H07RN-F FLEXIBLE MAINS AND CONTROL CABLE BS EN

2y ago
25 Views
4 Downloads
457.02 KB
5 Pages
Last View : 2m ago
Last Download : 3m ago
Upload by : Hayden Brunner
Transcription

T: 01642 241133W: www.clevelandcable.comE: sales@clevelandcable.comH07RN-F FLEXIBLE MAINS AND CONTROL CABLE BS EN 50525-2-21APPLICATIONFlexible EPR cable with high resistance tomechanical stress. Able to withstand waterand weather. For use on Work sites, mobilepower supplies, ports and harbors, watertreatment plants, sewage and drains, hot andcold areas and harsh industrial environments.For use in portable power supplies, siteequipment, industrial machinery, and audiovisual equipment. Can be cut to size for patchleads with a choice of fittings.CONSTRUCTIONConductor: Class 5 flexible stranded copperconductor to BS EN 60228Insulation: EPR (Ethylene Propylene Rubber)to BS 50363Sheath: PCP (Polychloroprene)To BS EN 50363* 3 Core comes in choice of core colours.See Core Identification.CABLE STANDARDSBS EN 50525-2-21BS EN 60811-2-1BS EN/IEC 60332-1-2CHARACTERISTICSVoltage Rating: 450/750 VoltsTemperature Limits: Fixed: -25 C to 60 C,Can be supplied up to 90OCMinimum Bending Radius: As permanufacturer datasheetCORE IDENTIFICATION2 Core:*3 Core:*3 Core:4 Core:5 BlackGreyG/YGreyGreyCable with 6 core and aboveBlackwith White Numbers plusShould not be installed below 0OCCLEVELAND CABLE COMPANY DATASHEET 1G/YBlueG/Y

T: 01642 241133W: www.clevelandcable.comE: sales@clevelandcable.comH07RN-F FLEXIBLE MAINS AND CONTROL CABLE - DIMENSIONSCONDUCTOR SIZE(MM2)STRANDING(MM)NO OF CORES3182P132/0.202CCC CODEWEIGHT(KG/KM)OVERALL VELAND CABLE COMPANY DATASHEET 2

T: 01642 241133W: www.clevelandcable.comE: sales@clevelandcable.comH07RN-F FLEXIBLE MAINS AND CONTROL CABLE - DIMENSIONSCONDUCTOR SIZE(MM2)STRANDING(MM)NO OF 96/0.406384P2256385P256381P35CCC CODEWEIGHT(KG/KM)OVERALL 41.3526381P6306302257/0.601746045.556.5CLEVELAND CABLE COMPANY DATASHEET 3

T: 01642 241133W: www.clevelandcable.comE: sales@clevelandcable.comH07RN-F CURRENT – CARRYING CAPACITY (AMPERES)60oC CONDUCTOR OPERATING TEMPERATURECONDUCTOR CROSS– SECTIONAL AREAMM²SINGLE-PHASE AC OR DC*1MM – 2.5MM AC ONLY2 CORE CABLEWITH OR WITHOUTPROTECTIVECONDUCTOR2 SINGLE CORECABLES85oC CONDUCTOR OPERATING TEMPERATURETHREE-PHASE AC3, 4 OR 5CORE CABLESINGLE-PHASE AC OR DC2 CORECABLE WITHOR WITHOUTPROTECTIVECONDUCTOR2 SINGLE CORECABLES TOUCHINGTHREE-PHASE AC3, 4 OR 5CORE -1017-630-861--1190-THE ABOVE IS IN ACCORDANCE WITH 18TH EDITION OF IET WIRING REGULATIONSCLEVELAND CABLE COMPANY DATASHEET 4

T: 01642 241133W: www.clevelandcable.comE: sales@clevelandcable.comH07RN-F - VOLTAGE DROP2 X SINGLE CORE CABLES TOUCHINGNOMINAL CROSSSECTIONALAREAMM²2 CORECABLE DCmV/A/mTWO CORE CABLESINGLE-PHASE ACmV/A/m1 X THREE CORE, FOUR CORE OR FIVE CORECABLE, THREE PHASE AC146461.5322.519DCmV/A/mSINGLE PHASE AC 0790.170.185THE ABOVE IS IN ACCORDANCE WITH 18TH EDITION OF IET WIRING REGULATIONSCONDUCTOR OPERATING TEMPERATURE: 90 CR RESISTIVE COMPONENTX REACTIVE COMPONENTZ IMPEDANCE VALUE* A LARGER VOLTAGE DROP WILL RESULT IF THE CABLES ARE SPACED APARTTHE INFORMATION CONTAINED WITHIN THIS DATASHEET IS FOR GUIDANCE ONLY AND IS SUBJECT TO CHANGE WITHOUT NOTICE OR LIABILITY. WE BELIEVE THEINFORMATION IS CORRECT AT THE TIME OF PUBLICATION. PLEASE NOTE WHEN SELECTING CABLE ACCESSORIES THAT ACTUAL CABLE DIMENSIONS MAY VARYDUE TO MANUFACTURING TOLERANCES.CLEVELAND CABLE COMPANY DATASHEET 5

2 core cable dc mv/a/m two core cable single-phase ac mv/a/m 1 x three core, four core or five core cable, three phase ac 2 x single core cables touching dc mv/a/m single phase ac * mv/a/m 1 46 46 40 - - 1.5 32 32 27 - - 2.5 19 19 16 - - 4 12 12 10 - - 6 7.8 7.8 6.7 - - 10 4.6 4.6 4 - - 16 2.

Related Documents:

YEARLONG MAINS TEST SERIES 2020-2021 EARLONG MAINS Test series is a MAINS component of IPM program of INSIGHTSIAS targeted towards Coveted Civil services Examination that guarantees leaps and bounds of your progress. The Yearlong MAINS Test series consists of a total of 52 Tests.

4 ATS Control Panel Installation Guide !! 1. G ENERAL INSTALLATION INFORMATION 1. Mains Power connection Use the Mains Connector Terminal for connecting the mains-supply. A fixed cable or a flexible mains lead to an earthen mains outlet can be used. In case fixed wiring is used, insert a dedicated circuit breaker in the power distribution .

plug from the wall socket in case of emergency. The mains cable must be free and away from the bed frame. Otherwise, the mains cable may be torn out and damaged. In addition, the mains plug may be pulled out of its socket and electric leads exposed as a result. If the mains cable or the mains plug is damaged, the relevant part must be replaced.

YEARLONG MAINS TEST SERIES 2020-2021 EARLONG MAINS Test series is a MAINS component of IPM program of INSIGHTSIAS targeted towards Coveted Civil services Examination that guarantees leaps and bounds of your progress. The Yearlong MAINS Test series consists of a total of 52 Tests.

electric shock or fire. - Do NOT touch the mains lead or mains plug with wet hands. Possibility of an electric shock. - Do NOT pull the mains lead but hold the mains plug to unplug the appliance. Otherwise, there is possibility of damage to the mains lead, which may lead to an electric shock or fire. NA-140VG3_Australia.indb 4 2011-5-20 11:39:41

filtration systems, OASIS Mains-Fed Water Coolers provide healthy refreshing water. 1922: First mains-fed water cooler "bubbler" 1954: First Hot 'N Cold model is designed 1990: First mains-fed water cooler systems integrated with filters are marketed 2006: Kalix mains-fed water cooler model with PVDC system introduced

The Liebert PSI 750, 1000 and 1500 models are not supplied with an input power cable for connec-tion to the mains supply socket. Use the input mains supply power cable from your data processing equipment to connect the UPS to the mains supply. For the Liebert PSI 2200 and 3000 models, use the supplied 16A-rated input mains supply cables. For

API Structure Over 500 member companies involved in all aspects of the oil and natural gas industry Over 700 committees and task forces covering various advocacy and technical issues Staff of 240 led by board of directors who are the CEO’s of API member companies . API Standards Program All industry segments active in standardization: Exploration and Production Refining Petroleum .