Application GuideHeating ControlDanfoss Link & Connect Thermostatswww.heating.danfoss.com

Application GuideHeating Control with Danfoss Link & Connect ThermostatsTable of Contents1. Introduction1.1 Segment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.2 Danfoss Eco programmable radiator thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.3 Overview of units in a Danfoss Link system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.4 Number of units in a Danfoss Link system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5 Best Practice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .333442. General Guidelines2.1 Heat supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.2 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.3 Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83. Applications3.1 Heating system with Boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.2 Heating system with Central Boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.3 District Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.4 Heat Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2VAIDD402 Danfoss07/201611131415

Application Guide1.Heating Control with Danfoss Link & Connect ThermostatsIntroduction1.1 SegmentThis application guide covers the use of Danfoss Link , Danfoss Link Connect Thermostat wirelessheating controls and Danfoss Eco in 1 and 2 family houses and flats up to 300 m2.1.2 Danfoss Eco programmableradiator thermostatDanfoss Eco is a stand-alone intelligent and programmable radiator thermostat*for residential use, where a central control system is not availableIt is easy to install and is supplied with adapters for all thermostatic valves manufactured by Danfoss and most other radiator valve manufacturers.1.3 Overview of unitsin a Danfoss Link systemThe following units can be used in a Danfoss Link wireless system:Danfoss Link RS Room Sensoris used for measuring and adjusting the room temperature. Danfoss Link HC Hydronic Controllerallows control of hydronic floor heating witha large range of functions. 21,5 Danfoss Link Connect Thermostat is an electronic radiatorthermostat* for residential use,which is controlled by a DanfossLink CC. Danfoss Link CC CentralController is the unit, from whichthe entire installation can becontrolled. One Danfoss Link CCis always needed in a system. Danfoss Link BR Boiler Relayis a unit for turning gas and oilboilers ON/OFF, depending onheating demand.Danfoss Link FT Floor Thermostat is used for measuring andadjusting electrical floor heating.Danfoss Link RU RepeaterUnit is used for extending thewireless transmission rangebetween Danfoss Link CC andother units in a system.* Danfoss recommends using Connect and Eco Thermostats together with Danfoss radiator valves withintegrated pre-setting in order to achieve optimal performance.For choise of adaptor please use the Danfoss adaptor guide, which also includes adaptors for non Danfossvalves.VAIDD402 Danfoss07/20163

Application Guide1.4 Number of units in aDanfoss Link system1.5 Best practiceHeating Control with Danfoss Link & Connect ThermostatsWhen building a wireless Danfoss Link control system it is important to follow these rules:1. The total number of units must not exceed 50 (1 Danfoss Link Central Controller 49 units).2. The number of each type of unit must not exceed:Danfoss Link CC . . . . . . . . . . . . . . . . . . . . . . 1 unitConnect Thermostat . . . . . . . . . . . . . . . . . 30 unitsDanfoss Link HC . . . . . . . . . . . . . . . . . . . . . 3 unitsDanfoss Link RS . . . . . . . . . . . . . . . . . . . . 30 unitsDanfoss Link FT . . . . . . . . . . . . . . . . . . . . . 30 unitsDanfoss Link BR . . . . . . . . . . . . . . . . . . . . . . 1 unitDanfoss Link RU . . . . . . . . . . . . . . . . . . . . . 3 unitsMains powered unitsAvoid disconnecting mains powered units ina Danfoss Link system. In the event this happens the system will eventually re-establish thenetwork, when repeater unit is reconnected tothe mains power.230 VDanfoss Link RUDanfoss Link RU Repeater unitsIt is always recommended to use Danfoss Link RU, when a repeater is needed to extend the radiocommunication range. Several mains powered units (such as relays) also act as repeaters, but withlimited capability to improve the communication range compared to Danfoss Link RU.Danfoss Link RU repeaters should always be registered as the first 230 V units in the system.4VAIDD402 Danfoss07/2016

Application GuideHeating Control with Danfoss Link & Connect ThermostatsDanfoss Link RS Room SensorThe Danfoss Link RS is designed to measure theroom temperature and control the Connect Thermostats to reach the set room temperature.The Danfoss Link RS is useful in all applicationswhere the actual temperature at the ConnectThermostat is significantly different from the desired room temperature., or if you have multipleradiators in the same room.Do not install DanfossLink RS on outer walls orwhere it will be subject todirect sunlight.Best performance of the system with ConnectThermostats and Danfoss Link RS is achieved,if the RS is not too far from the radiator, bestbetween 1 and 5 meters.The installation heightshould typically bebetween 80-150 cm.Make sure to select the proper settings for theConnect Thermostat and Danfoss Link RS onDanfoss Link CC. Choose the “covered radiator”option if the radiator is behind a fixed radiatorcover and possibly if the radiator and ConnectThermostat is covered by heavy furniture.In wet rooms DanfossLink RS shall be installedaccording to local buildingregulations.At least 50 cm away fromwindows/doors that willbe left open occasionally.VAIDD402 Danfoss07/20165

Application Guide2.Heating Control with Danfoss Link & Connect ThermostatsGeneral Guidelines2.1 Heat supplyIf the heating system has been optimized for constant set temperature around the clock, you mayneed to adjust the settings when working with setback periods. When changing the temperaturefrom a low economy setting to a comfort temperature, the system must be able to supply enoughheat to raise the room temperature at least 1 C per hour to perform well. Compared to a steadytemperature the heating system must typically be able to supply 25% more heat, but only for ashort period of time during heat up.BOOSTENERGYECONOMYCOMFORTHow to achieve 25% extra capacity in a system that should run boost:LimitationsActionMax. ΔP and temperature reached:Increase valve presettingMax. temperature and preset reached:Increase pump pressureMax. preset and ΔP reached:Increase water temperatureNote: Maximum acceptable presetting, water temperature and pump differential pressure settings aredifferent from system to system and depend on the application.For radiator valves with pre-setting, balance the systemto allow for enough flow.The supply line temperature at the radiator valves should beabove 40 C to ensure optimal control.Make sure that the supply water temperature and flow isadequate to provide enough energy.Increase the temperature or the pump level, if necessary.6VAIDD402 Danfoss07/2016min.40 C

Application Guide2.2 FunctionsHeating Control with Danfoss Link & Connect ThermostatsConnect Thermostats have a built-in function, which automatically shut off the heat while the room is ventilated. When thethermostat detects a drop in room temperature, it closes thevalve.To prevent excessive cooling of the room, the thermostat willautomatically open the valve again after 30 minutes, meaningthat during longer periods of ventilation you must manuallyset the temperature down.To prevent multiple detections of ventilation, e.g. caused byopening a door, leading to instability, the thermostat will notdetect a new ventilation session in a period of 45 minutes fromthe previous occurrence.Be aware that a large window sill might prevent the ConnectThermostat from detecting cold air from an open window, andthereby not activate the automatic Open-window function.If the radiator is under or oversized in relation to the room, thesettings should be changed accordingly.Connect Thermostat: to change the settings, please refer tothe Connect Thermostat installation and user guide.VAIDD402 Danfoss07/20167

Application GuideHeating Control with Danfoss Link & Connect ThermostatsThe adaptive learning function (Forecast) ensures that the comfort temperature is reached at settime. The warm up time is continuously adjusted according to seasonal temperature changes. Adaptive learning ensures the wanted temperature at the wanted time (here 20 C at 07:00). Adaptive learning uses data from the previous 7 days to be able to reach the correct temperatureat the right time. Adaptive learning is sensitive to large, rapid temperature changes.129123966Winter: Long warm up time.2.3 RoomsSpring/fall: Short warm up time.Covering the radiator - e.g. with furniture, curtains or a radiator cover - might cause heat to beaccumulated around the thermostat.Light curtain/furniture: Connect Thermostat: canbe used, but function isimproved by using a RSroom sensor. Danfoss Eco : can be used,but it might be necessary toraise the set temperature.Medium curtain/furniture: Connect Thermostat: usewith Danfoss Link RS roomsensor. Danfoss Eco : can be used,but it might be necessary toraise the set temperature.If two radiators are placed within 40 cm of each other, the heatemission from one radiator can affect the thermostat on theother radiator. Connect Thermostat: use with Danfoss Link RS roomsensor. Danfoss Eco : balance the two radiators by adjusting the settemperature on the affected radiator.83VAIDD402 Danfoss07/2016Radiator cover: Connect Thermostat: usewith Danfoss Link RS roomsensor. Danfoss Eco : not recommended in this situation.

Application GuideHeating Control with Danfoss Link & Connect ThermostatsDirect heat radiation from large radiators maydisturb the Connect Thermostats ability tomeasure the room temperature correctly.To avoid this, mount the thermostat pointingaway from the radiator.The optimal solution is a Connect Thermostatwith a Danfoss Link RS room sensor.Danfoss do not recommend to use an angle adapter, instead the valve should be turned or replaced.A fireplace in the room can affect the adaptive learningfunction of the Connecct Thermostat and disturb the heatingcontrol.If you use your fireplace regularly it is recommended todeactivate the adaptive learning.By deactivating the adaptive learning function, Connect willwork as a traditional thermostat, but with a delay in heating upthe room after the fire has burned out.Note: If the valve has been closed for a longer period there may bea delay in heating up the room.Sunlight from large windows in the room can affect theadaptive learning function of the Connect Thermostat anddisturb the heating control. Then it is recommended todeactivate the adaptive learning.By deactivating the adaptive learning function, Connect willwork as a traditional thermostat, but with a delay in heating upthe room after the heating from the sunlight has stopped.Continuous draft from a leaky window or garden door directlyon the Connect Thermostat will disturb the heating control. Connect Thermostat: use with Danfoss Link RS roomsensor. Danfoss Eco : We do not recommend using Danfoss Eco ininstallations where temperature measurement at thethermostat is not representative of the room temperature.In an installation with frequent draft, the regulation maybecome instable and lead to fluctuating temperature andreduced battery life.VAIDD402 Danfoss07/20169

Application GuideHeating Control with Danfoss Link & Connect ThermostatsConnect Thermostats are primarily designed to be used withsupply valves.But Connect Thermostats can also be used with return valveson small radiators (smaller than 120 cm diagonally, rule ofthumb).On larger radiators with return valves Connect Thermostats arenot recommended.Neither Connect Thermostat nor Danfoss Eco should be usedon convectors placed in floor trenches.10VAIDD402 Danfoss07/2016m.ax120cm

Application Guide3.Heating Control with Danfoss Link & Connect ThermostatsApplications3.1 Heating Systemwith BoilerDescriptionA boiler with build-in or external domestic hotwater tank can provide instant heat for theheating system, as well as for the domestic hotwater.The system can be operated with or without aDanfoss Link BR (Boiler Relay).Minimum requirements minimum 40 C supply temperature at thevalve. sufficient heating capacity to increase theroom temperature with 1 C per hour. only radiator valves approved for Danfossadapters.Note! Bypass valve is recommended.RecommendationsCentral room temperaturewith night setbackIf a central room temperature controller is usedin combination with Connect Thermostats, itmust only be as temperature limiter.Max. temp.Central RoomTemperatureControllerComfort temp.ConnectThermostatMin. tempSetback temp.Boiler turned off at nightIf the boiler is turned off or has reduced temperature during the night, then make sure that it isactive when the Connect Thermostat is programmed to warm. In a system with Danfoss Link CCand Connect Thermostat, this can be controlled automatically by adding a boiler relayBoiler OFFBoiler OFFBoiler ONBoiler ONWith Forecast: The Forecast period should varyover the year, but typically the boiler will startup to 3 hours before the comfort period.VAIDD402 Danfoss07/2016Without Forecast: The boiler should typicallystart up ½ hour before the comfort period.11

Heating Control with Danfoss Link & Connect ThermostatsWeather compensationIf the boiler’s heating curve is set to have theradiator thermostats on comfort temperatureconstantly, the curve must be increased in orderto be able to raise the room temperature after asetback period. If the setback periods are long, furtherincrease might be necessary. If the economy periods are short, less increase can be sufficient.80706050403020151050-5Outdoor Air Temperature ( C)Boiler relaySet Danfoss Link BR boiler relay to automatic ON/OFF in the Danfoss Link set-up menu.12VAIDD402 Danfoss07/2016-1020Supply Water Temperature ( C)Application Guide

Application GuideHeating Control with Danfoss Link & Connect Thermostats3.2 Heating Systemwith Central BoilerDescriptionA large gas, oil or pallet boiler which provideshot water to several households.Min. requirements min. 40 C supply temperature at the valve. sufficient heating capacity to increase theroom temperature with 1 C per hour. only radiator valves approved for Danfossadapters.RecommendationsBoiler turned off at nightIf the boiler is turned off or has reduced temperature during the night, then make sure that it isactive when the Connect Thermostat is programmed to warm. In a system with Danfoss Link CCand Connect Thermostat, this can be controlled automatically by adding a boiler relayBoiler OFFBoiler OFFBoiler ONBoiler ONWeather compensationIf the boiler’s heating curve is set to have theradiator thermostats on comfort temperatureconstantly, the curve must be increased in orderto be able to raise the room temperature after asetback period. If the setback periods are long, furtherincrease might be necessary. If the economy periods are short, less increase can be sufficient.Without Forecast: The boiler should typicallystart up ½ hour before the comfort period.80706050403020151050-5-1020Supply Water Temperature ( C)With Forecast: The Forecast period should varyover the year, but typically the boiler will startup to 3 hours before the comfort period.Outdoor Air Temperature ( C)VAIDD402 Danfoss07/201613

Application GuideHeating Control with Danfoss Link & Connect Thermostats3.3 District HeatingDescriptionDistrict heating is generated in a centralizedlocation and distributed to residential andcommercial use.Min. requirements min. 40 C supply temperature at the valve. sufficient heating capacity to increase theroom temperature with 1 C per hour. only radiator valves approved for Danfossadapters.Weather compensation / ECLIf the boiler’s heating curve is set to have theradiator thermostats on comfort temperatureconstantly, the curve must be increased in orderto be able to raise the room temperature after asetback period. If the setback periods are long, furtherincrease might be necessary. If the economy periods are short, less increase can be sufficient.80706050403020151050-5Outdoor Air Temperature ( C)14VAIDD402 Danfoss07/2016-1020Supply Water Temperature ( C)Recommendations

3.4 Heat PumpHeating Control with Danfoss Link & Connect ThermostatsDescriptionA heat pump is generating heating by transferring heat from a relatively low-temperaturereservoir, such as air or ground, to one at ahigher temperature.Min. requirements min. 40 C supply temperature at the valve. sufficient heating capacity to increase theroom temperature with 1 C per hour. only radiator valves approved for Danfossadapters.RecommendationsWeather compensationIf the heat pump’s heating curve is set to havethe radiator thermostats on comfort temperature constantly, the curve must be increased inorder to be able to raise the room temperatureafter a setback period. If the setback periods are long, furtherincrease might be necessary. If the economy periods are short, less increasecan be sufficient.80706050403020151050-5-1020Supply Water Temperature ( C)Application GuideOutdoor Air Temperature ( C)If system is installed during period with outside temperature 10 C opening point will not befound untill temperature drops below 7-8 C. Can be solved by manually setting the heating curvehigher during the run in period (approx. 1 week).VAIDD402 Danfoss07/201615

Application Guide16Heating Control with Danfoss Link & Connect ThermostatsVAIDD402 Danfoss07/2016

Application uide Heating Control with Danfoss Link Connect Thermostats 4 VAIDD402 Danfoss 07/2016 1.4 Number of units in a Danfoss Link system When building a wireless Danfoss Link control system it is important to follow these rules: 1. The total number of units must not e

Related Documents:

Amazon SageMaker Amazon Transcribe Amazon Polly Amazon Lex CHATBOTS Amazon Rekognition Image Amazon Rekognition Video VISION SPEECH Amazon Comprehend Amazon Translate LANGUAGES P3 P3dn C5 C5n Elastic inference Inferentia AWS Greengrass NEW NEW Ground Truth Notebooks Algorithms Marketplace RL Training Optimization Deployment Hosting N E W AI & ML

FOR INDUSTRIAL HEATING OF AIR AND GAS UP TO 800 C (1470 F) Traditional heating cassettes are commonly equipped with tubular heating elements as the heating source. The design of these elements limits the maximum reachable air/gas temperature to about 600 C (1110 F). With the state of art heating element design used in our Kanthal heating .

You can offer your products on all Amazon EU Marketplaces without having to open separate accounts locally. Amazon Marketplaces include Amazon.co.uk, Amazon.de, Amazon.fr, Amazon.it and Amazon.es, countries representing over 80% of European Ecommerce spend. You have a single user interface to manage your European seller account details.

Why Amazon Vendors Should Invest In Amazon Marketing Services 7 The Amazon Marketing Services program provides vendors an opportunity to: Create engaging display ad content Measure ad content success Reach potential customers throughout Amazon and Amazon-owned & operated sites Amazon Marketing Services offers targeting options for vendors to optimize their

Amazon S3: Amazon S3 is a highly durable, scalable, secure, fast, and inexpensive storage service. With the EMR File System (EMRFS), Amazon EMR can efficiently and securely use Amazon S3 as an object store for Hadoop. Amazon EMR has made numerous improvements to Hadoop, allowing you to seamlessly process large amounts of data stored in Amazon S3.

District heating often involves a heating substation installed in the basement of a building. It receives the heating carrier from a heat generating station and via a heat exchanger makes it available for the building heating system. An individual heating system in many cases consists of a boiler heating water up to required temperature for

What level of control is there in a hydronic underfloor heating system? 11 Design & installation issues to consider when planning underfloor heating 12 Design & installation process for underfloor heating systems 18 Our Expertise 19 Introduction This guide is intended as a basic guide to the fundamentals of hydronic underfloor heating to assist .

The Connector for Amazon continuously discovers Amazon EC2 and VPC assets using an Amazon API integration. Connectors may be configured to connect to one or more Amazon accounts so they can automatically detect and synchronize changes to virtual machine instance inventories from all Amazon EC2 Regions and Amazon VPCs.