ComprehensiveCatalogue2006Contactors andOverload relaysSuper Solution

The Challenges and Growth achieved by LGwill continue with New Will of LS Industrial Systems.

New Name of LG Industrial Systems,New Take-off for LS Industrial SystemsTo advance to the next level,LG Industrial Systems is reborn as LS Industrial Systems.LS Industrial Systems will continue to lead the futureof industrial electrics and automation by providingTotal Solution, a core essentialfor competition in the 21st century industrial era.

Research & DevelopmentWe provide differentiated values.The world-class Power Testing & Technology Institute guaranteescertified products and global brands.The PT&TI is an accredited testing laboratory that provides a worldwide testing service with a1500MVA-capacity High Power Laboratory, a High Voltage Laboratory, and a Reliability TestingLaboratory. Its testing has been fully acknowledged and recognized by overseas testing certificationbodies, such as KEMA of Netherlands, UL of USA, and CE of the EU for its low voltage testing.

Global technology and R&D are behind the best industrialElectric power and automation products from LSISQuality Test at PT&THigh Voltage Test / Impulse TestCharacteristics Test / VCB Characteristics TestElectro Technology R&D CenterThe Electro Technology R&D Center focuses onoverall research and development activities relatedto power supply systems such as low and highvoltage equipment as well as integrated digitalnetworks, automatic switchboards and integratedpower protection.The R&D Center maximizes energy efficiencies byintegrating rapidly developing information &technology, communication, electronics andmechanical engineering, while concentrating itsefforts in creating a safe and pleasant industrialenvironment. Power EquipmentsThe R&D Center researches products and technologies related tolow and high voltage circuit breakers and contactors as well aspower transmission & distribution. Electric TechnologyThe R&D Center analyzes and researches core technologies relatedto power equipment. SCADAThe R&D Center carries out projects and technology research in thefields of SCADA and DAS. SimulatorThe R&D Center predicts probable electrocution hazards byconducting simulated analyses of power generation phenomena,and develops simulation technologies and products that canoptimize the constituent facilities.Short-Circuit Test / ACB Short-circuit TestEnvironmental Test /Non-stop High Temperature TestPower Testing& Technology InstitutePT&T is a KOLAS-qualified (Korea LaboratoryAccreditation Scheme) accredited testing laboratoryand provides worldwide testing service with its1500MVA-capacity High Power Laboratory, HighVoltage Laboratory and Reliability TestingLaboratory.PT&T is also fully recognized by foreign testing andcertification bodies of high reputation as CESI of Italy,KEMA of Netherlands, UL of America, etc. for its lowvoltage testings. Available Tests- Electro-Mechanical Tests- Insulation Performance Tests- Short-Circuit Tests- Reliability Evaluation Tests- Arc Tests- Environmental Tests Research & DevelopmentTesting Technology, Measuring & Analyzing Technology, PowerEquipment Monitoring & Diagnostic Techniques, ReliabilityTesting & Evaluation Technology.

Quality & ServiceAdvanced Technologies &Up-to-date Production CapabilitiesTo accomplish its goal of becoming a global supplier,LS Industrial Systems has employed greater human resources andmaterials efficiently for rapid and flexible operational capacity.

Customer Satisfaction through Quality & ServiceThe best products come from LSISIn order to provide the best quality products and services, LSIS not only has obtained the ISO9001 certificate but alsoimplemented the TCS (Total Certification Service) program to help other affiliated companies to acquire the ISO9001 mark.We place the highest priority on delivering the best quality for complete customer satisfaction.Quality is the basis for customer satisfactionLSIS is implementing the 6-Sigma program with the goal of'zero-defect' to make only the highest quality products.BestQualityAnd to secure product reliability, we embody a high qualityguarantee system by carrying out product test evaluationsthat are internationally recognized for their useof the most current technology.A place for learning the most advanced technologiesThe LSIS’ training center is conducting customertechnology training for industrial system industry inKorea for the first time. The technical training center iscurrently giving lessons in the fields of factoryautomation, industrial electric power and electronicswith real practice equipment while providing hightech services through technical consulting andguidance.Training Center AuditoriumTechnical Training ClassesCustomer service is available anywhere in the worldLSIS offers web-based customer services anywherein the world. We provide technical information,prompt Q&A's and accurate history of maintenancethrough our web service. We have established theSupply Chain Management System that embodiesthe integrated management of acquisition,production and sales, and we are now leading ebusiness in the areas of industrial electric power andautomation.http://www.lsis.bizCall CenterProduct Exhibition Hall

Solution providerYou can count on us.New Face & New Resolution To becomea global leader that gives top priority to customer valuesWe promise you that LSIS will be reborn as a corporation that returns the best valuesto its customers.We are committed to global product development, driving future growth, and expandingthe overseas market share, as well as consolidating existing business.Join us in a future where LS Industrial Systems will become a genuine global leader.

Customer satisfaction with world-class products and services:LS Industrial Systems is committed to excellence!Electric Power IndustryElectric Equipment & SystemsThe electric equipment and systems of LS Industrial Systems, rangingfrom low to high voltage products, have not only acquired ISO 9001and 14001 certification for their efficient design and excellent quality,but many other certificates, including KEMA, TÜV, CESI, ASTA, andKERI. The outstanding quality of the products that we aremanufacturing conforms to international standards such as IEC, UL,ANSI, CCC, JIS, and KS.Cheongju Plant (Korea)Dalian Plant (China)Hanoi Plant (Vietnam)Wuxi Plant (China)We also provide Total Solutions that encompass customized designsand more advanced technology, as well as efficient production andinstallation, and highly accurate testing and analysis of powerequipment.Automation IndustryAutomation Equipment, Industrial IT & RFIDLS Industrial Systems, a leading pioneer of the domestic automationbusiness, developed the first ever PLC, Inverter (AC Drive), and DCS inKorean automation history. We now provide Total Solutions throughthe diverse application of our own products, ranging from controllersto control systems that are based on sophisticated technology andproven experience, to bring innovative change to distributionsystems and logistics.Chonan Plant (Korea)Wuxi Plant (China)Industrial Equipment IndustryMetal Processing & Electric Power ToolsIn addition to supplying basic industrial material, such as copper tubesand STS pipes to the electronics and chemical industries, LS IndustrialSystems also manufactures and supplies electric power tools that havebeen recognized for their excellent performance capabilities in over 38countries.Janghang Plant (Korea)Chonan Plant (Korea)

Super Solution ContactorsContactorsLSIS SUPER SOLUTION CONTACTOR

Specifications3-pole contactorsReversing contactorsControl circuit characteristicsAuxiliary contacts/contact blockscharacteristicsAccessoriesB-1-13B-2.Overload relaysSpecificationsCharacteristics class 10ACharacteristics class 20AccessoriesTOR Tripping characteristicsB-2-1B-2-3B-2-5B-2-7B-2-9B-3.Manual motorstartersSpecificationsSelection guideAccessoriesTechnical nsContactorsMotor starters (Screw type)Motor starters (Lug type)Reversing contactors and startersManual motor startersCombination Manual motor startersand contactorsOverload relays (Screw type)Overload relays (Lug type)Separate mounting units for overload relays(Screw type)Separate mounting units for overload relays(Lug type)Circuit -4-18B-4-19StandardsDefinitionsCertifications and approvalsUtilization categoriesAverage full-load currents of 3-phasesquirrel cage motorsMaking and breaking conditionsGeneral technical dataApplication guidanceType-2 erload relayAccessoriesMaunal Motor -5-45

Super solutionSuper PerformanceSuper Breaking capacitySuper Optimum coordinationSuper Extensive applications

Top-Class Contactor FamilyContactors & Overload RelaysLSIS contactor/overload relay meets IEC,UL, CSA, CCC and CE standards, it is theperfect product solution for applicationsall over the world. Including non-reversingand reversing contactors and starters aswell as overload relays and accessories,contactor/overload relay brings LSIS to awhole new level.The space saving and easy-to-install MCcontactors and starters is the efficientand effective solution for customerapplications from 9-95A. Enclosedcontrol options include metallic andnon-metallic enclosures.Only three frame sizes cover contactorratings up to 95A, making it easier forOEMs to lay out panels. With a broadline of application specific designs,contactor/overload relay allows customersto select the right tool for the job.

ContactorsLeading Solution Small size, big expectations World class with UL, CSA, CE and CCC approvals Easy to install Safe and simple to work Improved environmental performance Comprehensive range of accessories

LSIS Contactors“Provides total support in theof form dedicated”Limitless SatisfactionLS provides total support in the form of dedicated resources, highlydeveloped technologies, highly trained manpower and internationallyrecognised standards.The new range of motor control apparatus is supported by technicaldocumentation, drawing standards and design guides. This, withimproved marking and more compact size, makes it easier than everto integrate our products into your projects.Contactor ratingTypeAC3 9545kW95A140A

Compact design andthe most-effective solutions for the motorsContactorsCombination withManual Motor StartersThe perfect solution to reducing theinstallation time of panel controls. DIN rail mounting adapter Easy to combine by using adapter and wiring kit Space saving Removing contactor easily Finger-proof wiring linksMMS-100MMS-63CombinationsMMS-32Manual Motor StarterTypeSetting rangeContactorTypeMC-9MC-12MMS-320.1 32AMC-18MC-25MC-32MC-35MC-40MMS-636 63AMC-50MC-63MC-65MC-75MMS-10011 100AMC-85MC-95MC-63MC-32MC-95

LSIS ContactorsCombination with OverloadRelaysThe space-saving and easy-to-install contactorsand overload relays are the efficient and effectivesolution for customer applications up to 95A.MC -95CombinationsOverload RelayTypeSetting rangeContactorMC -63TypeMC-9MC-12MT-320.1 32AMC -32MC-18MC-25MC-32MC-35MC-40MT-634 65AMC-50MC-63MC-65MC-75MT-957 95AMC-85MC-95MT-32MT-63MT-95

LS Meta-MEC Manual Motor Starters providecompleted ranges up to 100Am45 mm55 m32AF

mm45m70 m63AF100AF

LS Meta-MEC Manual Motor Starters delivermore efficiency through various functions andcompact designFinger safe terminalsFront mounted auxiliarycontactDial coverEasy mounting onto DIN-railsLarge scale for current settingAuxiliaries are just snapped on:easy, fast, without toolsHandle Lock device (Off position)Dial cover lock deviceThree position operator handle:ON-OFF-TRIP(Only 100AF is applied)Test trip device for checks of thetrip mechanismIdentification labels45 mmHandle LockDial coverTerminalsMMS-32MMS-63MMS-100

Function֚ Protection of group installation֚ Protection of circuits֚ Motor protection֚ Starter protection֚ Wide range of ambienttemperature compensation֚ Phase failure protectionFeatureStandard֚ 45mm width up to 32A, 55mm width up֚to 63A and 70mm width rated to 100 amps֚ Three position operator:ON-OFF-TRIP (Only 100AF is applied)֚ Complete range of common accessoriesComply with the specifications in accordance withIEC 60947-2 & IEC 60947-4-1UL508 (Manual motor controller)UL508 (Combination motor controller type E starter)CSA C22.2 NO.14GB14048֚ Handle lock in the OFF position֚ Class 10 overload trip characteristicsCertification֚ Trip test֚KEMA CB type certificate֚ Finger safe terminal֚EC-Declaration of conformity֚ DIN rail & Screw mounting֚UL listed֚CSA certified֚CCC

ContactorsCombination withAccessories,Overload and MMS DIN rail mounting Easy to install Space saving Finger-proof design Safe and simple to work with Improved environmental performance U Contactor V Auxiliary contact unit W Interlock unit X Lug kit Y Screw kit Z Surge unit [ Wire kit \ Mounting unit ] Overload relay Remote reset unit Auxiliary contact unit c e- Head on (2P) ‘ Auxiliary contactunit- Head on (4P) a Safety cover b Manual Motor Starters c Front mountingauxiliary switch d Direct adaptor e Side mountingauxiliary switch f Side mountingalarm switch (Any trip) g Side mountingalarm switch (Magnetic trip) h Side mountingshunt releaseSide mountingundervoltage releaseSide mounting undervoltagerelease with switchMounting unit for MMS b f d g h

Flexibility &Convenience Z Y XU/2/T1V/4/T2W/6/T3 W U VU/1/T1V/2/T2W/2/T3 Y X [ ‘R a ] \95-NC-9697-NO-98

CONTACTORS IndexB-1. ContactorsSpecificationsB-1-13-pole contactorsB-1-3Reversing contactorsB-1-7Control circuit characteristicsB-1-9Auxiliary contacts/contact blocks characteristicsB-1-10AccessoriesAuxiliary contact blocksB-1-11Mechanical interlocksB-1-12Capacitor unitsB-1-13Surge suppressor unitsB-1-14Direct adaptersB-1-15EnvironmentB-1-16

ContactorsSpecifications32AFModelTypeConnection by screws clamp terminalsConnection by lugsMC-9MC-12MC-18MC-25MC-32 -----4050323Number of poles690VRated operational voltage, UeRated insulation voltage, UiConforming to IEC947-4-11000VConforming to UL, CSA600VRated impulse withstand voltage, Uimp8kVDegree of pollution (IEC60529)IP20Rated operational current Ie (θ 55 )AC-1Ue max 0V[kW]47.57.51518.5690V[kW]47.57.51518.5Rated operational power (θ 55 )AC-3200/240VAccording to IEC947-4-1Rated making capacity AC-3250Rated breaking capacity AC-3200Mechanical durability in millions of operating cyclesMaximum operating rate In operating cycles per hour151515151518001800180018001800Mechanical durability in millions of operating cycles8.078.078.078.078.07Maximum operating rate In operating cycles per hour72007200720072007200Electrical life for Ie/AC-3 Max in millions of operating cyclesMaximum operating rate in operating cycles per hour2.52.52.52.52.518001800180018001800AC control coil voltage operated contactorsWeightBasic dimensions (W H D)[kg][mm]0.4545 83 93DC control coil voltage operated contactorsWeightBasic dimensions (W H D)B-1-1[kg][mm]0.6345 83 118

-85MC-95 22120012001200120012001200120012000.941.8255 106 12270 140 1371.22.755 106 160.570 140 172.5B-1-2

Contactors3-pole contactorsfor motor control up to 45kW at 440V in category AC-3Control circuit voltage : AC or DCConnection by screw clamp terminalsRatedoperationalcurrent atAC-3AC-3 operational power ratings3-phase motors (θ 55 lt-inauxiliarycontactsTypeWeightConnection byscrew .518.518.5222240--MC-40 63S0.9418.5303030333365--MC-65 85S1.8225454545504595--MC-95S1.82MountingClip-on mounting on 35 mmrail or screw fixing.MC-65 to MC-95 types are mountable on 70mm DIN rail.Standard control circuit voltage, Coil voltage AC circuit 50/60Hz50Hz : 24, 32, 36, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 415, 440, 500, 550V60Hz : 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V50/60Hz : 24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 415, 440, 500, 550V DC circuit12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250VOverloads to suit contactors are on page B-2-2.B-1-3kg5.5AccessoriesAuxiliary contact blocks and modules: see pages B-1-13 to B-1-17.MC-95 SACcontrol

Contactors3-pole contactorsfor motor control up to 45kW at 440V in category AC-3Control circuit voltage : AC or DCConnection by lugsRatedoperationalcurrent atAC-3AC-3 operational power ratings3-phase motors (θ 55 Connection bylugsterminalsMC-35ACcontrolkgL0.94-MC-40 cessoriesAuxiliary contact blocks and modules: see pages B-1-13 to B-1-17.MountingClip-on mounting on 35 mmrail or screw fixing.MC-65 to MC-95 types are mountable on 70mm DIN rail.Standard control circuit voltage, Coil voltageMC-95L AC circuit 50/60Hz50Hz : 24, 32, 36, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 415, 440, 500, 550V60Hz : 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V50/60Hz : 24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 415, 440, 500, 550V DC circuit12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250VOverloads to suit contactors are on page B-2-2.B-1-4

Contactors3-pole contactorsfor control in utilization category AC-1, 25 to 140 AControl circuit voltage : AC or DCConnection by screw clamp eightConnection byscrew clampterminalsACcontrolAC-1 Non inductive loadsmaximum current (θ 55 )Numberof polesAC-1 403--MC-250.45503--MC-320.45553--MC-35 S0.94603--MC-40 S0.94703--MC-50 S0.94753--MC-63 S0.941003--MC-65S1.821103--MC-75S1.821353--MC-85 S1.821403--MC-951.82SAccessoriesAuxiliary contact blocks and modules: see pages B-1-13 to B-1-17.MountingClip-on mounting on 35 mmrail or screw fixing.MC-65 to MC-95 types are mountable on 70mm DIN rail.Standard control circuit voltage, Coil voltage AC circuit 50/60Hz50Hz : 24, 32, 36, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 415, 440, 500, 550V60Hz : 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V50/60Hz : 24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 415, 440, 500, 550V DC circuit12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250VOverloads to suit contactors are on page B-2-2.MC-95B-1-5Skg

Contactors3-pole contactorsfor control in utilization category AC-1, 25 to 140 AControl circuit voltage : AC or DCConnection by lugsMC-63LBuilt-inauxiliarycontactsAC-1 Non inductive loadsmaximum current (θ 55 )Numberof polesAC-1 (A)NONCNO553--TypeWeightConnection soriesAuxiliary contact blocks and modules: see pages B-1-13 to B-1-17.MountingClip-on mounting on 35 mmrail or screw fixing.MC-65 to MC-95 types are mountable on 70mm DIN rail.Standard control circuit voltage, Coil voltage AC circuit 50/60Hz50Hz : 24, 32, 36, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 415, 440, 500, 550V60Hz : 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V50/60Hz : 24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 415, 440, 500, 550VMC-95L DC circuit12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250VOverloads to suit contactors are on page B-2-2.B-1-6

ContactorsReversing contactorsfor motor control up to 45kW at 440V in category AC-3Control circuit voltage : AC or DCConnection by screw clamp terminalsRatedAC-3 operational power ratingsoperational3-phase motors (θ 55 )currentTypeBuilt-inauxiliaryACper contactorat AC-3200MC-32/RMC-63/R400VkWkWconnection 04595--MC-95/R3.25AccessoriesAuxiliary contact blocks and modules: see pages B-1-13 to B-1-17.MC-65 to MC-95 types are mountable on 70mm DIN rail.MountingClip-on mounting on 35 mmrail or screw fixing.Standard control circuit voltage, Coil voltage AC circuit 50/60Hz50Hz : 24, 32, 36, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 415, 440, 500, 550V60Hz : 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V50/60Hz : 24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 415, 440, 500, 550V DC circuit12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250VB-1-7kg2.5Note : Pre-wired power connections. Mechanical interlock without electrical interlocking. Please contact LSIS for reversing contactors with electrical interlocking pre-wired at the factory.MC-95/Rcontrolscrew clamp380240VWeight

ContactorsReversing contactorsfor motor control up to 45kW at 440V in category AC-3Control circuit voltage : AC or DCConnection by lugsRated200MC-63/RLBuilt-inTypeAC-3 operational power ratingsoperationalauxiliary3-phase motors (θ 55 )currentcontactsat AC-3per contactor400VkWkWACcontrolConnection NCkg7.515151518.518.535--MC-35/R L1.731118.518.518.5222240--MC-40/R L1.7315222222303050--MC-50/R L1.7315252525303063--MC-63/R L1.7318.5303030333365--MC-65/R L3.2522373737373775--MC-75/R L3.2525454545454585--MC-85/R L3.2525454545454595--MC-95/R L3.25Note : Pre-wired power connections. Mechanical interlock without electrical interlocking. Please contact LSIS for reversing contactors with electrical interlocking pre-wired at the factory.AccessoriesAuxiliary contact blocks and modules: see pages B-1-13 to B-1-17.MC-95/R LMountingClip-on mounting on 35 mmrail or screw fixing.MC-65 to MC-95 types are mountable on 70mm DIN rail.Standard control circuit voltage, Coil voltage AC circuit 50/60Hz50Hz : 24, 32, 36, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 415, 440, 500, 550V60Hz : 24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V50/60Hz : 24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 415, 440, 500, 550V DC circuit12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250VB-1-8

ContactorsControl circuit characteristicsTypeContactor 8MC-50MC-85MC-25MC-63MC-95MC-32AC control circuit characteristicsRated control circuit voltage [Uc]50Hz[V]24, 32, 36, 42, 48, 80, 100, 110, 220, 230, 240, 380, 400, 415, 440, 500, 550V60Hz[V]24, 48, 100, 110, 120, 200, 208, 220, 230, 240, 277, 380, 440, 480, 600V50/60Hz[V]24, 48, 100, 110, 120, 200, 220, 230, 240, 380, 415, 440, 500, 550VControl voltage limits0.8 . 1.1 Uc on 50 HzOperational0.85 . 1.1 Uc on 60 Hz0.3 . 0.6 UcDrop-outCoil consumption at 20 sing[ms]12 . 2212 . 2215 . 30Opening[ms]4 . 194 . 1915 . 30Heat dissipationOperating timeDC control circuit characteristicsRated control circuit voltage [Uc]12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250Control voltage limitsOperational0.7 . 1.25UcDrop-out0.1 . 0.3 UcCoil consumption at 20 2 . 2212 . 22100 . 120Opening[ms]4 . 194 . 1910 . 25Time constant (L/R)Operating timeB-1-9

ContactorsAuxiliary contacts/contact blocks characteristicsUA-1UA-1AU-1AU-4Contactor frameContactor typesNumber of auxiliary contactNormally open[EA]Normally closed[EA]Auxiliary contact blocks, optionalTypeNumber of auxiliary contactNormally open[EA]Normally closed[EA]CharacteristicsRated operational voltage, Ue [V]Rated insulation voltage, UiConforming to IEC 947-1 [V]Conforming to UL, CSA [V]Operating current frequency [Hz]Short-circuit protectionMinimum switching capacityU min.DC[V]I min.[mA]Thermal current, Ith[A]Operational currentAC15 duty120V[A](A600)240V[A]480V[A]600V[A]DC13 duty125V[A](P600)250V[A]440V[A]600V[A]Lifetime (mil.operations)AC15 duty220V440VDC13 duty220V440VOperation cycles per 122UA-113041160060060025 400gLgG fuse: 16A ( conforming to IEC 800B-1-10

ContactorsAccessoriesAuxiliary contact blocksfor contactors and reversing contactorsNumber ofUsing contactorsMountingper blockContactors andreversing contactorsSide mounting2NC112--222134-SideB-1-11NOMC-9R to 95RFront2WeightTypeMC-9 to 954Front 53

ContactorsAccessoriesMechanical/Electrical interlocksfor reversing contactorsfor motor controlTo be assembled by customerSet of power connectionsUsing contactorswith screw clamp C-50UR-0264MC-63MC-65MC-75MC-85Power connectionMC-95Note : Component parts for assembling by customer Mechanical interlock with 2NC contacts for electrical interlocking UR-02 provides both mechanical and electrical interlocksB-1-12

ContactorsAccessoriesCapacitor unitsDescription MC- (D), a contactor or special use, is adjusted for switching single-step ormultiple-step condenser bank. It is standardized by IEC-60947-4941, UL and CSA.Operation conditionOperating timesElectrical enduranceMC-9(D) 32(D)240 times/hMC-35(D) 95(D)100 times/hMC-9(D) 32(D)200,000 times/hMC-35(D) 95(D)100,000 times/h When the switch is closed condenser must be discharged before recharged.(Maximum residual voltage at terminals 50V) In working voltage 500V(Ue 500V), 100,000 times for MC-9(D) 32(D) and 80,000 times for MC35(D) 95(D). To prevent short current, gG type fuse must be 1.5 2 times than rated current. It must be separated from resistant wireRatingMaximum operating power at (kvar)TypeRated220 400 600 7629494AC-50Note) 1. Circumstance Temp. θ 55 2. The average temperature over a 24-hour period, in accordance with standards IEC 70 and 831 is 45 Mounting unitPhase-bus devices, Type MU, followed by MMS-32, 63 and 100These devices are attached module to connect joined Manual Motor Starter with Contactor.TypeMounting unitB-1-13ModelDescriptionApplied typeMU-45Width 45mmMMS-32S/H/HI MC-9 32 or GMC(D)-MMU-55Width 55mmMMS-63S/H/HI MC-35 63MU-70Width 70mmMMS-100S/H/HI MC-65 95

AccessoriesAccessoriesSurge suppressor unitsfor contactors and reversing contactorsUsing contactorsRatingVTypeInternal elementUS-1Varistor RCUS-2Varistor RCUS-22RCWeightgContactors and24 48Vreversing contactorsMC-9 to 95100 125VACDCAC/DCcommon200 240VUS-3Varistor RC380 440VUS-14Varistor24 48VUS-4Varistor RC100 125VUS-5Varistor RC200 220VUS-6Varistor RC24 48VUS-11Varistor100 125VUS-12Varistor200 240VUS-13Varistor20 Rated insulation voltage (Ui) : AC 1000V Rated impulse voltage (Uimp) : 8kV Degree of protection (IEC 60 529) : IP20B-1-14

ContactorsAccessoriesDirect adaptersfor connection element to combinea Manual Motor Starter(MMS) with a Contactor.MMS-32Using contactorsUsing manual motor startersTypeTypeSetting rangeWeightgMC-9 with AC coilMC-12 with AC coilMMS-32S0.1 32ADA-32SAMC-18 with AC coilMC-25 with AC coil27MMS-32H0.1 32ADA-32HAMMS-32S0.1 32ADA-32SDMMS-32H0.1 32ADA-32HDMMS-636 63ADA-63A56MMS-636 63ADA-63D69MMS-10011 100ADA-95A94MMS-10011 100ADA-95D118MC-32 with AC coilDirectadapterMC-9 with DC coilMC-12 with DC coilMC-18 with DC coilMC-25 with DC coil36MC-32 with DC coilMC-35 with AC coilMC-32MC-40 with AC coilMC-50 with AC coilMC-63 with AC coilMC-35 with DC coilMC-40 with DC coilMC-50 with DC coilMC-63 with DC coilMC-65 with AC coilMC-75 with AC coilMC-85 with AC coilMC-95 with AC coilMC-65 with DC coilMC-75 with DC coilMC-85 with DC coilMC-95 with DC coilB-1-15

ContactorsEnvironmentEnvironmentStandardsEN 60947-1, EN 60947-4-1Product certificationsCE, CSA, ULDegree of protection (IEC 60 529)Power terminals IP20Coil terminals IP20Ambient air temperatureStorage- 60. 80 CNormal operation- 25. 55 COperating altitudeMaximum 3000mOperating positions(without derating) 30 possible, in relation to normal vertical moun

Contactors & Overload Relays Top-Class Contactor Family LSIS contactor/overload relay meets IEC, UL, CSA, CCC and CE standards, it is the perfect product solution for applications all over the world. Including non-reversing and reversing contactors and starters as well as overload relays and accessories, contactor/overload relay brings LSIS to a

Related Documents:

A variety of installation methods Installation can be done using screws and on the DIN 35mm standard rail. Thermal overload relays that can be connected directly Thermal overload relays can be directly connected to magnetic contactors without a separate connector. Electrical lifetime (10 thousand) Mechanical lifetime (10 thousand) Contactors .

Electronic Overload Relays Electronic overload relays are another option for motor protection. The features and benefits of electronic overload relays vary but there are a few common traits. One advantage offered by electronic overload relays is a heaterless design. This reduces installation cost and the need to stock a variety of

AE contactor accessories and thermal O/L relays are the same as those of standard A contactors (see Main Catalogue 1SBC 0004 99 R1001 - Sections 4 and 5). Use type CA5-.E 4-pole auxiliary contact blocks for correct contact terminal marking. When contactors are mounted acc. to position 5 (see pages 5 and 6) do not use more than 2 add-on front

ABB 2/1 2 AX contactors and NX contactor relays AX 3-pole contactors Ordering details 3-pole contactors 2/3 Main accessories 2/10 Technical data 3-pole contactors 2/16 Terminal marking and positioning 2/27 Dimensions 2/28 NX contactor relays 2/33 Orderi

01 Magnetic Contactors and Starters Thermal Overload Relays, Solid-state Contactors . Time Delay Relays Manual Motor Starters and Contactors Combination Starters Pushbuttons, Selector Switches, Pilot Lights Rotary Switches, Cam Type Selector Switches Panel Switches, Terminal Blocks, Testing Terminals Molded Case Circuit Breakers Air Circuit .

Directional Relays 4 Differential and Timing Relays 5 Auxiliary Relays 6 Reclosing Relays 7 Synchronizing Relays 8 Generator and Motor Protection Relays 9 Voltage and Frequency Relays 10 Test Equipment and Accessories 11 General Information, Dimensions and Data12 . GE Multilin Subject:

3.5 Phase-to-phase faults 4. PROTECTIVE RELA VS 4.1 General 4.2 Differential relays 4.2.1 General 4.2.2 Differential relays for fully insulated transformers 4.2.3 Differential relays for auto-transformers 4.3 Overcurrent protection and impedance relays 4.3.1 Time-overcurrent relays 4.3.2 Under-impedance relays 4.3.3 Distance relays 4.4 Grou d .

ISO 14001:2015 – Why was the standard revised? Technically sound basis - should be based on proven management practices or existing scientifically validated and relevant data. Easily understood - should be easily understood, unambiguous, free from cultural bias, easily translatable, and applicable to businesses in general. Free trade - should permit the free trade of goods and .