MODBUS Slave Communication Driver - Tatsoft

1y ago
10 Views
2 Downloads
953.53 KB
5 Pages
Last View : 5d ago
Last Download : 3m ago
Upload by : Jerry Bolanos
Transcription

Modbus Slave - Communication DriverRevision A -May 20, 2010MODBUS Slave Communication DriverThis document has the specific information related to the driver configuration. For a genericexplanation on Devices, Channels, Nodes and Points configuration, please refer to reference guide.ContentsSection 1 – Summary Information. 2Section 2 – Channel Configuration . 3Protocol Options. 3Settings . 3Section 3 – Node Configuration . 4Station Configuration. 4Section 4 – Point Configuration . 4Section 5 – Troubleshoot . 4Revision History. 5

MODBUS Slave Communication Driver – Revision APage: 2Section 1 – Summary InformationCommunication Driver Name: Modbus SlaveImplementation DLL: T.ProtocolDriver.ModbusSlave.dllProtocol: MODBUS RTU, ASCII and TCPInterface: TCP/IP and SerialDescription: Modbus Slave driver implements communication with master devices compatibles withModbus Open Standard protocol. It operates as a Slave on TCP/IP or serial networks.Devices supported: Any master Modbus device.Protocol Options: Message Format (ASCII, RTU or RTU TCP), SlaveIDMulti-threading: One thread with a pooling cycle for each master connected.Max number of nodes: One node for each Channel.PC Hardware requirements: Standard PC Ethernet interface board, RS485 or RS232 portSupported Operands:OperandRead Write Data Type Address size0 – Coils Bit1 bit1 – Input Status -Bit1 bit3 – Input Registers -Word2 bytes4 – Holding Registers Word2 bytesTable 1

MODBUS Slave Communication Driver – Revision APage: 3Section 2 – Channel ConfigurationProtocol OptionsSlaveID: Defines the driver slave address in the Modbus Network.Encoding:Determines how information will be packed into the message fields and decoded. Theoptions are:-RTU: Remote Terminal Unit mode, where each 8–bit byte in a message contains two 4–bithexadecimal characters-ASCII: The message is encoded in ASCII mode, where each 8–bit byte in a message is sent astwo ASCII characters-RTU TCP: The default transmission mode when the message is carried on a MODBUS TCP/IPnetwork. It contains information to allow the recipient to recognize message boundaries evenif the message has been split into multiple packetsSettingsSerial and MultiSerial channels:-Default configuration for ASCII mode :DataBits: 7StopBits:-1 if parity is used, 2 if no parityDefault configuration for RTU mode :DataBits:8StopBits: 1 if parity is used, 2 if no paritySet the other fields according to your Serial or MultiSerial port configurationTCP/IP channels:-Listening Port: Defines the Tcp port where the driver will be listening for the connections, thedefault Tcp port for the Modbus Network is 502. Note:You may need to configure your firewall to open the listening port

MODBUS Slave Communication Driver – Revision APage: 4Section 3 – Node ConfigurationStation ConfigurationThere is no station configuration for the Modbus Slave driverSection 4 – Point ConfigurationThe syntax for the Modbus communication points is: Operand Address Where: Operand indicates the memory area, the valid values are:0134for Coilsfor Input Statusfor Input Registersfor Holding RegistersFor more information about the valid operands, see the Table 1: Address indicates the data address in the memory area, from 1 to 65535Ex: 400001 (Operand Holding Register, Address 1)Section 5 – TroubleshootThe status of the driver execution can be observed through the diagnostic tools, which are: Trace window Property Watch Module InformationThe above tools indicate if the operations have succeeded or have failed where the status 0(zero) means success. Negative values are internal error codes and positive values are protocolerror codes.

MODBUS Slave Communication Driver – Revision APage: 5Modbus protocol error codes:ErrorNameDescription1ILLEGAL FUNCTIONThe function code received in the query is not allowable.2ILLEGAL DATA ADDRESSThe data address received in the query is not allowable.3ILLEGAL DATA VALUEA value contained in the query data field is not allowable.4SLAVE DEVICE FAILUREError while attempting to perform the requested action.5ACKNOWLEDGERequest accepted, but a long duration of time will berequired.6SLAVE DEVICE BUSYThe slave is engaged in a long–duration program command.7NEGATIVE ACKNOWLEDGECannot perform the program function received in thequery.8MEMORY PARITY ERRORParity error in the extended memory.Revision HistoryRevisionADescriptionInitial RevisionDateMay, 20th 2010

MODBUS Communication Slave Driver -Revision A Page: 2 Section 1 - Summary Information Communication Driver Name: Modbus Slave Implementation DLL: T.ProtocolDriver.ModbusSlave.dll Protocol: MODBUS RTU, ASCII and TCP Interface: TCP/IP and Serial Description: Modbus Slave driver implements communication with master devices compatibles with Modbus Open Standard protocol.

Related Documents:

Modbus/TCP Modbus Master/Slave A Modbus master/slave network provides a protocol for data transfer and programming with a single RTU master and up to 247 slave . The Modbus/TCP KEPServer driver supports Modbus and Mailbox device models. Modbus Device Model. Publication 2711P-UM002B-EN-P - March 2007 Modbus Applications PanelView Plus

Advantech WebAccess Device Driver Guide Modicon Modbus TCP/IP Version 4.5 rev 0 Advantech Corp., Ltd. page 3 1. Modbus TCP/IP Device Communications 1.1 Introduction to Modbus Ethernet /TCPIP Advantech WebAccess SCADA Node provides a Modbus master interface using Modbus RTU protocol for communicating with Modbus slave devices. Slave

3. System description 5 3.1 Modbus 5 3.2 CIM 200 Modbus RTU 5 3.3 CIM 260 3G/4G cellular Modbus 5 3.4 CIM 500 Modbus TCP 5 4. Specifications 6 4.1 CIM module 6 4.2 CIM 200 Modbus RTU 6 4.3 CIM 260 3G/4G cellular 7 4.4 CIM 500 Modbus TCP 7 5. CIM 200 Modbus RTU setup 8 5.1 Setting the Modbus transmission speed 8 5.2 Setting the stop bits and the .

User Manual Modbus Slave / Modbus TCP Master Document code: MN67510_ENG Revision 1.012 Page 1 of 26 INDEX: Page UPDATED DOCUMENTATION 2 REVISION LIST 2 WARNING 2 TRADEMARKS 2 INDEX 3 WARRANTIES AND TECHNICAL SUPPORT 4 User Manual Revision 1.012 English Modbus Slave / Modbus TCP Master - Converter

This chapter lists the way to enable the Win-GRAF PAC as a Modbus Master to connect Modbus RTU/ASCII Slave or Modbus TCP/UDP Slave devices. If you want to use one XV board in the WP-5xx8-CE7, refer to Section 5.1.6 to Section 5.1.11. 5.1 Enabling the Win-GRAF PAC as a Modbus RTU/ASCII Master (I/O & XV-board) Application Diagram:

Modbus(2) AirTF . Modbus(3) RH . Modbus(4) WS_mph . Modbus(5) WindDir . Modbus(6) SlrW . Modbus(7) Rain_in . NextScan . EndProg . Near the end of the program are several lines that copy values from measurements to values within an array. For example, this line copies the air temperature measurement into the second value of an array called .

Modbus TCP Ethernet EN . Version 0.14 . MODBUS TCP ETHERNET EN - V0.14 Modbus TCP Ethernet EN RapidoScan, Modbus TCP and Ethernet, EN.docx Preface . But because of the master - slave principle of Modbus a controlled polling by a master unit is necessary. Therefore, to transmit a measurement result via Modbus an additional query .

I. DNA, Chromosomes, Chromatin, and Genes DNA blueprint of life (has the instructions for making an organism) Chromatin uncoiled DNA Chromosome coiled DNA You have 46 chromosomes or 23 pairs in the nucleus of each body cell. o 23 from mom and 23 from dad Gene a segment of DNA that codes for a protein, which in turn codes for a trait (skin tone, eye color, etc); a gene is a stretch of .