S15C Modbus Master To IO-Link Device For Vibration And Temperature

1y ago
14 Views
2 Downloads
735.01 KB
5 Pages
Last View : 13d ago
Last Download : 3m ago
Upload by : Randy Pettway
Transcription

S15C Modbus Master to IO-Link DeviceConverter for Vibration and TemperatureDatasheet Compact ModBus master to IO-Link device converter for use withQM30VT2 Vibration and Temperature sensorPredefined ModBus registers are sent over IO-Link automaticallyRugged over-molded design meets IEC IP65, IEC IP67, and IEC IP68Connects directly to a sensor or anywhere in-line for ease of useModelsHousingFunctionS15CC ConverterFemale-MVT-MVT Modbus Vibration TemperatureMaleConnectorKQK IO-LinkQ Integral M12/Euro-style quick disconnectIO-Link IO-Link is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automaticallyparameterize sensors or lights and to transmit process data. For the latest IO-Link protocol and specifications, please visit www.iolink.com.For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com.Process Data In (Device to Master)The S15C converter provides for the reading of three user-selectable sets of 15 Modbus Registers.For more information, see Banner P/N 210732 Sure Cross QM30VT2 Vibration and Temperature Sensor, Banner P/N 217177S15C Modbus Converter (Vibration and Temperature) - IO-Link Data Reference Guide, and Banner P/N 217160 S15C-MVT-KQIODD Files.RegSet 0Register Set 0 reads the following Modbus Registers with Imperial System values as applicable:RegSet 0Reg Adr 0145201Z-Axis RMS Velocity (in/sec)Reg Adr 0245203Temperature ( F)Reg Adr 0345205X-Axis RMS Velocity (in/sec)Reg Adr 0445207Z-Axis RMS Peak Acceleration (G)Reg Adr 0545208X-Axis RMS Peak Acceleration (G)Reg Adr 0645209Z-Axis Peak Velocity Component Frequency (Hz)Reg Adr 0745210X-Axis Peak Velocity Component Frequency (Hz)Reg Adr 0845213Z-Axis KurtosisReg Adr 0945214X-Axis KurtosisReg Adr 1045215Z-Axis Crest FactorReg Adr 1145216X-Axis Crest FactorReg Adr 1245217Z-Axis Peak Velocity (in/sec)Reg Adr 1345219X-Axis Peak Velocity (in/sec)Reg Adr 1445221Z-Axis High-Frequency RMS Acceleration (G)Reg Adr 1545222X-Axis High-Frequency RMS Acceleration (G)Original Document217586 Rev. C17 September 2020217586

S15C Modbus Master to IO-Link Device Converter for Vibration and TemperatureRegSet 1Register Set 1 reads the following Modbus Registers with Metric System values as applicable:RegSet 1Reg Adr 0145202Z-Axis RMS Velocity (mm/sec)Reg Adr 0245204Temperature ( C)Reg Adr 0345206X-Axis RMS Velocity (mm/sec)Reg Adr 0445207Z-Axis RMS Peak Acceleration (G)Reg Adr 0545208X-Axis RMS Peak Acceleration (G)Reg Adr 0645209Z-Axis Peak Velocity Component Frequency (Hz)Reg Adr 0745210X-Axis Peak Velocity Component Frequency (Hz)Reg Adr 0845213Z-Axis KurtosisReg Adr 0945214X-Axis KurtosisReg Adr 1045215Z-Axis Crest FactorReg Adr 1145216X-Axis Crest FactorReg Adr 1245218Z-Axis Peak Velocity (mm/sec)Reg Adr 1345220X-Axis Peak Velocity (mm/sec)Reg Adr 1445221Z-Axis High-Frequency RMS Acceleration (G)Reg Adr 1545222X-Axis High-Frequency RMS Acceleration (G)RegSet 2Register Set 2 reads the following Modbus Registers specific to sensor information:RegSet 2Reg Adr 0144101Serial Number UpperReg Adr 0244102Serial Number LowerReg Adr 0344103Model Number UpperReg Adr 0444104Model Number LowerReg Adr 0544105Production Date UpperReg Adr 0644106Production Date LowerReg Adr 0744301RF Firmware Part Number UpperReg Adr 0844302RF Firmware Part Number LowerReg Adr 0944303RF Firmware Version UpperReg Adr 1044304RF Firmware Version LowerReg Adr 1144305RF Firmware Version EngineeringReg Adr 1244306RF EEPROM Part Number UpperReg Adr 1344307RF EEPROM Part Number LowerReg Adr 1444308RF EEPROM Version UpperReg Adr 1544309RF EEPROM Version LowerWiring DiagramsFemaleMale23214142PinWire .com - Tel: 1 888 373 6767P/N 217586 Rev. C

S15C Modbus Master to IO-Link Device Converter for Vibration and TemperatureFemale (Sensor)Signal DescriptionPin 118 V DC to 30 V DCPin 2RS485/D1/B/ Pin 3GroundPin 4RS485/D0/A/-Male (IO-Link Master)Signal DescriptionPin 118 V DC to 30 V DCPin 2Banner-specificPin 3GroundPin 4IO-LinkStatus IndicatorsPower LED Indicator (Green) Solid Green Power On Off Power OffIO-Link Communication LED Indicator (Amber) Flashing Amber (900 ms On, 100 ms Off) IO-Link communications are active Off IO-Link communications are not presentModbus Communication LED Indicator (Amber) Flashing Amber (4 Hz) Modbus communications are active Solid Amber for 2 seconds to Off Modbus communications are lost after connection Solid Amber for 2 seconds to Flashing Amber (4 Hz) Modbus communications momentarily lost, but communicationreestablished Solid Amber Modbus communications are intermittent, or communications error occurs more frequently than once every2 seconds Off Modbus communications are not presentSpecificationsSupply Voltage18 V DC to 30 V DC at 50 mA maximumSupply Protection CircuitryProtected against reverse polarity and transient voltagesLeakage Current Immunity400 µAIndicatorsGreen powerAmber IO-Link communicationsAmber ModBus communicationsEnvironmental RatingIEC IP65, IEC IP67, IEC IP68NEMA/UL Type 1Operating ConditionsTemperature: –40 C to 70 C (–40 F to 158 F)90% at 70 C maximum relative humidity (non-condensing)Storage Temperature: –40 C to 80 C (–40 F to 176 F)Required Overcurrent ProtectionWARNING: Electrical connections must bemade by qualified personnel in accordance withlocal and national electrical codes andregulations.ConnectionsIntegral male/female 4-pin M12/Euro-style quick disconnectConstructionCoupling Material: Nickel-plated brassConnector Body: PVC translucent blackVibration and Mechanical ShockMeets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mmamplitude, 5 minutes sweep, 30 minutes dwell)Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sinewave)CertificationsP/N 217586 Rev. COvercurrent protection is required to be provided by end productapplication per the supplied table.Overcurrent protection may be provided with external fusing or via CurrentLimiting, Class 2 Power Supply.Supply wiring leads 24 AWG shall not be spliced.For additional product support, go to www.bannerengineering.com.Supply Wiring (AWG)Required Overcurrent Protection neering.com - Tel: 1 888 373 67673

S15C Modbus Master to IO-Link Device Converter for Vibration and TemperatureDimensionsAll measurements are listed in millimeters [inches], unless noted otherwise.57.8[2.27]27.9[1.1]15.0[0.59]M12 X 1 - 6HM12 X 1 - 6gAccessoriesCordsets4-Pin Threaded M12/Euro-Style Cordsets—Double EndedModelLengthMQDEC-401SS0.31 m (1 ft)MQDEC-403SS0.91 m (2.99 ft)MQDEC-406SS1.83 m (6 ft)MQDEC-412SS3.66 m (12 ft)MQDEC-420SS6.10 m (20 ft)MQDEC-430SS9.14 m (30.2 ft)MQDEC-450SSStyleDimensionsPinoutFemaleMale Straight/Female Straight34M12 x 1ø 14.5 [0.57"]44 Typ.[1.73"]M12 x 1ø 14.5 [0.57"]15.2 m (49.9 ft)2140 Typ.[1.58"]Male23141 Brown2 White3 Blue4 BlackBanner Engineering Corp Limited WarrantyBanner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following thedate of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the timeit is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage orliability for misuse, abuse, or the improper application or installation of the Banner product.THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED(INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE),AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENTSHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS,EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROMANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT ORWARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming anyobligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, orimproper application or installation of this product or use of the product for personal protection applications when the product isidentified as not intended for such purposes will void the product warranty. Any modifications to this product without prior expressapproval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject tochange; Banner reserves the right to modify product specifications or update documentation at any time. Specifications andproduct information in English supersede that which is provided in any other language. For the most recent version of anydocumentation, refer to: www.bannerengineering.com.For patent information, see eering.com - Tel: 1 888 373 6767P/N 217586 Rev. C

S15C Modbus Master to IO-Link Device Converter for Vibration and TemperatureFCC Part 15 and CAN ICES-3 (B)/NMB-3(B)This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:1.2.This device may not cause harmful interference, andThis device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits aredesigned to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in aparticular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user isencouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the manufacturer. Banner Engineering Corp. All rights reserved

Register Set 1 reads the following Modbus Registers with Metric System values as applicable: RegSet 1 Reg Adr 01 45202 Z-Axis RMS Velocity (mm/sec) Reg Adr 02 45204 Temperature ( C) Reg Adr 03 45206 X-Axis RMS Velocity (mm/sec) Reg Adr 04 45207 Z-Axis RMS Peak Acceleration (G)

Related Documents:

Modbus/TCP Modbus Master/Slave A Modbus master/slave network provides a protocol for data transfer and programming with a single RTU master and up to 247 slave . The Modbus/TCP KEPServer driver supports Modbus and Mailbox device models. Modbus Device Model. Publication 2711P-UM002B-EN-P - March 2007 Modbus Applications PanelView Plus

3. System description 5 3.1 Modbus 5 3.2 CIM 200 Modbus RTU 5 3.3 CIM 260 3G/4G cellular Modbus 5 3.4 CIM 500 Modbus TCP 5 4. Specifications 6 4.1 CIM module 6 4.2 CIM 200 Modbus RTU 6 4.3 CIM 260 3G/4G cellular 7 4.4 CIM 500 Modbus TCP 7 5. CIM 200 Modbus RTU setup 8 5.1 Setting the Modbus transmission speed 8 5.2 Setting the stop bits and the .

NP ModBus TCP N System Configuration Example 8 Add a ModBus Master Port and Node Expand the "MB NP Modbus TCP" branch on the I/O Configuration Form by clicking on the . Expand the Modbus TCP by clicking on the . Expand the "ModBus Port NP ModBus TCP Master Port" branch on the I/O Configuration Form by clicking on the . Expand the Nodes branch on the I/O Configuration Toolbox by .

Modbus TCP Ethernet EN . Version 0.14 . MODBUS TCP ETHERNET EN - V0.14 Modbus TCP Ethernet EN RapidoScan, Modbus TCP and Ethernet, EN.docx Preface . But because of the master - slave principle of Modbus a controlled polling by a master unit is necessary. Therefore, to transmit a measurement result via Modbus an additional query .

Advantech WebAccess Device Driver Guide Modicon Modbus TCP/IP Version 4.5 rev 0 Advantech Corp., Ltd. page 3 1. Modbus TCP/IP Device Communications 1.1 Introduction to Modbus Ethernet /TCPIP Advantech WebAccess SCADA Node provides a Modbus master interface using Modbus RTU protocol for communicating with Modbus slave devices. Slave

User Manual Modbus Slave / Modbus TCP Master Document code: MN67510_ENG Revision 1.012 Page 1 of 26 INDEX: Page UPDATED DOCUMENTATION 2 REVISION LIST 2 WARNING 2 TRADEMARKS 2 INDEX 3 WARRANTIES AND TECHNICAL SUPPORT 4 User Manual Revision 1.012 English Modbus Slave / Modbus TCP Master - Converter

This chapter lists the way to enable the Win-GRAF PAC as a Modbus Master to connect Modbus RTU/ASCII Slave or Modbus TCP/UDP Slave devices. If you want to use one XV board in the WP-5xx8-CE7, refer to Section 5.1.6 to Section 5.1.11. 5.1 Enabling the Win-GRAF PAC as a Modbus RTU/ASCII Master (I/O & XV-board) Application Diagram:

User Guide: FAAST XT Fire Alarm Aspiration Sensing Technology Modbus Protocol Schema 10 5 Rev A Modbus Resources 1. Modbus Application Protocol Specification, Version 1.1b3, Modbus Organization, Hopkinton, MA, 2012 2. Modbus over Serial Line Specification and Implementation Guide, Version 1.02, Modbus Organization, Hopkinton, MA, 2006