Trane Product Data Upflow/Horizontal Right Or Upflow .

2y ago
9 Views
2 Downloads
729.73 KB
20 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Kaleb Stephen
Transcription

TDD-D-1Upflow/Horizontal Rightor Upflow/Horizontal LeftCondensing Gas FurnaceXT TDX1B080A9H31BTDX1C100A9H41BTDX1D120A9H51BPUB. NO. 22-1786-06

GeneralFeaturesNATURAL GAS MODELSCentral Heating furnace designs arecertified by the American and CanadianGas Association for both natural and L.P.gas. Limit setting and rating data wereestablished and approved under standard rating conditions using AmericanNational Standards Institute standards.SAFE OPERATIONThe Integrated System Control has solidstate devices, which continuously monitorfor presence of flame, when the system isin the heating mode of operation. Dualsolenoid combination gas valve andregulator provide extra safety.QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to increaseefficiency and provide a positive discharge of gas fumes to the outside.BURNERSMultiport Inshot burners will give years ofquiet and efficient service. All modelscan be converted to L.P. gas withoutchanging burners.INTEGRATED SYSTEM CONTROLExclusively designed operational program provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self diagnostics forease of service. Also contains connection points for E.A.C./humidifier. 2009 TraneAll Rights Reserved2AIR DELIVERYThe four speed, direct drive blowermotor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speeds ondemand from room thermostat. Theblower door safety switch will prevent orterminate furnace operation when theblower door is removed.STYLINGHeavy gauge steel and “wrap-around”cabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglassinsulation. This results in quiet andefficient operation due to the excellentacoustical and insulating qualities offiberglass. Built-in bottom pan andalternate bottom, left or right side returnair connection provision.FEATURES ANDGENERAL OPERATIONThe XT90 High Efficiency Gas Furnacesemploy a Silicon Carbide Hot SurfaceIgnition system, which eliminates thewaste of a constant burning pilot. Theintegrated system control lights the mainburners upon a demand for heat from theroom thermostat. Complete front serviceaccess.a. Low energy power venterb. Vent proving pressure switch.Pub. No. 22-1786-06

ContentsGeneral Features2Features and Benefits4Standard EquipmentOptional EquipmentGeneral DataPub. No. 51B5566677778Performance Data10Field Wiring12Dimensions14Electrical Data153

Featuresand BenefitsXT 90 UPFLOW/HORIZONTAL RIGHT or LEFT STANDARD EQUIPMENT Convertible to horizontal with left orright airflow Gasketed blower door Common vent capability Internal filter rack Power supply 115/1/60 Type 29-4CTM stainless steelsecondary heat exchanger Standard filter sizes Heavy gauge reinforced wrap-aroundsteel cabinet Cleanable high velocity filters Optional L.P. conversion kit Silicon Nitride Hot surface igniter withadaptive heat up Heavy gauge aluminized steel heatexchanger Left/right gas connection Integrated solid state control with selfdiagnostics Blower door safety switch Multi-port In-shot burners Selectable cooling fan off eliminatesneed for BAY24X045 time delay relay Single wire twinning Complete front service access 24 volt fuse Attractive color accents Alternate bottom/left/right return air Manual reset flame roll-out switches Hinged blower door Slide out blower assembly Prefect Fit door latches Constant torque ECM blower motor Insulated blower door Adjustable fan off times Accessory hook-up capabilityXT90 Optional Equipment ] indicates accessories included).OPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [ For Comfort Controls, See price book pages . [CleanEffectsTM Whole House Air Cleaner (14-1/2" Wide, Upflow / Side Return Furnace) . TFD145ALFR000A [CleanEffectsTM Whole House Air Cleaner (17-1/2" Wide, Upflow / Side Return Furnace) . TFD175ALFR000A [CleanEffectsTM Whole House Air Cleaner (21" Wide, Upflow / Side Return Furnace) . TFD210ALFR000A [CleanEffectsTM Whole House Air Cleaner (24-1/2" Wide, Upflow / Side Return Furnace) . TFD245ALFR000A [CleanEffectsTM Whole House Air Cleaner (14-1/2" Wide, Downflow Furnace) . TFD14DALFR000A [CleanEffectsTM Whole House Air Cleaner (17-1/2" Wide, Downflow Furnace) . TFD17DALFR000A [CleanEffectsTM Whole House Air Cleaner (21" Wide, Downflow Furnace) . TFD21DALFR000A [CleanEffectsTM Whole House Air Cleaner (24-1/2" Wide, Downflow Furnace) . TFD24DALFR000A [Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) . TFM145A9FR0 [Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) . TFM175A9FR0 [Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) . TFM210A9FR0 [Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) . TFM245A9FR0 [Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) . TFP145A9FR0 [Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) . TFP175A9FR0 [Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) . TFP210A9FR0 [Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) . TFP245A9FR0 [Coil Enclosure (14-1/2" Wide Cabinets) . BAYCLE14A1422A [Coil Enclosure (17-1/2" Wide Cabinets) . BAYCLE17A1722A [Coil Enclosure (21" Wide Cabinets) . BAYCLE21A2130A [Coil Enclosure (24-1/2" Wide Cabinets) . BAYCLE24A2430A [High Altitude Switch . BAYHALT248 [Downflow Subbase . BAYBASE205 [Propane Conversion Kit . BAYLPKT210B [Propane Conversion Kit (With Stainless Steel burners) . BAYLPSS210B [Masonry Chimney Vent Kit . BAYVENT800B [Filter Access Door Kit (Downflow models) . BAYFLTR206 [4]]]]]]]]]]]]]]]]]]]]]]]]]]]Pub. No. 22-1786-06

GeneralDataPRODUCT SPECIFICATIONS 1MODELTYPERATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP 5R.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT PIPE DIAMETER— Min (in.)67HEAT EXCHANGERType-Fired-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)TUX1B040A9H21BUpflow / HorizontalTUX1B060A9H31BUpflow / HorizontalTUX1B080A9H31BUpflow / Horizontal40,00038,00092.130 - 60DIRECT10 x 71460,00056,00092.130 - 60DIRECT10 x 71480,00074,00092.135 - 65DIRECT10 x 814See Fan Performance TableSee Fan Performance TableSee Fan Performance Table1/21075115/1/60CentrifugalDirect - 11/55 - 3000115/1/601.0YesHigh Velocity1 - 17x25 - 1in.2 Round1/21075115/1/60CentrifugalDirect - 11/55- 3000115/1/601.0YesHigh Velocity1 - 17x25 - 1in.2 Round1/21075115/1/60CentrifugalDirect - 11/24 - 3200115/1/601.35YesHigh Velocity1 - 17x25 - 1in.2 RoundAluminized SteelAluminized SteelAluminized Steel2020202 — 452 — 563 — 453 — 564 — 454 — 56Redundant - Single StageRedundant - Single StageRedundant - Single StageHot Surface IgnitionMultiport Inshot2115/1/609.7151/2HxWxDHot Surface IgnitionMultiport Inshot3115/1/609.7151/2HxWxDHot Surface IgnitionMultiport Inshot4115/1/6010.0151/2HxWxD41-3/4 x 19-1/2 x 30-1/241-3/4 x 19-1/2 x 30-1/241-3/4 x 19-1/2 x 30-1/2139 / 129150 / 140158 / 1481 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Constant torque ECM blower motor.6 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length labelon the furnace.7 All *UX1 and *DX1 furnace models have a vent outlet diameter that equals 2".Pub. No. 22-1786-065

GeneralDataPRODUCT SPECIFICATIONS 1MODELTYPERATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP 5R.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT PIPE DIAMETER— Min (in.)67HEAT EXCHANGERType-Fired-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)TUX1C100A9H41BUpflow / HorizontalTUX1D120A9H51BUpflow / Horizontal100,00093,00092.135 - 65DIRECT11 x 1014120,000112,00092.140 - 70DIRECT11 x 1014See Fan Performance TableSee Fan Performance Table3/41100115/1/60CentrifugalDirect - 11/20- 3450115/1/60.71YesHigh Velocity1 - 20x25 - 1in.2.5 Round11100115/1/60CentrifugalDirect - 11/20- 3450115/1/60.71YesHigh Velocity1 - 24x25 - 1in.2.5 RoundAluminized SteelAluminized Steel20205 — 455 — 566 — 456 — 56Redundant - Single StageRedundant - Single StageHot Surface IgnitionMultiport Inshot5115/1/6012.4201/2HxWxDHot Surface IgnitionMultiport Inshot6115/1/6014.5201/2HxWxD41-3/4 x 23 x 30-1/241-3/4 x 26-1/2 x 30-1/2171 / 162205 / 1931 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Constant torque ECM blower motor.6 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length labelon the furnace.7 All *UX1 and *DX1 furnace models have a vent outlet diameter that equals 2".6Pub. No. 22-1786-06

GeneralDataPRODUCT SPECIFICATIONS 1MODELTYPERATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP 5R.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT PIPE DIAMETER— Min (in.)67HEAT EXCHANGERType-Fired-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)TDX1B040A9H21BDownflow / HorizontalTDX1B060A9H31BDownflow / HorizontalTDX1B080A9H31BDownflow / Horizontal40,00038,00091.030 - 60DIRECT10 x 71460,00056,00091.030 - 60DIRECT10 x 81480,00074,00091.035 - 65DIRECT10 x814See Fan Performance TableSee Fan Performance TableSee Fan Performance Table1/21080115/1/60CentrifugalDirect - 11/55- 3000115/1/601.14YesHigh Velocity1 - 14x20 - 1in.2 Round1/21075115/1/60CentrifugalDirect - 11/55- 3000115/1/601.0YesHigh Velocity2 - 14x20 - 1in.2 Round3/41075115/1/60CentrifugalDirect - 11/25- 3200115/1/601.35YesHigh Velocity2 - 14x20 - 1in.2 RoundAluminized SteelAluminized SteelAluminized Steel2020202 — 452 — 563 — 453 — 564 — 454 — 56Redundant - Single StageRedundant - Single StageRedundant - Single StageHot Surface IgnitionMultiport Inshot2115/1/609.7151/2HxWxDHot Surface IgnitionMultiport Inshot3115/1/609.7151/2HxWxDHot Surface IgnitionMultiport Inshot4115/1/6012.4151/2HxWxD41-3/4 x 19-1/2 x 30-1/241-3/4 x 19-1/2 x 30-1/241-3/4 x 19-1/2 x 30-1/2145 / 135155 / 145168 / 1581 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Constant torque ECM blower motor.6 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length labelon the furnace.7 All *UX1 and *DX1 furnace models have a vent outlet diameter that equals 2".Pub. No. 22-1786-067

GeneralDataPRODUCT SPECIFICATIONS 1MODELTYPERATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUETemp. rise (Min.-Max.) F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP 5R.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT PIPE DIAMETER— Min (in.)67HEAT EXCHANGERType-Fired-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)TDX1C100A9H41BDownflow / HorizontalTDX1D120A9H51BDownflow / Horizontal100,00094,00091.035 - 65DIRECT11 x 1014120,000110,00091.040 - 70DIRECT11 x 1014See Fan Performance TableSee Fan Performance Table3/41075115/1/60CentrifugalDirect - 11/20- 3450115/1/60.71YesHigh Velocity2 - 16x20 - 1in.2.5 Round11075115/1/60CentrifugalDirect - 11/20- 3450115/1/60.71YesHigh Velocity2 - 16x20 - 1in.2.5 RoundAluminized SteelAluminized Steel20205 — 455 — 566 — 456 — 56Redundant - Single StageRedundant - Single StageHot Surface IgnitionMultiport Inshot5115/1/6012.4201/2HxWxDHot Surface IgnitionMultiport Inshot6115/1/6015.5201/2HxWxD41-3/4 x 23 x 30-1/241-3/4 x 26-1/2 x 30-1/2185 / 175206 / 1961 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Constant torque ECM blower motor.6 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length labelon the furnace.7 All *UX1 and *DX1 furnace models have a vent outlet diameter that equals 2".8Pub. No. 22-1786-06

PerformanceDataFURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins.w.g.)MODELSPEED TAP0.10.20.30.40.50.60.70.80.9*UX1B040A9H21B4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - 04497930662563454*UX1B060A9H31B4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - 64811229898136011061955780554*UX1B080A9H31B4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - 0A9H41B4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - 20A9H51B4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - 1B040A9H21B4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - 69471852641536431*DX1B060A9H31B4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - 0909206905711030883651531*DX1B080A9H31B4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - 967501202111186471211011072831674*DX1C100A9H41B4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - 38153512009371590149711548871542145911088374 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - E: Do NOT use theLOW speed tap for heating*DX1D120A9H51B* May be "A" or "T"Pub. No. 22-1786-069

PerformanceDataCFM VS. TEMPERATURE RISECFM (CUBIC FEET PER MINUTE)

Jun 22, 2012 · OPTIONAL EQUIPMENT FOR CONDENSING UNITS . 6Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length labelon the furnace. 7All *UX1 and *DX1 furnace models have a vent outlet diameter that equals 2". PRO

Related Documents:

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers Black Epoxy Coil GAF2A0A18S11EE GAF2A0A24S21EE GAF2A0A30S21EE GAF2A0A36S31EE. 2 Pub. No. 22-1858-10 Features and Benefits . Horizontal Left Horizontal Right 1 1 Upflow . Trane .

Rheem Classic Series Upflow/Horizontal Gas Furnaces FORM NO. G11-518 RGPN- Series 80% A.F.U.E.† Models with Input Rates from 50-150 kBTU (U.S. & Canadian Models) he Rheem Classic Series line of upflow/horizontal gas ooms, closets, alcoves, or attics. file 34 inch [864 mm] height, the upflow model can also be used to satisfy most appli-

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace PUB. NO. 22-1836-12 XR 95 TUH1B040A9241C, TUH1B060A9361C,

REPLACEMENT PARTS LIST *L and *G Series 78 , 80 and 90 Models *G6RA and G6TA 80 Upflow/Horizontal *G6RK 80 Downflow *L1RA 78 Upflow/Horizontal *G6RC, G6RD and *G6TC 90 Upflow/Horizontal *G6RL and *G6TL 90 Downflow *Model description may be prefixed with an alphanumeric character. 2

Trane Technicians will capture and track all refrigerant activity performed by Trane for each piece of Covered Equipment Refrigerant Usage Reports can be generated annually 0 Trane Laboratory Analysis The Trane Chemical Laboratory performs routine analysis and trending of oil, absorption

Tracer UC210 Trane VAV Controller Tracer UC400 Trane- and field-applied terminal equipment (VAV, WSHP, fan coil, blower coil, generic) BCI-I (IPAK) Trane IntelliPak Rooftop equipment BCI-R (Reliatel) Trane Voyager and Precedent Rooftops Tracer UC600

Trane Xv95 Installation Manual instructions guide, service manual guide and maintenance manual guide on your products. Before by using this manual, service or . Trane Xv95 Xl16I Heat Pump - Honeywell Visionpro. . Manual Trane RTAA-200 Manuals Download 254 Trane Chiller P

Rheem Prestige Series Two-Stage Upflow/Horizontal Gas Furnace equipped with The Comfort Control2 System FORM NO. G11-512 RGPE- Series 80% A.F.U.E.† Input Rates 50-125 kBTU A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. he Rheem estige Series o-Stage line of upflow .