Wet Type Magnetic Solenoid Valve SS And SA Series G01-31 Design

1y ago
13 Views
2 Downloads
1.17 MB
12 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Macey Ridenour
Transcription

GLOBAL SERIES Wet Type Magnetic Solenoid Valve SS and SA Series G01-31 Design Recognized by Overseas Safety Standards

In Pursuit of Safety (conforms to overseas standards) and Easy Use Conformance to Global Standards CE-, UL- and CSA-recognized You can depend on solenoid valves of NACHI brand. Recognized by reliable overseas safety standards such as CE (Europe), UL (U.S.A.) and CSA (Canada). Interchangeable with Conventional Products (30 designs) The valve proper as well as such parts as a centralized terminal box and coil are interchangeable with the conventional ones in terms of a kit. Features 1. Easy use 2. Low power consumption An expanded wiring space ensures easy wiring. Use of a 4-pin M12-connector (IEC60947-5-2) permits one-touch connection of wires. (Compatible with special parts) Redesigned terminal box improves waterproof properties. The power consumption of the DC solenoid (D※ and E※) is reduced, with high voltage and heavy current kept unchanged. This will further promote your energy saving policy. 3. Reliable switching An innovative fluid reaction compensating mechanism assures reliable valve switching. (Patent pending) Pursuit of safety Improved water proof properties The terminal block has been modified to improve the insulation performance. (Conforms to overseas standards) The packing is designed to be mated with the plate groove. Improved setscrews The setscrews are not disengaged even if they are excessively loosened. Available M12 connector makes wiring simple. More convenient due to effective use of "Name Plate Installation Hole" You can fix the work instruction nameplate directly. You can place the plate there temporarily during wiring work. This will prevent the plate from being lost. Improved shape of cable entrance The cable entrance slope has been made less sharp to ensure easy cable connection. 1 Improved legibility of nameplate

Handling zTo make an effective use of the wet type solenoid valve, connect the pipe so that the T(R) port is always filled with oil. Do not plug the T(R) port. xTake appropriate measures to ensure that abnormal surge pressure in excess of the maximum permissible backpressure does not occur to the T(R) port. cPlease note that the maximum flow rate is subjected to restriction when you use a four-way valve as a two-way or one-way valve by blocking each port. vKeep the hydraulic oil clean at all times. (Level of contamination: equal to or better than NAS 12 class) bUse the petroleum based hydraulic oil conforming to Class 1 or 2 according to JIS K2213. nWater or glycol based hydraulic oil can be used for the standard valve. In this case, pressure must not exceed 31.5 MPa; further the flow rate must not exceed 80 % of the maximum flow rate. If you want to use other flame resistant hydraulic oil, please contact us for detailed information and precautions. mTake care that the permissible voltage range is not exceeded. ,Turn on the AC solenoid after you have installed the coil on the valve. .Connect a drain pipe to the T(R) port of the valve for operation symbols 2X, H2X and E2X. 0If the product is kept at the switched position for a long time at a high pressure, operation failure may occur due to sticking of fluid. When it must be kept at the switched position for a long time at a high pressure, contact us for further information. 1When you use a detent type valve (E2X, E3X, E3Z), keep power turned on in order to keep the switched position without fail. 2It should be noted that the manual pin operating force is changed by tank line back pressure. 3If you use the valve with power kept turned on, the coil surface temperature will rise. So determine the valve installation position to ensure that your hand will not touch the heated position. Specifications Type Operation symbol JIS symbol b A B P T Standard type Shock-less type Max. working pressure Max. flow rate Max. working pressure Max. flow rate /min MPa{kgf/cm2} /min MPa{kgf/cm2} A2X A B P T a H2X b A B P T A B P T 30 30 a E2X b A3X A B 80 a H3X P T b A B P T A B P T a E3X b 100 A3Z A B P T a H3Z b A B P T 65 a E3Z b A B P T A5 A B P T 35 {357} 25 {255} a H5 b b b b b b b A B P T A B P T A B P T A B P T A B P T A B P T A B P T b a a a a a a a A B P T C2 50 100 C5 C9 C1S C6S C1 C6 AC solenoid 65 DC solenoid 80 A4 A B P T a H4 b b b A B P T A B P T A B P a 50 C4 50 a a C7Y 40 C8 T Note: The maximum flow rate of each valve varies according to the pressure. For details, see page 10. 2

Valve specifications DC solenoid AC solenoid C1 C115 Rectifier built-in type C2 C230 E1 E115 E2 Max. working pressure (ports P, A and B) 35MPa{357kgf/cm2} Permissible back pressure (port T) 21MPa{214kgf/cm2} Switching frequency (times/min.) Standard type 300 Shock-less type — Shock-less — Surge-less G (SS type alone) 300 120 F — G Q — N Quick return — Double solenoid 1.8 2.0 Single solenoid 1.4 1.5 Dust and water SS type protection D2 R (Standard for SS type) With manual pushbutton Mass(kg) D1 120 Indicator light Option E230 JIS C 0920 IP64 (Dust and spray protection type) SA type JIS C 0920 IP65 (Dust and jet protection type) Working Working temperature range -20 – 70 ºC conditions Working viscosity range 15–300mm2/s{cSt} Viscosity index 90 or more Filtration 25 microns or less Installation Size x length bolts Locking torque Hexagon socket head bolts of strength 12T, M5 x 45, four bolts 5–7N m{51–71kgf cm} Note: The valve is not provided with installation bolts. Use the specified bolts. Solenoid assembly specifications Classification of solenoid AC solenoid Power supply type Solenoid SS type coil SA type Voltage(V) C1 C115 C2 C230 EDC64-C1 EDC64-C115 EDC64-C2 EDC64-C230 EAC64-C1 AC100 50 EAC64-C115 AC110 60 AC110 60 50 EAC64-C2 AC115 60 60 AC200 50 EAC64-C230 AC220 60 AC220 60 50 AC230 60 60 Frequency(Hz) Starting current(A) 2.2 2.0 2.2 2.0 1.8 2.0 1.1 1.0 1.1 1.0 0.91 1.0 Holding current(A) 0.52 0.38 0.46 0.47 0.35 0.42 0.26 0.19 0.23 0.24 0.17 0.21 22 28 25 22 28 25 22 28 25 22 28 Holding power(W) 25 Permissible voltage range(V) 80–110 90–120 90–120 100–130 160–220 180–240 180–240 200–260 100 or more (500V) Insulation resistance(MΩ) Classification of DC solenoid solenoid Rectifier built-in type Power supply type E1 E115 E2 E230 D1 D2 Solenoid SS type EDC64-E1-1A EDC64-E115-1A EDC64-E2-1A EDC64-E230-1A EDC64-D1-1A EDC64-D2-1A coil SA type EAC64-E1-1A EAC64-E115-1A EAC64-E2-1A EAC64-E230-1A EAC64-D1-1A EAC64-D2-1A Voltage(V) AC100 Frequency(Hz) Current(A) 50/60 Power(W) Permissible voltage range(V) Insulation resistance(MΩ) 3 AC110 AC115 50/60 AC200 AC220 50/60 AC230 50/60 DC12 DC24 — — 0.31 0.26 0.27 0.15 0.12 0.13 2.2 1.1 27 25 27 26 24 27 26 26 10.8–13.2 21.6–26.4 90–110 100–125 180–220 200–250 100 or more (500V)

Type Description SS - G 01 - A 3 X - ※R - C2 - 31 Design number Power supply indication C: for alternating current (for both 50/60 Hz) C1:AC100V、C115:AC110V C2:AC200V、C230:AC220V D: for direct current D1:DC12V、D2:DC24V E: For alternating current (rectifier built-in type for both 50/60 Hz) E1:AC100V、E115:AC115V E2:AC200V、E230:AC230V Auxiliary symbols (combinations are permitted in alphabetical order) R: With indicator (Write "R"). Standard for SS type, and optional for SA type. F: Shock-less type (applicable to power supply types D※ and E※) G: Surge-less type (applicable to power supply types C※ and D※) GR: Surge-less type with indicator light (applicable to power supply types C※ and D※ of the SA type) J: PG (German Standard) thread with G-thread conversion adaptor (applicable to power supply types C※ and D※ of the SA type. Omitted in the case of power supply type E※ because G thread is used) N: With manual pushbutton Q: Quick return type (applicable to power supply type E※) Form of flow path for transient period (Write only for part of the types A2X, H2X, E2X, ※3※ and C7Y). X Closed Y Semi-open Z Open Neutral position 0 A 1 B P A 2 B A 3 B A 4 B A 5 B B P T(R) T(R) P T T(R) P T(R) P T(R) P A B A B A B A B A B A B P T(R) P T(R) P T(R) P T(R) P T(R) P T(R) 6 7 8 9 T(R) A 1S 6S Note 1: "P" denotes a pressure board, and "A" and "B" indicate communication ports leading to the cylinder or the like. "T(R)" represents a communication port leading to the tank. Operation method A H Spring offset type b A B A B P T P T C E Spring center type Detent type a b A B P T a b A B P T a Nominal diameter 01 size Installation method G: Gasket installation type Model SS: Centralized terminal box type solenoid valve SA: DIN connector type solenoid valve 4

Option (Description of Auxiliary Symbols) Shock-less Type (Type symbol: F) Surge-less type (Type symbol: G) Switching response characteristics Indicates the pressure waveform of valves in the hydraulic circuit given in the following sketch. In the dry type valve, a big impact (noise) or pipe vibration will occur due to sudden pressure drop or rise caused by open/close operation of the valve. In the shock-less solenoid valve, however, there is no pressure change due to open/close operation of the valve. Accordingly, there is no impact (noise) or pipe vibration when the valve is switched. φ 63 φ 35 300 Indicates the surge voltage waveform when the power supply of the DC solenoid valve is turned on or off by a relay. When a surge absorbing element is incorporated, contact spark or surge voltage does not occur. Surge absorber Relay contact W 150kg Power supply SS-G01-※※※-GR-D2-31 R 1Ω Current Voltage A B P T SS-G01-C5-FR-D2-31 Storage oscilloscope P 7MPa(71kgf/F) ( Q 35 ) R/min Sparking time Dry type Shock-less type Manual push button type (Type symbol: N) AC solenoid valve φ 30 Push button Press it and turn it 90 degrees. Then you can lock it. Stroke 7.5 133.5 Handling zUsed to reduce the spring return time for the power supply type E※ (rectifier built-in type). (Same as D※) xFor the SS type, the quick return device is built in the terminal box. For the SA type, it is not built in the terminal box. So install it on the electric box. (For installation dimensions, see the following sketch). cIf two or more quick return devices are used, do not connect the COM cable to the output side (on the side of terminal numbers 3 and 4). 4.5mm (dia), 2 holes 4 2 3 32 M3.5 0.6 5 4 21 5 1 7.5 50 48 36 0.2 φ 30 Stroke 140.5 3 Solenoid 2 Reset time reducing circuit 1 Full-wave rectifier circuit SW Surge absorber Push button Press it and turn it 90 degrees. Then you can lock it. Surge-less type Quick return type (Type symbol: Q) Power supply DC solenoid valve Standard type Terminal number Name plate

Installation Dimension Drawing (SS Series) AC solenoid valve Indicator light SOL b SS-G01-A※※-R-C※-31 SS-G01-H※※-R-C※-31 T Note: For SS-GO1-H※※-R※※-31, the solenoid is located on the side (SOL a) opposite to that shown in the drawing. B A AC solenoid P 2 G (Before PF)1/2 Indicator light SOL a 25.5 48 71.5 87 φ 7.5 37.5 SOL b φ 5.5 66 46 102 Manual push pin 48.5 150.5 Note: Height is different with respect to 30D. 85.5mm 87mm SS-G01-C※※-R-C※-31 SS-G01-E※※-R-C※-31 SOL b SOL a 102 102 204 49.8 Coil mounting/dismounting dimensions With DC solenoid and rectifier SS-G01-A※※-R-D/E※-31 SS-G01-H※※-R-D/E※-31 SS-G01-C※※-R-D/E※-31 SS-G01-E※※-R-D/E※-31 DC solenoid SOL b SOL a 37.5 φ 5.5 109 48.5 157.5 60.5 Sub-plate 7.5 71.5 30 41.5 27 12.7 11.5 27.5 T T B A B P 43.5 ) Note: If you want to use at a pressure of 25 MPa or more, please contact us. 5.1 0.75 ( 98 83 40.5 30.2 21.5 15.5 Gasket surface dimensions ISO4401-03-02-0-94 JIS B 8355 D-03-02-0-94 20 1.2 31 25.9 3/8 7.5 11.5 1.2 25{255} 7.5 12 1/4 31.75 MSA-01X-10 Max. working pressure Mass(kg) MPa {kgf/F} 70 55 E A P 7.5 Type MSA-01Y-10 218 Coil mounting/dismounting dimensions 4 – φ 7.5 4 M5 12 4-Rc "E" 4– φ 9.5 1 Counterbore φ 5.5 Drill through 6

Installation Dimension Drawing (SA Series) AC solenoid valve T SA-G01-A※※-※-C※-31 SA-G01-H※※-※-C※-31 B A Note: For SA-GO1-H※※-R※※-31, the solenoid is located on the side (SOL a) opposite to that shown in the drawing. P AC solenoid φ 7.5 81 92.5 49 37.5 25.5 48 SOL b φ 5.5 46 66 39 102 Manual push pin 141 SA-G01-C※※-R-C※-31 SA-G01-E※※-R-C※-31 SOL b SOL a 102 With DC solenoid and rectifier 102 49.8 SA-G01-A※※-※-D※/E※-31 SA-G01-H※※-※-D※/E※-31 SA-G01-C※※-※-D※/E※-31 SA-G01- E※※-※-D※/E※-31 204 Coil mounting/dismounting dimensions DC solenoid SOL b SOL a φ 5.5 46 109 39 148 Manual push pin 60.5 37.5 25.5 48 (Dimension 2)81 (Dimension 1)92.5 49 218 Coil mounting/dismounting dimensions A fixed throttle valve can be inserted into the ports P, A and B (for both SS and SA types). Notes: 1. For SA-GO1-H※※-※-D※/E※-31, the solenoid is located on the side (SOL a) opposite to that shown in the drawing. φ 7.5 0.1 0.2 φd 7 1.3 φ4 φ 8.3 0.1 0.05 7 9 2. For SA-GO1-※※-E※-31, the dimension 1 is 96mm, and dimension 2 is 73mm.

Connection diagram (SS type) Common terminal Grounding terminal Notes: 1. The double solenoid valve is provided with a common terminal to ensure easy connection. When not used, loosen the set screw of the terminal and remove it. 2. If the ground wire is required, use the grounding terminal. 3. Use the crimp contact for M3. 4. Lock the terminal screw at a torque of 0.5 through 0.7 N-m (5.1 through 7.1 kgf.cm). COM SOL b SOL a SOL b Grounding terminal SOL a Electric circuit diagram (SS type) Model Type Electric circuit 50/60Hz AC solenoid SS-G01-※※※-R-C※-31 COM 50/60Hz AC solenoid, surge-less type SS-G01-※※※-GR-C※-31 COM 50/60Hz Rectifier built-in type SS-G01-※※※-R-E※-31 COM DC solenoid SS-G01-※※※-R-D※-31 COM DC solenoid, surge-less type SS-G01-※※※-GR-D※-31 COM Rectifier built-in quick return type SS-G01-※※※-QR-E※-31 See page 5. 8

Connector (SA type) Type Connection method Electric connection diagram Connect the power supply to the terminals No.1 and No.2. SA-G01-※※※-C※-31 (EA41-1A) COM The terminal marked with 50/60Hz should be used for grounding. COM SA-G01-※※※-R-C※-31 (EA41-R※-1C) 50/60Hz COM SA-G01-※※※-GR-C※-31 (EA41-GRC※-1C) Connect the power supply to the terminals No.1 and No.2. 50/60Hz The terminal marked with should be used for grounding. SA-G01-※※※-R-D※-31 (EA41-DR※-1C) COM Use it whenever required. COM SA-G01-※※※-GR-D※-31 (EA41-GRD※-1C) COM Connect the power SA-G01-※※※-E※-31 (EA42-1B) supply to the terminal on the circuit board. If 50/60Hz connection of a ground wire is required, Power supply remove the circuit terminal board and use the terminal marked with " COM ". In this case, do not connect the power SA-G01-※※※-R-E※-31 (EA42-R※-1B) supply to the terminal 50/60Hz No. 1 or No. 2. G (Before PF)1/2 A symbol in parenthesis indicates a connector type. Notes: 1. The asterisks (※) attached to the connector type and power supply indicating symbols show voltage voltages (1, 2). 2. The connector cord diameter is from 8 through 10 mm. Outside this range, waterproofing function will be lost. 3. The connector can be installed in a desired direction at every 90 degrees by reassembling of the terminal block. 4. The cover can be removed only when the installation set screw has been removed. 5. When there is an auxiliary symbol "J", the connector is provided with the G-thread adaptor, and the wire port is provided with the G (1BFP) 1/2 thread (where PG11 is standard). EA42 and EA42-R※ are also provided with G(1BPF) 1/2 thread. 6. Use the crimp contact having a round shape or the form of a letter Y for M3. 7. Lock the M3 screw for fixing the connector and terminal at a torque of 0.3 through 0.5 N-m (3.1 through 5.1 kgf-cm). 8. In the case of the power supply type E※ of quick return shape Q, use the connector EA-41-1A or EA41-R※-1C. 9

Performance Curve Pressure loss characteristics 2.4 {kgf/cm 2 } 24.5 2.2 22.4 Type P A P B A T B T P T A2X, H2X, E2X d d — — — A3X, H3X b b b b — E3X b b b b — A3Z, H3Z, E3Z a a a a — 20.4 2.0 Pressure loss Flow path f e 1.8 18.4 16.3 1.6 b c 1.4 a A4, H4, C4 a a a a a SS-G01 A5, H5, C5, C6S b b b b — SA-G01 C1, C1S b b a b — 14.3 12.2 1.2 1.0 10.2 8.2 C2 a b b b — 0.6 6.1 C6 b b a a — 0.4 4.1 C7Y f f e e c 2.0 C8 a f b e c C9 a a b b MPa 0.8 d 0.2 20 0 40 60 80 Flow rate 100 — Hydraulic oil viscosity 32mm /s{cSt} 2 r/min Permissible pressure - flow rate values Standard type with AC and DC solenoid Size Operation example Operation symbol b A B P T a b A B P T a b A B P T Shock-less type with DC solenoid Size SS/SA-G01-※※-R-※※-31 SS/SA-G01-※※-FR-※※-31 Operation example a b Operation symbol A B P T a b A B P T a b A B P T A2X, H2X — K K A2X, H2X — P P E2X — J J E2X — O O A3X, H3X B K K A3X, H3X L P P E3X A J J E3X L O O A3Z, H3Z D D D A3Z, H3Z L L L E3Z D D D E3Z L L L A5 A — I A5 L — P H5 A I — H5 L P — C1, C6 Note 1 C(E) I I C1, C6 M P P C1S, C5, C6S A I I C1S, C2, C5, C6S, C9 L P P C2, C9 A K K A4, H4 L L L A4 F F F C4 L L L H4 F F F C7Y, C8 N P P C4 F F F C7Y, C8 Note 2 G(H) K K a Notes: 1. Description in parenthesis is given for an AC solenoid. 2. Description in parenthesis is given for the rectifier built-in type solenoid (E※) except for the quick return type, and for the power supply solenoid (D※) where a surge voltage absorbing diode is mounted on the electric circuit. A 100 C Flow rate 80 B r/min Flow rate D 60 F G 40 H I 20 40 M 30 O N 20 10 E r/min L 50 P 0 10 {102} 20 25 {204} {255} Pressure MPa {kgf/cm2} J K 0 10 {102} 20 {204} 30 35 {306} {357} Pressure MPa {kgf/cm2} 10

Sectional Structure View SS-G01-A3X-R-C※-31 ⑬⑳⑭ ⑮⑯ ⑩⑱⑪⑫⑥⑲ ⑰③① ⑦④⑤⑧② Parts No. Parts name Parts No. 1 Body 11 Rod 2 Plug 12 Solenoid guide 3 Spool valve 13 Solenoid coil 4 Retainer A 14 Packing 5 Retainer B 15 Centralized terminal box kit 6 Special spring pin 16 Name plate 7 Spacer 17 O-ring 8 Spring A 18 O-ring 9 Spring C 19 O-ring 10 Nut 20 O-ring Parts name SS-G01-A3X-R-D/E※-31 ⑬⑳⑭ ⑮⑯ Seal Parts List Parts Parts name No. Quantity Parts type Single solenoid Double solenoid 17 O-ring AS568-012(Hs90) 4 4 18 O-ring 1A-P20 1 2 19 O-ring 1B-P18 2 2 20 O-ring S-25 1 2 Note: 1A and 1B are based on B2401 of the JIS Standards, and AS568 conforms to SAE Standards. ⑩⑱⑪⑫⑥⑲ ⑰③① ⑦④⑤⑧② NACHI-FUJIKOSHI CORP.(TOKYO HEAD OFFICE) World Trade Center,2-4-1 Hamamatsu-cho,Minato-ku,Tokyo 105-6125 Phone: 81-(0)3-3435-5111 Fax: 81-(0)3-3436-2747/6366 URL:http://www.nachi-fujikoshi.co.jp NACHI AMERICA INC. NACHI EUROPE GmbH 17500 Twenty-Three Mile Road, Macomb, Michigan, 48044, U.S.A. Phone: 1-586-226-5151 Fax: 1-888-383-8665 URL:http://www.nachi.com Wiesenstrasse 148,41460 Neuss(Heerdt),GERMANY Phone: 49-(0)2131-26830 Fax: 49-(0)2131-268330/268340 URL:http://www.nachi.de NACHI SINGAPORE PTE. LTD. NACHI(U.K.)LTD. No.2 Joo Koon Way, Jurong Town, Singapore 628943, SINGAPORE Phone: 65-65587393 Fax: 65-65587371 Unit7, Junction Six Industrial Estate, Electric Avenue, Birmingham B6 7JJ, U.K. Phone: 44-(0)121-250-1880 Fax: 44-(0)121-250-1889 URL:http://www.nachi.co.uk CATALOG NO. The appearance and specifications may be changed without prior notice. H1351E 2003.09.X-SE-SE

Note: The valve is not provided with installation bolts. Use the specified bolts. Classification of solenoid Power supply type Voltage(V) Starting current(A) Holding current(A) Holding power(W) Permissible voltage range(V) SS type SA type Solenoid coil Insulation resistance(MΩ) Frequency(Hz) AC solenoid C1 C115 C2 C230

Related Documents:

3X2, 5X2 SINGLE SOLENOID VALVE WITH SPRING RETURN PRODUC T IM A GE SYMBOL 5 3 4 2 1 1 3 2 3X2, 5X2 DOUBLE SOLENOID VALVE PRODUC T IM A GE SYMBOL Function Symbol DOUBLE SOLENOID DOUBLE SOLENOID Model SDA1BN23CT060V0 SVA1BN23CT060V0 1 - Input, 2/4 - Output, 3/5 - Exhaust Port Size IN OUT EXH 1200 LPM at 6 Bar Flow ¼" ¼" ¼" 1200 LPM at 6 .

S - 5,20 bar (75 psi) check Solenoid Energization Identity Blank - Standard arrangement for ANSI B93.9 (i.e. energize solenoid A to follow flow P to A). V - Solenoid identification determined by position of solenoid (i.e. solenoid A at port A end/solenoid B at port B end). Note 4 and 8 type spools are always V. Solenoid

LVM09/090 2/3 port direct operated solenoid Cv 0.018 139 LVM10/100 2/3 port direct operated solenoid Cv 0.03 0.04 139 LVM15/150 & -20/200 2/3 port direct operated solenoid valve Cv 0.015 0.065 140 VDW10, -20 & -30 2/2 solenoid Cv 0.03 0.44 141 VDW200 & -300 3/2 solenoid Cv 0.03 0.44 142 VCA solenoid valve Cv 0.33 2.1 143 N

Solenoid Controlled Pilot Operated Directional Valves Solenoid Controlled Pilot Operated Directional Valves These valves are composed of a solenoid operated pilot valve and a pilot operated slave valve. When a solenoid is energised the pilot valve directs the flow to move the spool of the slave valve, thus changing the direction of flow in the .

the flow rate and pressure. To select the correct valve to fulfill these functions properly, an outline of the different types of valves and their features is given below. Butterfly valve Butterfly valve and globe valve Butterfly valve and ball valve Butterfly valve and gate valve Check valve Gate valve Globe valve Ball valve Valve shaped like a

Servo solenoid valve, pilot operated Servo-distributeur, piloté Regelventil für Blockeinbau Cartridge-type servo solenoid valve Servo-distributeur en cartouche HRV: High Response Valve HRV – Regelventil NG 6 HRV – Servo solenoid valve NG 6 HRV – Servo-distributeur NG 6 Regelventil NG 6 Servo solenoid valve NG 6 Servo-distributeur NG 6

STC Installation and Operation Procedure 3V120-3V420 & 4V120-4V420 Solenoid Valves 4V120-4V420 (4 way valve) SOLENOID VALVE POSITION 1 2 Operations: 1. When Solenoid is OFF (Position 1), Port P is connected to Port A. Port B is connected to Port EB. 2. When Solenoid is ON (Position 2), Port

successfully in captivity, yet animal nutrition is a new and relatively unexplored field. Part of the problem is a lack of facilities in zoological institutions and a lack of expertise. There is, thus, a strong need to develop nutritional studies and departments in zoological institutions. Research on nutrition is carried out both as a problem-solving exercise (in relation to ill-health or .