REDI-TANKS PRODUCT LIST Custom Performance, CARB Certification, and Moeller Quality at an Aftermarket Price In response to builder input, Moeller launched a line of standard-sized EPA/CARB Certified fuel tanks in 2012. The tanks are available in dozens of different configurations and range in capacity from 12 to 100 gallons. Your purchase includes installation guidelines, as well as technical support to assist with any system installation requirements. Redi-Tanks are shipped with all necessary EPA/CARB compliant documentation, and we assist with your fuel system integration and implementation. Note: Moeller builds Redi-Tanks to order. Please allow three weeks for delivery. Tank-Specific Information and Recommendations All tank-specific information and recommendations for angle and tilt were performed such that for all tanks, any of the walls of the tanks may face the front of the boat, except as indicated in the following tank listing. When determining which way a tank should sit in the boat, note the location of the pickup and the fuel sender, and consider the functionality of the unit over varying tip angles. Fuel tanks are sold as complete units and include all tank components, such as the sender, pick-up, Fill Limit Vent Valve (FLVV) and Grade Vent Valve (GRV). Fuel system parts (including the carbon canister, Inlet Check Valve (ICV), deck fill, and P-Trap Vent) are not included with tanks and must be purchased separately. Unless noted, tanks are designed for a canister system. However, all are compatible with pressurized systems, depending on plumbing and the use of an inline Fuel Demand Valve. For more information about Fuel Demand Valves, go to Attwood (http://www.attwoodmarine.com/) or Perko (http://www.perko.com/). For information about canister installation and pre-installation, refer to Attwood installation instructions. If the ICV and/or carbon canister are located in the engine compartment, a heat shield for that component is required, per installation instructions and USCG/ABYC requirements. To satisfy industry and regulatory requirements, consult with Moeller to determine hose lengths and routings. Detailed information about usable gallons by static tip angle and side forward are available from Moeller. For installation guidelines, refer to page 4 of the Redi-Tank brochure. For specific questions, contact your Regional Service Manager or send a message to info@moellermarine.com. Availability of Moeller Redi-Tanks, as well as the configuration of each unit, is subject to change without prior notice. Operating Temperatures Moeller fuel tanks operate at ambient temperatures from -40 F (-40 C) to 176 F (80 C). FIRE AND EXPLOSION HAZARD Fuel leakage from any part of the fuel system may cause a fire or explosion, which may lead to serious injury or death. Periodic inspection of the entire fuel system is important, and is required following storage. All fuel components should be examined for leakage, softening, hardening, swelling, or corrosion. Replace any faulty components and repair any tank damage before further operation. TANK LISTING CONTENTS CAPACITY (GAL) 15 1 CAPACITY (GAL) 29 6 CAPACITY (GAL) 42 17 1 32 6 49 10 19 21 2 35 8 50 11 3 37 8 58 11 25 3 38 9 60 12 26 3 40 9 82 12 27 4 41 9 112 12 PAGE PAGE Moeller Marine Products 801 N. Spring Street Sparta, TN 38583 www.moellermarine.com 800-432-8344 PAGE 10

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 15 GALLON COMPARTMENT STYLE TANK 15 GAL FTA001088BR 0º 13.1 1º 13.1 2º 13.1 3º 13.1 4º 13.1 5º 13.1 0º 14.4 1º 13.8 2º 13.2 3º 12.7 4º 12.2 5º 11.6 0º 14.4 1º 13.8 2º 13.2 3º 12.7 4º 12.2 5º 11.6 (FT1512 ) 17 GALLON PONTOON STYLE TANK 17 GAL FTA001234BR (N/A) 17 GALLON PONTOON STYLE TANK For pressure system only 17 GAL FTA001234BR-2 (N/A) 1 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 17 GALLON PONTOON STYLE TANK 17 GAL FT001751BD 0º 15.3 1º 14.8 2º 14.2 3º 13.7 4º 13.1 5º 12.6 0º 15.3 1º 14.8 2º 14.2 3º 13.7 4º 13.1 5º 12.6 0º 15.95 1º 15.95 2º 15.95 3º 15.95 4º 15.95 5º 15.95 (N/A ) 17 GALLON PONTOON STYLE TANK For pressure system only 17 GAL FT001751BD-1 (N/A ) 19 GALLON CUBE STYLE TANK 19 GAL FTA001103BR ( FT1999 ) 2 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 21 GALLON COMPARTMENT STYLE TANK 21 GAL FTA001092BR 0º 18.7 1º 18.6 2º 18.5 3º 18.4 4º 18.3 5º 18.2 0º 22.7 1º 22.6 2º 22.5 3º 22.2 4º 21.9 5º 221.6 0º 23.9 1º 23.8 2º 23.8 3º 23.7 4º 23.7 5º 23.6 ( FT2143 ) 25 GALLON FLAT STYLE TANK 25 GAL FTA001099BR (FT2599-3) 26 GALLON CUBE STYLE TANK 26 GAL FTA001091BR (FT2631) 3 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 27 GALLON CUBE STYLE TANK 27 GAL FTA001108BR 0º 22.89 1º 22.86 2º 22.83 3º 22.80 4º 22.77 5º 22.74 0º 20.1 1º 21.1 2º 22.1 3º 23.2 4º 24.1 5º 24.6 0º 20.1 1º 21.1 2º 22.1 3º 23.2 4º 24.1 5º 24.6 (FT2399) 27 GALLON PONTOON STYLE TANK 27 GAL FT001550BD-1 (N/A) 27 GALLON PONTOON STYLE TANK For pressure system only 27 GAL FT001550BD-2 (N/A) 4 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 27 GALLON PONTOON STYLE TANK 27 GAL FTA001259BR 0º 24.0 1º 22.9 2º 22.3 3º 21.3 4º 20.5 5º 19.6 0º 24.0 1º 22.9 2º 22.3 3º 21.3 4º 20.5 5º 19.6 0º 22.8 1º 21.9 2º 21.0 3º 20.2 4º 19.4 5º 18.6 (N/A) 27 GALLON PONTOON STYLE TANK 27 GAL FTA001259BR-1 (N/A) 27 GALLON PONTOON STYLE TANK 27 GAL FTA001284BR (N/A) 5 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 29 GALLON BELLY STYLE TANK 29 GAL FTA001109BR 0º 25.0 1º 25.0 2º 25.0 3º 24.9 4º 24.7 5º 24.4 0º 27.1 1º 26.4 2º 25.8 3º 24.9 4º 23.9 5º 22.8 0º 28.6 1º 27.6 2º 26.6 3º 25.7 4º 24.8 5º 23.9 (FT 2926) 32 GALLON BELLY STYLE TANK 32 GAL FTA001122BR (FT3418) 32 GALLON PONTOON STYLE TANK 32 GAL FTA001233BR (N/A) 6 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 32 GALLON PONTOON STYLE TANK For pressure system only 32 GAL FTA001233BR-1 0º 28.6 1º 27.6 2º 26.6 3º 25.7 4º 24.8 5º 23.9 0º 23.0 1º 24.6 2º 26.2 3º 27.9 4º 29.2 5º 29.9 0º 23.0 1º 24.6 2º 26.2 3º 27.9 4º 29.2 5º 29.9 (N/A) 32 GALLON PONTOON STYLE TANK For pressure system only 32 GAL FT001513BD (N/A) 32 GALLON PONTOON STYLE TANK 32 GAL FT001513BD-1 (N/A) 7 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 35 GALLON BELLY STYLE TANK 35 GAL FTA001102BR 0º 31.9 1º 31.9 2º 31.8 3º 31.5 4º 31.1 5º 30.7 0º 32.2 1º 32.1 2º 32.1 3º 32.0 4º 31.9 5º 31.8 0º 32.4 1º 31.9 2º 31.5 3º 31.0 4º 30.5 5º 29.9 (FT3509-1) 37 GALLON CUBE STYLE TANK 37 GAL FTA000926BR (N/A) 37 GALLON COMPARTMENT STYLE TANK 37 GAL FTA001089BR (FT3549) 8 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 38 GALLON CUBE STYLE TANK 38 GAL FTA001093BR 0º 33.3 1º 33.0 2º 32.7 3º 32.5 4º 32.2 5º 31.9 0º 34.46 1º 34.46 2º 34.46 3º 34.46 4º 34.46 5º 34.46 0º 37.40 1º 37.0 2º 36.7 3º 36.3 4º 35.9 5º 35.6 (FT3525BR) 40 GALLON CUBE STYLE TANK 40 GAL FTA001110BR (FT4018) 41 GALLON PONTOON STYLE TANK 41 GAL FT001534BD-1 (N/A) 9 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 41 GALLON PONTOON STYLE TANK 0º 37.40 1º 37.0 2º 36.7 For pressure system only 3º 36.3 41 GAL FT001534BD-2 4º 35.9 5º 35.6 0º 33.3 1º 32.49 2º 31.5 3º 30.6 4º 29.6 5º 28.7 0º 44.5 1º 44.0 2º 43.4 3º 42.7 4º 42.0 5º 41.1 (N/A) 42 GALLON CUBE STYLE TANK 42 GAL FT4221BR-2 (FT4221BR-1) 49 GALLON BELLY STYLE TANK 49 GAL FTA001106BR (N/A) 10 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 50 GALLON BELLY STYLE TANK 50 GAL FTA001105BR 0º 40.0 1º 38.8 2º 37.5 3º 36.2 4º 34.9 5º 33.6 0º 43.1 1º 42.5 2º 42.0 3º 41.5 4º 40.9 5º 40.4 0º 51.0 1º 50.5 2º 50.0 3º 49.5 4º 49.0 5º 48.5 (FT5008) 50 GALLON CUBE STYLE TANK 50 GAL FT5031BD (FT3051) 58 GALLON TALL FLAT STYLE TANK 58 GAL FTA001104BR (FT5899) 11 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANK LIST REV Date: 19 September 2016 Min fill at static angle 0º to 5º Bow Up* 60 GALLON BELLY STYLE TANK 60 GAL FTA000648BR-2 0º 41.2 1º 38.1 2º 35.1 3º 32.0 4º 28.9 5º 25.9 0º 72.1 1º 72.1 2º 72.1 3º 71.8 4º 71.0 5º 70.1 0º 87.5 1º 83.3 2º 79.2 3º 75.0 4º N/A 5º N/A (FTA000648) 82 GALLON FLAT STYLE TANK 82 GAL F FTA001129BR (FT8202) 112 GALLON BELLY STYLE TANK 112 GAL FT11201BR (FT11201) 12 *Worst case maximum volume at fill shutoff gallons for any of the four sides facing the bow of the boat

REDI-TANKS PRODUCT LIST Moeller Marine Products 801 N. Spring Street Sparta, TN 38583 www.moellermarine.com 800-432-8344 Custom Performance, CARB Certification, and Moeller Quality at an Aftermarket Price In response to builder input, Moeller launched a line of standard-sized EPA/CARB Certified fuel tanks in 2012. The tanks are available in

Related Documents:

Take the open space of a Redi-Plex Building and create any floor plan you need. REDI-ACCESS SYSTEMS These steps and ramps are Redi and available to complete your project in record time. Safely. REDI-PLEX BUILDINGS REDI-ACCESS SYSTEMS 5 3 4 12 REDI-PANEL SYSTEMS 070517_MHC_Sweets_

The 60' clear span of a Redi-Plex Building creates a large, columnless space that can remain open or be customized. REDI-PANEL SYSTEMS Take the open space of a Redi-Plex Building and create any floor plan you need. REDI-ACCESS SYSTEMS These steps and ramps are Redi and available to complete your proje

To ensure the Redi-Flo Variable Performance Pumping system operates properly, follow these guidelines: The Redi-Flo2 or Redi-Flo4 pump must be installed vertically with the discharge end pointed upwards. The electrical voltage supply to the Redi-Flo VFD must always be within or - 0% of the specified power supply

Redi-Rock's massive block size allowed taller walls to be built without using geogrid, reducing excavation and preserving valuable space. These qualities made Redi-Rock a natural fit for the Brentwood Stream Stabilization and Flood Control Project, in which the Redi-Rock 9" setback block was used in areas where geogrid was not an option. Redi-

TANK & EQUIPMENT CO. Stationary Tanks Farm Tanks UL 142 Horizontal & Vertical Tanks API 650 Tanks UL 142 Double Wall Tanks UL 2085 “Protected“ Tanks UL 2245 At/Below Grade Tanks Insulated & Jacketed Storage Tanks Chemical Storage & Blending Tanks P.O. Box 2014 Tyler,

REDI-Sensor makes tire service quicker and easier. Ready to install right out of the box. REDI-Sensor is the TPMS se

Common Redi-Rail Accessories. Redi-Rail Runway is compatible with standard accessories for 11/2" runway stringers. Hanger Rod Bracket. 1 1/2" 2" 9ZN-R238 9ZN-R250. Support ATR Size. Part # Hanger Rod Bracket Studded bracket bolts to Redi-Rail holes For 3/8" ATR Load

Thomas Talarico, Nicole Inan . Pennsylvania Policy Forum, from Solicitor, Richard Perhacs, in which he stated "Empower Erie" and the "Western Pennsylvania Policy Forum" are private entities separate and distinct from the County of Erie." Mr. Davis's question to Council regarding this is that, if Empower Erie is separate from the County, why did Tim McNair current Chair of Empower Erie send a .