Fire DetectionProduct CatalogueAustraliaIssue 4.2

MAPNET II, SAFELINC, SIMPLEX, TRUEALARM are trademarks of Tyco Fire & Security GmbH or its affiliates. MINERVA, MX TECHNOLOGY aretrademarks of Thorn Security Limited. TYCO is a trademark of Tyco International Services GmbH. VIGILANT is a trademark of Tyco Australia PtyLimited. ECO, ICAM, LaserCOMPACT, LaserFOCUS, LaserPLUS, LaserSCANNER, OSID, VESDA and XTRALIS are trademarks of Xtralis TechnologiesLtd. WINDOWS is a registered trademark of Microsoft Corporation in the United States and other countries. Tyco Australia Pty Limited 2014. A.B.N. 80008399004. Unauthorised use of trademarks is strictly prohibited.First Printed June 2013. Reprinted 3 July mPage ii

Fire Detection Product CatalogueIntroductionWelcome to this fourth edition of the Tyco Fire Protection Products Australia Fire Detection Product Catalogue.We aim to make our product range as comprehensive as possible to ensure you never need go anywhere else. To meet this goal, ourproduct specialists, with your help, have selected the most appropriate, cost effective product range all available for next day deliveryfrom our National Distribution Centre. Only those products that meet the highest quality criteria have been included.Our warehouse, located in Melbourne, is one of the largest Fire & Security product distribution centres in Australia. Our goal is todespatch product on the same day as we receive your order when it is received before 1:00 pm. Our warranty and service returnspolicy is located towards the back of this catalogue on page “Warranty Procedure” on page 122 for your reference.We recognise that your business is highly dependant on excellence in customer service and to help achieve this we offer as standard,24 months warranty on Tyco Manufactured products. A purchase order and Return Authorisation (contact Customer Service) isrequired for parts to be replaced under warranty.For all enquiries regarding this catalogue, please contactTyco Fire Protection Products Customer ServiceTelephone:1300 725 688Facsimile:1300 720 733Email:tfppcustservice.au@tycofp.comFor Technical Support, please contactTyco Fire Protection Products Technical ServicesTelephone:1300 552 559www.tycofireprotectionproducts–anz.comPage 1

Fire Detection Product Catalogue5VIGILANT Non-AddressableFire ies 130AddressableModulesFire40 SIMPLEX Indicator PanelsTycoNon-AddressableDetector BasesHigh46 SIMPLEXLevel Interface10 Non-AddressableManual Call Points1216MX AddressableDetectorsAddressable21 MXModules25 VIGILANTRespondersPage 251MAPNET II /IDNetAddressableDevices56DetectorAccessories andRemote IndicatorsVIGILANTAddressable FireIndicator PanelsFunctional20 MXDetector Bases3649TrueAlarm AddressableDetectorsSeries 130AddressableDetectors58 AncillariesFire Panel62VIGILANT19in RackCabinets66 Looms and Cableswww.tycofireprotectionproducts–anz.com

Fire Detection Product Catalogue69AS1668 Controland Gas ControlWarning Systems86 — Audio Devices71 AnnunciatorsVIGILANT Remote72 CCU Networking75 Marine Fire Panels76 EWIS Panel90 IndicatorsAudio VisualSupply91 PowerUnitsBatteries and93 AccessoriesDoor Holders andVIGILANT QE9077 and Spares95VESDA Aspirating SmokeDetectorsEWIS AncillariesHazard100 SpecialDetectionFlame &82 GeneratorsWarning System10684 — Visual DevicesBeam Smoke& Linear HeatDetectionWarning SystemsDetector Test110 age 3

Fire Detection Product CatalogueTable of 14116117117118122123124127128Page 4Conventional (Non-Addresable) Fire Indicator PanelsConventional (Non-Addressable) Detectors - Tyco 614 SeriesConventional (Non Addressable) Detector BasesConventional (Non-Addressable) Manual Call PointsAddressable Fire Indicator PanelsMX TECHNOLOGY Analogue Addressable DetectorsFunctional Detector BasesMX TECHNOLOGY Analogue Addressable ModulesMX4428 RespondersAnalogue Addressable 130 Series DetectorsAnalogue Addressable 130 Series ModulesSIMPLEX 4100 System OverviewTrueAlarm IDNetSIMPLEX High Level InterfaceSIMPLEX 4100 Network SystemsTrueAlarm Addressable DetectorsSIMPLEX Addressable MAPNET II ModulesSIMPLEX Addressable MAPNET II/IDNet ModulesSIMPLEX Addressable IDNet ModulesDetector Accessories & Remote IndicatorsFire Panel AncillariesVIGILANT 19inch Rack Cabinet RangeLooms and CablesAS1668 Controls and Gas ControlsVIGILANT Remote AnnunciatorsCCU NetworkingConventional Marine PanelsWarning SystemsQE90 Ancillaries & SparesWarning System GeneratorsWarning System AncillariesAudio Visual Indicators (AVI)Batteries and Power SuppliesDoor Holders & AccessoriesAspirating Smoke Detectors VESDA Flame and Special Hazard DetectorsIntrinsically Safe - MX Analogue Addressable DetectorsIntrinsically Safe - Conventional (Non-Addressable) DetectorsIntrinsically Safe Isolators/BarriersBeam Smoke and Linear Heat DetectorsDetector Test EquipmentHazardous Area ClassificationInternational Protection RatingsSymbolsConventional (non-addresable) Detector Selection ChartMX Detector Selection ChartTyco/Minerva Sounder Base Selection GuideSpare Parts ListWarranty ProcedureQE90 EWIS Panel Configuration SheetIndexProduct IndexTerms and Conditionswww.tycofireprotectionproducts–anz.com

Fire Detection Product CatalogueConventional (Non-Addresable) Fire Indicator PanelsF3200 8 ZoneF3200 8 - 64 ZoneThe 8 zone F3200 will suit small installations requiring a system up to 8detection circuits and provides all the features of the existing F3200 FireIndicator Panel (FIP) range.The F3200 is a self-contained, modular, microprocessor based FIP whichperforms the functions of the CIE as specified by AS 4428. It has a high degree offlexibility and expandability, catering for medium to very large buildings.This panel is a replacement for the F08 FIP. It is a compact, self-contained panelwhich performs the functions of the Control and Indicating Equipment (CIE), asspecified by the Australian Standard AS 4428.1 Fire Detection, Control andIntercom Systems - Control and Indicating Equipment.A single panel has 8 zones fitted as standard, and can have up to 64 zones. Anetwork system may have up to 64 panels. The F3200 can be fitted with 64zone LEDs and supports AS 1668 fan controls and gas release.The 8 zone F3200 offers features including: -The F3200 detector circuit electronics caters for a wide range of detectors, Italso caters for interfacing to Intrinsically safe circuit barriers/isolators (hazardousareas), long line circuits e.g. from a sub-indicator FIP and tamper-proof circuits.Typically the 15U cabinet has space to accommodate up to 40Ah batterycapacity. The ActivFire Listings are: afp-789 (Tyco), afp-1421 (Simplex). AS4428 Firefighter Facility LCD Display Flexible programmable logic equations Event logging to history file Networking capabilities Eight zones fitted Standard 3A Power Supply to power a T-GEN 50 Battery capacity 2x17AhPart NumbersOperation is straightforward with the F3200’s keypad and alphanumericLCD. The 40 character, 2 line LCD zone control panel meets the AS 4428.1“Firefighter Facility” (FF) requirements. “Next” and “Prev” keys allow easy scrollingthrough the 99 event alarm buffer, while all current alarms, faults and isolatedzones can be separately displayed.ActivFire Listed: afp-789Remote Annunciators, refer to Page 71Part NumbersPanel:FP0784ManualsLT0250LT0255LT02568 zones fitted (max.) 3A PSU, 8U Cabinet(batteries not included)F3200 Operator’s ManualF3200 Installation andConfiguration ManualF3200 Programming ManualPhysicalCabinet Dimensions (HWD)FP0780 15U - 750 x 550 x 211 mmWeight 25kgFP0784 8U - 440 x 550 x 211 mmWeight 17kgIP Rating T0274KT0429KT0469ME04578 zones fitted 24 zone capacity, no cardframe 3A PSU, 15U Cabinet8 zones fitted 64 zone capacity, incl. cardframe 3A PSU, 15U Cabinet8 zones fitted 24 zone capacity, no cardframe 6A PSU, 15U Cabinet8 zones fitted 64 zone capacity, incl. cardframe 6A PSU, 15U CabinetF3200 Operator’s ManualF3200 Technical ManualF3200 Installation & Configuration ManualF3200 Programming ManualF3200 Presentation Drawings (AutoCAD)F3200 Architect’s Specification A48 zone input expansion kit (incl.PA0492, LM0053, 8xEOLR)8 relay expansion kit (incl. PA0493, LM0053, 8x MiniJump Links)Network upgrade kit (AS4428) {incl. IC0358,SF0222,LT0330,PA0773,LM0091}3A to 6A PSU Upgrade Kit (AS1603)3A to 6A PSU Upgrade Kit (AS4428)MX1 style Display Extender Kit (incl. FP1002, LM0291, LM0339)FP0475 Disp. Extender Kit incl 1.2m FRC. Use as first (LHS) Display.3U WA/Cube ASE Bracket & LoomDisplay Extender kit (incl PA0454, LM0046 0.5m FRC, not for 1st disp.)Cardframe upgrade kit3U Centaur ASE BracketF3200 AS1603 to AS4428 U/G Kit (incl.ME0098,LM0092,SF0423)F3200/NDU Upgrade to V5.xx SoftwareStick-on 3U A5 Document Holder (20 deep) for 15U cabinetsMX1 style 4U Display Door, 5x16 Zone, requires FP1002LED Displays - Refer to Page 59Spares - Refer to Page 118Part NumbersBlank Panels - (includes 19” rack fixing 5FZ90167U Blank Hinged Inner Door (312mm)6U Blank Panel Acrylic (267mm)4U Blank Panel (178mm)3U Blank Panel (134mm)2U Blank Panel (89mm)1U Blank Panel (45mm)5U Blank Panel (223mm)6U Blank Panel (267mm)Cabinets - Refer to Page 62www.tycofireprotectionproducts–anz.comPage 5

Fire Detection Product CatalogueF3200 Single Zone Gas Control PanelThe F3200 Single Zone (single risk) Gas ControlPanel is designed to meet the CIE requirements ofAS 4214-2002, “Gaseous Fire ExtinguishingSystems”. It includes all circuits and relays normallyrequired for single zone gas control panels. Whencoupled with the AVI Mk2 warning signs andFP0570/2 Local Gas Control Stations it providesa cost-effective, easily programmed single zonegaseous fire extinguishing system.SpecificationsDimensionsFP08768U - 440 x 550 x 211mm (HWD)15U - 750 x 550 x 211mm (HWD)FP0877Part NumbersFP0876F3200 AS4428 8U, 3A PSU,1U Gas Ctrl, Pre Prog. (shown at left)FP0877F3200 AS4428 15U, 6A PSU1U Gas Ctrl Pre Prog.FP0876 is an F3200 in an 8U cabinet (FP0784)complete with an ME0442 1 zone, 1U gas controlmodule pre-wired to the 8 zone module and an 8relay module.FP0877 is based on a 6 Amp power supply F3200assembled into the standard 15U cabinet (FP0782).It comes complete with an ME0442 1 zone, 1U gascontrol module pre-wired to the 8 zone module andan 8 relay module.FP0876 8U Panel with 3A PSUGas Control Stations - refer to page 70Warning Signs - refer to page 90F3200 Expansion KitsFP0553, F3200 8 Zone Input Expansion KitIncludes: PA0492, 8 Zone Module, LM0053 FRC, 8x EOLR (std). (EOL 2k7 5% 0.4W).FP0554, F3200 8 Relay Expansion KitIncludes: PA0493 8 Relay Module, LM0053 FRC, 8x Minijump links (for supervision selection).Part NumbersKT0072F3200 Cardframe Upgrade Kit(see below)FP0553F3200 8 Zone Input Expansion KitFP0554F3200 8 Relay Expansion KitF3200 AS1603.4 PSU Upgrade KitFP07493A to 6AFP0779F3200 AS 4428.1 PSUUpgrade Kit 3A to 6AF3200 AS4428 MAF/PSU 3APA08731931-3-3PA0874F3200 AS4428 MAF/PSU 6A1931-3-3KT0072 F3200 Cardframe Upgrade KitA KT0072 Cardframe upgrade kit can be fitted to a15U F3200 to allow it to take more than three 8 waymodules. The KT0072 cardframe can accommodate8 F3200 modules (for MX4428:- 8 ADR or 6 MPR/MXP/ADR RRM). In older versions, the cardframemounts directly to the rear of the cabinet. In newerversions, the cardframe is fitted to a gear plate thatmay be removed when the cabinet is mounted tothe wall.Part NumbersKT0072F3200 Cardframe Upgrade KitF3200 SparesPA0874, F3200 AS4428 MAF/PSU 6A 1931-3-3PA0873, F3200 AS4428 MAF/PSU 3A 1931-3-3For a comprehensive list of spares, refer to page 118Page 6www.tycofireprotectionproducts–anz.com

Fire Detection Product CatalogueConventional (Non-Addressable) Detectors - Tyco 614 SeriesThe Tyco 614 range of low profile non-addressabledetectors have a number of unique design featuresthat offer improved operation, installation and easeof servicing. Through innovative design, thesedetectors have reduced the installation and servicingtime to a minimum.The Tyco 614 range includes the 614CH CarbonMonoxide fire detector, which responds tocarbonaceous fires with an unprecedented earlydetection of slow smouldering fires, yet offersunequalled false alarm immunity.The use of the patented optical sensing chamber,together with refined signal processing, has enabledthe introduction of a smoke detector suitable forfast, reliable smoke detection of both slow and fastdeveloping fires.The Tyco 614 series is compatible with VIGILANTand Simplex CIE collective (non-addressable) circuits.Features Range includes unique CO Heat fire detector Type A, B, C and D Heat detector Low profile and discreet Superior performance and reliability Patented optical chamber Attractive design Designed for fast, easy installation Detector Lock included with 5B base Integral and remote alarm LED ActivFire and FPANZ Listing614CH Carbon Monoxide and Heat Fire DetectorThe 614CH fire detector provides very early warningof slow smouldering fires. The CO fire detectoris well suited to many applications where heatdetection is insufficient but smoke detection causesunwanted alarms. As CO travels more freely thansmoke, the positioning of CO fire detectors is moreflexible. This feature is particularly useful in largecomplex structures such as atria and warehouses,where positioning of smoke detectors is difficult.The 614CH has an additional mode of operationas a Class A1R combined rate-of-rise and 60 Cfixed temperature heat detector to supplementthe CO detector mode to permit the detector toreact to a wider range of fire types. Although the614CH has a rated service life of 10 years, in orderfor the 614CH to provide the intended level offire detection, the detector should be checked forcalibration 5 years after installation (or 5 years afterre-installation following service) or within 7 years ofthe date of manufacture.SpecificationsOperating VoltageQuiescent CurrentAlarm Current1Alarm State VoltageAlarm ThresholdExt. Powered Load (max.)Remote IndicatorRelative HumidityAmbient TempDimensions (incl. base)WeightActivFire ListedFPANZ ListedPart Number10 to 33Vdc55µA (max.)3.2 to 67mA (50 C)2.5 to 7.4Vdc38ppm CO50mA, 28VdcE500 Mk2 Series15 to 90% (n/cond)0 to 50 C127 dia x 54H (mm)200g with baseafp-1718VF/345516.600.3041. 3.2mA min. for LED visibility. Max. current must be externallylimited614P Photoelectric Smoke DetectorThe 614P is capable of detecting the visible smokeproduced by materials which smoulder or burnslowly, i.e. soft furnishings, plastic foam etc. or‘smoke’ produced by overheated but unburnt PVC.These detectors are particularly suitable for generalapplications and areas where cable overheatingmay occur; electrical services areas. The noveldesign of the asymmetrical sampling chamber andsignal processing techniques stop unwanted alarmscaused by very small insects. Smoke entering thesampling chamber scatters the infrared light pulsesonto a photodiode. These pulses are converted toan electrical signal that is compared against a presetalarm level.SpecificationsOperating VoltageQuiescent CurrentAlarm Current (max.)*Alarm State VoltageExt. Powered Load (max.)Sensitivity (AS7240.7-2004)Remote IndicatorRelative HumidityAmbient TemperatureDimensions (incl. base)WeightActivFire ListedFPANZ ListedPart Number10 to 33Vdc60µA0.7 to 67mA (55 C)0.7 to 60mA (70 C)2.5 to 7.4V50mA. 28Vdc4%Obs/mE500 Mk2 Series10% to 95% (n/cond)-20 C to 70 C127 dia x 54H (mm)188g with baseafp-1715VF/344516.600.301*Max. current must be externally limited614I Ion Chamber Smoke DetectorThe 614I detectors are offered for legacyspecifications which still call for ionisation smokedetectors. The 614I offers detection of visible andinvisible fire aerosols (products of combustion) andis therefore capable of detecting the early presenceof hot smouldering and flaming fires, such as wood,paper etc. They use a dual ionisation chamberin which the air is ionised by a single radioactivesource. The presence of smoke in the samplingchamber causes a change in the balance voltagebetween the two chambers. This is then comparedagainst an alarm level.Use of ionisation chamber smoke detectors isnot recommended for new installations.SpecificationsOperating VoltageQuiescent CurrentAlarm Current*Alarm State VoltageExt. Powered Load (max.)Ionisation SourceAlarm ThresholdRemote IndicatorRelative HumidityAmbient TemperatureDimensions (incl. base)WeightActivFire ListedFPANZ ListedPart Number12 to 33Vdc70µA0.7 to 67mA (55 C)0.7 to 60mA (70 C)2.5 to 7.4V50mA, 28Vdc 33kBq (Am241)0.32 MIC XE500 Mk2 Series10% to 95% (n/cond)-20 C to 70 C127 dia x 54H (mm)200g with baseafp-1716VF/343516.600.305*3.2mA min. for LED visibility. Max. current must be externally e 7

Fire Detection Product CatalogueConventional (Non-Addressable) Detectors - Tyco 614 Series614T Heat DetectorTyco 614T heat detectors use a fast response,thermistor based design. The fixed temperaturesensing thermistor readily tracks the local ambienttemperature, thus quickly, accurately and consistentlyidentifying when a fixed temperature is exceeded.Rate-of-rise detection is achieved by comparingthe response of two thermistors, with one having aslower thermal response. By combining accuratethermistors with proper physical placement, thispatented rate-of-rise detection design achieves a highlevel of heat detection performance.Part Model614TA614TB614TC614TDTypeType AType BType CType ecificationsOperating VoltageQuiescent Current 1Alarm Current 2Alarm State Voltage 3Remote IndicatorRelative HumidityAmbient TemperatureTypes A, BTypes C, DStorage TemperatureDimensions (mm)Weight11 to 32Vdc85µA @ 24Vdc (typ.)5mA to 80mA3.0V to 12.4VE500 Mk2 Series10% to 95% (n/cond)-10 C to 45 C-10 C to 75 C-20 C to 75 C127 dia x 53H174g with 5B base1. Max. quiescent 110μA. 2. Min. 5mA for LED visibility; max.current must be externally limited. 3. Min. voltage with remoteindicator shorted @ 5mA. Max @ 80mA without remote indicatorconnected.885WP-B IP67 Heat DetectorThe 885WP-B is a 2 wire fixed temperature Type Bheat detector. This detector is designed to provideopen area protection in areas subject to moisture. Itis sealed against the entry of moisture to a rating ofIP67. The LED will latch on when the detector is inalarm. Detectors are used with a mounting base thatpermits mounting directly on to a 50mm or 60mmjunction box. The 885WP-B includes a tamperresistant feature that prevents its removal from themounting base without the use of a key. Flying leadsare provided for termination:- 2 Black (negative), 2Red (positive), 2 White (positive Remote LED).SpecificationsOperating VoltageQuiescent CurrentAlarm Current (min.)Alarm Current (max.)Max. Air VelocityAlarm TemperatureAmbient TemperatureDimensions (mm)WeightIngress ProtectionActivFire ListingPart NumberThe D515B Duct Sampling Unit consists of aD51B duct housing fitted with a 5B base suitablefor fitting a non-addressable 614P photoelectricsmoke detector. The D51B is designed to sampleair in air conditioning ducts and pass the air throughthe smoke detector. The housing is fixed on theoutside of the duct to be sampled, allowing easyaccess for detector servicing and replacement of thedust filter. To cater for most duct sizes, a samplingtube extension is available in 3 metre lengths. TycoE500 Mk2 Series Remote Indicators can be usedfor remote indication of an alarm. The D515B with614P can be used with F3200 CIE logic for nonlatching operation. The D515B with Tyco 614P iscompatible with non-addresable alarm zone circu

Operation is straightforward with the F3200’s keypad and alphanumeric LCD. The 40 character, 2 line LCD zone control panel meets the AS 4428.1 “Firefighter Facility” (FF) requirements. “Next” and “Prev” keys allow easy scrolling through the 99 event al

Related Documents:

Fire Detection Product Catalogue - New Zealand www.vigilant-fire.com.au . SIGMA 5 complies with NZS 4512:2010 "Fire Detection and Alarm Systems in Buildings" and meets the NZ Fire Service requriements for connection to remote receiving stations. FPANZ listing number VF/116. 6

FIRE TOPPER Fire Bowl User Manual Home » FIRE TOPPER » FIRE TOPPER Fire Bowl User Manual Contents [ hide 1 FIRE TOPPER Fire Bowl 2 Setting Up Your Fire Topper Fire Bowl 2.1 Set-Up 3 Placement and Location 3.1 Liquid Propane Tank 4 Using your Fire Topper Fire Bowl - For your safety, read before lighting. 5 Cleaning, Maintenance, Storage 6 .

comply with particularly stringent fire detection demands. Smouldering fires Open flames/ exponential development Fully developed fire Very early fire detection (High sensitivity) EN 54-20, Class A Early fire detection (increased sensitivity) EN 54-20, Class B Normal fire detection (normal sensitivity) EN 54-20, Class C/ EN 54-7

ZETTLER, is a leading brand of fire detection, security, and care communications products in the European market. The ZETTLER fire detection product line includes a wide range MZX TECHNOLOGY EN54 CPR approved fire detection products carrying approvals and cross-listings, including VdS and NF, for all European countries.

fire detection protection systems scope limited to equipments and does not cover disaster management physical evacuation etc . fire detection and protection: intro fire detection system smoke detectors fire alarm panel hooters mcp fire protection system water storage pump house hydrant line hydrant valves hose reels

social or cultural context (livelihoods, festivals, traditional, conflict) and perhaps regulatory framework (permit fires, illegal fires). The terms include fires, wildfires, wildland fire, forest fire, grass fire, scrub fire, brush fire, bush fire, veldt fire, rural fire, vegetation fire and so on (IUFRO 2018). The European Forest Fire

Fire Detection and Alarm Systems A key aspect of fire protection is to identify a developing fire emergency in a timely manner, and to alert the building's occupants and fire emergency organizations. This is the role of fire detection and alarm systems. Depending on the anticipated fire scenario, building and use type, number

2.7 UL - 268 UL Standard for Safety Smoke Detectors for Fire Alarm Systems 2.8 EN 54/22 Fire detection and fire alarm systems. Resettable line‐type heat detectors 2.9 EN 54/20 Fire detection and fire alarm systems. Aspirating Smoke detectors 2.10 IS 15519:2004 Water Mist Fire Protection Systems-System Design, Installation