CATALOG VOL 7 STEEL STUD SYSTEMS SUSPENDED CEILING SYSTEMS DRYWALL SECTIONS LEADERS IN INNOVATIVE BUILDING PRODUCTS

Copyright 2017. This product catalog is not to be reproduced in any form without written permission from STUDCO BUILDING SYSTEMS US LLC. Information printed in this document or communicated by the manufacturers, distributors or any agent is subject to change without notice. STUDCO BUILDING SYSTEMS US LLC will accept no responsibility for the accuracy of information supplied.

INDEX Introduction . 2 Innovation . 2 Quality Assurance. 2 Conformance . 3 Materials Safety & Data Sheet. 4 Marketing & Pricing Policy . 5 Environmental . 5 Certification of Material . 6 Third Party Testing . 7 Engineering. 8 Resources / Resilmount . 9 Part Numbering System .10-11 Drywall Steel Stud Systems 12 Structural Steel Stud Systems 18 Accessories 24 Flat Strap 30 Clips & Connectors 32 Resilmount Sound Isolation Systems 44 EZYJamb & EZYFinishing sections 50 Conditions of Sale . 60 800.675.8023 www.studcosystems.com Phone: 800.675.8023 sales@studcosystems.com 1

www.studcosystems.com INTRODUCTION Introduction Studco Building Systems US LLC (Studco Building Systems) are leaders in manufacturing innovative metal building systems for the wall and ceiling industry. From humble beginnings in 1986 as a steel stud rollformer in Melbourne, Australia, Studco Building Systems has developed into a truly global manufacturer of premium quality building systems for the commercial and residential construction industry. In addition to our wall and ceiling systems, Studco Building Systems also manufactures the patented Ezy-Jamb and Resilmount products. Studco Building Systems has locations in Rochester, NY, UK, New Zealand and four locations within (\Z[YHSPH 6\Y VWLYH[PVUZ HYL JLY[PÄLK [V 0:6 HUK 0:6 Innovation Studco Building Systems - Leaders in Innovative Building Products It takes years of hard work from a dynamic team of dedicated professionals to earn a reputation as a Global industry leader. -VY V]LY LHYZ :[\KJV )\PSKPUN : Z[LTZ OHZ ILLU committed to the development of new and innovative systems and to the continuous improvement of existing systems. Driven by innovation and guided by purpose, Studco Building Systems is resolute about being the leader in delivering original solutions to the North American building and construction industry. At Studco Building Systems, creative thinking is a culture that is fostered and promoted at every level of operations, and everyone has a right to contribute to our continuous improvement program. The results: less labor, safer sites, faster build times and real cost savings. Studco Building Systems is now nationally acclaimed as the leading innovators of smart building products. Mission Statement To Lead In Innovative Building Products Quality ISO 9001 Quality Management System The quest for optimum quality never ends at Studco Building Systems. The consistency of our quality is one of the cornerstones of Studco Building Systems’ reputation as a reliable supplier of metal building systems. In order to achieve dependable quality in our products and ZLY]PJL :[\KJV )\PSKPUN : Z[LTZ PZ JLY[PÄLK [V 0:6 8\HSP[ Management System. This internationally recognized benchmark of quality is rigidly applied to all facets of Studco Building Systems’ operations, ensuring our valued client base of premium quality products and premium customer service at all times. To ensure our customers that our products always offer industrySLHKPUN X\HSP[ V\Y JVTWHU PZ YLN\SHYS Z\IQLJ[LK [V 0:6 auditing by an independent body. Customers can be certain of the quality of Studco Building Systems’ products because of the stringent controls we impose on our production processes. From the moment the raw materials arrive at our manufacturing facilities, we are tracking and recording each step of the product’s journey, right through to the delivery. 2 We can even track the quality of our products long after they have been installed with every product being marked with a distinctive tracking number. Under our continuous improvement program, Studco Building Systems is currently introducing measures that will greatly increase our quality in many areas, including: Introduction of advanced material track and trace systems. Commissioning of new machinery with cutting-edge technology. Review of raw material suppliers quality management systems. Systematic testing of raw materials by independent NATA laboratory. 8\HSP[ THUHNLTLU[ \UKLY [OL 0:6 WYVNYHT WYV]PKLZ WLHJL of mind. It not only means quality products and quality service but also includes effective after sales care and support. Phone: 800.675.8023 sales@studcosystems.com

800.675.8023 :PUJL [OL TPK »Z :[\KJV )\PSKPUN : Z[LTZ TL[HS I\PSKPUN Z Z[LTZ OH]L been the choice of some of North America's largest builders, architects and plastering contractors. Studco Building Systems’ building products have been installed in thousands of buildings throughout North America, Australia, UK and New Zealand in wall systems and ceiling systems from all major lining board manufacturers including National gypsum, USG, Continental and .LVYNPH 7HJPÄJ Studco Building Systems also works closely with a large number of alternative SPUPUN IVHYK Z\WWSPLYZ [V JYLH[L JLY[PÄLK I\PSKPUN Z Z[LTZ MVY H ]HYPL[ VM applications. Our insistence on quality and extensive product testing provide substantial evidence that our products are equal to and provide equivalent performance characteristics of alternative framing systems when used in common wall and ceiling systems, ensuring that the integrity of the plasterboard manufacturer’s warranty is not compromised. Our products and systems have been tested by a variety of independent laboratories and organizations. CONFORMANCE Conformance In the pursuit of ultimate quality and performance, Studco Building Systems’ R&D team has adopted a rigorous program of continuous testing and JLY[PÄJH[PVU [OYV\NO JVSSHIVYH[P]L WHY[ULYZOPWZ P[O ZVTL VM 5VY[O (TLYPJH Z peak research organizations and testing facilities. Studco Building Systems’ wall and ceiling systems have been tested and/ VY JOLJRLK MVY Z[Y\J[\YHS PU[LNYP[ ZLPZTPJ JHWHJP[ ÄYL YH[PUN HUK HJV\Z[PJHS performance, and have consistently demonstrated less than 1% variation in all three areas when compared to similar metal framing systems. As a responsible manufacturer of quality products, we can provide a suite of JLY[PÄJH[LZ MVY V\Y I\PSKPUN Z Z[LTZ MVY V\Y WLHJL VM TPUK! *LY[PÄJH[L VM *VUMVYTHUJL KV USVHK *LY[PÄJH[L VM *VUMVYTHUJL MYVT [OL Studco Building Systems website. 0:6 *LY[PÄJH[L VM *VTWSPHUJL *VTWSPHUJL VM 7O ZPJHS 7YVWLY[PLZ *LY[PÄJH[L WYVQLJ[ ZWLJPÄJ *VTWSPHUJL *LY[PÄJH[L MVY )\PSKPUN LZPNU -VYT WYVQLJ[ ZWLJPÄJ *LY[PÄJH[L VM .\HYHU[LL WYVQLJ[ ZWLJPÄJ PL ZHTWSL JVW VM :[\KJV Building Systems Guarantee on the Studco Building Systems website. ,UNPULLYPUN LZPNU VJ\TLU[H[PVU WYVQLJ[ ZWLJPÄJ *LY[PÄLK 4H[LYPHS ;LZ[ *LY[PÄJH[LZ Many of North America's most respected builders demand Studco Building Systems by choice because they know that no one knows steel like Studco Building Systems. When achieving International standards matter Studco has you covered. :[\KJV»Z NSVIHS VWLYH[PVUZ HYL JLY[PÄLK [V 0:6 8\HSP[ 4HUHNLTLU[ : Z[LT HUK 0:6 ,U]PYVUTLU[HS 4HUHNLTLU[ : Z[LT Phone: 800.675.8023 sales@studcosystems.com 3

www.studcosystems.com MATERIALS SAFETY & DATA SHEET 4 Materials Safety Data Sheet Materials All sections are manufactured from high quality coated steel which is non-hazardous, has reasonable corrosion protection and is immune from biological attack in all its forms. Where severe corrosive conditions prevail, such as acids and salt sprays, extra precautions will be required to ensure the life of the product. Consult Studco Building Systems under these circumstances. Packaging Handling and Storage All framing sections are supplied in strapped bundles of varying weight and length. It is always desirable to leave the strapping in place until they are required as loose elements can be susceptible to damage. Bundles should be kept dry by storing under cover or covering with plastic sheeting as moisture can damage the coatings leading to reduced life and unsightly appearance. Safety Eye Protection – When cutting metal sections, all operators should wear protective non-fogging goggles. Eye protection should conform to North American standard/s. Hand Protection – Appropriate protective gloves should be worn when handling steel components as sharp edges can cause harm and cuts from splinters. Persons who suffer from allergies and sensitive skin conditions should handle metal products with caution and avoid contact with any surface treatments including oils (if present). Hands should be washed for personal hygiene and before eating. Site Training It is the responsibility of the contractor to ensure all workers are instructed and trained in organizational health and safety procedures, foreseeable hazards and controls. Workers must ensure to take reasonable care for their own health and safety and that of others who may be affected by their actions or omissions. Flammability 5VU ÅHTTHISL Note: Mixing of products Any mixing of different manufacturer’s products within a system will void all Guarantees. Studco Building Systems will not be responsible for the structural performance of any structure designed using tables (from Studco Building System’s Wall and Ceiling Design & Installation Manual) and applied to products not manufactured by Studco Building Systems. Any ZWLJPÄJH[PVU HUK KLZPNU JYP[LYPH ZOV\SK IL JVUÄYTLK I [OL project engineer prior to installation. Phone: 800.675.8023 sales@studcosystems.com

800.675.8023 Studco Delivery Guarantee Packaging We will back up our industry-leading delivery service with a guarantee that we will supply complete and accurate orders in accordance with the conditions outlined in the Studco Building Systems Delivery Guarantee. We also guarantee to notify you about any backorders prior to the delivery being made. And if we don’t keep our promise, there will be no delivery charge IT’S FREE*! For products that are delivered on pallets, charges apply unless pallets are returned. Where applicable, products are packed in workable quantities, stock packs and sub packs. Minimum quantities ordered are limited to sub packs. Broken sub-packs may be subjected to a surcharge. Delivery For Metropolitan orders, delivery will be charged unless quantity purchase provisions apply. General Conditions For outside Metropolitan, orders will be invoiced ex store plus freight. Guarantee applies to standard stock items only, as noted in the Studco Building Systems Product Catalogue. Deliveries are normally effected within 48 hours of placement. Due to Studco Building Systems’ WHS policy, drivers are not permitted to hand unload. Please refrain from asking drivers to assist with unloading. Additional delivery services are available at an additional cost. LSP]LY HP[PUN [PTL VU ZP[L TH IL JOHYNLK H[ WLY OV\Y HM[LY [OL ÄYZ[ OV\Y For guaranteed next day, same day or country deliveries order cut-off times apply. 6YKLY JHUJLSSH[PVU MLLZ HWWS PM JHUJLSSLK TPUZ HM[LY receiving order. Special Orders Special size and length products are available from Studco )\PSKPUN : Z[LTZ WYV]PKLK [OH[ [OL TPUPT\T X\HU[P[ PZ SLUN[OZ \USLZZ X\V[LK V[OLY PZL ( YP[[LU JVUÄYTH[PVU VM [OL purchase order is required before manufacturing. Lead times may apply. Excludes weekends and public holidays. Studco Building Systems reserves the right to update this policy and charges from time to time. To avoid disappointment when picking up goods, please allow H TPUPT\T OV\YZ IL[ LLU ZLUKPUN V\Y VYKLY HUK WPJR \W (applicable for loads up to 4 tons; pick up of larger loads by prior appointment only). *Terms and Conditions apply. Contact Studco Building Systems US LLC for full details on Delivery Rates, Scheduled Runs and Order Cut-Off Times for your region. Environmental MARKETING & PRICING POLICY Marketing & Pricing Policy Studco’s Commitment To Environmental Responsibility The management team at Studco has long held the view that caring for the environment is a corporate responsibility. In fact, responsibility of and caring for the environment in which we live is a Studco hallmark which is promoted at every level of our business. :; *6 ,5 09654,5;(3 7630*@ Studco Australia PTY LTD the leading manufacturers of innovative metal building systems for the Wall and Ceiling industry has a commitment to environmental responsibility. This commitment is promoted at every level of our business. Our Organisation is committed to pursuing a high standard of environmental management throughout its operations to minimise the impact of our activities on the environment. Implement and maintain an Environmental Management System in accordance with the requirements of the ISO 14001 Standard Comply with all relevant environmental legislation, and other initiatives to which we subscribe Studco has developed a comprehensive Environmental Policy PU HJJVYKHUJL P[O 0:6 OPJO PUJS\KLZ H IHSHUJLK HUK realistic view of the real issues and a commitment to pursuing a high standard of environmental management throughout our operations to minimize the impact of our activities on the environment. Phone: 800.675.8023 sales@studcosystems.com Incorporate environmental good practice into our core business plans and management processes Minimise negative impacts we may have on the environment, and implement pollution and waste Strive to continually improve of our environmental performance Develop a framework for setting and reviewing our environmental objectives and targets Ensure we work closely with our clients, suppliers, local communities and other interested parties Foster the initiation and ownership of environmental activities by all our staff, thereby building a strong environmentally aware business culture. This Environmental Policy Statement will be communicated to all staff and made available to the public on our website. Ben Stevens Managing Director 14 11 2011 Dated: / / 5

www.studcosystems.com CERTIFICATION OF MATERIALS Certification of Material (SS WYVK\J[Z THU\MHJ[\YLK I :; *6 ) 03 05. :@:;,4: HYL JLY[PÄLK [V TLL[ VY L JLLK HSS HWWSPJHISL (:;4 Z[HUKHYKZ HZ SPZ[LK ILSV :; *6 ) 03 05. :@:;,4: PZ HSZV HJJYLKP[LK [V 0:6 HU internationally recognized standard. Material Specifications (ASTM) (SS :; *6 Y HSS 5VUZ[Y\J[\YHS MYHTPUN TLTILYZ JVUMVYT [V (SS :; *6 :[Y\J[\YHS MYHTPUN TLTILYZ JVUMVYT [V All STUDCO accessories including utility angle, furring channel, *9* JOHUULS HUK HSS YLSH[LK WYVK\J[Z JVUMVYT [V ( ( ( * * * * * * * Coating Specification (ASTM) (SS :; *6 Y HSS 5VUZ[Y\J[\YHS MYHTPUN TLTILYZ JVUMVYT [V (SS :; *6 :[Y\J[\YHS MYHTPUN TLTILYZ JVUMVYT [V All STUDCO accessories including utility angle, furring channel, *9* JOHUULS HUK HSS YLSH[LK WYVK\J[Z JVUMVYT [V Product Specifications (ASTM) (SS :; *6 Y HSS 5VUZ[Y\J[\YHS MYHTPUN TLTILYZ JVUMVYT [V (SS :; *6 :[Y\J[\YHS MYHTPUN TLTILYZ JVUMVYT [V All STUDCO accessories including utility angle, furring channel, *9* JOHUULS HUK HSS YLSH[LK WYVK\J[Z JVUMVYT [V Coating Specification Explanation (SS Y HSS 5VUZ[Y\J[\YHS WYVK\J[Z OH]L H . TPUPT\T LPNO[ JVUMVYTPUN [V (:;4 :WLJPÄJH[PVU ( VY OH]L H WYV[LJ[P]L JVH[PUN P[O [OL PUK\Z[Y Z[HUKHYK YLX\PYLTLU[Z VM (:;4 * (SS :[Y\J[\YHS WYVK\J[Z OH]L H . TPUPT\T LPNO[ JVUMVYTPUN [V (:;4 :WLJPÄJH[PVU ( VY OH]L H WYV[LJ[P]L JVH[PUN P[O [OL PUK\Z[Y Z[HUKHYK YLX\PYLTLU[Z VM (:;4 * ( . *VH[PUN PZ H]HPSHISL \WVU YLX\LZ[ ASTM Specifications Descriptions: ( :[HUKHYK ZWLJPÄJH[PVU MVY Z[LLS ZOLL[ *HYIVU 4L[HSSPJ HUK 5VUTL[HSSPJ *VH[LK MVY *VSK -VYTLK Framing Members * :[HUKHYK ZWLJPÄJH[PVU MVY 5VUZ[Y\J[\YHS :[LLS -YHTPUN 4LTILYZ * :[HUKHYK ZWLJPÄJH[PVU MVY SVHK ILHYPUN [YHUZ]LYZL HUK H PHS Z[LLS Z[\KZ Y\UULYZ [YHJRZ HUK IYHJPUN VY bridging for screw application of gypsum panel products and metal plaster bases * :[HUKHYK ZWLJPÄJH[PVU MVY PUZ[HSSH[PVU VM SH[OPUN HUK M\YYPUN [V YLJLP]L PU[LYPVY HUK L [LYPVY 7VY[SHUK cement-based plaster. UL Specifications (SS Y HSS Z[\KZ JVUMVYT [V :[HUKHYKZ MVY -PYL 9H[LK (ZZLTISPLZ (SS :[Y\J[\YHS :[\KZ *VUMVYT [V :[HUKHYKZ MVY -PYL 9H[LK (ZZLTISPLZ 6 Phone: 800.675.8023 sales@studcosystems.com

800.675.8023 Independent Product Testing & Certifications CIKV.R27210 - Framing Members STUDCO BUILDING SYSTEMS R27210 1700 BOULTER INDUSTRIAL PARKWAY WEBSTER, NY 14580 USA Wall and Partition Facings and Accessories See General Information for Wall and Partition Facings and Accessories Type CROCSTUD steel framing members for use in Design Nos. U375, U403, U419, U465. THIRD PARTY TESTING Third Party Testing Type CROCSTUD Track steel floor and ceiling runner for use in Design Nos. U375, U403, U419, U465. Third Party Independent Testing Phone: 800.675.8023 sales@studcosystems.com 7

www.studcosystems.com TECHNICAL SERVICES Engineering & Design Made Easy For Architects, Engineers & Builders Got any questions about engineering ? Find out the facts and get peace of mind from Studco Technical Services. Studco Technical Services provides tailored construction engineering solutions to contractors, builders and architects for all major projects where Studco products are exclusively used. Studco Technical Services can provide engineering services for installations in the areas of Structural Engineering, Seismic Engineering, Acoustic Engineering and Fire Rated Engineering. 6\Y LUNPULLYPUN ZLY]PJL PZ IHJRLK I X\HSPÄLK Z[Y\J[\YHS engineers and all systems are designed for strict conformance to the latest expectations of all relevant Australian Standards and BCA guidelines. We offer a complete service that covers all aspects of engineering documentation and inspection. Studco Technical 8 Services staff have extensive experience in creating innovative engineering solutions for lightweight steel structures and we can assist you in providing the necessary information. The cost of engineering services varies widely, depending on the particular project requirements. If Studco branded products are exclusively used for the project, Studco Technical Services can provide basic engineering services at no charge to clients who qualify (conditions apply). For acoustically sensitive applications, we can engineer highperformance, resilient-mounted wall and ceiling systems that are code compliant. We are also able to offer advice and support on LULYN LMÄJPLUJ PU HSSZ HUK JLPSPUNZ MVY UL I\PSKPUNZ SOLUTIONS SYSTEMS SERVICES Ease of construction Best value solution Simple designs Certified engineers Simple solutions Internal & external walls Ceiling systems Structural stud systems Top hat systems Sound-rated acoustics Energy-efficient designs Phone: 800.675.8023 sales@studcosystems.com Technical advice Engineering documents Computations Engineer’s opinions Detail drawings On-site support

Read all about the wall and ceiling sound isolation solutions you can trust 800.675.8023 TECHNICAL MANUAL t.com www.resilmoun t.com www.resilmoun Open Web Wood A237R C Fig 16 1 layer of ¾” O.S.B. Wood joist 3 1/2” Batt insulation Fig 13 1 layer of 3/ 4” O.S.B 12”min 12”min 2 Layers of Type Wood Joist with Truss with 1 layer A237R 5/ C 2 layers of 8” Type Gypsum Wallboard 24” A237R 7/ ” 25 gauge drywall 8 furring channel 5/ C 1 layer of 8” Type Gypsum Wallboard 24” Fig 18 7/ ” 25 gauge drywall 8 furring channel Contact Studco today to get your copy. Fig 17 A237R Fig 15 Fig 14 A237R STC 58 IIC 50 2hr Fire Rated STC 54 IIC 46 1hr 3 (::,4)3@ 3 3 (::,4)3@ 3 ACOUSTIC CONSULTING 6705065 m F: 800.675.8023 LLC P:nt.co S US,lmou .resi SYSTEM www NG ING NSULTING ACOUSTIC CONSULTING www.pka.com.au MS g System NG SYSTEM Buildin O BUILDI Studco STUDC Technical Man ual www.resilmounSTUDCO BUILDI .3010 resilmount.com t.com sales@ F: 585.545 E:.8023 800.675 P:.8023 EDITION T: LLC L800.675 5 S US, s US, LLC 8 6705065 www.pka.com.au Fire Rated CR 6” Concrete Slab with 1 layer of unt.com www.resilmo 9 www.resilmoun t.com -3669 *,0305. (::,4)30,: A237 Fig 25 585.545.3010 -3669 *,0305. (::,4)30,: A48R Type C Gypsu m Wallboard 6” Concrete Slab Fig 27 with 1 layer of Fig 29 with one layer um Wallboard of Type X Gyps K TEST AS PER INTERTE Fig 47 6” Concrete 12 GA wire A48R ([[HJOLZ [V IV[O HUK M\YYPUN JOHUULS [V ¹ *9* H KYVWWLK KY HSS JLPSP KLJV\WSL UN 3 5/8” 25 gauge metal stud at 16” O.C. with Fig 48 ( ) C 1 or 2 layers of Gypsum Board 6” Fig 52 12 GA wire 7/8” 25 gauge furring channel Fig 28 24” 6” Insulation M47 Clip 5/ ” Type 8 C Gypsum Wallboard 5/ ” Type 8 C Gypsum Wallboard 12g wire A237CR n R19 Batt insulatio 48” MAX OC Space Resilmou nt A237R so as not to exceed 48” O.C. Secure clips with a single fastener through the middle screw hole in the clip. (Fig 49) Fig 37 Drywall Grid Fig 30 3” - 6” Fig 49 A48R A237CR Clip usage guide 7YV]PKLK P[O ¹ OV SL [OYV\NO MVY TVZ[ JVT TVU MP PUNZ :[YVUN ºJVS\TU» KLZPN Z\IZ[YH[L OPSZ[ THPU[HU WYV]PKLZ TPUPTHS JVU[HJ[ HYLH P[O PUPUN TH PT\T Z[Y\J[\Y HS PU[LNYP[ 7YV]PKLK P[O ZL]LYH S ¹ ZSV[[LK OVSLZ PU Z\YMHJL Z\P[HISL MVY KPY IYHJRL[ LJ[ MHZ[LUPUN HWWSPJH[PV UZ Studs at 16” 56 STC 1hr nt A237R Resilmou drywall Layouts for Studs EDITION 5 Fig 51 ( VVK! #8 x 2-1/2” Coarse Threads ) :[LLS! #8, #10 or #12 x 1-5/8” Self Tapping Type S * *VUJYL[L! 3/16” x 2-1/4” Anchor Screws 6 56; fasten Resilmount clips members with to framing nails. Use only approved screws. On Fire Rated applications Resilmount Fire Washer must be installed as shown in (Fig 47, 48). If this washer is not clip has UV -PYL 9 installed the H[PUN. rd 5/8” Type X Gypsum Wallboa Fig 31 CRC Channel Studco Buildin STUDC g System O BUILDI NG s US, Fasteners nt A237R Resilmou Fire Rated Install ation 6” Concrete Fig 26 12 05:;(33(;065 05:;9 *;06 5: Fig 36 Fig 35 Type C Gypsu m Wallboard M47 Clip 6” Insulation EDITION 5 A237R EDITION 5 www.resilmo unt.com 4,;(3 :; STC 63 IIC 63 Fire Rated LY UL ASSEMB STUDCO BUILDI www NG SYSTEM .resi S US,lmou LLC P:nt.co 800.675.8023 m F: 585.545 ING SYSTEMS US, LLC E 3186856SAT-003 6 1/2” STC 63 IIC 63 9(3 05 00* 9(3 ;3 :;* SYSTEM LLC T: LLC 800.675 S US, P:.8023 800.675E:.8023 sales@ resilmount.com F: 585.545 .3010 Fig 53 P: 800.675.8023 F: 585.545.3010 ;3 15 STUDCO BUILD 9(3 05 00* 9(3 ;3 :;* .3010 for walls and O.C. and Furring ceilings Channel at 24” O.C WIDTH Fig 50 1' to 4' 5' to 8' 9' to 12' 13' to 16' 17' 1' to 2' to 20' 21' to 4 6 24' 25' to 28' 8 3' to 4' 29' to 32' 33' 10 6 12 to 36' 37' to 11 14 14 5' to 6' 40' 16 17 8 18 20 14 23 20 18 7' to 8' 22 26 22 10 29 26 18 32 30 23 9' to 10' 34 35 28 12 38 33 22 42 38 28 11' to 12' 46 43 34 14 48 40 25 53 46 32 13' to 14' 58 52 39 16 58 46 29 H 64 53 37 15' to 16' 70 60 45 18 67 53 33 E 74 61 42 17' to 18' 81 69 51 20 77 60 36 I 85 69 46 19' to 20' 93 78 56 22 87 66 40 G 96 76 51 21' to 22' 105 86 62 24 96 73 44 H 106 84 56 23' to 24' 116 95 68 26 106 80 47 T 117 92 60 25' to 26' 128 104 73 28 116 86 51 128 99 65 27' to 28' 140 112 79 30 125 93 55 138 107 70 29' to 30' 151 121 85 32 135 100 58 149 115 74 31' to 32' 163 130 90 34 145 106 62 160 122 79 33' to 34' 175 138 96 36 154 113 66 170 130 84 35' to 36' 186 147 102 38 164 120 69 181 138 88 37' to 38' 198 107 156 40 126 174 73 145 192 93 39' to 40' 164 210 113 42 183 133 77 202 153 98 221 173 119 193 140 213 161 233 182 203 224 245 HEIGHT ual Technical Man (::,4)30,: -3669 *,0305. m Wallboard of Type C Gypsu A237R Wall and ceiling sound isolation solutions you can trust.globally. EDITION 5 (::,4)30,: -3669 *,0305. ard Gypsum Wallbo EDITION 5 RESOURCES FIRE AND SOUND TESTING ASSEMBLIES Snap hat channel onto Resilmount A237R. (Fig 50) STUDCO BUILD ING SYSTEMS 13 Phone: 800.675.8023 sales@studcosystems.com US, LLC P: 800.675.8023 F: 585.545.3010 19 9

www.studcosystems.com SPECIFYING STUDCO PART NUMBERS PART NUMBERING SYSTEM Type of product (1) Product Mils (3) CS - 358 - 16 MIL (3) SIZE (2) Code Size Code Mils 34 78 112 3/4" 7/8" 1-1/2" 13 15 16 13 Mils 15 Mils 16 Mils 158 212 358 4 6 8 10 12 14 16 1-5/8" 2-1/2" 3-5/8" 4" 6" 8" 10" 12" 14" 16" 18 20 30 33 43 54 68 97 18 Mils 19 Mils 30 Mils 33 Mils 43 Mils 54 Mils 68 Mils 97 Mils TYPE OF PRODUCT (1) CODE 10 Product size (2) TYPE Mil Thickness Flange Web Widths Lip CB CS CT Cornerbead CrocStud Drywall Studs CrocTrack Drywall Track 13 16, 19, 30, 33 16 , 19 , 30 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-5/8" - 8" 1-5/8" - 8" N/A 0.250 N/A DS DST DT DT2.5 DT3 ST CW SS SJ2 SJ2.5 SJ3 SJ3.5 FC CRC RC Drywall Stud 33 KSI Deflection Track 33 KSI Deflection Track 50 KSI Deflection Track Deflection Track Structural Track Curtain Wall Structural Studs Structural Joists Structural Joists Structural Joists Structural Joists Furring Channel Cold Rolled Channel Resilient Channel 15, 18, 30 15, 18, 30 16, 19, 30, 33, 43, 54, 68, 97 30, 33, 43, 54, 68, 97 30, 33, 43, 54, 68, 97 15, 18, 30, 33, 43, 54, 68, 97 33, 43, 54, 68, 97 33, 43, 54, 68, 97 33, 43, 54, 68, 97 43, 54, 68, 97 43, 54, 68, 97 43, 54, 68, 97 18, 30, 33, 43, 54 43, 54 18, 30 1-1/4" 2" 2" 2-1/2" 3" 1-1/4" 1-3/8" 1-5/8" 2" 2-1/2" 3" 3-1/2" N/A N/A N/A 1-5/8" - 3-5/8" 1-5/8" - 16" 1-5/8" - 16" 3-5/8" - 14" 3-5/8" - 14" 1-5/8" - 14" 3-5/8" - 8" 2-1/2" - 16" 3-5/8" - 16" 3-5/8" - 16" 3-5/8" - 16" 3-5/8" - 14" 7/8" , 1-1/2" 3/4" , 1-1/2" 1-1/4" 0.250 N/A N/A N/A N/A N/A 0.375 0.500 0.625 0.625 0.625 1.000 N/A N/A N/A Phone: 800.675.8023 sales@studcosystems.com

800.675.8023 METAL GAUGE Studco Building Systems prides itself on being leaders in quality and innovation. We don’t compromise: VUS 7YPTL .HS]HUPaLK 4H[LYPHS¹ PZ \ZLK HUK L KV UV[ *VSK YLK\JL¹ any of our coil stock CROC STUD Gauge Design Thickness Minimum Thickness Mils Design Inside Corner Radii KSI CROCSTUD25 CROCSTUD20 CROCSTUD30 0.0161 0.019 0.0312 0.0152 0.0181 0.0296 16 19 30 0.08570 0.08425 0.07815 50 50 50 What is Prime Galvanized Steel? Studco uses only Prime Galvanized Steel coil to produce Drywall and Structural Products. Y HSS :[LLS PZ TPUPT\T . OV[ KPWWLK Galvanized coating. Structural Steel is minimum . OV[ KPWWLK NHS]HUPaPUN P[O OPNOLY JVH[PUNZ available upon request. These coatings generally have a spangled appearance. With the current cost cutting taking place in the Z[LLS Z[\K THYRL[ HU ,8 JVH[PUN PZ ILPUN ZVSK [V unsuspecting contractors who don’t know the difference. Be assured . When you order steel from Studco you have the peace of mind that we have you covered, with prime hot dipped galvanized steel. STRUCTURAL STUD Gauge Design Thickness Minimum Thickness Mils Design Inside Corner Radii KSI 20 18 16 14 12 0.0346 0.0451 0.0566 0.0329 0.0428 0.0538 33 43 54 0.07645 0.07120 0.08490 50 50 50 0.0713 0.1017 0.0677 0.0966 68 97 0.10695 0.15255 50 50 Mils Design Inside Corner Radii KSI 15 18 30 0.08600 0.08435 0.07815 33 33 33 PART NUMBERING SYSTEM The modern day steel stud market has moved from offering steel in Gauges which offers H IYVHK YHUNL VM [OPJRULZZ [VSLYHUJLZ [V H YHUNL VM O IYPK ]HYPL[PLZ \UKLY [LYT ,8¹ standing for Equivalent. This has resulted in misunderstandings in relation to what the Architect and contractor alike are expecting as far as the thickness is concerned. As a result Studco Building Systems has moved forward with a decimal system to simplify the industry so that the market understands what they are actually receiving. As a result Studco has released the CrocStud steel framing system based on the new 047,90(3 ,*04(3 :@:;,4¹ The CrocStud Imperial Decimal System is made up of Drywall and Structural steel framing. What does cold reducing mean? Cold Reducing is where a steel coil is passed through a set of rollers to effectively reduce the thickness to gain better yields or feet per ton. As shown in the illustration the steel is thinned down causing the steel to stretch out further in length, reducing the original thickness. This process VYR OHYKLUZ¹ [OL Z[LLS THRPUN [OL Z[\K HUK track products brittle especially on the corners where the galvanized coating can split exposing the uncoated steel. DRYWALL STUD Gauge Design Thickness DRY25L DRY25 DRY20 0.0155 0.0188 0.0312 Minimum Thickness 0.0146 0.0179 0.0296 Phone: 800.675.8023 sales@studcosystems.com 11

DRYWALL STEEL STUD SYSTEMS 12

800.675.8023 DRYWALL STEEL STUD These stud products are used in a variety of applications including internal walls, ceiling systems, and door and

for the wall and ceiling industry. From humble beginnings in 1986 as a steel stud rollformer in Melbourne, Australia, Studco Building Systems has developed into a truly global manufacturer of premium quality building systems for the commercial and residential construction industry. In addition to our wall and ceiling systems, Studco Building

Related Documents:

Use a stud finder to determine the exact center of each steel stud in the vicinity of the mounting location. Use a pencil and mark the exact center of each steel stud. The supplied M6 steel stud anchors must be used to install your mount to steel studs. Do not use lag bolts or wood screws. Steel Stud Anchor Screw Steel Stud Anchor Sleeve X

Stud Welding The stud is placed against the workplace. The stud is lifted off, while current is flowing, thus creating an arc. The arc melts the surfaces of stud and workpiece. The stud is plunged into the weld pool. A cross-sectional joint is achieved. Stud welding with ceramic ferrule Stud welding with shielding gas Short-cycle stud welding with

of each steel stud in the vicinity of the mounting location. Use a pencil and mark the exact center of each steel stud. The supplied M6 steel stud anchors must be used to install your Premier Mounts' mount to steel studs. Do not use lag bolts or wood screws. Steel Stud Anchor Screw Steel Stud Anchor Sleeve X

STUD WELDING-THE PROCESS WHAT IS STUD WELDING ? TYPICAL STUD WELDING SYSTEM Stud Welding is a semi-automatic welding process in which a weld stud, pin, anchor or similar metal part can be end-joined to a parent metal surface instantaneously. This stud welding process involves the same basic principles and metallurgical aspects as any other

13.3 Stud Welding Equipment Rent Stud Welders website www.completestudweld.com e-mail sales@completestudweld.com 32035 Creekside Drive, Cleveland, Ohio 44124 fax 216.378.0349 telephone 216.904.4008 COMPLEtE STUD WELDING Products Service Knowledge Integrity Complete Stud Welding has CD, ARC and Short Cycle stud welders available for rent to satisfy all applications.

WALL COMPONENT: Wood stud displacing a steel stud or concrete block kg CO 2 /m2 Wood stud: Steel stud: Total kg CO 2 reduced Stores net 16.7 Emits 18.0 34.7 Wood stud: Concrete block: Total kg CO 2 reduced Stores net 16.7 Emits 27 .5 44.2 FLOOR COMPONENT: Wood based joistdisplacing a steel kg CO 2 /m2 Dimension joist: Steel joist: Total kg CO

1a). The entire ceiling grid is hung from the structural floor above. The area above the suspended ceiling is called the plenum space and can vary from 0.3m to over 3.0m in commercial buildings. A typical U.S. style suspended ceiling system with acoustic tiles is composed of grid members, boundary wall molding,

Government of Andhra Pradesh Department of School Education State Council of Educational Research & Training DSC SGT – SECOND GRADE TEACHER SYLLABUS 1. G.K & current Affairs - - 10M 2. Perspectives in Education – 05M 3. Educational Psychology – 10M 4. Content & Methodologies - 75M (50 25) Total - 100 M PART - I I. General Knowledge And Current Affairs (Marks: 10) PART - II II .