Guide to Design & Specification of Structured Cabling Systems

DISCLAIMER . 10 PROCEDURE GUIDE INTRODUCTION . 11 ACTIVE COMMUNICATION COMPANY LIMITED . 12 LOCAL AREA NETWORKS . 13 PEER-TO-PEER NETWORKS . 14 CLIENT – SERVER NETWORKS . 15 THIN CLIENT – SERVER . 15 SUMMARY . 16 NETWORK TOPOLOGIES . 16 BUS TOPOLOGY . 16 RING TOPOLOGY . 17 STAR TOPOLOGY. 18 HYBRID TOPOLOGIES . 18 TOPOLOGY EXPANSION & SWITCHES . 19 EXPANSION VIA HUBS. 19 EXPANSION VIA SWITCHES . 19 TRANSMISSION THEORY . 20 ANALOGUE SIGNALS & FREQUENCY . 20 DIGITAL TRANSMISSION AND BIT RATES . 21 BANDWIDTH . 22 DATA THROUGHPUT . 22 ACTUAL DATA TRANSFER . 23 TOKEN RING . 23 ETHERNET TRANSMISSION . 23 ETHERNET FRAMES . 24 BIT ERRORS . 25 TYPES OF INTERFERENCE. 26 BASIC PHYSICS. 27 VOLTAGE . 27 RESISTANCE . 27 AMPS . 27 OHMS LAW . 27 THE OSI REFERENCE MODEL . 28 SERVICES PROVIDED BY EACH PROTOCOL LAYER. 28 Layer 1:. 28 Layer 2:. 29 Layer 3:. 29 Layer 4:. 29 Layer 5:. 29 Layer 6:. 29 Layer 7:. 29 ‘HOP-BY-HOP’ NETWORK-WIDE AND ‘END-TO-END’ COMMUNICATION. 30 THE BASIC STRUCTURE OF LAN CABLING . 31 GENERIC CABLING – SUBSYSTEMS . 31 The three cabling sub-systems are: . 31 The campus backbone cable sub-system consists of the following elements:. 32 The building backbone cable sub-system consists of the following elements: . 32 THE HORIZONTAL CABLING SUB-SYSTEM CONSISTS OF THE FOLLOWING ELEMENTS: . 32 MAXIMUM CABLE LENGTHS . 32

MULTI-USER TELECOMMUNICATIONS OUTLET . 33 MUTO DESIGN IN HORIZONTAL CABLING . 33 THE DESIGN/INSTALLATION CRITERIA FOR THE USE OF A MUTOA INCLUDES THE FOLLOWING: . 33 CONSOLIDATION POINT . 34 The rules for CP design and installation are as follows: . 34 PLANNING GUIDE . 36 EN 5031 . 36 EN 50173 – 1 . 36 EN 50174 – 1 . 36 EN 50174 – 2. 36 EN 50174 – 3. 36 EN 50310 . 36 EN 50174 – 1. 36 EN 50174 – 2 . 36 EN 50174 – 3 . 36 EN 50310 . 36 EN 50346 . 36 EN 50174 – 1. 36 DESIGN . 37 LOGICAL PHASE. 37 INFRASTRUCTURE LAYOUT PHASE . 37 IMPLEMENTATION PHASE . 37 THERE MAY ALSO BE A REQUIREMENT TO OFFER END-USER TRAINING AT THIS STAGE; I.E. EXPLAINING THE LAYOUT SCHEME OF THE PATCH PANELS AND WHICH PATCH PANELS ARE ASSOCIATED WITH DIFFERENT AREAS. 38 OPERATIONS AND MAINTENANCE PHASE . 38 PLANNING RULES. 38 WIRING CONSIDERATIONS . 38 HORIZONTAL CABLE . 39 The information on UTP horizontal cable segregation can be summarized as: . 40 WIRING WITHIN BUILDINGS . 40 EXTERNAL WIRING. 42 PLANNING – ROUTING OF CABLES . 43 CABLE ROUTING OPTIONS . 45 PLANNING – INDEPENDENT TRUNKING/CONDUIT SYSTEM . 46 FIRE CONSIDERATIONS . 47 PLANNING – SECURITY . 47 PLANNING – WAYLEAVES . 48 COPPER DATA COMMUNICATION CABLE . 49 UTP: UNSHIELDED TWISTED PAIR . 49 FTP: FOIL TWISTED PAIR . 49 STP: SHIELDED TWISTED PAIR . 50 PIMF: SCREENED TWISTED PAIR CABLE . 50 SOLID & STRANDED CONDUCTORS . 51 UNDER CARPET CABLE . 51 CONDUCTOR SIZES . 51 VOICE CABLES. 52 CABLE COLOUR CODING . 52 PATCH CORDS . 52 CATEGORIES & CABLE CLASSES . 53 OPTICAL FIBRE IN DETAIL . 54 INTRO TO OPTICAL FIBRE . 54

LIGHT AS THE TRANSMISSION SYSTEM . 55 FIRST WINDOW OF OPERATION . 55 SECOND WINDOW OF OPERATION . 55 THIRD WINDOW OF OPERATION . 56 MULTIMODE . 56 SINGLEMODE. 57 OPTICAL FIBRE TRANSMISSION CHARACTERISTICS. 57 ATTENUATION OR OPTICAL POWER LOSS PER KM . 57 MICRO BENDING LOSS . 58 FRESNEL REFLECTION LOSSES . 58 LOSS-WAVELENGTH CHARACTERISTIC . 59 INTRINSIC OPTICAL FIBRE LOSS . 59 COMPLIANCE TESTING. 61 PULSE DISPERSION . 61 IMPACT OF ISO-11801: 2000 . 62 SINGLEMODE. 62 MULTIMODE . 62 OPTICAL TIME DOMAIN REFLECTOMETER (OTDR). 63 OPTICAL FIBRE INSTALLATION. 63 OPTICAL FIBRE INSTALLATION PRINCIPLES . 63 OPTICAL FIBRE PRE-TEST . 63 CABLE INSTALLATION (PLACEMENT AND HAULING AND SECURING) . 64 OPTICAL FIBRE MAXIMUM TENSILE LOADING . 64 STATIC AND DYNAMIC TENSION . 65 MINIMUM BENDING RADIUS . 65 BOWING, BENDING STRETCHING & PRESSING LOSSES . 65 MICRO BENDING LOSSES . 66 MACRO BENDING LOSSES. 66 TERMINATION OF OPTICAL FIBRES. 66 Desirable features of an optical fibre interconnection device include: . 67 FIBRE CONNECTOR LOSSES. 67 POWER BUDGET . 67 OPTICAL POWER BUDGET - LINK LOSSES . 68 TESTING OVERVIEW. 69 WIRE-MAP . 70 RESULTS INTERPRETATION: WIRE-MAP . 71 WIRE-MAP TROUBLESHOOTING RECOMMENDATIONS . 71 NEAR END CROSSTALK . 72 RESULTS INTERPRETATION: NEAR END CROSSTALK . 73 NEAR END CROSSTALK TROUBLESHOOTING RECOMMENDATIONS . 73 CABLE GEOMETRY . 74 CHARACTERISTIC IMPEDANCE. 75 INPUT IMPEDANCE . 75 NVP. 76 ATTENUATION TO CROSSTALK RATIO . 76 RESULTS INTERPRETATION: ATTENUATION TO CROSSTALK RATIO . 76 ATTENUATION TO CROSSTALK RATIO TROUBLESHOOTING RECOMMENDATIONS . 77

RETURN LOSS. 77 RESULTS INTERPRETATION: RETURN LOSS . 78 RETURN LOSS TROUBLESHOOTING RECOMMENDATIONS . 78 POWER-SUM . 78 FAR END CROSSTALK . 79 LENGTH . 79 RESULTS INTERPRETATION: LENGTH . 80 LENGTH TROUBLESHOOTING RECOMMENDATIONS . 80 DC LOOP RESISTANCE . 81 RESULTS INTERPRETATION: DC LOOP RESISTANCE . 81 DC LOOP RESISTANCE TROUBLESHOOTING RECOMMENDATIONS . 81 PROPAGATION DELAY . 82 RESULTS INTERPRETATION: PROPAGATION DELAY . 82 PROPAGATION DELAY TROUBLESHOOTING RECOMMENDATIONS . 82 PROPAGATION DELAY SKEW . 83 RESULTS INTERPRETATION: PROPAGATION DELAY SKEW . 83 PROPAGATION DELAY SKEW TROUBLESHOOTING RECOMMENDATIONS . 83 ATTENUATION /INSERTION LOSS . 83 RESULTS INTERPRETATION: ATTENUATION OR INSERTION LOSS . 84 ATTENUATION TROUBLESHOOTING RECOMMENDATIONS . 84 INSERTION LOSS DEVIATION . 84 RESULTS INTERPRETATION: INSERTION LOSS DEVIATION . 85 POWER-SUM NEXT. 86 RESULTS INTERPRETATION: POWER-SUM NEXT . 86 POWER-SUM NEXT TROUBLESHOOTING RECOMMENDATIONS . 86 POWER-SUM ATTENUATION TO CROSSTALK RATIO (PSACR). 86 RESULTS INTERPRETATION: POWER-SUM ATTENUATION TO CROSSTALK RATIO (PSACR) . 87 POWER-SUM ATTENUATION TO CROSSTALK RATIO (PSACR) TROUBLESHOOTING RECOMMENDATIONS . 87 FAR END CROSSTALK (FEXT). 87 EQUAL LEVEL FAR END CROSSTALK (ELFEXT) . 87 RESULTS INTERPRETATION: EQUAL LEVEL FAR END CROSSTALK (ELFEXT) . 87 EQUAL LEVEL FAR END CROSSTALK (ELFEXT) TROUBLESHOOTING RECOMMENDATIONS . 88 POWER-SUM EQUAL LEVEL CROSSTALK (PSELFEXT). 88 RESULTS INTERPRETATION: POWER-SUM EQUAL LEVEL CROSSTALK (PSELFEXT) . 88 COUPLING ATTENUATION . 88 RESULTS INTERPRETATION: COUPLING ATTENUATION . 88 ALIEN CROSSTALK . 88 FIBRE OPTICS CABLE TESTING . 89 HOW IS FIBRE TESTED? . 89 WHAT IS REALLY REQUIRED?. 89 Optical Fibre tools for the field include: . 90 FIBRE AND COPPER MEASUREMENT COMPARED . 90 TEST METHODOLOGY . 90 EN/ISO PERMANENT LINK . 91 TIA/EN/ISO CHANNEL . 91 STRUCTURED CABLING STANDARDS. 93 ISO 11801 . 93 BS EN 50173 . 93 BS EN 50174 PART 1 . 93 BS EN 50174 Part II . 93 BS EN 50174 Part III . 93 BS EN 50310 . 93 BS EN 50346 . 93 BS 6701 . 93 METHOD & STANDARDS OF WORKS . 94 HEALTH & SAFETY OBLIGATIONS . 94

ACCL is required by the HSE to provide all employees the following:. 94 ACCL further requires all employees: . 94 RISK ASSESSMENT. 94 SEVERITY (INJURY). 95 LIKELIHOOD (INJURY) . 95 RISK RATING . 95 CONFINED SPACES . 96 Examples of confined spaces include: . 96 Environments where workers may become unconscious or have a fatal incident due to either:. 97 Environments where workers may become unconscious or have a fatal incident due to either:. 97 OVERHEAD WORK . 97 LADDERS . 98 ROOF TOPS . 99 UNDER-FLOOR/GROUND WORKING . 99 GENERAL HOUSEKEEPING . 100 SAFETY . 100 CHEMICAL SAFETY . 100 INSTALLATION SAFETY . 100 ELECTRICAL SAFETY . 101 SIGN SAFETY . 101 FIRE EXTINGUISHERS . 101 The four types of fire extinguisher include: . 102 HALON SYSTEMS . 102 ASBESTOS . 103 ACCL ensures that if any employee who in contact with asbestos that:. 104 ACCL further ensures that employees will not: . 104 ASBESTOS FURTHER: SUGGESTED READING: . 104 BASIC DATA & TELECOMMUNICATIONS TERMINOLOGY. 105 10BASE2. 105 10BASE5. 105 10BASEFL, FB, FP. 105 10BASET . 105 100BASEFX . 105 100BASESX. 105 100BASET . 105 100BASET4 . 105 100VG-A

disclaimer . 10 procedure guide introduction . 11

Related Documents:

PSI AP Physics 1 Name_ Multiple Choice 1. Two&sound&sources&S 1∧&S p;Hz&and250&Hz.&Whenwe& esult&is:& (A) great&&&&&(C)&The&same&&&&&

Argilla Almond&David Arrivederci&ragazzi Malle&L. Artemis&Fowl ColferD. Ascoltail&mio&cuore Pitzorno&B. ASSASSINATION Sgardoli&G. Auschwitzero&il&numero&220545 AveyD. di&mare Salgari&E. Avventurain&Egitto Pederiali&G. Avventure&di&storie AA.&VV. Baby&sitter&blues Murail&Marie]Aude Bambini&di&farina FineAnna

The program, which was designed to push sales of Goodyear Aquatred tires, was targeted at sales associates and managers at 900 company-owned stores and service centers, which were divided into two equal groups of nearly identical performance. For every 12 tires they sold, one group received cash rewards and the other received

College"Physics" Student"Solutions"Manual" Chapter"6" " 50" " 728 rev s 728 rpm 1 min 60 s 2 rad 1 rev 76.2 rad s 1 rev 2 rad , π ω π " 6.2 CENTRIPETAL ACCELERATION 18." Verify&that ntrifuge&is&about 0.50&km/s,∧&Earth&in&its& orbit is&about p;linear&speed&of&a .

theJazz&Band”∧&answer& musical&questions.&Click&on&Band .

6" syl 4" syl 12" swgl @ 45 & 5' o.c. 12" swchl 6" swl r1-1 ma-d1-6a 4" syl 4" syl 2' 2' r3-5r r4-7 r&d 14.7' 13' cw open w11-15 w16-9p ma-d1-7d 12' 2' w4-3 moonwalks abb r&d r&d r&d r&d r&d r&d ret ret r&d r&d r&d r&d r&d 12' 24' r&d ma-d1-7a ma-d1-7b ret r&d r&d r5-1 r3-2 r&d r&r(b.o.) r6-1r r3-2 m4-5 m1-1 (i-195) m1-1 (i-495) m6-2l om1-1 .

HPKB Design Specification Document Data Mining Design Specification Document Non-Traditional Data Design Specification Document HMI Design Specification Document System Integration Design Specification Document 1.4. Software Design Specification Document Development Gui

s& . o Look at the poem’s first and last lines (first and last lines may give readers important . it is important to read poems four times. Remind them that the first time they read is for enjoyment; rereads allow them to dive deeper into poems .