780 CMR 3.00 USE AND OCCUPANCY CLASSIFICATION

2y ago
30 Views
2 Downloads
1,005.10 KB
20 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Camille Dion
Transcription

780 CMR 3.00USE AND OCCUPANCY CLASSIFICATION780 CMR 301.0 GENERAL301.1 Scope. The provisions of 780 CMR 3.00shall control the classification of all buildings andstructures as to use and occupancy.301.1.1 The ICC International Fire Code (IFC),the ICC International Mechanical Code (IMC)and the Specific Specialized Code - The Board ofFire Prevention Regulations (527 CMR).780 CMR contains design and constructionrequirements for all USE Group buildings andtheir building permittable systems and alsoreferences additional applicable design andconstruction requirements of the IFC and the IMCfor the various USE Groups and industrialprocesses within such USE Groups, including HUSES. It is the intention in referencing the IFCand the IMC that only the IFC and IMCrequirements narrow to Building Code matters;i.e., USE Group classification, general buildinglimitations of height and area, fireresistantmaterials and construction, interior finishes,required fire protection systems (otherwise notspecifically regulated by 527 CMR), means ofegress, interior environment, energy conservation,exterior wall coverings, roof and roof coverings,structural loads, structural tests and inspections,foundations and retaining walls, constructionmaterials, glass and glazing, plastics, mechanicalsystems, special construction, site work,demolition and construction in the public right-ofway, building permittable work in existingbuildings and control of manufactured buildingsand manufactured components, etc., ashistorically addressed in the Massachusetts StateBuilding Code are regulated by 780 CMR.Exception: The design and constructionrequirements of bunkers and magazines for thestorage of explosive materials, flammable/combustible liquids and chemical processsafety, shall default to the specificrequirements of 527 CMR and are notenforceable by Building Officials but rather bythe Head of the Fire Department or his/herdesignee.Note that the IFC and the IMC are not onlybuilding and building permittable systemsdesign and construction documents but alsoinclude fire prevention requirements and thefire prevention requirements of the IFC andIMC are not requirements regulated by780 CMR nor enforceable by BuildingOfficials. For fire prevention requirements donot refer to the IFC or IMC but rather to TheMassachusetts Board of Fire Prevention8/22/08 (Effective 9/1/08)Regulations (527 CMR). If there is conflictbetween 780 CMR and 527 CMR, the morestringent standard shall apply.301.1.2 The ICC International Fire Code (IFC),the ICC International Mechanical Code (IMC)and the Family of Massachusetts SpecializedCodes (refer to 780 CMR, 101.5). 780 CMRcontains design and construction requirements forall USE Group buildings and their buildingpermittable systems and also referencesadditional applicable design and constructionrequirements of the IFC and the IMC for thevarious USE Groups and industrial processeswithin such USE Groups, including H-USES. It isthe intention in referencing the IFC and the IMCthat only the IFC and IMC requirements narrowto Building Code matters (see 780 CMR 301.1.1)are regulated by 780 CMR. Where the IFC andIMC reference requirements related to:architectural access; environmental protection;electrical; elevator; fire prevention (otherwise notspecifically regulated by 527 CMR); gas; orsanitary code requirements, such requirementsare not regulated by 780 CMR nor enforceable byBuilding Officials (Building Officials do enforcearchitectural access requirements set forth in521 CMR). For Specialized Code requirementsdo not refer to the IFC or IMC but rather to theappropriate Specialized Code requirements ofMassachusetts (refer to 780 CMR, 101.5).780 CMR 302.0 CLASSIFICATION302.1 General. Structures or portions of structuresshall be classified with respect to occupancy in oneor more of the groups listed below. Structures withmultiple uses shall be classified according to780 CMR 302.3. Where a structure is proposed fora purpose which is not specifically provided for in780 CMR, such structure shall be classified in thegroup which the occupancy most nearly resembles,according to the fire safety and relative hazardinvolved.1. Assembly (See 780 CMR 303.0): Groups A-1,A-2, A-3, A-4 and A-52. Business (See 780 CMR 304.0): Group B3. Educational (See 780 CMR 305.0): Group E4. Factory and Industrial (See 780 CMR 306.0):Groups F-1 and F-25. High Hazard (See 780 CMR 307.0): GroupsH-1, H-2, H-3, H-4 and H-56. Institutional (See 780 CMR 308.0): Groups I1, I-2, I-3 and I-47. Mercantile (See 780 CMR 309.0): Group M780 CMR - Seventh Edition45

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDSTHE MASSACHUSETTS STATE BUILDING CODE8. Residential (See 780 CMR 310.0): Groups R1, R-2, R-3 as applicable in 780 CMR 101.2, andR-49. Storage (See 780 CMR 311.0): Groups S-1and S-210. Utility and Miscellaneous (See 780 CMR312.0): Group U302.1.1 Incidental Use Areas. Spaces which areincidental to the main occupancy shall beseparated or protected, or both, in accordance withTable 302.1.1 or the building shall be classified asa mixed occupancy and comply with 780 CMR302.3. Areas that are incidental to the mainoccupancy shall be classified in accordance withthe main occupancy of the portion of the buildingin which the incidental use area is located.Exception: Incidental use areas within andserving a dwelling unit are not required tocomply with 780 CMR 302.0.302.1.1.1 Separation. Where Table 302.1.1requires a fire-resistance-rated separation, theincidental use area shall be separated from theremainder of the building with a fire barrier.Where Table 302.1.1 permits an automatic fireextinguishing system without a fire barrier, theincidental use area shall be separated byconstruction capable of resisting the passage ofsmoke. The partitions shall extend from thefloor to the underside of the fire-resistancerated floor/ceiling assembly or fire-resistancerated roof/ceiling assembly or to the undersideof the floor or roof deck above. Doors shall beself-closing or automatic-closing upondetection of smoke. Doors shall not have airtransfer openings and shall not be undercut inexcess of the clearance permitted in accordancewith NFPA 80.TABLE 302.1.1INCIDENTAL USE AREASROOM OR AREAFurnace room where any pieceof equipment is over 400,000Btu per hour inputRooms with any boiler over 15psi and 10 horsepowerSEPARATION a1 hour or provide automaticfire-extinguishing system1 hour or provide automaticfire-extinguishing system1 hour or provide automaticRefrigerant machinery roomssprinkler system2 hours; or 1 hour andParking garage (Section 406.2) p r o v id e auto matic fire extinguishing systemHydrogen cut-off rooms1 -h o u r fire b a r r ie r s a n dfloor/ceiling assemblies inGroup B, F, H, M , S and Uoccupancies. 2-hour firebarriers and floor/ceilingassemblies in Group A, E, Iand R occupancies.Incinerator rooms2 h o u rs a n d a u to m a t i csprinkler systemPaint shops, not classified as 2 hours; or 1 hour andG ro up H , located in p r o v i d eautomaticoccupancies other than Group fire-extinguishing systemFLaboratories and vocationalshops, not classified as GroupH, located in Group E or I-2occupanciesLaundry rooms over 100 squarefeetStorage rooms over 100 squarefeetGroup I-3 cells equipped withpadded surfacesGroup I-2 waste and linencollection roomsW aste and linen collectionrooms over 100 square feetStationary lead-acid batterysystem s having a liquidcapacity of more than 100gallons used for facilitystandby power, emergencypower or uninterrupted powersupplies1 hour or provide automaticfire-extinguishing system1 hour or provide automaticfire-extinguishing system1 hour or provide automaticfire-extinguishing system1 hour1 hour1 hour or provide automaticfire-extinguishing system1-hour fire barriers andfloor/ceiling assemblies inGroup B, F, H , M, S and Uoccupancies. 2-hour firebarriers and floor/ceilingassemblies in Group A, E, Iand R occupanciesFor SI: 1 square foot 0.0929 m2, 1 pound persquare inch 6.9 kPa, 1 British thermal unit perhour 0.293 watts, 1 horsepower 746 watts, 1gallon 3.785 L.a. Where an automatic fire-extinguishing system isprovided, it need only be provided in the incidentaluse room or area302.2 Accessory Use Areas. A fire barrier shall berequired to separate accessory use areas classified asGroup H in accordance with 780 CMR 302.3.2, andincidental use areas in accordance with 780 CMR302.1.1. Any other accessory use area shall not berequired to be separated by a fire barrier provided theaccessory use area occupies an area not more than10% of the area of the story in which it is locatedand does not exceed the tabular values in Table 503for the allowable height or area for such use.46780 CMR - Seventh Edition8/22/08 (Effective 9/1/08)

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDSUSE AND OCCUPANCY CLASSIFICATION302.2.1 Assembly Areas. Accessory assemblyareas are not considered separate occupancies ifthe floor area is equal to or less than 750 squarefeet (69.7 m2). Assembly areas that are accessoryto Group E are not considered separateoccupancies. Accessory religious educationalrooms and religious auditoriums with occupantloads of less than 100 are not considered separateoccupancies (also See 780 CMR 303.1 and303.1.1).302.3 Mixed Occupancies. Where a building isoccupied by two or more uses not included in thesame occupancy classification, the building orportion thereof shall comply with 780 CMR 302.3.1and/or 302.3.2.Exceptions:1. Occupancies separated in accordance with780 CMR 508.0.2.Areas of Group H-2, H-3, H-4 or H-5occupancies shall be separated from any otheroccupancy in accordance with 780 CMR 302.3.2.3. Where required by Table 415.3.2, areas ofGroup H-1, H-2 or H-3 occupancy shall be locatedin a separate and detached building or structure.4.Accessory use areas in accordance with780 CMR 302.2.5.Incidental use areas in accordance with780 CMR 302.1.1.302.3.1 Nonseparated Uses. Each portion of thebuilding shall be individually classified as to use.The required type of construction for the buildingshall be determined by applying the height andarea limitations for each of the applicableoccupancies to the entire building. The mostrestrictive type of construction, so determined,shall apply to the entire building. All other coderequirements shall apply to each portion of thebuilding based on the use of that space except that8/22/08 (Effective 9/1/08)the most restrictive applicable provisions of780 CMR 403.0 and 780 CMR 9.00 shall apply tothese nonseparated uses. Fire separations are notrequired between uses, except as required by otherprovisions.302.3.2 Separated Uses. Each portion of thebuilding shall be individually classified as to useand shall be completely separated from adjacentareas by fire barrier walls or horizontal assembliesor both having a fire-resistance rating determinedin accordance with Table 302.3.2 for uses beingseparated. Each fire area shall comply with780 CMR based on the use of that space. Eachfire area shall comply with the height limitationsbased on the use of that space and the type ofconstruction classification. In each story, thebuilding area shall be such that the sum of theratios of the floor area of each use divided by theallowable area for each use shall not exceed one.Exception: Except for Group H and I-2 areas,where the building is equipped throughout withan automatic sprinkler system, installed inaccordance with 780 CMR 903.3.1.1, the fireresistance ratings in Table 302.3.3 shall bereduced by one hour but to not less than 1 hourand to not less than that required for floorconstruction according to the type ofconstruction.302.4 Spaces Used for Different Purposes. Aroom or space that is intended to be occupied atdifferent times for different purposes shall complywith all the requirements that are applicable to eachof the purposes for which the room or space will beoccupied.780 CMR - Seventh Edition47

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDSTHE MASSACHUSETTS STATE BUILDING CODETABLE 302.3.2 REQUIRED SEPARATIONOF OCCUPANCIES (HOURS)48780 CMR - Seventh Edition8/22/08 (Effective 9/1/08)

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDSUSE AND OCCUPANCY CLASSIFICATION780 CMR 303.0 ASSEMBLY GROUP A303.1 Assembly Group A. Assembly Group Aoccupancy includes, among others, the use of abuilding or structure, or a portion thereof, for thegathering together of persons for purposes such ascivic, social or religious functions, recreation, foodor drink consumption or awaiting transportation. Aroom or space used for assembly purposes by lessthan 50 persons and accessory to another occupancyshall be included as a part of that occupancy.Assembly areas with less than 750 square feet (69.7m2) and which are accessory to another occupancyaccording to 780 CMR 302.2.1 are not assemblyoccupancies. Assembly occupancies which areaccessory to Group E in accordance with 780 CMR302.2 are not considered assembly occupancies.Religious educational rooms and religiousauditoriums which are accessory to churches inaccordance with 780 CMR 302.2 and which haveoccupant loads of less than 100 shall be classified asA-3.Assembly occupancies shall include the following:(1)A-1 Assembly uses, usually with fixedseating, intended for the production and viewingof the performing arts or motion picturesincluding, but not limited to:(a) Motion picture theaters(b) Symphony and concert halls(c) Television and radio studios admitting anaudience(d) Theaters(2) A-2 Assembly uses intended for food and/ordrink consumption shall be further categorizedas A-2r and A-2nc (where A-2nc is the AssemblyUSE designation narrow to night clubs and A-2ris the USE designation for A-2 USES other thannight clubs); A-2 USES include but are notlimited to:(a) Banquet halls(b) Night clubs(c) Restaurants(d) Taverns and barsNote: independent of the “A-2” USEClassification set forth in 780 CMR303.1(2), requirements associated withM.G.L. c. 148, § 26G.5, M.G.L. c. 148A,M.G.L. c. 143, § 97A – all such GeneralLaws related to St. 2004, c. 304 - couldultimately result in an A-2r USE beingreclassified as an A-2nc USE.(3) A-3 Assembly uses intended for worship,recreation or amusement and other assembly usesnot classified elsewhere in Group A including, butnot limited to:(a) Amusement arcades(b) Art galleries(c) Bowling alleys(d) Churches(e) Community halls(f) Courtrooms8/22/08 (Effective 9/1/08)(g) Dance halls (not including food or drinkconsumption)(h) Exhibition halls(i) Funeral parlors(j) Gymnasiums (without spectator seating)(k) Indoor swimming pools (without spectatorseating)(l) Indoor tennis courts (without spectatorseating)(m) Lecture halls(n) Libraries(o) Museums(p) Waiting areas in transportation terminals(q) Pool and billiard parlors(4) A-4 Assembly uses intended for viewing ofindoor sporting events and activities withspectator seating including, but not limited to:(a) Arenas(b) Skating rinks(c) Swimming pools(d) Tennis courts(5) A-5 Assembly uses intended for participationin or viewing outdoor activities including, but notlimited to:(a) Amusement park structures(b) Bleachers(c) Grandstands(d) Stadiums303.1.1 Nonaccessory Assembly Use.Abuilding or tenant space used for assemblypurposes by less than 50 persons shall beconsidered a Group B occupancy.780 CMR 304.0 BUSINESS GROUP B304.1 Business Group B. Business Group Boccupancy includes, among others, the use of abuilding or structure, or a portion thereof, for office,professional or service-type transactions, includingstorage of records and accounts.Businessoccupancies shall include, but not be limited to, thefollowing:(1) Airport traffic control towers(2) Animal hospitals, kennels and pounds(3) Banks(4) Barber and beauty shops(5) Car wash(6) Civic administration(7) Clinic—outpatient(8) Dry cleaning and laundries; pick-up anddelivery stations and self-service(9) Educational occupancies above the 12thgrade(10) Electronic data processing(11) Laboratories; testing and research(12) Motor vehicle showrooms(13) Post offices(14) Print shops(15) Professional services (architects, attorneys,dentists, physicians, engineers, etc.)780 CMR - Seventh Edition49

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDSTHE MASSACHUSETTS STATE BUILDING CODE(16) Radio and television stations(17) Telephone exchanges780 CMR 305.0 EDUCATIONAL GROUP E305.1 Educational Group E. Educational Group Eoccupancy includes, among others, the use of abuilding or structure, or a portion thereof, by six ormore persons at any one time for educationalpurposes through the 12th grade.Religiouseducational rooms and religious auditoriums, whichare accessory to churches in accordance with780 CMR 302.2 and have occupant loads of lessthan 100, shall be classified as A-3 occupancies.305.2 Day Care.In conjunction with theadditional applicable requirements of 780 CMR,422, the use of a building or structure, or portionthereof, for educational, supervision or personalcare services for children older than two years andnine months years of age, shall be classified as aGroup E occupancy (also see 780 CMR 308.5) –Note however, that the express Special Use andOccupancy requirements of 780 CMR 422.0, forDay care occupancies shall override the generalrequirements and limitations of E and I USE.780 CMR 306.0 FACTORY GROUP F306.1 Factory Industrial Group F. FactoryIndustrial Group F occupancy includes, amongothers, the use of a building or structure, or a portionthereof, for assembling, disassembling, fabricating,finishing, manufacturing, packaging, repair orprocessing operations that are not classified as aGroup H hazardous or Group S storage occupancy.306.2 Factory Industrial F-1 Moderate-HazardOccupancy. Factory industrial uses which are notclassified as Factory Industrial F-2 Low Hazard shallbe classified as F-1 Moderate Hazard and shallinclude, but not be limited to, the following:(1) Aircraft(2) Appliances(3) Athletic equipment(4) Automobiles and other motor vehicles(5) Bakeries(6) Beverages; over 12% alcohol content(7) Bicycles(8) Boats(9) Brooms or brushes(10) Business machines(11) Cameras and photo equipment(12) Canvas or similar fabric(13) Carpets and rugs (includes cleaning)(14) Clothing(15) Construction and agricultural machinery(16) Disinfectants(17) Dry cleaning and dyeing(18) Electric generation plants(19) Electronics(20) Engines (including rebuilding)(21) Food processing50(22) Furniture(23) Hemp products(24) Jute products(25) Laundries(26) Leather products(27) Machinery(28) Metals(29) Millwork (sash & door)(30) Motion pictures and television filming(without spectators)(31) Musical instruments(32) Optical goods(33) Paper mills or products(34) Photographic film(35) Plastic products(36) Printing or publishing(37) Recreational vehicles(38) Refuse incineration(39) Shoes(40) Soaps and detergents(41) Textiles(42) Tobacco(43) Trailers(44) Upholstering(45) Wood; distillation(46) Woodworking (cabinet)306.3 Factory Industrial F-2 Low-HazardOccupancy. Factory industrial uses that involve thefabrication or manufacturing of noncombustiblematerials which during finishing, packing orprocessing do not involve a significant fire hazardshall be classified as F-2 occupancies and shallinclude, but not be limited to, the following:(1) Beverages; up to and including 12% alcoholcontent(2) Brick and masonry(3) Ceramic products(4) Foundries(5) Glass products(6) Gypsum(7) Ice(8) Metal products (fabrication and assembly)780 CMR 307.0 HIGH-HAZARD GROUP H[F] 307.1 High-Hazard Group H. High-HazardGroup H occupancy includes, among others, the useof a building or structure, or a portion thereof, thatinvolves the manufacturing, processing, generationor storage of materials that constitute a physical orhealth hazard in quantities in excess of those foundin Tables 307.7(1) and 307.7(2) (See also definitionof “Control area”).[F] 307.2 Definitions. The following words andterms shall, for the purposes of 780 CMR 307.0 andas used elsewhere in 780 CMR, have the meaningsshown in 780 CMR 307.2.

Group B, F, H, M, S and U occupancies. 2-hour fire barriers and floor/ceiling assemblies in Group A, E, I and R occupanc ies For SI: 1 square foot 0.0929 m2, 1 pound per square inch 6.9 kPa, 1 British thermal unit per hour 0.293 watts, 1 horsepower 746 watts, 1 gallon 3.

Related Documents:

780 CMR 33.00 and NFPA-241 listed in 780 CMR 35.00 in order to safeguard against fires during construction, alterations and demolition of all buildings and structures regulated by 780 CMR. 901.7.2 Authority. In accordance with the requirements of 780 CMR 110.0 and 780

Contents iv Cisco IOS XR Command Modes Reference HSRP Interface Configuration Mode CMR-6 Interface Address Family Configuration Mode CMR-7 Interface Configuration Mode CMR-7 Interface Configuration Mode (Protocol Areas) CMR-8 Interface IGMP Configuration Mode CMR-8 Interface Management Configuration Mode CMR-8 Interface Mulitcasting Mode CMR-9 Interface PIM Configuration Mode CMR-9

314 CMR 5 10314 CMR 5.10 All groundwater is actual or potential source of potable waterpotable water Effluent limitations consistent with levels established in 310 CMR 22.00in 310 CMR 22.00 Eliminate 314 CMR 6.00 Any Class III in existence as of 3/20/09 can remainAny Class III in existence as of 3/20/09 can remain

Ahmed, Ahmed Edmonton 780-244-2995 CCFP Ahmed, Bilal Affan Edmonton 780-426-1121 DRAD Ahmed, Ghalib Edmonton 780-468-6409 CCFP Ahmed, Iftekhar Edmonton 780-440-2040 - Ahmed, Imran Edmonton 587-521-2022 - Ahmed, Khaled Masood Abdullah Calgary 403-460-5171 CCFP Ahmed, Maaz Edmonton 780-990-1820 - Ahmed, Moheddin St. Albert 780-569-5030 -

Americans (see 110 CMR 1.07), handicapped clients (see 110 CMR 1.08), and nondiscrimination (see 110 CMR 1.09). Failure to conform to such obligations shall be grounds for terminating any provider's contract. (4) All purchases of services by the Department are subject to the proposal review of the

3. Wind exposure. If more than one wind exposure is utilized, the wind exposures and applicable wind directions shall be indicated. 1603.1.5 Earthquake Design Data. The following information related to seismic loads shall be shown, regardless of whether seismic loads govern the lateral design of the buildin

to the AF&PA Span Tables for Joists and Rafters, or the AF&PA Maximum Span Calculator for Joists & Rafters. 5502.3.1 Sleeping Areas and Attic Joists. 780 CMR Table 5502.3.1(1) shall be utilized to determine the maximum allowable span of floor joists that support sleeping areas

780 CMR 780 CMR 7th Edition Introduced January 2007 Based on the 2003 IBC Section 907.2.12.3 addressed Fire Department Communication System –Hardwired Telephone handset two-way system –Exception: Fire Department Radio Systems Exception NFPA 72 NFPA