaTel: (86) 21-5037-2222 / Fax: (86) 21-5037-2200In the interest of product improvement, specifications are subject to change without notice.9F3SG-REQuick Installation Manual

Dimension F 0190 to 1230 2 *2 1000 mm max. 1310 to 2270 3 1000 mm max. 2350 to 2510 4 1000 mm max. F3SG- RE 14 Series Dimension A C2 30 Dimension C2 4-digit number of the type name (Protective height) Dimension D C2-20 Dimension P 10 Protective height (C2) Number of Standard Fixed Brackets *1 Dimension F 0160 to 1200 2 *2 1000 mm max.

Related Documents:

Hartmann Tensoval Duo Control II Omron HEM-7420 Transtek TMB-1776 Hingmed WBP-02A Hospital Omron HEM-9600T Welch Allyn ProBP 2000 iHealth CardioMed (ABP100) Omron HEM-9601T Withings BP-800 InBody BP170 Omron HEM-9700T Yuwell YE680B InBody BPBIO250 Omron M3 (HEM-7200-E) Yuwell YE690A # 1-Star Blood Pressure Monitors # A&D TM-2420 Microlife BP A100

14 Omron E3Z-LS Photoelectric Switch 15 2 Omron Photoelectric Switch 16 2 Omron Photoelectric Switches 17 3 Omron Proximity Switches 18 Omron Photoelectric Sensor 19 Quantity Pneumatic Fittings, to 3 tubs 20 Quantity various Air Filters, to Bosch, Schroder,

ECG software and technology powered by AliveCor is embedded on the OMRON connect app and is integral part of OMRON Complete blood pressure monitor ECG system. Safety Instructions This instruction manual provides you with important information about the OMRON Complete Automatic

The Klinkmann OMRON Tag Creator is an add-on module for Wonderware InTouch WindowMaker, used to expand the functionality and capability of InTouch at design time. The Omron PLC programs created by the OMRON CX-Programmer Windows

HEM-7322U-E_A_M10_131029.pdf Model M6 Comfort IT Výrobce Zástupce pro EU OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, NIZOZEMSKO www.omron-healthcare.com Výrobní závod OMRON HEALTHCARE UK LTD. Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, U.K. Pobočka Distribuce a servis pro ČR OMRON MEDIZINTECHNIK

Omron offers the 3D robot vision system and robots for picking applications. 3D Robot Vision System. Robot. This system recognizes positions and postures of parts and outputs the position information of parts to the robot. Robots from Omron (TM & Viper Series) and other major vendors can be used. For more information about robots, visit Omron .

For details, refer to the User's Manual (Cat. No. Z339 or Z353). The Connection Procedure Manual for OMRON NJ Series and CJ Series is available. Plus Note : Contact your Omron sales representative for the Connection Procedure Manual.

OMRON Pedometer Model HJ-109 Thank you very much for purchasing the OMRON Pedometer. Please read this Instruction Manual before using the product to ensure safe and correct use. Please keep this Instruction Manual always at hand for your future reference. EN-Cover[HJ-109]-4 1 6/25/03, 2:47 PM.