Auxiliary Assistant Machinery Inspector Performance Qualification Standard

1y ago
5 Views
2 Downloads
649.22 KB
35 Pages
Last View : 1m ago
Last Download : 2m ago
Upload by : Kamden Hassan
Transcription

U. S. Coast Guard SectorAuxiliaryAssistant Machinery InspectorPerformance Qualification StandardRevision Date: 05August 2015

[This page left intentionally blank]Revision Date: 05 August 2015

Sector Training GuideAuxiliary Assistant Machinery InspectorPerformance Qualification StandardQualification Code: AUX-MIThis booklet is one section of your personal on the job training (OJT) manual. It is your OJTguide to qualification as an Auxiliary Assistant Machinery Inspector. It is your responsibilityto document completed unit training items.The AUX-MI qualification is one of several “specific cargo / vessel related” Auxiliary Assistantcommercial vessel examiner competencies. Those members who will be required to assist ininspecting machinery shall complete this PQS workbook.On a limited basis, PQS task items may be “deferred” by your unit commander to accurately addressthe type of vessels / cargo normally examined at your port. If a task is deferred, the reason fordeferment must be clearly articulated in the space provided in this PQS workbook. Task items shallonly be deferred if the particular task item requires a certain type of vessel, vessel system or cargotype that is not normally examined / encountered at the trainee’s port. If a PQS task item is deferred, you will not be authorized to examine / perform the functionrequired by the deferred task item.You will still receive full AUX-MI qualification even if some items are deferred.Domestic Inspection Division Chiefs shall examine tasks of newly reported AUX-MIexaminers to identify any deferred task items necessary for their port.Auxiliarists are prohibited from entering confined spaces. Under no circumstancesshall any Auxiliarist be allowed to do tasks requiring such entry.Verifying Officers shall be experienced and qualified personnel who have demonstrated theability to evaluate, instruct, and observe other personnel in the performance task criteria.Verifying Officers must be certified in the competencies for which they are to verify andmust be Sector command designated. Verifying Officers must enter their title, name, andinitials in the Record of Verifying Officers section before making entries in your workbook.A Verifying Officer shall observe your successful performance of each task and documentsuch with date and initials in the appropriate space provided in this booklet. It may benecessary to perform a task several times. The Verifying Officer will not give credit for anytask that is not performed satisfactorily.Auxiliarists do not have law enforcement authority. They cannot independently exerciseCOTP, OCMI, FMSC or FOSC authority and may become personally liable for actions theytake outside of prescribed directives. Do not allow an Auxiliarist to be placed in aposition that will compromise the limitations on the member’s authority.When you have completed all of the items required for this qualification, your COTP willissue a Letter of Designation. You must forward a copy of your Letter of Designation toyour DIRAUX for entry into AUXDATA. Should any item be waived the qualification isconsidered local and will not be entered into AUXDATA and may not be used towardqualification for the Trident device.Revision Date: 05 August 2015

Auxiliary Assistant Machinery Inspector[This page left intentionally blank]Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorRECORD OF COMPLETIONTraining PrerequisitesA. Completion of resident training course (Optional):DateVerifying Officer’s Signature1. Marine Inspector Course2. SMI Machinery CourseB. Completion of correspondence courses:1. Introduction to Marine Safety andEnvironmental Protection (IMSEP)2. ICS 1003. ICS 2004. ICS 210 or ICS 3005. IS 7006. IS 800C. Favorable DO PSI if required by COTP/OCMID. Completion of PQS Workbook.E. Successful completion of unit level oral board.F. Designation Letter submitted for approval.RECORD OF VERIFYING OFFICERSDateTitleRevision Date: 05 August 2015Verifying Officer’s NameInitials

Auxiliary Assistant Machinery Inspector[This page left intentionally blank]Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskCompletedAUX-MI Master �srepresentative.CD04CD05 Obtain CG-2692 for reportable marine casualties.CD06 Examine gas-free certificate.Review any outstanding CG-835s and ask if otherCD08deficiencies exist.Inspect switchboards.ES01Inspect ship’s service generators.ES02Inspect emergency generators.ES04Inspect battery installation.ES05Inspect motor controllers.ES07Ensure lighting systems/fixtures are adequate and meetES08requirements.Ensure receptacle outlets are properly grounded.ES10Inspect distribution panels.ES11Inspect electrical cable installation.ES13Test power operated watertight doors from local/remoteES15control units.Test/inspect internal communication and control systems.ES16Inspect components installed in designated hazardousES18locations.Inspect the general alarm system emergency batteries.ES21Perform operational test of remote ventilation shutdowns.ES22Determine amount, type, location of fire protectionFF01equipment required.Inspect semi-portable firefighting equipment.FF08Inspect portable firefighting equipment.FF09Inspect fire main and fire stations.FF10Witness operational test of fire detection system.FF13Verify that required forms, placards and notices are posted.FP01Verify that the International Safety Management CodeFP04Safety Management system is properly implementedaboard the vessel.GH07 Inspect paint lockers.GH08 Inspect ladders, railways, and gangways.Inspect life preservers.LS04Inspect immersion suits.LS08Determine condition of the components of the steering gearMI01Revision Date: 05 August 2015Defer

Auxiliary Assistant Machinery T04PP03WI01WI03WI04WI06WR01WR02AUX-MI Master Tasksassembly.Inspect fuel oil service and transfer system.Inspect bilge pumps installation, piping, and valves inmachinery spaces.Examine refrigeration/air conditioning machinery.Examine potable water system.Observe operational tests of machinery.Inspect the diesel installation and assembly.Inspect air starting systems.Inspect hydraulic starting systems.Inspect electric starting systems.Witness operational test of main propulsion dieselautomation.Internally examine UPVs requiring internal examination.Externally examine UPVs.Witness Hydrostatic test of UPV.Ensure all UPVs are properly equipped with pressure reliefvalves.Witness pressure relief valve test.Conduct an examination of an auxiliary/heating boiler.Ensure insulation on steam piping provided to reducepersonnel hazard.Witness dye penetrant NDT in accordance with applicablestandards.Witness magnetic particle NDT in accordance withapplicable standards.Witness radiography NDT in accordance with applicablestandards.Witness ultrasonic NDT in accordance with applicablestandards.Inspect pollution prevention equipment and documentationin machinery spaces.Inspect watertight doors.Test power-operated watertight doors from local/remotecontrol units.Inspect watertight bulkhead penetrations.Inspect remote-operated valves and controls.Evaluate welding repair proposal.Complete initial visual inspection of weld repair.Revision Date: 05 August 2015CompletedDateDefer

Auxiliary Assistant Machinery InspectorTaskAUX-MI Master TasksNumberWR03 Complete intermediate visual inspection of weld repair.WR04 Complete final visual inspection of weld repair.WR05 Witness pressure testing of welded repairs.Complete steps to approve Weld Procedure Specification(WPS) for engineering and cargo system construction orWR06repair IAW Subchapter F of the Code of FederalRegulations.Complete steps to approve Weld PerformanceQualifications (WPQ) for engineering and cargo systemWR07construction or repair IAW Subchapter F of the Code ofFederal Regulations.Review approved Weld Procedure Specification (WPS) forWR08engineering and cargo system construction or repair.Review approved Welder Performance QualificationWR09 (WPQ) for engineering and cargo system construction orrepair.Revision Date: 05 August 2015CompletedDateDefer

Auxiliary Assistant Machinery erCompDeferComments aboutDefermentCD04Discuss scope of inspection with owner’srepresentative. Decide on general sequenceof inspection. CD05Obtain CG-2692 for reportable marinecasualties/ structural failure report. CD06Examine gas-free certificate issued by anNFPA-certified marine chemist for hot workand/or confined space entry. Information on the gas-free certificatemeet the requirements of NFPAStandard 306 and Coast Guard confinedspace entry/benzene exposure policy Gas-free certificate been maintained bya designated competent person andrecords kept as required by OSHAregulations Marine chemist certified by NFPA Review benzene and confined spaceentry policies OSHA Competent Person log up to date Meters used by OSHA CompetentPerson are calibrated CD08Review any MISLE inspection notes andoutstanding deficiencies (CG-835s). Askowner's representative if any other Revision Date: 05 August 2015

Auxiliary Assistant Machinery erCompDeferdeficiencies exist.Comments aboutDefermentES01Inspect switchboards. Nonconductive mat on deck in front ofboard Nonconductive rails on board face Nonconductive rails at the rear andsides Dripshield on the board’s top Ground detection indicators workingwith no grounds indicated Meters calibrated and working Synchronizing controls working. Identification for controls and meters Area is dry and clean Working space is provided inaccordance with regulations Overcurrent protection properly labeled ES02Inspect ship’s service generators. Generators of a size or arrangementwhich require overspeed trips Operational test of overspeed trips andalarms within specified limits If the DC or AC generators operate inparallel, are the reverse power/currenttrips working Guards installed around rotating or livemachinery Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask ation from overheatingapparentFilters on air intakes working to keepinternals free from dust and dirtWindings oily or dirtyOdd bearing noises presentVoltage regulated within limitsspecified by CFRWorking diesel low lube oil pressuretrip and alarmsWorking high temperature detectors andalarms for AC generatorsNameplates properly in placeInspect emergency generator. Means of starting is provided The following alarms/shutdowns areoperable: Low lube oil pressure High cooling water temperature Overspeed Fixed firefighting system shutdown The generator auto-start circuitfunctions and the generator can powerits full-rated load within 20 seconds andaccept the final emergency load within45 seconds of loss of the normal powersupply Emergency Generator is tested underload. Independent fuel supply is provided,Revision Date: 05 August 2015Comments aboutDeferment

Auxiliary Assistant Machinery erCompDeferwith remote shut-off valve installed andproperly markedComments aboutDefermentES05Inspect emergency batteries. Size of installation and requiredventilation Battery box is properly lined Batteries are secure in the trays Adequate space provided over the cells A means of charging is provided Conductor overcurrent protection isprovided Ventilation/charger interlocked ES07Inspect motor controllers. Units are installed in suitable cases, or ifopen type, within limited accessenclosure Wearing parts are accessible Controls are marked for each motorserved Wiring diagram is affixed to thecontroller enclosure Motor controllers are dripproof/watertight ES08Ensure lighting systems and fixtures areadequate and meet regulations. Passageways and public areas Machinery spaces Passenger and crew spaces Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask DateCompletedVerifyingOfficerCompDeferComments aboutDefermentBerth lightsExit lightsPilot laddersNavigationSignaling lightsLifeboat and liferaft embarkationstationsES10Ensure receptacle outlets have groundingpoles and are properly grounded. ES11Inspect distribution panels. Circuit directory provided Amperage ratings of the protectivedevices in accordance with requiredcircuit directory Panelboard blanks installed, wherenecessary ES13Inspect electrical cable installation anddetermine: Vertical and horizontal supportsproperly spaced Radius of the bends exceed CFRspecifications Portable cables used for unauthorizedpurposes Acceptable materials used Hazardous conditions exist (jury rigs, Revision Date: 05 August 2015

Auxiliary Assistant Machinery erCompDeferdead end cables, splices, etc.)Comments aboutDefermentES15Test power-operated watertight doors fromlocal and remote control units. ES16Test internal communication and controlsystems and ensure the following systemswork properly. General alarms (bells and contractors) Sound powered phones to all requiredstations Engine order telegraph and wrongdirection alarm Public address system Engineer’s assistance needed alarm Engineer’s call system Fire detection/fire alarm system Refrigerated space alarm system ES18Inspect components installed in designatedhazardous locations and ensure explosionproof installation. Fuel purifier rooms Paint locker Cargo area Pumprooms ES21Inspect the general alarm system emergencybatteries. Revision Date: 05 August 2015

Auxiliary Assistant Machinery erCompDeferComments aboutDefermentES22Inspect ventilation systems and performoperational test of alarms and remoteventilation shutdowns. FF01Determine amount, type and location of fireprotection equipment required. By the vessel’s Certificate of Inspection By the respective regulations FF08Inspect semi-portable fire fightingequipment. Installation approved System serviceable Instructions posted Correct type and amount on hand Markings correct FF09Inspect portable firefighting equipment. Fire extinguishers approved Each unit serviceable Adequate spare charges provided Correct type and amount on hand Distributed per fire control plan Markings correct Servicing properly logged FF10Inspect fire main and fire stations. Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask FF13DateCompletedVerifyingOfficerCompDeferCorrect number of fire pump(s)providedFire hoses meet acceptable standardsEquipment provided at each requiredfire station pursuant to regulationsRequirements for hose length and sizeat each fire station complied withFire pump(s) capable of providingadequate pressure to highest and mostremote fire station using pitot tubePressure gauge installed on dischargeside of fire pumpFire hoses serviceable after hydrotestingValves at fire stations operableFire main(s), hose(s), and equipmentcompatible at each stationApproved nozzles and applicatorsprovided for each fire stationFire pump relief valve functionsproperlyMarkings correctWitness operational test of fire detectionsystem. System serviceable All sensors free of obstructions andfunctioning Alarms and indicators functioningcorrectly Required instructions and diagramsRevision Date: 05 August 2015Comments aboutDeferment

Auxiliary Assistant Machinery InspectorTaskNumberTask ings correctComments aboutDefermentFP01Verify that the required forms, placards, andnotices are posted. Pollution/MARPOL:o Placardo Waste management plan Coast Guard forms:o CG-809: Station bills, drillso CG-811: Lifesaving signals andinstructionso CG-841: Certificate of Inspectiono CG-848: Station Billo CG-2832: Vessel InspectionRecordo CG-3372: Oil Pollution Passenger notices Plans posted:o General arrangemento Fire control plan Rules and regulations for class of vessel SOLAS certificates Markings: conspicuous and legible FP04Verify that the International SafetyManagement Code Safety Managementsystem is properly implemented aboardthe vessel. Designated Person Ashore Maintenance program for vitalequipment Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask DateCompletedVerifyingOfficerCompDeferComments aboutDefermentSafety and Environmental PolicyRecord keepingMaster’s Review and AuthorityClearly defined companyresponsibilities and authorityGH07Inspect paint lockers. Required fire protection equipmentprovided in accordance with applicableregulations and vessel’s approved firesafety plan Space(s) designated constructed of orwholly lined with metal Space(s) well vented and meansprovided to secure ventilation ifnecessary GH08Inspect ladders, rails and gangways. An approved pilot ladder provided andmaintained in good repair Accommodation ladder of sufficientsize provided to be used when distancefrom sea level to vessel’s deck is morethan 30 feet “Rails” are provided on accommodationladders, when used LS04Inspect life preservers. Properly equipped with lights, whistlesand reflective tape Approved for intended service Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask DateCompletedVerifyingOfficerCompDeferComments aboutDefermentSufficient serviceable units aboard andproperly stowedProperly markedLS08Inspect immersion suits. Equipped as required Physically serviceable Sufficient number of units aboard andproperly stowed MI01Determine condition of the followingcomponents of the steering gear assembly: Insides of motor controller and switchgear boxes Mounting bolts for all equipment(vibration) attachments, links and pins Freedom of movement and absence ofany friction noises on motors andpumps Cleanliness of space (absence offire/personnel hazards) Evidence of saltwater leakage throughrudder post packing or vent ducts MI04Inspect fuel oil service and transfer system. Determine condition of piping andmanifolds Determine condition of fuel oil HP andLP strainers Ensure fuel oil pump relief pump valvesdischarge to suction side of fuel oil Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask DateCompletedVerifyingOfficerCompDeferpumpsEnsure no excessive fuel oil leakageexistsWitness operation of fuel oil pumpsEnsure instrumentation is operableExternally examine fuel oil heatersTest remote operated fuel oil systemvalvesDetermine condition of fuel oil tankvent lines and flame screensComments aboutDefermentMI06Inspect bilge pumps installation, piping, andvalves in machinery spaces. System capable of pumping from anywatertight compartment except ballast,oil and water tanks Standing water drains to suction pipes Bilge manifold has independent bilgesuction control and is properly marked Suction strainers are installed Emergency bilge suction installed,where required Instrumentation operable MI10Examine refrigeration/air conditioningmachinery. Rotating machinery guards Piping Wiring Pressure vessels Revision Date: 05 August 2015

Auxiliary Assistant Machinery erCompDeferComments aboutDefermentMI11Examine potable water system. Dedicated tanks; treated or coated Tanks ventilated with insect screensinstalled Water pump(s) and pressurizationsystem operable Pressure tank installation MI13Determine what prime mover operationaltests are required; witness tests and state ifresults are satisfactory. Overspeed trips Low lube oil shutdowns and alarms High coolant temperature alarm MI16Inspect the main diesel installation andassembly, paying particular attention to thefollowing: Crankcase explosion covers Fuel and lube oil fittings (checking forleakage) Instrumentation Gratings and rails around the engine Guards over rotating machinery Exhaust system:o Leakso Lagging (not oil soaked)o Proximity of combustible materialor walkwayso Water cooling systemo Bulkhead penetrations Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask DateCompletedVerifyingOfficerCompDeferEngine foundations and tank top’sstructural conditionAir intakesCrankcase vents (clear)Comments aboutDefermentMI19Inspect air starting systems. Air receivers Piping Compressors MI20Inspect hydraulic starting systems. Pumps and strainers Piping Accumulators MI21Inspect electrical starting systems. MI22Witness operational test of main propulsiondiesel automation system. Determine that the system has not beenmodified/jury rigged and is the same asthat depicted in the procedures Testing the automation system using themethods specified by approvedprocedure Verify that automatic systems have notbeen bypassed or overridden by manualdevices except as noted in approved test Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask ify proper operation of requiredalarms, shutdowns, controls and internalcommunications in accordance with theapproved test procedureVerify that bridge controls/alarmsfunction in sync with engineroomcontrol panelo Based on automation systemtesting, assess if vessel manningremains consistent withregulation/policies and determinecorrective action, if necessary:o Temporary increase of engineroommanningo Further underway evaluationComments aboutDefermentMI25Internally examine unfired pressure vesselsrequiring internal examination. Check for corrosion, scale, pitting,cracks and erosion Examine welded connections internally MI26Externally examine unfired pressure vessels. Pressure gauge Evidence of structural damage Data plate legible Foundations structurally sound Attachments secure MI27Witness Hydrostatic test of unfired pressure Revision Date: 05 August 2015

Auxiliary Assistant Machinery erCompDefervessel. Determine when hydrostatic testrequired Determine MAWP Observe pressure testComments aboutDefermentMI28Ensure all unfired pressure vessels areproperly equipped with pressure reliefvalves. MI29Witness pressure relief valve test. MAWP not exceeded Valve seats tightly Spring set within range Correct valve type Hand lifting device MI33Conduct an examination of anauxiliary/heating boiler. Furnace (distortion) Combustion chamber (crown sheet,wrapper sheet, back sheets (distortion) Boiler shell and heads Stay bolts Boiler saddles and foundations Plating in way of mountings (wastagedue to leaking valves and fittings) Cracks in the plating due to flexing ofthe heads or leakage Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask DateCompletedVerifyingOfficerCompDeferComments aboutDefermentWastage around manhole gasketsNote heat number and condition offusible plugsWaterside tubes (Pitting - determinegeneral depth and tube type)Waterside internal surface conditions(scaling, pitting, corrosion, erosion)Mountings opened/removedSafety valve operationWitness hydrostatic testMI40Ensure insulation is provided to reducepersonnel hazard. NT01Witness dye penetrant NDT in accordancewith applicable standards. Approve NDT method for specificapplications. Determine acceptability of technician'squalification. Evaluate results. NT02Witness magnetic particle NDT inaccordance with applicable standards. Approve NDT method for specificapplications. Determine acceptability of technician'squalification. Evaluate results. Revision Date: 05 August 2015

Auxiliary Assistant Machinery erCompDeferComments aboutDefermentNT03Witness radiography NDT in accordancewith applicable standards. Approve NDT method for specificapplications. Determine acceptability of technician'squalification. Evaluate results. NT04Witness ultrasonic NDT in accordance withapplicable standards. Approve NDT method for specificapplications. Determine acceptability of technician'squalification. Evaluate results. PP03Inspect pollution prevention equipment anddocumentation in machinery spaces. Slop tank provided and located inaccordance with regulations Pump, fixed, or portable pipingsystem(s), valve(s), and controls, as theregulation apply to vessel in question,are provided to remove dirty oil andbilge slops Pump, fixed piping, valve(s), andcontrols are provided for combined fueland ballast tank(s) as needed and wherespecified by regulation Oily water separator installed properlyand functions correctly Oil discharge prohibition placard is Revision Date: 05 August 2015

Auxiliary Assistant Machinery erCompDeferplaced at the bilge and ballast manifoldand/or in each machinery spaceComments aboutDefermentWI01Inspect watertight doors. Knife edges intact and in good repair;no excessive paint buildup Gasket material installed in channel isin good condition and not painted Knife edges and channel meet asdesigned when door closed Hinges and hinge bolts in goodcondition; no sagging of door due torounded out hinges or worn hinge bolts Dogs are all operable; grease fittingsstill usable Dogging wedges not excessively wornand fit up satisfactory Quick-closing gear operable andadequate closure achieved Any port lights installed in watertightdoors use wire mesh reinforced glass Dogging wrench provided in vicinity ofwatertight door(s) WI03Test power-operated watertight doors fromlocal and remote control units. WI04Inspect watertight bulkhead penetrations. Penetrations properly sealed to maintain Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask DateCompletedVerifyingOfficerCompDeferwatertight integrity through use ofdevices such as stuffing tubesSealant used, if stuffing tubes areemployed, is non-flammable productdesigned for such use and is approvedComments aboutDefermentWI06Inspect remote-operated valves and controls. Each valve identified as to functioneither by tag affixed to handle or byindependent means Each valve adequately lubricated andfreely operated Reach rods and other manual remotecontrol mechanisms function properly Each power-operated valve can beoperated from control stations An adequate means of control isprovided to secure valves on fuel andlube oil lines to prevent pollutionincident WR01Evaluate welding repair proposal. Plan or sketch submitted with bill ofmaterials Configuration of repair acceptable Material specification same as existingor equivalent Method of joining acceptable WR02Complete initial visual inspection of weld Revision Date: 05 August 2015

Auxiliary Assistant Machinery erCompDeferrepair. Examine fit up in accordance withapproved weld procedures Examine joint preparation in accordancewith approved weld procedures Verify materials (base, filler, gas) inaccordance with approved weldprocedures Verify proper preheat temperature/time in accordance with approved weldprocedures Evaluate weather conditions Check welding equipment inaccordance with approved weldproceduresComments aboutDefermentWR03Complete intermediate visual inspection ofweld repair. Check back gouging for full penetrationweld Check proper cleaning between weldpasses Check interpass temperatures inaccordance with approved procedures Verify that proper weld sequencing isfollowed Evaluate weather conditions WR04Complete final visual inspection of weldrepair. Perform dry search to ensure welding Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorTaskNumberTask DateCompletedVerifyingOfficerCompDefercomplete and followed weld detailsPerform surface inspection of welds fordefectsVerify proper postheat temperature/timein accordance with approved weldproceduresComments aboutDefermentWR05Witness pressure testing of welded repairs. Witness hose testing Witness air testing Witness hydrostatic testing WR06Complete steps to approve Weld ProcedureSpecification (WPS) for engineering andcargo system construction or repair IAWSubchapter F of the Code of FederalRegulations. Witness WPS test coupon fit forwelding Review coupon test results Draft WPS approval WR07Complete steps to approve WelderPerformance Qualification (WPQ) forengineering and cargo system constructionor repair IAW Subchapter F of the Code ofFederal Regulations. Witness WPS test coupon fit forwelding Review coupon test results Draft WPS approval Revision Date: 05 August 2015

Auxiliary Assistant Machinery erCompDeferComments aboutDefermentWR08Review approved Weld ProcedureSpecification (WPS) for engineering andcargo system construction or repair. Determine suitability of WPS forapplication Determine suitability of third partyWPS acceptance WR09Review approved Welder PerformanceQualification (WPQ) for engineering andcargo system construction or repair. Determine suitability of WPS forapplication Determine suitability of third partyWPS acceptance Revision Date: 05 August 2015

Auxiliary Assistant Machinery InspectorDATELOCATIONVESSELNAMERevision Date: 05 August 2015VESSELCLASSINSPECTIONLEADTYPEINSPECTOR

Auxiliary Assistant Machinery InspectorNOTESRevision Date: 05 August 2015

SAMPLE LETTER OF DESIGNATIONCommand’s NameStreet AddressCity, State Zip CodeStaff Symbol:Phone:Email:1601DATEMEMORANDUMFrom:I. M. Frank, CAPTUnit’s NameReply toAttn of:To:M. O. Ore, USCG AuxiliarySubj:DESIGNATION AS AUXILIARY ASSISTANT MACINERY INSPECTORRef:Auxiliary Assistant Machinery Inspector Performance Qualification Standard Workbook1. Congratulations! You have compl

Inspect bilge pumps installation, piping, and valves in machinery spaces. MI10 Examine refrigeration/air conditioning machinery. MI11 Examine potable water system. MI13 Observe operational tests of machinery. MI16 Inspect the diesel installation and assembly. MI19 Inspect air starting systems. MI20 Inspect hydraulic starting systems.

Related Documents:

a single inspector or major projects requiring hundreds of quality inspectors Office Administrator NACE Coating Inspector E&I Inspector Safety/Environmental Inspector Tank Inspector (non-certified) Mechanical/Civil Inspector Utility Inspector Specialized Inspectors NDE Inspectors * API 1169 prep courses offered

Auxiliary Views Learning Objectives: 9Determine the need for an Auxiliary View. 9Construct each of the three classifications of Auxiliary Views. 9Identify the three classifi cations of Auxiliary Views. 9Define key terms. 9Cut Auxiliary sections. 9Understand and demonstrate the concept of Auxiliary Views on worksheets and CAD drawings. Drafting/CAD 1 - Mr. Mandl

Office of Inspector General NSF Grants Conference. March 1, 2016. Ginna Ingram. Investigative Attorney. Office of Inspector General. National Science Foundation. Who We Are. Assistant Inspector General for Investigations. Assistant Inspector . Hotline: 1-800-428-2189

United States Coast Guard Auxiliary Figure 4. Standard for Flight Suits for Auxiliary Aviation Coast Guard Auxiliary Flight Suit Patch Coast Guard or Auxiliary District or C.G. Air Station 500 HOURS Participation Patch, if awarded Auxiliary Office Sew-on Insignia (optional) American Flag 2.25” x 3.5” (apx) Pilot/Aircrew - Wings

Auxiliary Spillway Layout . C3D How to NRCS Iowa 1 6/30/2017 . Auxiliary Spillway Layout Using the NRCS Tool . Overview: Create the surface model and earthwork volumes for the auxiliary spillway component of a pond embankment. The auxiliary spillway surface will tie into the embankment slope

Factories & Boilers (Hq.), Senior Inspector of Factories & Boilers and T.A. to Chief Inspector of Factories Boilers, Dy. Chief Inspector of Factories (Chemical), Inspector of Factories (Medical), Senior Legal Officer, Accounts Officer, Private Secretary and their complement staff. Office of the Chief Inspector o

4. The Office of the Inspector General's Overall Rating of the Department's Handling of Its Use-of-Force Incidents 12 5. Total Complaints the Office of the Inspector General Received Over the Past Five Years, From 2016 Through 2020 15 6. Total Number of Mail Complaints the Office of the Inspector General Received Each Month During 2020 16 7.

transactions: (i) the exchange of the APX share for EPEX spot shares, which were then contributed by the Issuer to HGRT; (ii) the sale of 6.2% stake in HGRT to RTE and (iii) the sale of 1% to APG. The final result is that the Issuer has a participation in HGRT of 19%. For information regarding transactions (i) and (ii) please refer to the press release dated 28 August 2015 (in the note 4 pp .