Fire Alarm Systems Cataloge

2y ago
52 Views
8 Downloads
4.70 MB
33 Pages
Last View : 1m ago
Last Download : 2m ago
Upload by : Jacoby Zeller
Transcription

Focus on your safely, your strongest security partnerFire Alarm SystemsCatalogeHLogic Security Technology Co.,LtdWWW.HSTFIRE.COMVersion:1.2-2017

Vision

About UsHST (High Security Technology)With an excellent reputation based on more than 20 years’ experience in the fieldof security technology,HST Is one of the most reliable and technologically advanced leadingManufacturer of a vast range of security products especially in production ofFIRE ALARM SYSTEMS.We provide High Quality end to end solutions for our clients from SMB up toLarge Enterprise.Our High Knowledge in Fire Alarm Detection Systems, Which allowed ourfactories specialize in OEM/ODM complete product range of Fire Alarm Systemsinclude:1- Conventional fire alarm system2- Extinguishant control system3- Addressable fire alarm control system4- Alone fire alarm detectorsWith a multiple range of default sized & special Mini Detectors.

QAS ISO9001 Certificate

QAS ISO9001 Certificate

370-CPR-12090370-CPR-1217Intertek EN ApprovalIntertek EN ApprovalUKAS TestingApplus EN ApprovalApplus EN Approval7891012Conventional Fire Alarm SystemHP101Conventional control panel14HP1010Conventional control panel15HD101/102/103Conventional fire alarm detectors16HC102/HB101/HS103Components of conventional system17Schematic diagram of conventional fire alarm system18Extinguishant Control SystemHP102-4Extinguishant Control panel20HF115/116/119Components of extinguishant system21Schematic diagram of extinguishant control system22Addressable Fire Alarm SystemHD201/202/203Addressable fire alarm detectors24HC202/HM201-RAddressable call point & modules25HM201-S/HM201-CAddressable modules26HS201/HM201-IAddressable sounder & modulesHP201Addressable fire alarm control panelSchematic diagram of addressable fire alarm system272829Alone Fire Alarm DetectorsHD104HD106HD105Ultraviolet flame detectorBeam detectorCombustible gas detector313132DG822Alone smoke detector32

Intertek EN ApprovalCert. No.: 0359-CPR-006007HST Canada ,USAAddress: 703 Wild Ginger Ave.Waterloo, OntarioN2V 2T6CanadaTel./Fax: 519 729 9418HST EuropeAddress: Via Teofilo Rossi n. 310123 Torino – ItalyTel.: ( 39) 011 541298Fax: ( 39) 011 549386HST Africa and Middle EastAddress: 4 Abo El-fawares St.-El-Tayaran St.7th Restrict – Nasr City – CairoMob: ( 2) 0111 0444 136 –( 2) 0111 0445 123Tel.: ( 2) 02 227 480 91/92/93/94Fax: ( 2) 02 240 555 37 - 02 240 555 40HST AsiaAddress: 4F, Building B1,XinHaoSheng High-Tech Park,YongHe Road,FuYong Town, Baoan District,Shenzhen, China, PostalCode:518103Tel: 86-755-2959 2202Fax: 86-755-2991 2817

Intertek EN ApprovalCert. No.: 0359-CPR-006118HST Canada ,USAAddress: 703 Wild Ginger Ave.Waterloo, OntarioN2V 2T6CanadaTel./Fax: 519 729 9418HST EuropeAddress: Via Teofilo Rossi n. 310123 Torino – ItalyTel.: ( 39) 011 541298Fax: ( 39) 011 549386HST Africa and Middle EastAddress: 4 Abo El-fawares St.-El-Tayaran St.7th Restrict – Nasr City – CairoMob: ( 2) 0111 0444 136 –( 2) 0111 0445 123Tel.: ( 2) 02 227 480 91/92/93/94Fax: ( 2) 02 240 555 37 - 02 240 555 40HST AsiaAddress: 4F, Building B1,XinHaoSheng High-Tech Park,YongHe Road,FuYong Town, Baoan District,Shenzhen, China, PostalCode:518103Tel: 86-755-2959 2202Fax: 86-755-2991 2817

UKAS TestingCert. No.: TE2743519HST Canada ,USAAddress: 703 Wild Ginger Ave.Waterloo, OntarioN2V 2T6CanadaTel./Fax: 519 729 9418HST EuropeAddress: Via Teofilo Rossi n. 310123 Torino – ItalyTel.: ( 39) 011 541298Fax: ( 39) 011 549386HST Africa and Middle EastAddress: 4 Abo El-fawares St.-El-Tayaran St.7th Restrict – Nasr City – CairoMob: ( 2) 0111 0444 136 –( 2) 0111 0445 123Tel.: ( 2) 02 227 480 91/92/93/94Fax: ( 2) 02 240 555 37 - 02 240 555 40HST AsiaAddress: 4F, Building B1,XinHaoSheng High-Tech Park,YongHe Road,FuYong Town, Baoan District,Shenzhen, China, PostalCode:518103Tel: 86-755-2959 2202Fax: 86-755-2991 2817

UKAS TestingCert. No.: TE27435110HST Canada ,USAAddress: 703 Wild Ginger Ave.Waterloo, OntarioN2V 2T6CanadaTel./Fax: 519 729 9418HST EuropeAddress: Via Teofilo Rossi n. 310123 Torino – ItalyTel.: ( 39) 011 541298Fax: ( 39) 011 549386HST Africa and Middle EastAddress: 4 Abo El-fawares St.-El-Tayaran St.7th Restrict – Nasr City – CairoMob: ( 2) 0111 0444 136 –( 2) 0111 0445 123Tel.: ( 2) 02 227 480 91/92/93/94Fax: ( 2) 02 240 555 37 - 02 240 555 40HST AsiaAddress: 4F, Building B1,XinHaoSheng High-Tech Park,YongHe Road,FuYong Town, Baoan District,Shenzhen, China, PostalCode:518103Tel: 86-755-2959 2202Fax: 86-755-2991 2817

Applus EN ApprovalCert. No.: 0370-CPR-120911

Applus EN ApprovalCert. No.: 0370-CPR-121712

Focus on your safely, your strongest security partnerConventionalFire Alarm System

Conventional Fire Alarm Control PanelModel Number:HP101-04/HP101-08/HP101-16General Description:SpecificationsPrimary AC90-270VAC 50/60 HzPower supply rating3 Amps @ 24VDCALARM&FAULT Relay rating2A & 30VAC, resistiveNormal Initiating OperatingVoltage23VDC, Maximum 26VDC,regulatedMinimum Battery Size 2 x 12VRequired (Ah)7Detector Voltage (V DC)20Number of Sense Zones1 to 16Maximum Number of Detectors30Firing Resistance (Ohms)510 200Sense Zone End of Line (Ohms)4k7Sounder Voltage (V DC)27Number of Sound Zones2Maximum Sound Current per Zone500mAMax. Number Sounder of per Zone5Alarm Zone End of Line (Ohms)Max. Auxiliary Supply Currentin Fire (mA)10kPanel Weight [Without Batteries]4.15kgPanel Dimensions (mm)383 * 295* 87(L*W*D)14500mAThe fire alarm control panels (4 Zones, 8 Zones, and16 Zones) provide all of the sophisticated featuresrequired of a leading edge conventional fire alarmsystem along with the simple operation and efficientinstallation methods demanded by both installers andbuilding users.The panel can be flush or surface mounted and thegenerously sized metal back box allows ample spacefor rear or top cable entries.A comprehensive range of auxiliary devices is availableto operate with the fire control panels including optical,ionization, photoelectric, photoelectric-thermal and heatdetectors.Each of the system components has been specificallydesigned to operate as part of the system.This provides assurance that the control panel, smokedetectors, interface devices and the ancillarycomponents are all fully compatible with one anotherand that the full range of system functionality issupported by each device.HP1016Conventional Fire Alarm RepeaterThe HP1016 Repeater is compatible with allHP101 control panels Repeaters are availablewith 16 zones with 24V powered (DC). Mainspowered repeaters require only a two core datacable from the main control panel. 24V DCversions require an additional two cores forpower either from the main panel or from another24V DC source.A mixture of Repeaters or Ancillary boards up to amaximum of 4 of each type can be connected to acontrol panel and each is allocated an addressfrom 1 to 4 using a binary coded DIP switch. Thetotal length of the data cable from the main panelto the last repeater must not exceed 1.45kg.

Conventional Fire Alarm Control PanelModel Number: HP1010-02/-04/-08/-16General Description:The HP1010 Series conventional fire alarmcontrol panel is a 24 volt, 2 to 16 zones,class B, conventional Fire Alarm Control Panel.Designed exclusively to meet the latest marketrequirements and future ULC codes, the highlycost-effective Series can be used in avariety of low- to mid-sized applications.The panel uses conventional input devices.The panel accepts water flow devices, two-wiresmoken or heat detectors, four-wire smoken orheat detectors,call points and other normally-opencontact devices.Outputs include four Notification Appliance Circuits(NAC, SOUND1-4), three standard Form-A relays(alarm, trouble and supervisory) and an EIA-485 portto interface with repeaters.The panel is field programmable via the panelkeypad. It also supervises all wiring, AC voltageand battery level.Features:2,4,8,16 Class B Initiating Device Circuits (IDCs)All zones accept conventional detectors and anynormally open contact device1-4 Class B Notification Appliance Circuits (NACs)One Form-A Alarm RelayOne Form-A Trouble RelayOne Form-A Supervisory Relay3.0 amps of system powerMax 30 conventional detectors in one zone.Auto/Manual mode setting enable walk test.Each Zone can be disabled15Sound output can be disabled.Manual active sound output enabled.Manual active sound output enabled.Able to report short and broken circuit of detection zones.Designed with standby batteries and space provision fortwo sealed lead-acid batteries.Testing and disable functions.Can connect maximum 32 repeater panels by RS485communication port.SpecificationsPrimary AC90-270VAC 50/60 HzPower supply rating3 Amps @ 24VDCALARM&FAULT Relay ratingNormal Initiating OperatingVoltage2A & 30VAC, resistiveMinimum Battery Size 2 x 12VRequired (Ah)10Ah for 4 to 16 zones4.5Ah for 2 zonesNumber of Sense Zones1 to16Maximum Number of Detectors30Firing Resistance (Ohms)510 20023VDC, Maximum 26VDC,regulatedSense Zone End of Line (Ohms)4k7Sounder Voltage (V DC)27Number of Sound Zones (NACs)1 to 4Maximum Sound Current per Zone500mAMax. Sounder Number of per Zone5Alarm Zone End of Line (Ohms)10kMax. Auxiliary Supply Current(mA)500mAPanel Dimensions (mm)(L*W*D)4 to 16 Zones: 370*440*1002 Zones: 205*258*814 to16 Zones: 6.6kg2 Zones: 2.2kgPanel Weight [Without Batteries]

100 Series Conventional DetectorSpecificationsHD101B Coventional Smoke DetectorOperating VoltageRangeStandby CurrentMaximum AlarmCurrent (LED on)Operating HumidityRangeGeneral Description:This series detector can be used in all areas wherephotoelectric smoke detector,heat detector or multidetector is required. It is suited for fires ranging fromsmoldering to flaming fires.This series detectro is designed to provide open areaprotection and to be used with most conventional firealarm control panel.Two LEDs on each detector provide local 360 visible forindication of status. In the normal condition the LEDsflash red every 5 seconds. When the detector sensessmoke or heat goes into pre-alarm sensitivity the LEDswill flash red every 1 second. When the detector sensessmoke or heat goes into alarm the LEDs will latch on red.The alarm can be reset only by a momentary powerinterruption.The detectors meets the requirements of the EN54-5&7standards and were got the certification by Intertek.16 to 28VDC Volts Non-polarized 40µA @ 24 VDC 30mA @ 24 VDC10% to 93% Relative Humidity,Non-condensingOperating VoltageRange-10 C to 50 CSmoke Sensitivity0.12 to 0.25dB/mHeight55 mm (Installed in Base)Diameter103 mmWeight155 gHD102B Coventional Heat DetectorOperating VoltageRangeStandby CurrentMaximum AlarmCurrent (LED on)Operating HumidityRange16 to 28VDC Volts Non-polarized 40µA @ 24 VDC 30mA @ 24 VDC10% to 93% Relative Humidity,Non-condensingOperating VoltageRange-10 C to 50 CTemperature ClassA2RHeight55 mm (Installed in Base)Diameter103 mmWeight155 gHD103B Coventional Multi DetectorOperating VoltageRangeHS104 Remote LEDGeneral Description:The device is remote LED uses a state of-the-art designs.This LED is designed to be used with detectors.One 8mm LED provide local 360 visible alarm indication.They flash with the same as detector that be connected.Dual Standard Installation Size:4 holes provid USA(83mm) and Europe(59mm) screws width16Standby CurrentMaximum AlarmCurrent (LED on)Operating HumidityRange16 to 28VDC Volts Non-polarized 40µA @ 24 VDC 30mA @ 24 VDC10% to 93% Relative Humidity,Non-condensingOperating VoltageRange-10 C to 50 CSensitivity(Smoke&Heat)0.12 to 0.25dB/m & A2RHeight55 mm (Installed in Base)Diameter103 mmWeight155 g

100 Series Components ofConventional Fire Alarm SystemHC102 Conventional Call PointHB101 Conventional Fire BellGeneral Description:The conventional manual call point designedfor conventional fire alarm system forreporting fire or emergency condition by itsPUSH IN/PULL DOWN handle latches.It is only used with conventional fire alarmcontrol panel.General Description:The conventional fire bell remains the most commonlyused alarm for fire evacuation system, for wallapplications, indoors.The bell is designed to be used in 24 volt DC systemsit meets the requirements of the EN54-3 standards andwas got the certification by Intertek.SpecificationsSpecificationsOperating VoltageRangeStandby CurrentMaximum AlarmCurrent (LED on)Operating HumidityRangeOperating VoltageRange9 to 28VDC 2µA @ 24 VDC 50mA @ 24 VDC10% to 93% Relative Humidity,Non-condensing-10 C to 50 COperating VoltageRangeEnvironment typeMaximum AlarmCurrentOperating HumidityRange16 to 28VDCType A 18mA @ 28 VDC10% to 93% Relative Humidity,Non-condensingOperating VoltageRange-10 C to 50 CAlarm d *W*D)Dimensions(MM)6”, 150*55 (DxH)Weight220 gWeight380git will generate strong audible/audible and visual alarmsignal to warn people in field.SpecificationsOperating VoltageRangeHS103 Conventional Call PointGeneral Description:The Sounder strobe is a kind of audible and visualalarm device installed in field, which can be activatedby fire alarm control panel in fire control center or bymanual call point installed in field. After activated,17Flash IntensityMaximum AlarmCurrentOperating HumidityRange9 to 30VDC 75CD 50mA @ 24 VDC10% to 93% Relative Humidity,Non-condensingOperating VoltageRange-10 C to 50 CMaterialABSSound *W*D)Weight141g

Schematic Diagram ofConventional Fire Alarm System18

Focus on your safely, your strongest security partnerExtinguishantControl System

Extinguishant Control PanelModel Number: HP102-4Components of extinguishant control systemGeneral Description:The automatic extinguisher control panel is designedin accordance with European standards EN54-2 andEN54-4 Fire Detection and Fire Alarm systemsControl and Indicating Equipment and EN12094-1Fixed firefighting systems - Components for gasextinguishing systems - Part 1: Requirements andtest methods for electrical automatic control anddelay devices.The control equipment is a combined fire alarmcontrol panel and extinguishing system and hasfour detection zones, any or all of which are capableof contributing to the extinguishant release decision.Control panels have an integral, mains poweredbattery charger and power supply designed inaccordance with the requirements of EN54-4.Features:Class B Initiating Device Circuits (IDCs)4 zones accept conventional detectors and anynormally open contact device2 Class B Notification Appliance Circuits (NACs)One Form-A Alarm RelayOne Form-A Trouble RelayTwo Form-A Stage Relay3.0 amps of system powerMax 30 conventional detectors in one zone.Each Zone can be disabledSound output can be disabledManual active sound output enabledCan connect max 32 repeater panels byRS485 communication port20SpecificationsPrimary AC90-270VAC 50/60 HzPower supply rating3 Amps @ 24VDCALARM&FAULT Relay ratingNormal Initiating OperatingVoltage2A & 30VAC, resistiveMinimum Battery Size 2 x 12VRequired (Ah)7Number of Sense Zones4Maximum Number of Detectors30Firing Resistance (Ohms)510 200Sense Zone End of Line (Ohms)4k7Sounder Voltage (V DC)27Number of Sound Zones (NACs)2Maximum Sound Current per Zone500mAMax. Sounder Number of per Zone5Alarm Zone End of Line (Ohms)10kMax. Auxiliary Supply Current(mA)500mAExtinguishant release output2 Amp@28VDCExtinguishant release delay timeAdjustable 0 to 75 secondsExtinguishant output end of line10K 5% 1/2 Watt resistorSIL, AL, FLT, RST inputsSwitched – max 1k ohmsTerminal capacity23VDC, Maximum 26VDC,regulated0.5mm2 to 2.5mm2 wiresExtract contact rating2A /30VDC maximum for eachOperating HumidityRange10% to 93% Relative Humidity,Non-condensingOperating Voltage Range-10 C to 50 CPanel Dimensions (mm)383*295*87(L*W*D)Panel Weight [Without Batteries]5kg

100 Series Components ofExtinguishant Control SystemHF115 Manual Release StationHF119 Release Warning SignageGeneral Description:General Description:SpecificationsOperating VoltageRangeSwitch Contact CapacityMaximum AlarmCurrentOperating HumidityRangeSpecifications9 to 30VDCOperating VoltageRange2Amp @24VDCFlash IntensityMaximum AlarmCurrentOperating HumidityRange 50mA @ 24 VDC10% to 93% Relative Humidity,Non-condensing16 to 30VDC 75CD 90mA @ 30 VDC10% to 93% Relative Humidity,Non-condensingOperating VoltageRange-10 C to 50 COperating VoltageRange-10 C to 50 CMaterialABSMaterialABSPanel of PressRecoverableFlash Period1.5 sOperating VoltageRangeHF116 Maintenance SwitchGeneral Description:21Switch Contact CapacityMaximum AlarmCurrent (Led On)Operating HumidityRange9 to 30VDC5Amp @30VDC 20mA @ 30 VDC10% to 93% Relative Humidity,Non-condensingOperating VoltageRange-10 C to 50 CMaterialABSProtection levelIP65Dimensions(MM)115*90*54(L*W*D)Weight237g

Schematic Diagram ofExtinguishant Control System22

Focus on your safely, your strongest security partnerAddressable Fire AlarmControl System

200 Series Addressable DetectorSpecificationsHD201B Addressable Smoke DetectorOperating VoltageRangeStandby CurrentMaximum AlarmCurrent (LED on)Operating HumidityRange16 to 28VDC Volts Non-polarized 320µA @ 28 VDC 5mA @ 28 VDC10% to 93% Relative Humidity,Non-condensingOperating VoltageRange-10 C to 50 CSmoke Sensitivity0.12 to 0.25dB/mGeneral Description:Height55 mm (Installed in Base)This series detector can be used in all areas wherephotoelectric smoke detector,heat detector or multidetector is required. It is suited for fires ranging fromsmoldering to flaming fires.This series detectro is designed to provide open areaprotection and to be used with HST addressable firealarm control panel.Two LEDs on each detector provide local 360 visible forindication of status.In the normal condition the LEDsflash red every scan time of panel.When the detector senses smoke and goes into alarmthe LEDs will latch on red.The alarm can be reset by a instruction from addressablepanel.The address of detector can be set location address byaddressable programmer.The detectors meets the requirements of the EN54-5&7standards and were got the certification by Intertek.Diameter103 mmWeight155 gHD202B Addressable Heat DetectorOperating VoltageRangeStandby CurrentMaximum AlarmCurrent (LED on)Operating HumidityRange16 to 28VDC Volts Non-polarized 320µA @ 28 VDC 5mA @ 28 VDC10% to 93% Relative Humidity,Non-condensingOperating VoltageRange-10 C to 50 CTemperature ClassA2RHeight55 mm (Installed in Base)Diameter103 mmWeight155 gHD203B Coventional Multi DetectorOperating VoltageRangeHLogic Security Technology Co.,Ltd0359-CPR-00600EN54-5&EN54-7Fire detection and fire alarm systems installedin and around buildings.According to Construction ProductsRegulation EU N 305/201124Standby CurrentMaximum AlarmCurrent (LED on)Operating HumidityRange16 to 28VDC Volts Non-polarized 320µA @ 28 VDC 5mA @ 28 VDC10% to 93% Relative Humidity,Non-condensingOperating VoltageRange-10 C to 50 CSensitivity(Smoke&Heat)0.12 to 0.25dB/m & A2RHeight55 mm (Installed in Base)Diameter103 mmWeight155 g

200 Series Addressable Call Point & ModulesHC202 Addressable Call PointHM201-R Addressable Output ModuleGeneral Description:General Description:The HC202 is designed to be used to as a componentThe HM201-R can be installed in a single gang junctionof a fire control system compatible control panel.box directly behind the monitored unit. It is a addressableIt is a dedicating addressable call point for installationoutput module for installation on the 2-wire communicationon the 2-wire communication circuit providing bothcircuit and its location address is written inside the MCU’ssignaling of alarm to the monitoring control panel andEEPROM by the addressable programmer.local led indication of activation.The HM201-R has two output modes can be selected:The HC202 is designed for indo

Extinguishant Control System HP102-4 Extinguishant Control panel 20 HF115/116/119 Components of extinguishant system 21 Schematic diagram of extinguishant control system 22 Addressable Fire Alarm System HD201/202/203 Addressable fire alarm detectors 24 HC202/HM201-R Addressable call poin

Related Documents:

Alarm 1 is a ‘Sound Once’ alarm, and Alarm 2 is an ‘Everyday’ alarm. Alarm 1 Setting/Alarm 2 Setting Press the ‘Alarm 1’ button (Ref.4) or ‘Alarm 2’ button (Ref.5) to activate alarm settings. ‘OFF’ will begin lashing on the screen. Select Alarm 1 or 2 b

Run Card Requirements Continued Structure Fire goes to 7th Alarm and all 7 Alarm and all 7 Alarms are required. Brush Fire goes to 7th Alarm and all 7 Alarm and all 7 alarms are required. All other incident types can go to 4th Alarm Alarm and minimum of 2nd alarm is required.alarm is required. When a Compan

addressable fire alarm control panel 2 loop addressable fire alarm control panel 4 loop addressable fire alarm control panel 6 loop addressable fire alarm control panel 8 loop addressable fire alarm control panel product code: m.u.yan.00016 product code: m.u.yan.00018 battery included product code: m.u.yan.00020 product code: m.u.yan.00022

national fire alarm code, and section 13.7. 2006 nf pa 1. fire alarm system installation and maintenance shal l be in accordance with nfpa 72, national fire alarm code, and 2006 nfpa 1. 13.7.1.4.9.8 audibility. the alarm signal shall be a distinctive sound, which is not used for any other purpose other than the fire alarm. alarm-signaling

DETECTION ZONE 11 DETECTION ZONE 12 ALARM ZONE 1 ALARM ZONE 2 ALARM ZONE 3 ALARM ZONE 4 Alarm Zones An alarm zone is clearly defined within the standard but generally is an area of the building coinciding with the fire compartment boundaries. There must be a clear break between these alarm zones to ensure alert and evacuation messages are not .

2.7 UL - 268 UL Standard for Safety Smoke Detectors for Fire Alarm Systems 2.8 EN 54/22 Fire detection and fire alarm systems. Resettable line‐type heat detectors 2.9 EN 54/20 Fire detection and fire alarm systems. Aspirating Smoke detectors 2.10 IS 15519:2004 Water Mist Fire Protection Systems-System Design, Installation

fire alarm system may be provided with an alarm verification feature, subject to the approval of the relevant authority. The following components of the fire alarm system shall not be subject to this feature; a) Alarm Zone facilities containing only manual call points; b) Circuit between sub-alarm panels and the main alarm panels;

Scrum, Agile Software Development. with Ken Schwaber (Prentice Hall, fall 2001), a provocative book that assumes software development is more like . new product development. than the manufacturing-like processes that the software industry has used for the last 20 years. Arie van Bennekum. has been actively involved in DSDM and the DSDM Consortium since 1997. Before that he had been working .