Fire and Gas Detection SystemsGenerating Confidence

Surface mount assemblySurface mount machineCream solderingError detectionQuality controllaboratoryManufacturing TechnologyStability testResearch andDevelopmentPCB designWind tunnelDepotEnvironmentaltest chamberMechanicaldesignDetectorsmoke testchamberFactory and Head Office

Generating ConfidenceMavili Elektronik Tic. ve San. A.S., one of the leading companies in the field of fire and gas detectionsystems, continues generating confidence with the administration mentality of customer deserves thebest quality and service . Since 1987, Mavili has been following the developing technology in the first row.Principally, Mavili actualizes its unwavering customer satisfaction policy not only by its high qualifiedproduction process, but also by novelties in design as well as sales and after sales services.Mavili has continued working in its new factory, which is 5000 square meters, since 2005. The companywhich is improving continuously its service network infrastructure, has offices in Ankara, Ýzmir, Antalyaand Moscow. Export to more then 53 countries and different regions including Russia, Kazakhistan,Turkmenistan, Oman, Bahrain, Central Africa.Mavili continues on manufacturing high quality products, and maintaining services by its dynamic staff.More than 100 people composed of technicians, and engineers are working hard for customers satisfactionAs a proof of Mavili s effort on satisfying customer, Mavili is the first company in the world, who receivedthe certificate of ISO 9001:2008 from LPCB (Loss Prevention Certification Board), world s most prestigiousorganization. Mavili s investments on quality are rewarded with certificates, approvals and user licences;intelligent analog addressable system fire detectors received EN 54-5 and EN 54-7 certificate from LPCB.Most of the products of Mavili have TS EN 54, TSE, SSPB (Russian Fire Security Certification System),GOST (Russian Governmental Standard) certificates and CE sign according to 89/336/EEC EMC directive.Besides, products have Kazakhstan, Oman, and Bahrain Civil Defence approval. Also, Mavigard series gasdetectors are approved by Russia Ecology, Technology, and Atom Energy Department.Within the scope of ISO 9001:2008 quality management system, Mavili provides free technical trainingfor its distributors and clients about installation of products, maintenance, easy fix methods and systemdesign. Participants, who accomplish the training, receive training certificate.Mavili maintains services like project design, technical specification or interpretation of already existingtechnical specification. Furthermore, engaging the installed system, test, technical and maintenanceservices are provided.As a result of more than 30000 worldwide applications including schools, hospitals, dormitories, tradecenters, factories, depots, residents, military establishments, petrochemical plants, dwellings, publicbuildings; Mavili is proud of Generating Confidence .Contents03. About us04. Certificates and approvals05. ReferencesIntelligent analogue addressablefire detection06. Maxlogic ML-125XX series fire alarmcontrol panels08. Maxlogic ML-121X / ML-123X /ML-124X.P series fire alarmcontrol panels10. Harezmic MG-7100 seriesfire alarm control panels11. Harezmic MG-7000 seriesfire alarm control panels12. MG-9000 series fire detectors14. AGD series gas detectors15. Monitor and control modules16. Analogue addressablesystem accessories17. MG-1110 Aspirating smokedetection; high sensitivitysmoke detector18. Supervisor; graphic softwarefor monitoring and managinganalogue addressable system20. System capabilitiesConventional fire detection22. SD64 series fire alarmcontrol panels23. MC series fire alarm control panels24. MP-8 series fire alarm control panels25. MS-64 series fire alarmcontrol panels26. MGRP-64 series repeater panels28. MG / MGR-2000 series fire detectorsExtinguishant control system30. MG-104 series fire extinguishantcontrol panelMarine type LOYD certified firealarm and extinguishant systems32. Intelligent analogue addressablefire alarm control systems33. Conventional fire alarm system andextinguishant systemMesut YavuzManaging DirectorElectrical EngineerConventional gas alarm system34. MG-400 series industrial typecombined gas and fire alarmcontrol panel36. ML-4218 series gas alarm controlpanels and GD2R seriesgas detectors37. GD / GDR / TGDR seriesgas detectors38. Fire and gas alarm systemsaccessories39. MG-1910 series superflow airductsampling unit and ML-0130 seriessmoke test spraywww.mavigard.com 03

Certificates and ApprovalsCertificates: The ISO 9001:2008 Quality Management System that Mavili Elektronik Ticaret Ve Sanayi A.S. has been auditedand conformed by LPCB. Mavili Elektronik is the first company who has received the first ISO:9001:2008 certificate from LPCB inall over the world. * Mavigard intelligent analogue addressable detectors have passed the tests and inspections conducted byLPCB (Loss Prevention Certification Board) and proved that Mavigard intelligent analogue addressable detectors are eligible toreceive EN 54-5 and EN 54-7 certificates. * Mavili Elektronik has been approved EN ISO 9001:2000 Standard by SWEDAC (SwedishBoard for Accreditation and Conformity Assessment) accredited TURK LOYDU. * Mavigard Harezmic series analogue addressablefire alarm control panels, fire detectors and manual call points; SD64 series conventional fire alarm control panels, MG/MGR2000 series fire detectors (standard and with relay output) and manual call points are EN 54 certified. * All Mavigard analogueaddressable and conventional fire detectors are EMC-CE (Electromagnetic Compatibility) certified by KEMA Quality B.V. (TheNetherlands) * All Mavigard products have Russian SSPB (Fire Safety Certification System) certificates given by ANO Normatest.* All Mavigard products are GOST R (Russian State Standard) certified. * Mavigard Marine series fire alarm and extinguishantsystems are tested according to SOLAS 74 and FSS (Fire Safety System) and have TURK LOYDU certificate.Approvals: All Mavigard products are approved by DGPS (State Fire Prevention Service Department of Ministry for EmergencySituations) of Kazakhstan. * All Mavigard products are approved by Directorate General of Civil Defence of Sultanate of Oman. *Conventional fire alarm control panels, fire detectors and Harezmic series analogue addressable fire alarm control system areapproved by General Directorate of Civil Defence of Kingdom of Bahrain. * Mavigard series gas detectors are approved by RussianFederal Department of Ecological, Technological and Atomic Energy Supervision. * Mavili Elektronik is a member of NFPA (NationalFire Protection Association).

ApartmentsAshghabad, TurkmenistanResortGagra,GeorgiaMunicipal Buildingand Clock Tower.Tebriz, IranMulti-Storey Parking Area at Ledovyj Dvorets.Moscow, RussiaCourtHouseAnatolianSideIstanbulSaturn FC Training Facility. Moscow, RussiaDinamoStaduim.Tbilisi, GeorgiaBlue City Project, OmanGrand VictoryHotel&BusinessCentre.KazakhstanKarsan Algida DepotsIstanbul - CorluMore than 30,000 sites aroundthe world are protectedby Mavigard fire and gas alarm systems.www.mavigard.com 05

MaxlogicMaxlogic ML-125XX series intelligent analogueaddressable fire alarm control panelsMaxlogic series fire alarm control panels, offering high performance by the VIP communication protocol,provide 2032 address capacity with its expandable modular structure up to 16 loops.Fire alarmcontrol panel features01. Designed and manufacturedaccording to EN 54-2and EN 54-402. Compatible with MavigardHarezmic series addressabledevices03. Up to 64 panels and/or repeaterpanels can be assembledinto a network04. Extendable loops up to 16 loops,max. 2032 address capacityfor each panel05. 1000 user-defined zonesand 1000 event log memory06. Top priority of fire alarmindication, different buttons forfire and other events, categoricalclassification due to events07. Real time clock08. Communication interrupt for fastfire alarm detection in 1.5 secLoop polling in 7.5 sec09. 4 programmable supervisedremote control inputs10. Protection from electromagneticinterference11. Ability of communication withenhanced computers(RS232/RS485 for close access,GPRS/TCP-IP for remote control)12. Supervised peripheral devices,extension cards (power supply,loop extensions, printer.)13. Day and night mode, pre-alarm,contamination warning14. Virtual panel, supervisorapplications15. Input/output modules can beconnected directly to panel16. Advanced control/monitoringfeatures17. Updating software on the site bythe help of Boot Loader Software18. Advanced parametricarrangement options forinput/output devices19. User-defined event types creationML-125XX.NPTAIntelligent analogue addressable fire alarm control panelincluding network, printer, fire telephone and public announce modulesMaxlogic series intelligent analogue addressable fire alarm control panels use advanced microprocessortechnology for high level security.LCD with 240x64 adjustable blue backlight indicates fire alarm, fault and other information in detail.Panel menu, serigraphy and Loop Manager software have 3 language options as Turkish, Englishand Russian.Addressable detectors, buttons, loop-powered addressable sounders, interface modules (monitor andcontrol modules) and analogue addressable gas detectors can be programmed, in order to operate incause-effect scenarios and the fire automation can be built in this manner.Maxlogic analogueaddressable systemfirefighter telephone canbe applied in a differentlocation from the paneland can be integratedinto communication withthe system.ML-5011Firefighter telephone06 www.mavigard.comPANELMODELSLoopAdressProduct code capacity capacity Product codeLoopAdresscapacity 257.NPTA7889ML-12516.NPTA162032ML-1258.NPTA81016

ML-1203 Printer moduleEvent logs can be printed instantaneouslyor collectively by the printer moduleML-1205 Public announce moduleThe current announcement system ofthe building can be dealt with usingML-50216 Alarm matrix moduleML-125XXFire alarm control panelAvailability of adding optional products into the fire alarm control panel i.e. telephone, public announceand printer modules.Unauthorized people are not allowed to use the system by the help of key control structure.All outputs have latching / non-latching and interruptable options.Possibility to select event type for all input/output devices, as well as user-defined event type creation.0-loop fire alarm control panel models are used as repeater 16162032ML-125881016Product codeDescriptionML-1201Maxlogic intelligent analogue addressableTelephone / Public announcecontrol unitThe use of telephone module andpublic announce module over thepanel is realized with the LCD designedcontrol unit.system network moduleML-1203Maxlogic intelligent analogue addressablesystem printer moduleML-1204Maxlogic intelligent analogue addressablesystem telephone moduleML-1205Maxlogic intelligent analogue addressablesystem public announce moduleML-1206Maxlogic intelligent analogue addressablesystem TCP/IP moduleML-1207Maxlogic intelligent analogue addressablesystem GPRS moduleML-5011Maxlogic intelligent analogue addressablesystem firefighter telephoneML-50112ML-1204 Telephone moduleML-1204 Telephone module realizesthe communication with the firefightertelephones and the telephone modulesin other panels by using ML-501XXFirefighter s telephone control unitMaxlogic firefighter's telephone control unitwith 12 telephone module capacityML-50116Maxlogic firefighter's telephone control unitwith 16 telephone module capacityML-50132Maxlogic firefighter's telephone control unitwith 32 telephone module capacityML-50148Maxlogic firefighter's telephone control unitwith 48 telephone module capacityML-50216Maxlogic alarm matrix module, 16 zoneswww.mavigard.com 07

MaxlogicMaxlogic ML-121X / ML-123X / ML-124X.P seriesintelligent analogue addressable fire alarm control panelsMaxlogic series fire alarm control panels, offering high performance by the VIP communication protocol,provide 1016 address capacity with its expandable modular structure up to 8 loops.Fire alarmcontrol panel features01. Compatible with EN54-2and EN54-402. Compatible with MavigardHarezmic series addressabledevices03. Up to 64 panels and/or repeaterpanels can be assembledinto a network04. Extendable loops up to 8 loops,max. 1016 address capacityfor each panel05. 1000 user-defined zones and1000 event log memory06. Top priority of fire alarmindication, different buttons forfire and other events, categoricalclassification due to events07. Real time clock08. Communication interrupt for fastfire alarm detection in 1.5 sec09. Loop polling in 7.5 sec10. 4 programmable supervisedremote control inputs11. Protection from electromagneticinterference12. Ability of communication withenhanced computers(RS232/RS485 for close access,GPRS/TCP-IP for remote control)13. Supervised peripheral devices,extension cards (power supply,loop extensions, printer.)14. Day and night mode, pre-alarm,contamination warning15. Virtual panel, supervisorapplications16. Input/output modules can beconnected to panel directly17. Advanced control/monitoringfeatures18. Updating software on the site bythe help of Boot Loader software19. Advanced parametricarrangement options forinput/output devices20. User-defined event types creationML-123XFire alarm control unitMaxlogic series intelligent analogue addressable fire alarm control panels use advanced microprocessortechnology for high level security.Addressable detectors, buttons, loop-powered addressable sounders, interface modules (monitor andcontrol modules) and analogue addressable gas detectors can be programmed, in order to operate incause-effect scenarios and the fire automation can be performed in this manner.Unauthorised people are not allowed to use the system by the help of key control structure.All outputs have latching/non-latching and interruptable options.Possibility to select event type for all input/output devices as well as user-defined event type creation.0, 1 and 2-loop models of ML-121X series intelligentanalogue addressable fire alarm panels are available.ML-121X series panels can expand the loop capacityup to 2 in the same cabinet as advantages ofmodular structureML-121X series control panels have exactly thesame technical specification with ML-123X seriesexcept of the loop capacity.ML-121XFire alarm control unit08 www.mavigard.com

LCD with 240x64 adjustableblue backlight indicatesfire alarm, fault and otherinformation in detail.Zone In Alarm: 1 Alarm: 2 Fault: 1*FIRE: MG-8110 Man. Call Point: 430*P: 0 L:1 A:127 ML-1248.PFLOOR CORRIDORZone In Alarm: 1 Alarm: 2 Fault: 1*FIRE: MG-9300 Heat Detector: 860*P: 0 L:6 A:58 ML-1248.P3. FLOOR CAFETERIAML-124X.PFire alarm control panel, with printerML-124X.P series intelligent analogue addressable fire alarm control panels have exactly the sametechnical specification with ML-123X series except of the loop capacity.Printer module is mounted into the steel front cover as standard.Event log can be printed as both instantaneously or collectively. Filtering according to the eventtype is possible.Panel menu, serigraphy and Loop Manager software have 3 language options as Turkish, Englishand Russian.PANELMODELSProduct codeOPTIONALPRODUCTSLoop capacityAddress 6Product codeML-1201DescriptionMaxlogic intelligent analogue addressablesystem network moduleML-1203Maxlogic intelligent analogue addressablesystem printer moduleML-1206Maxlogic intelligent analogue addressablesystem TCP/IP moduleML-1207Maxlogic intelligent analogue addressablesystem GPRS module762762www.mavigard.com 09

Mavigard HarezmicHarezmic MG-7100 Single loop intelligent analogueaddressable fire alarm control panelMG-7100 Fire alarm control panel, offering high performance with the VIP communication protocol,provides 127 address capacity.Fire alarm controlpanel features01. Compatible with EN54-2and EN54-402. 240 x 64 pixel LCD withadjustable blue backlight16 user-defined zones03. 1000 event log memory04. 1 loop and 127 address capacity05. Detailed fire alarmand fault warning06. Real time clock07. Communication interrupt for fastfire alarm detection in 1.5 sec08. Loop polling in 7.5 sec09. 2 programmable and supervisedsounder outputs10. 3 programmable relay outputs11. MG-Thermal printer can bemounted12. Protection against electromagneticinterferenceMG-7100 Fire alarm control panelHarezmic series intelligent analogue addressable fire alarm control panels use advanced microprocessortechnology for high level security.LCD with 240x64 adjustable blue backlight indicates fire alarm, fault and other information in detail.Panel menu, serigraphy and Loop Manager software have 3 language options as Turkish, Englishand Russian.Fire automation can be performed by using control and monitor modules.Addressable detectors, buttons, loop-powered addressable sounders, interface modules (monitor andcontrol modules) and analogue addressable gas detectors can be programmed, in order to operate incause-effect scenarios.Unauthorised people are not allowed to use the system by the help of the key control structure.Control panel has; supervised 2 sounder and 3 relay outputs,which can be programmable just like otheraddressable devices in the system. It is possible to assign two-level, 250 seconds delay into the paneloutputs and 300 seconds delay into the outputs of relay controller module and sounder controllermodule. Once delay is assigned, Delay On LED on the front panel illuminates.In case of more than one event log, the fire alarm logs are displayed of top priority.PANELMODELSProduct codeMG-710010 www.mavigard.comLoop capacityAddress capacity1127Zone capacity16

Mavigard HarezmicHarezmic MG-7000 series intelligent analogueaddressable fire alarm control panelsMG-7000 series fire alarm control panels, offering high performance with the VIP communication protocol,provide 508 address capacity.Fire alarm controlpanel features01. Compatible with EN54-2and EN54-402. 1000 event log memory03. 2 or 4 loop standard models04. Detailed fire alarm and faultwarning information05. Real-time clock06. Soft touch buttons07. Switched mode power supply(Microprocessor-controlled SMPS)08. Communication interrupt for fastfire alarm detection in 1.5 sec09. Up to 32 panels and/or repeaterscan be assembled into a network10. 4 programmable and supervisedsounder outputs11. 3 programmable relay outputs12. Protection against electromagneticinterference13. Hosting up to 127 addresses oneach loop14. LCD (2 x 40 characters) withbacklight15. 48 user-defined zones16. Loop polling in 7.5 sec17. MG-Thermal printer can bemountedMG-7000 series fire alarm control panelHarezmic series intelligent analogue addressable fire alarm control panels use advanced microprocessortechnology for high level security.Provided Ftp Cat6 cable is used, max. cable length between the panels in a RS-485-based network canbe up to 1200m.Panel LCD (2 x 40 characters) with backlight provides fire alarm and fault information in detail. Panelmenu, serigraphy and Loop Manager software have 3 language options as Turkish, English an

Extinguishant control system 30. MG-104 series fire extinguishant control panel Marine type LOYD certified fire alarm and extinguishant systems 32. Intelligent analogue addressable fire alarm control systems 33. Conventional fire alarm system and extinguishant system Conventional gas alarm

Related Documents:

FIRE TOPPER Fire Bowl User Manual Home » FIRE TOPPER » FIRE TOPPER Fire Bowl User Manual Contents [ hide 1 FIRE TOPPER Fire Bowl 2 Setting Up Your Fire Topper Fire Bowl 2.1 Set-Up 3 Placement and Location 3.1 Liquid Propane Tank 4 Using your Fire Topper Fire Bowl - For your safety, read before lighting. 5 Cleaning, Maintenance, Storage 6 .

2.7 UL - 268 UL Standard for Safety Smoke Detectors for Fire Alarm Systems 2.8 EN 54/22 Fire detection and fire alarm systems. Resettable line‐type heat detectors 2.9 EN 54/20 Fire detection and fire alarm systems. Aspirating Smoke detectors 2.10 IS 15519:2004 Water Mist Fire Protection Systems-System Design, Installation

comply with particularly stringent fire detection demands. Smouldering fires Open flames/ exponential development Fully developed fire Very early fire detection (High sensitivity) EN 54-20, Class A Early fire detection (increased sensitivity) EN 54-20, Class B Normal fire detection (normal sensitivity) EN 54-20, Class C/ EN 54-7

fire detection protection systems scope limited to equipments and does not cover disaster management physical evacuation etc . fire detection and protection: intro fire detection system smoke detectors fire alarm panel hooters mcp fire protection system water storage pump house hydrant line hydrant valves hose reels

Fire Detection and Alarm Systems A key aspect of fire protection is to identify a developing fire emergency in a timely manner, and to alert the building's occupants and fire emergency organizations. This is the role of fire detection and alarm systems. Depending on the anticipated fire scenario, building and use type, number

Final Manuscript submitted to the Fire Safety Journal Chen et. al., Fire detection using smoke and gas sensors 2 Fire detection using smoke and gas sensors Shin-Juh Chen1, Chris Hovde1, Kristen A. Peterson1, and André Marshall2 1 Southwest Sciences Inc., Santa Fe, NM 87505, USA 2 Department of Fire Protection Engineering University of Maryland, College Park, MD 20742-3031, USA

Fire Protection Systems Cargo Compartment Fire Verification System - Image based fire/smoke detection (Video-detection) International Aircraft Systems Fire Protection Working Group. Meeting in London on June 13-14th, 2002. Klaus Schmoetzer. Airbus, Dept. ECYM. Fire Protection & Conveyance Systems. 28183 Bremen / Germany. E-mail: klaus .

The fire and gas detection system provides an extra layer of protection to mitigate the consequences when the other safeguarding layers have not been sufficient. The gas detection system can detect a discharge of combustible or toxic gas and take action to minimise the leak and prevent it turning into a fire or explosion. If a fire should result,