PanelView eTransfer Utility(Cat. No. 2711E-ND7)User Manual

Important User InformationBecause of the variety of uses for the products described in thispublication, those responsible for the application and use of thiscontrol equipment must satisfy themselves that all necessary stepshave been taken to assure that each application and use meets allperformance and safety requirements, including any applicable laws,regulations, codes and standards.The illustrations, charts, sample programs and layout examples shownin this guide are intended solely for purposes of example. Since thereare many variables and requirements associated with any particularinstallation, Allen-Bradley does not assume responsibility or liability(to include intellectual property liability) for actual use based uponthe examples shown in this publication.Allen-Bradley publication SGI-1.1, Safety Guidelines for theApplication, Installation and Maintenance of Solid-State Control(available from your local Allen-Bradley office), describes someimportant differences between solid-state equipment andelectromechanical devices that should be taken into considerationwhen applying products such as those described in this publication.Reproduction of the contents of this copyrighted publication, in wholeor part, without written permission of Rockwell Automation, isprohibited.Throughout this manual we use notes to make you aware of safetyconsiderations:ATTENTION Identifies information about practices orcircumstances that can lead to personal injury ordeath, property damage or economic lossAttention statements help you to: identify a hazard avoid a hazard recognize the consequencesIMPORTANTIdentifies information that is critical for successfulapplication and understanding of the product.PanelBuilder, PanelView, Data Highway Plus, DH , SLC, SLC 500, RSLinx, WINtelligent LINX and INTERCHANGE are trademarks,and PLC, PLC-2, and PLC-3 are registered trademarks of Rockwell Automation.IBM, PC, AT, XT, PS/2, and PC DOS are registered trademarks of International Business Corporation.Microsoft Windows, Windows NT, and Windows 2000 are trademarks, and Microsoft, MS, and MS-DOS are registered trademarksof Microsoft Corporation.Ethernet is a registered trademark of Digital Equipment Corporation, Intel, and Xerox Corporation.All other brand and product names are trademarks or registered trademarks of their respective companies and are hereebyacknowledged.

PrefaceBefore You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Purpose of This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Contents of This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Technical Support Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Allen-Bradley Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Local Product Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Conventions Used in This Manual . . . . . . . . . . . . . . . . . . . . . . . . .Introducing the PanelView eTransfer Utility 32Working with the PanelView eTransfer Utility 32P–1P–1P–2P–2P–4P–4P–4P–4Chapter 1About the PanelView e File Transfer Utility 32 . . . . . . . . . . . . . . . .Types of Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Types of Transfers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Methods of Downloading and Uploading Applications andAlarm History Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .File Transfer Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .For PanelView 1000e, 1200e, or 1400e Terminals Transfers . . . .PanelView e Transfer Utility 32 and RSLinx . . . . . . . . . . . . . . . .1–11–31–31–31–41–41–51–6Chapter 2System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PanelBuilder Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PanelView Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Equipment Required for Transferring Applications . . . . . . . . . . . . .Serial Upload/Download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DH Network Transfers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ControlNet Network Transfers . . . . . . . . . . . . . . . . . . . . . . . . . .Remote I/O Pass-Through Transfers . . . . . . . . . . . . . . . . . . . . .General Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . .Installing FTU32 from CD-ROM on Windows NT or Windows 95 . . .Installing the FTU from CD-ROM on Windows 95 or Windows 3.x . .Installing the FTU32 from Floppy Disks on Windows NTor Windows 95 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Installing the FTU from Floppy Disks on Windows 95or Windows 3.x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Starting the PanelView e Transfer Utility 32 Version 5 (FTU32) . . . .Exiting the PanelView e Transfer Utility 32 . . . . . . . . . . . . . . . . . . ��172–212–232–242–262–28Publication 2711E-6.16

toc–iiTable of ContentsUploading1000e/1200e/1400eApplication Files and AlarmHistory FilesChapter 3Downloading1000e/1200e/1400eApplication FilesChapter 4ConfiguringCommunications Settingsfor 1000e/1200e/1400eApplication TransfersChapter 5Uploading PanelView 1000e/1200e/1400e Application Files . . . . . .Uploading the PanelView 1000e/1200e/1400e Alarm History File . . .Alarm History Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Uploading the Alarm History Files . . . . . . . . . . . . . . . . . . . . . . .Downloading PanelView 1000e/1200e/1400e Application Files . . . .Selecting Communication Hardware and Driver Packages . . . . . . .Configuring Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . .Selecting the Transfer Method . . . . . . . . . . . . . . . . . . . . . . . . . . .Configuring the Transfer Parameters . . . . . . . . . . . . . . . . . . . . . . .Obtain Transfer Parameters from an Application File . . . . . . . . . .Configure Transfer Parameters Manually . . . . . . . . . . . . . . . . . .Serial Transfer Method — Driver Configuration . . . . . . . . . . . .Network Transfer Method — Network andDriver Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . .Remote I/O Pass-Through — Network, Driver, andPass-Through Setup Configuration . . . . . . . . . . . . . . . . . .Saving the Communication Settings . . . . . . . . . . . . . . . . . . . . . . .Troubleshooting for thePanelView e TransferUtility 32Chapter 6Constructing the TransferPathAppendix AGeneral Upload/Download Problems . . . . . . . . . . . . . . . . . . . . . . .Communication Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .*.pvd File Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Compatibility Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Driver Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ControlNet Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DH Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DH Networks Bridged by a 1785-KA . . . . . . . . . . . . . . . . . . . . . .Multiple DH Networks Connected by a Pyramid Integrator (PI) . . . .IndexPublication –46–56–9A–1A–1A–2A–4

PrefacePrefaceWelcome to the Allen-Bradley PanelView e Transfer Utility 32. Withthis software, you can transfer PanelBuilder applications to and froman IBM-compatible personal computer and PanelView 1000e, and1400e operator terminals. This utility is referred to as FTU 32 in thismanual and supports RSLinx drivers.There are references to FTU ver 3 in this manual which is a 16 bitPV “e”, upload/download program designed to be used on computerswith Windows 3.1 or Windows 95 operating systems along withInterchange or WinLinx drivers. FTU ver 3 is included on the CDwith both PanelBuilder 1400e (2711E–ND1) and the separateupload/download utility package, 2711E–ND7.In addition, the PV 1200, DOS upload/download utility is alsoincluded with catalog number 2711E–ND7 to support the original12” CRT based PanelView 1200. This can be installed on the samecomputer and accessed from FTU ver 3 above. See publication2711–UM010B–EN–P, PanelBuilder 1200 Transfer Utility manualfor additional information."Note: In all cases, the associated PanelBuilder software must beused to save the file in downloadable format (*.pvd for PV ”e” and*cfg for PV 1200) before the download utility is used.Before You BeginBefore you begin you should be familiar with: Microsoft Windows 2000, Microsoft Windows NTt 4.0,Microsoft Windows 95 or Microsoft Windows 3.x operatingsystemPurpose of This ManualThe PanelView e Transfer Utility User Manual describes themethods of transferring application and alarm history files betweenthe computer and the PanelView terminal. The computer must havethe PanelView e Transfer Utility installed. This user manual alsoprovides step-by-step instructions for each method.

P–2PrefaceContents of This ManualChapterTitleContentsPrefaceAn overview of this manual and a list of relatedpublications.1Introducing thePanelView e TransferUtility 32Introduces the PanelView e Transfer Utility 32and the methods of transferring PanelBuilderapplications.2Working with thePanelView e TransferUtility 32Step-by-step instructions for installing thePanelView e Transfer Utility 32 and starting itfor the first time. Also includes instructions forexiting from the utility.3Uploading1000e/1200e/1400eApplication Files andAlarm History FilesExplains how to upload application files andalarm history files using serial transfer, networktransfer for DH and ControlNet, andRemote I/O Pass-Through transfers.4Downloading1000e/1200e/1400eApplication FilesExplains how to download application filesusing the various transfer methods.5ConfiguringCommunicationsSettings for1000e/1200e/1400eApplication TransfersExplains how to set the commoncommunication parameters for uploading anddownloading files.6Troubleshooting for thePanelView e TransferUtility 32Explains how to diagnose and solve problemsyou might encounter when using thePanelView e Transfer Utility 32.Related PublicationsThe following publications contain additional information about thePanelBuilder application as well as about PanelView terminalsoperation. Contact your local Allen-Bradley office or distributor forcopies of any of these publications.ForSeePublication NumberComprehensive instructions for working with thePanelBuilder 1400e Configuration Softwareapplication.PanelBuilder 1400e Configuration Software for Windows UserManual2711E-6.14In-depth information about the objects that youcan create for application screens.PanelBuilder 1400e Configuration Software for WindowsReference Manual2711E-6.15Information about installing, configuring,maintaining, and troubleshooting PanelView1000e, 1200e, and 1400e operator terminals.Also includes specifications for the terminals.PanelView 1000e, 1200e, and 1400e Operator TerminalsUser Manual2711E-6.17

PrefaceP–3ForSeePublication NumberA complete list of current Allen-Bradleydocumentation, including ordering instructions.Also indicates whether the documents areavailable on CD-ROM or in multiple languages.Allen-Bradley Publication IndexSD499A glossary of industrial automation terms andabbreviations.Allen-Bradley Industrial Automation GlossaryAG-7.1

P–4PrefaceTechnical SupportServicesIf you have questions about the PanelView e Transfer Utility 32,consult the online help and user documentation first. If you can’t findthe answer, take advantage of our Technical Support Fax Backsystem, available 24 hours a day, 7 days a week at 1-440-646-6701.Or, browse our technical document library on the World Wide Webat tively, contact:Allen-BradleyTechnical Support1 Allen Bradley DriveMayfield Heights, Ohio 44124-6118or call 1-440-646-5800 or fax 1-440-646-5801 for technical supportbetween 8 AM and 5 PM (EST), Monday to Friday.Allen-Bradley SupportAllen-Bradley provides support services worldwide, with over 75Sales/Support Offices, 512 authorized Distributors, and 260authorized Systems Integrators located throughout the United Statesalone, plus Allen-Bradley representatives in every major country inthe world.Local Product SupportContact your local Allen-Bradley representative for: sales and order support product technical training warranty support support service agreementsConventions Used in ThisManual"The following conventions are used throughout this manual: bulleted lists such as this one provide information, notprocedural steps numbered lists provide sequential steps or hierarchicalinformation italic type is used for emphasis text in this font indicates words or phrases you should typeWe also use this arrow to call attention to helpful information.

Chapter1Introducing the PanelView eTransfer Utility 32This chapter introduces you to the PanelView e Transfer Utility 32,version 5, including: what the Transfer Utility is used for the methods of transferring application files tips for transferring filesAbout the PanelView e FileTransfer Utility 32Use the PanelView e Transfer Utility 32 to transfer PanelBuilderapplication files between a computer and the PanelView terminal.You can transfer application files created in PanelBuilder 1400e forWindows. You can also use this utility to upload alarm historyinformation from a PanelView 1000e/1200e/1400e terminal to thecomputer that the Transfer Utility runs on. Only Version 2 and lateralarm history files can be uploaded.To start the PanelView e Transfer Utility 32, double-click thefollowing icon in Windows NT or Windows 95.After you start the application, the following splash screen isdisplayed momentarily.

1–2Introducing the PanelView e Transfer Utility 32When the splash screen disappears, the following maindownload/upload dialog box is displayed.The PanelView e Transfer Utility 32 can also be accessed from thePanelBuilder 1400e software. In the main PanelBuilder 1400e dialogbox, choose Download or Upload from the File menu. The TransferUtility’s main download/upload dialog box is displayedautomatically."Note: PanelBuilder software does not need to be installed in order todo file transfers. You need only PanelView e Transfer Utility 32 anda PanelView application file saved in a .pvd format.

Introducing the PanelView e Transfer Utility 321–3Types of ApplicationsYou can transfer terminal application files, whose names end in .pvd,using the PanelView e Transfer Utility 32. The *.pvd files are createdin PanelBuilder 1400e for Windows. Files are initially created andedited as *.pvc. You then must save the file as a *.pvd to downloadit. These are PanelView enhanced 1200 (Series F and later) and1000e/1200e/1400e terminal files.Types of TransfersThe PanelView e Transfer Utility 32 does the following types oftransfers: downloading an application file—Transferring an applicationfile from the development computer to a PanelView terminal sothe application can be run. PanelView enhanced 1200 (Series Fand later) and PanelView 1000e/1200e/1400e applications can bedownloaded. uploading an application file—Transferring an application filefrom the PanelView terminal to the development computer thatthe PanelView e Transfer Utility 32 is on so the application canbe edited or archived. PanelView enhanced 1200 (Series F andlater) and PanelView 1000e/1200e/1400e applications can beuploaded. uploading alarm history files—Transferring the Alarm HistoryFile from the PanelView terminal to the development computer sothe files can be analyzed or archived. Only PanelView enhanced1200 (Series F and later) and 1000e/1200e/1400e V02.00.00 andlater Alarm History files can be uploaded.Methods of Downloadingand UploadingApplications and AlarmHistory FilesThere are three methods for downloading and uploading applicationsand alarm history files: Serial (RS-232) Upload/Download—To transfer applications serially,you need an RS-232 Serial (Upload/Download) cable (A-B Cat. no.2706-NC13, 2711-NC13, or 2711-NC14 for PanelView 1000e/1400eSeries F and later terminals; 2711-NC1 for PanelView 1200e/1400eterminals Series E and earlier),for connecting the computer to the terminal.Alarm History files directly by connecting the serial ports on thecomputer and PanelView terminal. This is a serial file transfer. Network Upload/Download—You can upload applications orAlarm History files once you have connected the PanelViewterminal and computer to the DH or ControlNet network. Youcan download applications between the computer running theTransfer Utility and the PanelView terminal over the DH orControlNet network without taking the terminal out of Run mode.Since the serial port is not used for network transfers, you canprint from the PanelView terminal without changing the serialcabling of the terminal.

1–4Introducing the PanelView e Transfer Utility 32To do network downloads, you can use RSLinx drivers. RSLinx Liteis included on floppy disks with your PanelBuilder 1400esoftware package (A-B Catalog Number 2711E-ND1) or TransferUtility software package (A-B Catalog Number 2711E-ND7); youmust install RSLinx separately. For RSLinx installationprocedures, see the RSLinx user documentation provided. For acomplete list of hardware and driver requirements, refer to thetable in Chapter 5."Note: For information about the ControlNet CommunicationInterface Card requirements for uploading and downloading overControlNet, refer to the PanelView 1000e, 1200e, and 1400eOperator Terminals User Manual (Publication Number2711E-6.17). Remote I/O Pass-Through—Using Remote I/O Pass-Through,you can upload application files and Alarm History files overRemote I/O and then over DH , ControlNet, or Ethernet.You can download a Remote I/O application between thePanelView terminal and computer without taking the terminal outof Run mode or changing the terminal’s serial cabling.Since the serial port is not used for Remote I/O Pass-Throughtransfers, you can print from the PanelView terminal withoutchanging the serial cabling of the terminal.To do Remote I/O Pass-Through downloads, you can use RSLinxdrivers. RSLinx is included with your Transfer Utility softwarepackage; however, you must install RSLinx separately. Refer tothe table in Chapter 5 for a complete list of hardware and driverrequirements.File Transfer TipsRead this section when preparing to perform an application filetransfer.General For application file transfers over ControlNet or DH , be sure thePanelView terminal address is correct, or for file transfers overRemote I/O Pass-Through, be sure the terminal address andcontrol byte are correct; otherwise, the transfer could corrupt dataused by another device on the network, such as the PLC. For application file transfers (serial or network), thecommunication parameters of the PanelView e Transfer Utility 32driver must match those being used by the PanelView terminal. Do not interrupt a download by cycling power during theoperation.

Introducing the PanelView e Transfer Utility 321–5 Do not try to download application files from two developmentcomputers to the same location at the same time. Results areunpredictable. During the download, the PanelView terminal ignores all operatorinputs and PLC outputs. The current application screen isremoved and the Transfer screen and progress bar are displayed. The rack assignments (for Remote I/O applications) or terminalnetwork address (for DH and ControlNet) remain as they wereset for the previous current application until the download iscomplete.For PanelView 1000e, 1200e, or 1400e Terminals Transfers Before you download to PanelView 1000e, 1200e, or 1400eterminals, check the size of the application file (the .pvd file) toensure it will fit in the terminal’s memory or on the PCMCIAmemory card. For more information, refer to Chapter 3, Workingwith Applications in the PanelBuilder 1400e ConfigurationSoftware for Windows User Manual (Publication Number2711E-819). When you upload an application from the PanelView 1000e,1200e, or 1400e terminals using the PanelView e TransferUtility 32, the initial tag values of the application are uploaded,not the application’s current values. When you upload an application from the PanelView 1000e,1200e, or 1400e terminals to edit it in PanelBuilder, many of thefollowing items that were originally in the downloadedapplication are not uploaded: unused nodes unused scan classes unused tags unused tag folders unused graphic images tag descriptions variable names comments in expressions unused scheduled files When the PanelView e Transfer Utility 32 uploads an applicationfile, it creates a *.pvd file. PanelBuilder can open the *.pvd file tocreate a *.pvc file. When *.pvd files are opened in PanelBuilder,the *.pvd files are always regenerated as *.pvc files with a privatetag database.

1–6Introducing the PanelView e Transfer Utility 32PanelView e Transfer Utility 32 and RSLinxThe Transfer Utility supports RSLinx network drivers. RSLinx Lite,Version 2.0 or later, is included with your PanelBuilder 1400esoftware package (A-B Catalog Number 2711E-ND1) or TransferUtility software package (A-B Catalog Number 2711E-ND7). ThePanelView e Transfer Utility 32 supports a subset of the RSLinxdrivers which are used by DH or ControlNet. You can use thesedrivers to transfer files over DH , ControlNet, Remote I/OPass-Through, or serial connection networks. For more information,refer to the RSLinx user documentation.If you use RSLinx drivers, install them before setting upcommunications for application file transfers. The PanelView eTransfer Utility 32 displays the RSLinx drivers as driver options, butyou can use them only if they are installed. Make sure the driver youselect is configured correctly for the communication device andsettings. You can open the RSLinx configuration utility from theTransfer Utility to configure the selected driver.FTU Version 3PanelView 1200/1400e Transfer Utility and INTERCHANGEThe PanelView 1200/1400e Transfer Utility Version 3 supports the full rangeof INTERCHANGE serial and network drivers. TheINTERCHANGE drivers allow ports and communication devices tobe shared between PanelBuilder and other Allen-Bradley productssuch as the 6200-series PLC-5 Programming Software andPanelBuilder 900. INTERCHANGE drivers also supportcommunication cards such as the KT and PCMK for DH communication. Contact your Allen-Bradley representative for moreinformation on INTERCHANGE.To use the INTERCHANGE drivers, install INTERCHANGE beforesetting up file transfer communications. The transfer utility displaysthe INTERCHANGE drivers as driver options, but you can use themonly if INTERCHANGE is installed. The driver optionsINTERCHANGE Port 1 to INTERCHANGE Port 8 map to the eightports supported by INTERCHANGE.If you have INTERCHANGE Version 6.1.0 or later, you can selectone of these options and call up the INTERCHANGE DeviceConfiguration Utility from the PanelView 1200/1400e TransferUtility. From the configuration utility you can view and change theconfiguration of any of the eight INTERCHANGE ports. Make surethe port you select for your driver is configured correctly for thecommunication device and settings. Refer to the INTERCHANGEDevice Configuration Utility user documentation for information onusing the utility.

Introducing the PanelView e Transfer Utility 321–7If your version of INTERCHANGE is earlier than 6.1.0, you mustview and configure the ports outside of the PanelView 1200/1400eTransfer Utility. Refer to your INTERCHANGE user documentation.Again, make sure the port you select is configured correctly for yourcommunication device and settings.FTU Version 3PanelView 1200/1400e Transfer Utility and WINtelligent LINXThe PanelView 1200/1400e Transfer Utility Version 3 supportsWINtelligent LINX network drivers, Version 5.20.00 or later. ThePanelView 1200/1400e Transfer Utility supports a subset of theWINtelligent LINX drivers—those used for appropriate DH ,ControlNet, and serial transfers. You can use these drivers to transferfiles over DH , ControlNet, RIO Pass-Through, or serial connectionnetworks. Contact your Allen-Bradley Sales Representative for moreinformation on WINtelligent LINX.To use the WINtelligent LINX drivers, install them before setting uptransfer communications. The PanelView 1200/1400e TransferUtility displays the WINtelligent LINX drivers as driver options, butyou can use them only if they are installed. Make sure the driver youselect is configured correctly for the communication device andsettings. You can open the WINtelligent LINX configuration utilityfrom the Transfer Utility to configure your selected driver.Refer to the WINtelligent LINX for Allen-Bradley ProgrammableControllers User’s Guide (Publication Number 9352-WABUG) forcomplete information.Important:The PanelView 1200/1400e Transfer Utility works withINTERCHANGE only, WINtelligent LINX only, orwith both INTERCHANGE and WINtelligent LINXinstalled on the same computer.

Chapter2Working with the PanelView eTransfer Utility 32This chapter provides instructions for setting up and using thePanelView e Transfer Utility 32, including: minimum hardware and software requirements installing and starting the PanelView e Transfer Utility 32 exiting from the PanelView e Transfer Utility 32The PanelView e Transfer Utility 32 has context-sensitive onlinehelp that you can access at any time, by pressing the Help button, F1on your keyboard, or by clicking the Help menu item. You can alsoin the utility’s toolbar. Auto-Help automaticallyclick the icondisplays help information as you work with the utility from oneapplication window to another.For version information and information about obtaining technicalsupport, click the iconin the utility’s toolbar.System RequirementsYou need the following hardware and software to install thePanelView e Transfer Utility 32.Table 2.A Hardware and Software RequirementsSystem RequirementsHardwareA personal computer with a 66-MHz, 486-DX or highermicroprocessor, with a recommended minimum of 16-MB RAM (forWindows 95 operating system) or 32-MB RAM(for Windows 2000(SP2)/NT operating system)CD-ROM drive (recommended)A hard disk with 10 MB of free space and 15 MB for RSLinx LiteAn 8-MB swap fileA 3.5-inch high-density (1.44-MB) disk driveAn RS-232 serial port for uploading or downloading applications, orother communication cards listed later in this chapterA standard VGA (640 by 480) display adapter configured for at least16 colorsA mouse or pointing device supported by WindowsSoftwareMicrosoft Windows 2000(SP2), Windows NT Version 4.0, orWindows 95Publication 2711E-UM003B–EN–P

2–2Working with the PanelView e Transfer Utility 32PanelBuilder ApplicationsFor details about PanelBuilder applications, see Types ofApplications in Chapter 1 of this manual.PanelView TerminalsTo transfer files using the PanelView e Transfer Utility 32, you musthave one or more of the following PanelView terminals. Table 2.Blists the terminal products and their catalog numbers.Table 2.B PanelView Terminal Products and CatalogNumbersCatalog NumberProductDescription2711E-T10C61000e Touch Screen TerminalColor display, clip mount, NEMA 4X2711E-K10C61000e Keypad TerminalColor display, clip mount, NEMA 4X2711E-T10C151000e Touch Screen TerminalControlNet 1.5 enhanced 2711E-T10C6terminal2711E-K10C151000e Keypad TerminalControlNet 1.5 enhanced 2711E-K10C6terminal2711E-T14C61400e Touch Screen TerminalColor display, stud mount, NEMA 4X (indooruse only)2711E-K14C61400e Keypad TerminalColor display, stud mount, NEMA 4X (indooruse only)2711E-T14C151400e Touch Screen TerminalControlNet 1.5 enhanced 2711E-T14C6terminal2711E-K14C151400e Keypad TerminalControlNet 1.5 enhanced 2711E-K14C6terminal2711-NC1Upload/Download CableFor 1200e/1400e Series E and earlierterminals. Includes a 9-pin to 25-pin RS-232serial cable (Upload/Download cable) totransfer files between terminal anddevelopment computer. The cable is 10 ft(3.1 m) long.2711-NC13Upload/Download CableFor 1000e/1400e Series F and laterterminals. Includes a 9-pin RS-232 serialcable (Upload/Download cable) to transferfiles between terminal and developmentcomputer. The cable is 16.4 ft (5 m) long.2711-NC14Upload/Download CableFor 1000e/1400e Series F and laterterminals. Includes a 9-pin RS-232 serialcable (Upload/Download cable) to transferfiles between terminal and developmentcomputer. The cable is 32.7 ft (10 m) long.2706-NC13Upload/Download CableFor 1000e/1400e Series F and laterterminals. Includes a 9-pin RS-232 serialcable (Upload/Download cable) to transferfiles between terminal and developmentcomputer. The cable is 10 ft (3 m) long.Publication 2711E-UM003B–EN–P

Working with the PanelView e Transfer Utility 32Equipment Required forTransferring Applications2–3This section describes the equipment required to perform thefollowing application transfers: serial transfer DH network transfer ControlNet network transfer Remote I/O Pass-Through transferSerial Upload/DownloadTo transfer applications serially, you need an RS-232 Serial(Upload/Download) cable (A-B Catalog Numbers 2706-NC13,2711-NC13, 2711-NC14 for PanelView 1000e/1400e Series F andlater terminals; 2711-NC1 for PanelView 1200e/1400e terminalsSeries E and earlier) for connecting the computer to the PanelViewterminal.The Transfer Utility can transfer applications serially without usingthe RSLinx drivers.Figure 2.1 Connecting the Upl

the methods of transferring application files tips for transferring files Use the PanelView e Transfer Utility 32 to transfer PanelBuilder application files between a computer and the PanelView terminal. You can transfer application files created in PanelBuilder 1400e for Windows. You can also use this utility to upload alarm history

Related Documents:

PanelView 5310 Terminals 17 PanelView 5510 Terminals 19 ArmorView Plus 7 Terminals 21 PanelView Plus 7 - Performance Terminals 23 PanelView Plus 7 - Standard Terminals 27 PanelView Plus 6 - 700, 1000, 1250, and 1500 Terminals 29 PanelView Plus 6 - 400 and 600 Terminals 33 PanelView Plus 6 - Compact Terminals 35

For PanelView Plus 7 Performance, refer to the PanelView Plus 7 Performance Terminals User Manual, Rockwell Automation Publication 2711P-UM008. For PanelView 5500 terminals, refer to the PanelView 5500 Terminals User Manual, Rockwell Automation Publication 2715-UM001. – T

PanelView Plus 7 – Standard Terminals 25 PanelView Plus 6 – 700, 1000, 1250, and 1500 Terminals 27 PanelView Plus 6 – 400 and 600 Terminals 31 PanelView Plus 6 – Compact Terminals 33 MobileView Tethered Operator Terminals 35 PanelView 800 Terminals 37 PanelView

FactoryTalk View ME and PanelView Plus 6/7 in a Control System PanelView Plus 6/7 is an electronic operator device. FactoryTalk View ME runs the user-designed application with which operators interact. PanelView Plus 6/7 PanelView Plus 6 and PanelView Plus 7 terminals run Microsoft W

PLC program running the top drive Ordering the new PanelView Unit 2. Order the required new PanelView Plus 6 1250 unit listed below. Table 1: PanelView Plus 6 1250 Qty Part Number Description 1 AY18938 PanelView Plus 6 1250. Model: AC Top Drives Serial #: N/A Mar. 28, 2014

Apr 28, 2020 · Subject: PanelView Plus 6 Lifecycle Status Announcement Update As of February 18, 2020, Rockwell Automation is delaying the discontinuation date for 7”, 10”, 12” and 15” PanelView Plus 6 terminals by one year. The new discontinue date for these

PanelView Plus 6 Specifications PanelView Plus 6 - 700 1500 Terminals The PanelView Plus 6 - 700 1500 terminals use modular components that allow for flexible configuration, installation, and upgrades. Factory-assembled

API RP 581 is a well-established methodology for conducting RBI in the downstream industry and the 3rd edition of the standard has just been published in April 2016. This paper examines the new features of the 3rd edition particularly for internal and external thinning and corrosion under insulation and it also discusses a case study of application of this latest RBI methodology in France .