WIRELESS BINDING GUIDEA step-by-step guide for binding wireless heating controls

This WIRELESS BINDINGGUIDE provides simplestep-by-step instructionsfor binding wirelessheating controls.It’s assumed the devices areappropriately installed andpowered up ready for binding.For full installationinstructions please referto the Installation Guide ofthe individual devices.

ContentsBinding to a Wi-Fi evohomeController (ATC928G3000). 5Binding to a evohomeController (ATC928G2000). 21Digital Room Thermostat (DTS92). 6Mixing Valve Controller (HM80). 7Radiator Controller (HR92). 8Radiator Controller (HR80). 9Room Temperature Sensor (HCF82).10Room Temperature Sensor (HCW82). 11Single Zone Thermostat (T87RF). 12Underfloor Heating Controller (HCE80/HCC80). 13Wireless Cylinder Thermostat (CS92).14Wireless Relay Box (BDR91) Boiler. 15Wireless Relay Box (BDR91) Sundial Valve.16Wireless Relay Box (BDR91) Zone Valve.17Wireless Relay Box (HC60NG).18Wireless OpenTherm Bridge (R8810). 19Digital Room Thermostat (DTS92). 22Mixing Valve Controller (HM80). 23Radiator Controller (HR92).24Radiator Controller (HR80). 25Remote Access Gateway (RFG100). 26Room Temperature Sensor (HCF82).27Room Temperature Sensor (HCW82). 28Single Zone Thermostat (T87RF). 29Underfloor Heating Controller (HCE80/HCC80). 30Wireless Cylinder Thermostat (CS92).31Wireless Relay Box (BDR91) Boiler. 32Wireless Relay Box (BDR91) Sundial Valve. 33Wireless Relay Box (BDR91) Zone Valve. 34Wireless Relay Box (HC60NG). 35Wireless OpenTherm Bridge (R8810). 362

ContentsBinding to a Digital RoomThermostat (DTS92). 37Binding to a ProgrammableThermostat (CM700RF). 49Wireless Relay Box (BDR91). 38Wireless OpenTherm Bridge (R8810). 39Wireless Relay Box (BDR91). 50Wireless Relay Box (HC60NG).51Wireless OpenTherm Bridge (R8810). 52Binding to a Single ZoneThermostat (T87RF). 41Remote Access Gateway (RFG100).42Wireless Relay Box (BDR91). 43Wireless OpenTherm Bridge (R8810). 44Binding to a ProgrammableThermostat (CM900RF). 45Wireless Relay Box (BDR91). 46Wireless Relay Box (HC60NG).47Wireless OpenTherm Bridge (R8810). 48Binding to a Programmer orTimer (ST9000RF). 53Digital Room Thermostat (DTS92). 54Wireless Cylinder Thermostat (CS92). 55Wireless Relay Box (BDR91) Boiler. 56Wireless Relay Box (BDR91) Sundial Valve. 57Wireless OpenTherm Bridge (R8810). 583

4

Wi-Fi evohome Controller (ATC928G3000)Binding to aWi-Fi evohome Controller (ATC928G3000)5

Wireless connectivity GuideWi-Fi evohome Controller(ATC928G3000)Digital RoomThermostat (DTS92)To bind a Digital Room Thermostat (DTS92) to a Wi-Fi evohome Controller(ATC928G3000) as the room temperature sensor in a zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE CONFIGURATION4 Press on the required zone5 Press TEMPERATURE SENSOR6 Press REMOTE SENSOR7 Press the green tick1On the Digital Room Thermostat86 Press and holdfor 2 secondsto put the unit into standby Press and together for 3seconds – it should display 'INst'10 Press– it should display 'COnt'11 Pressthree times – it should display 'CLr'12 Pressonce to clear any previous binding data13 Press– it should display 'COnt'14 Pressonce to send the bindingsignal to the evohome Controller9 ou should receive a SUCCESS message on theYevohome Controller. If not go back and re-bind.

Wi-Fi evohome Controller (ATC928G3000)Wi-Fi evohome Controller(ATC928G3000)Mixing Valve Controller(HM80)To bind a Mixing Valve Controller (HM80) to a Wi-Fi evohomeController (ATC928G3000) “mixing valve” zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE CONFIGURATION4 Press on the required zone5 Press HEATING TYPE6 Press MIXING VALVE7 Press the green tick1On the Mixing Valve Controller8 Press and hold both buttons on theMixing Valve Controller for 4 secondsuntil the red light flashesOn the evohome Controller9 Press the bind button ou should receive a SUCCESS message on theYevohome Controller. If not go back and re-bind.The Mixing Valve Controller will not provide aheat demand to the boiler. If you want this zone toprovide a heat demand change the Heating Typefrom 'MIXING VALVE' to 'ZONE VALVES' once theMixing Valve controller is bound. There's no needto re-bind any device – The Mixing Valve Controllerwill still operate as intended and the evohomeController will send the heat demand to the boiler.7

Wireless connectivity GuideWi-Fi evohome Controller(ATC928G3000)Radiator Controller(HR92)To bind a Radiator Controller (HR92) to a Wi-Fi evohomeController (ATC928G3000) “radiator valve” zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE CONFIGURATION4 Press on the required zone5 Press RF DEVICE BINDING6 Press the forward arrow1On the Radiator Controller Press the button once itshould display UNBOUND8 Press and hold thebutton for a further5 seconds until it displays BIND789 Press the button once – itshould display BINDINGOn the evohome Controller10 Pressthe bind button ou should receive a SUCCESS message onYboth the evohome Controller and the RadiatorController. If not go back and re-bind.

Wi-Fi evohome Controller (ATC928G3000)Wi-Fi evohome Controller(ATC928G3000)Radiator Controller(HR80)To bind a Radiator Controller (HR80) to a Wi-Fi evohomeController (ATC928G3000) “radiator valve” zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE CONFIGURATION4 Press on the required zone5 Press RF DEVICE BINDING6 Press the forward arrow81On the Radiator Controller7 Press the recessed bind button on theunderside of the Radiator Controller – it shouldbriefly show a flashing RF icon then SYNC. Press the recessed bind button again – itshould show a flashing RF iconOn the evohome Controller9 Press the bind buttonThe evohome Controller will not show a SUCCESSmessage. It’s recommended to perform aquick functional check to validate the bind.To do this, adjust the setpoint temperature onthe evohome controller for that zone to themaximum and minimum, checking the radiatorcontroller responds to the new setpoint.9

Wireless connectivity GuideWi-Fi evohome Controller(ATC928G3000)Room TemperatureSensor (HCF82)To bind a Room Temperature Sensor (HCF82) to a Wi-Fi evohome Controller(ATC928G3000) as the room temperature sensor in a zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE CONFIGURATION4 Press on the required zone5 Press TEMPERATURE SENSOR6 Press REMOTE SENSOR7 Press the green tick110On the Room Temperature Sensor8 Press the bind button on the bottomright hand corner of the unit once– the red LED light will flash ou should receive a SUCCESS message on theYevohome Controller. If not go back and re-bind.

Wi-Fi evohome Controller (ATC928G3000)Wi-Fi evohome Controller(ATC928G3000)Room TemperatureSensor (HCW82)To bind a Room Temperature Sensor (HCW82) to a Wi-Fi evohome Controller(ATC928G3000) as the room temperature sensor in a zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE CONFIGURATION4 Press on the required zone5 Press TEMPERATURE SENSOR6 Press REMOTE SENSOR7 Press the green tick1On the Room Temperature Sensor8 Press the bind button on the bottomright hand corner of the unit once– the red LED light will flash ou should receive a SUCCESS message on theYevohome Controller. If not go back and re-bind.11

Wireless connectivity GuideWi-Fi evohome Controller(ATC928G3000)Single ZoneThermostat (T87RF)To bind a Single Zone Thermostat (T87RF) to a Wi-Fi evohome Controller(ATC928G3000) as the room temperature sensor in a zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE CONFIGURATION4 Press on the required zone5 Press TEMPERATURE SENSOR6 Press REMOTE SENSOR7 Press the green tick1On the Single Zone Thermostat8 Press and hold on the left touch zone (just belowand to the left of the display) for approximately10 seconds until a flashing ‘Bo’ is displayed12 Turn the dial clockwise until aflashing ‘Co’ is displayed10 Press the left touch zone once to send thebinding signal to the evohome Controller9You should receive a message on the evohomeController to say the binding signal wasreceived. If not go back and re-bind.

Wi-Fi evohome Controller (ATC928G3000)Wi-Fi evohome Controller(ATC928G3000)Underfloor HeatingController (HCE80/HCC80)We recommend that you refer to the fullevohome Controller installation guidewhen binding the Underfloor HeatingController. This product will include arange of different actuators and sensorsused across the underfloor heating zones,with a variety of binding procedures.13

Wireless connectivity GuideWi-Fi evohome Controller(ATC928G3000)Wireless CylinderThermostat (CS92)To bind a Wireless Cylinder Thermostat (CS92) to a Wi-Fi evohomeController (ATC928G3000) to control a hot water cylinder.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press SYSTEM DEVICES4 Press STORED HOT WATER5 Press ENABLED6 Press HOT WATER SENSOR BINDING114On the Wireless Cylinder Thermostat Press and hold the button for 5seconds. The green light should comeon and the red light should flash8 Press the button again7You should receive a SUCCESS message onthe evohome Controller and the LED on theWireless Cylinder Thermostat should stop blinkingand turn OFF. If not, go back and re-bind.

Wi-Fi evohome Controller (ATC928G3000)Wi-Fi evohome Controller(ATC928G3000)Wireless Relay Box(BDR91) BoilerTo bind a Wireless Relay Box (BDR91) to a Wi-Fi evohomeController (ATC928G3000) to control a boiler.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press SYSTEM DEVICES4 Press BOILER CONTROL5 Press WIRELESS RELAY BOX1On the evohome Controller8 Press the bind buttonYou should receive a SUCCESS messageon the evohome Controller and the LED onthe Wireless Relay Box should stop blinkingand turn OFF. If not, go back and re-bind.On the Wireless Relay Box Press and hold the button for 15 seconds(until the red LED blinks rapidly) toclear any previous binding data7 Press and hold the button again for 5seconds (until the red LED blinks slowly)615

Wireless connectivity GuideWi-Fi evohome Controller(ATC928G3000)Wireless Relay Box(BDR91) Sundial ValveTo bind a Wireless Relay Box (BDR91) to a Wi-Fi evohome Controller(ATC928G3000) to control a Sundial valve (hot water or heating).On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press SYSTEM DEVICES4 Press STORED HOT WATER5 Press ENABLED6 Press HOT WATER VALVE BINDINGor HEATING VALVE BINDING81On the Wireless Relay Box7 Press and hold the button for 15 seconds(until the red LED blinks rapidly) toclear any previous binding data16 Press and hold the button again for 5seconds (until the red LED blinks slowly)On the evohome Controller9 Press the bind buttonYou should receive a SUCCESS messageon the evohome Controller and the LED onthe Wireless Relay Box should stop blinkingand turn OFF. If not, go back and re-bind.

Wi-Fi evohome Controller (ATC928G3000)Wi-Fi evohome Controller(ATC928G3000)Wireless Relay Box(BDR91) Zone ValveTo bind a Wireless Relay Box (BDR91) to a Wi-Fi evohomeController (ATC928G3000) Zone Valve zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE CONFIGURATION4 Press on the required zone5 Press HEATING TYPE6 Press ZONE VALVE7 Press the green tick19 Press and hold the button again for 5seconds (until the red LED blinks slowly)On the evohome Controller10 Pressthe bind buttonYou should receive a SUCCESS messageon the evohome Controller and the LED onthe Wireless Relay Box should stop blinkingand turn OFF. If not, go back and re-bind.On the Wireless Relay Box8 Press and hold the button for 15 seconds(until the red LED blinks rapidly) toclear any previous binding data17

Wireless connectivity GuideWi-Fi evohome Controller(ATC928G3000)Wireless Relay Box(HC60NG)To bind a Wireless Relay Box (HC60NG) to a Wi-Fi evohomeController (ATC928G3000) to control a boiler.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press SYSTEM DEVICES4 Press BOILER CONTROL5 Press WIRELESS RELAY BOX1On the Wireless Relay Box Press and hold the button for 15 seconds(until the red LED blinks rapidly) toclear any previous binding data7 Press and hold the button again for 5seconds (until the red LED blinks slowly)618On the evohome Controller8 Press the bind buttonYou should receive a SUCCESS messageon the evohome Controller and the LED onthe Wireless Relay Box should stop blinkingand turn OFF. If not, go back and re-bind.

Wi-Fi evohome Controller (ATC928G3000)Wi-Fi evohome Controller(ATC928G3000)Wireless OpenThermBridge (R8810)To bind a OpenTherm Bridge (R8810) to a Wi-Fi evohome Controller(ATC928G3000) to control an OpenTherm boiler.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press SYSTEM DEVICES4 Press BOILER CONTROL5 Press OPENTHERM BRIDGE1On the evohome Controller8 Press the bind buttonYou should receive a SUCCESS message onthe evohome Controller and the LED on theWireless OpenTherm Bridge should stop blinkingand turn OFF. If not, go back and re-bind.On the OpenTherm Bridge Press and hold the button for 15 seconds(until the red LED blinks rapidly) toclear any previous binding data7 Press and hold the button again for 5seconds (until the red LED blinks slowly)619

Wireless connectivity Guide20

evohome Controller (ATC928G2000)Binding to aevohome Controller (ATC928G2000)21

Wireless connectivity Guideevohome Controller(ATC928G2000)Digital RoomThermostat (DTS92)To bind a Digital Room Thermostat (DTS92) to an evohome Controller(ATC928G2000) as the room temperature sensor in a zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE SETTINGS4 Press EDIT ZONE5 Press on the required zone6 Press the button next to “Sensor:”7 Press REMOTE RF DEVICE’S SENSOR1On the Digital Room Thermostat8 Press and holdfor 2 secondsto put the unit into standby22 Press and together for 3seconds – it should display 'INst'10 Press– it should display 'COnt'11 Pressthree times – it should display 'CLr'12 Pressonce to clear any previous binding data13 Press– it should display 'COnt'14 Pressonce to send the bindingsignal to the evohome Controller9 ou should receive a SUCCESS message on theYevohome Controller. If not, go back and re-bind.

evohome Controller (ATC928G2000)evohome Controller(ATC928G2000)Mixing Valve Controller(HM80)To bind a Mixing Valve Controller (HM80) to an evohomeController (ATC928G2000) “mixing valve” zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE SETTINGS4 Press EDIT ZONE5 Press on the required zone6 Press the button next to “Application:”7 Press MIXING VALVE1On the Mixing Valve Controller8 Press and hold both buttons on theMixing Valve Controller for 4 secondsuntil the red light flashesOn the evohome Controller9 Press the bind button ou should receive a SUCCESS message on theYevohome Controller. If not go back and re-bind.The Mixing Valve Controller will not providea heat demand to the boiler. If you want thiszone to provide a heat demand change theApplication Type from 'MIXING VALVE' to 'ZONEVALVES' once the Mixing Valve controller isbound. There is no need to re-bind any device– The Mixing Valve Controller will still operateas intended and the evohome Controllerwill send the heat demand to the boiler.23

Wireless connectivity Guideevohome Controller(ATC928G2000)Radiator Controller(HR92)To bind a Radiator Controller (HR92) to an evohomeController (ATC928G2000) “radiator valve” zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE SETTINGS4 Press EDIT ZONE5 Press on the required zone6 Press the button next to “Application:”7 Press RADIATOR VALVE1On the Radiator Controller8 Press the button once itshould display UNBOUND24 Press and hold the button for a further5 seconds until it displays BIND10 Press thebutton once – itshould display BINDING9On the evohome Controller11 Pressthe bind button ou should receive a SUCCESS message onYboth the evohome Controller and the RadiatorController. If not go back and re-bind.

evohome Controller (ATC928G2000)evohome Controller(ATC928G2000)Radiator Controller(HR80)To bind a Radiator Controller (HR80) to an evohomeController (ATC928G2000) “radiator valve” zone.On the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press ZONE SETTINGS4 Press EDIT ZONE5 Press on the required zone6 Press the button next to “Application:”7 Press RADIATOR VALVE1On the Radiator Controller8 Press the recessed bind button on theunderside of the Radiator Controller – it shouldbriefly show a flashing RF icon then SYNC.9 Press the recessed bind button again – itshould show a flashing RF iconOn the evohome Controller10 Pressthe bind buttonThe evohome Controller will not show a SUCCESSmessage. It’s recommended to perform aquick functional check to validate the bind.To do this, adjust the setpoint temperature onthe evohome controller for that zone to themaximum and minimum, checking the radiatorcontroller responds to the new setpoint.25

Wireless connectivity Guideevohome Controller(ATC928G2000)Remote AccessGateway (RFG100)To bind a Remote Access Gateway (RFG100) to an evohome Controller (ATC928G2000).On the evohome ControllerOn the evohome Controller Press and hold SETTINGS for 5 seconds2 Press the green tick3 Press SYSTEM DEVICES4 Press the button next to “Remote Gateway:”5 Press REMOTE GATEWAYYou should receive a SUCCESS messageon the evohome Controller and the LED onthe Remote Access Gateway should turnsolid green. If not go back and re-bind.On the Remote Access GatewayRegister the Remote Access Gateway16 Press and hold the bind button on the base untilyou see a flashing green light next to the icon2678 Press the bind button Go to mytotalconnectcomfort.com toregister the Remote Access

6 Wireless connectivity Guide To bind a Digital Room Thermostat (DTS92) to a Wi-Fi evohome Controller (ATC928G3000) as the room temperature sensor in a zone. On the evohome Controller 1 Press and hold SETTINGS for 5 seconds 2 Press the green tick 3 Perss ZONE CONFIGURATION 4 Press on the required zone 5 Perss TEMPER

Related Documents:

Honeywell Honeywell All models that begin with T8000 Honeywell Honeywell All models that begin with T8001 Honeywell Honeywell All models that begin with T8002 Honeywell Honeywell All models that begin with T8011 Honeywell Honeywell All models that begin with T8024 Hon

honeywell new products 2 honeywell culture of safety 4 north eye & face protection 14 fibre-metal welding protection 214 * learn more about enabled safety products on page 6. honeywell emergency eyewash 44 honeywell laser safety products 56 honeywell vision screeners 64 howard leight hearing protection 66 honeywell & north respiratory protection 92 honeywell & north hand & arm protection 124

Honeywell Belgium EMEA Automation College Email: HPS-Training-Belgium@honeywell.com Honeywell Europe S.A. Tel: 32 (0)2 728 2589 Hermes Plaza Hermeslaan 1H 1831 Diegem (Brussels) Honeywell Finland Automation College Varkaus Email: HPS-Training-Finland@honeywell.com Honeywell Oy Tel: 358 (0)20 752 2275 Navitas 1, Block B, 2nd floor Wredenkatu 2 .

Honeywell 2/22/2011 Rev3 For Questions: ACSSupplierPortal@Honeywell.com 3 Honeywell Portal Content Choose a Tab to take you to your destination: Home - Always the first page you see - Announcements from Honeywell Purchase Order Management - Process PO‟s from Honeywell Performance & Reports - Current reports listed (future home of all reports)

1 Honeywell Home T4R Wireless Programmable Thermostat 2 Menu & Navigation Icons 3 Menu 3.1 Schedule Override 3.2 Changing the Batteries (T4 & T4R only) 3.3 Wireless Receiver Box (T4R only) 4 Troubleshooting 5 DOWNLOAD RESOURCES 6 FAQ'S 7 VIDEO 8 Documents / Resources 8.1 References 9 Related Posts Honeywell Home T4R Wireless Programmable .

2014 G650 . A V I O N I C S: Area NAV. Equipment Manufacture Model Quantity ADF Receiver Honeywell DF855 1 Honeywell NV-878A 2 Area NAV Honeywell NC-860A 1 ATC Transponder Honeywell XS-858B 2 DME Interrogator Honeywell DM855 2 Fixed Emergency Locator ARTEX C-406-N 1 Global Positioning System Honeywell NV878A 2

2014 G650 . A V I O N I C S: Area NAV. Equipment Manufacture Model Quantity ADF Receiver Honeywell DF855 1 Honeywell NV-878A 2 Area NAV Honeywell NC-860A 1 ATC Transponder Honeywell XS-858B 2 DME Interrogator Honeywell DM855 2 Fixed Emergency Locator ARTEX C-406-N 1 Global Positioning System Honeywell NV878A 2

Manual lever 5 Wire removable head DT90E1012 Digital display 1,2 or 3 On/Off Periods Frost protection 7 day programming Honeywell 22mm Zone Valve Honeywell Wired Thermostat Honeywell Programmable Thermostat Honeywell 22mm Y Plan Valve Honeywell Digital Thermostat Honeywell Wire