Service ManualDatascopeSpectrum DatascopeSpectrum 0070-01-0556-02 revD srvc color.indd 19/26/12 9:14 AM

Service ManualDatascopeSpectrum DatascopeSpectrum 0070-02-0556-02 revE srvc b w.indd 19/26/12 9:14 AM

A-2000 is a trademark of Aspect MedicalSystems, Inc.Navigator is a U.S. trademark ofMindray DS USA, Inc.Abbott is a U.S. registered trademark ofAbbott Laboratories.Nellcor is U.S. registered trademark of NellcorPuritan Bennett Inc.Aspect is a trademark of Aspect MedicalSystems, Inc.NIV Line is a trademark of OridionMedical Ltd.Bispectral Index is a trademark of AspectMedical Systems, Inc.Oxiband is a U.S. registered trademark ofNellcor Puritan Bennett Inc.BIS is a trademark of Aspect MedicalSystems, Inc.OxiMax is a US registered trademark ofNellcor Puritan Bennett Inc.BISx is a trademark of Aspect MedicalSystems, Inc.Oxisensor is a U.S. registered trademark ofNellcor Puritan Bennett Inc.CapnoLine is a trademark of OridionMedical Ltd.Oxismart is a U.S. registered trademark ofNellcor Puritan Bennett Inc.Durasensor is a U.S. registered trademark ofNellcor Puritan Bennett Inc.Panorama is a U.S. trademark ofMindray DS USA, Inc.Edwards is a U.S. registered trademark ofEdwards Lifesciences Corporation.Passport 2 is a U.S. registered trademark ofMindray DS USA, Inc.FilterLine is a U.S. registered trademark ofOridion Medical Ltd.PatientNet is a U.S. registered trademark of GEMedical Systems Information Technologies.LaserJet is a U.S. registered trademark ofHewlett Packard.Spectrum is a U.S. registered trademark ofMindray DS USA, Inc.LNOP is a U.S. registered trademark ofMasimo Corp.Spectrum OR is a U.S. trademark of MindrayDS USA, Inc.Masimo SET is a U.S. registered trademarkof Masimo Corp.Velcro is a registered trademark of VelcroIndustries B.V.Max-Fast is a U.S. registered trademark ofNellcor Puritan Bennett Inc.View 12 is a U.S. trademark ofMindray DS USA, Inc.MediCO2 is a registered trademark ofOridion Medical Ltd.Vigilance is a US registered trademark ofEdwards Lifesciences Corporation.miniMediCO2 is a registered trademark ofOridion Medical Ltd.Visa is a U.S. registered trademark of MindrayDS USA, Inc.Microstream is a U.S. registered trademarkof Oridion Medical Ltd.Copyright Mindray DS USA, Inc., 2008. All rights reserved.Contents of this publication may not be reproduced in anyform without permission of Mindray DS USA, Inc.0070-10-0556-02Spectrum /Spectrum OR Service Manual

Table of ContentsForeword . vNote . vWarning. vRepair Information . 1 - 1Introduction .1 - 1Safety Precautions.1 - 1Troubleshooting Guidelines .1 - 2Exchange Programs .1 - 2Special Tools Required .1 - 2Disassembly Instructions.1 - 3Nurse Call Cable (3 Pin Circular to Unterminated) .1 - 7P/N 0012-00-1277-01/-02 .1 - 7VGA Extension Cables .1 - 8Male 15 Pin D-Shell to Female 15 Pin D-Shell and Open Ended to Female 15 Pin D-Shell .1 - 8Serial Port to Gas Module II/SE/SE with Spirometry Cable (P/N 0012-00-1276-XX) .1 - 9Serial Port to Serial Port Cable(P/N 0012-00-1275-01).1 - 1026 pin Molex to Mini Phone Plug (DPD Sync Cable).1 - 11ECG Shielded Lead Wires .1 - 12ECG Shielded Lead Wires .1 - 13Panorama Mobility Lead Wires .1 - 14ECG Cable ESIS and Non ESIS .1 - 15Panorama Mobility Cable (ESIS and Non ESIS) .1 - 16View 12 Card Assembly .1 - 1712 Lead Wire Set .1 - 17Cardiac Output Cable.1 - 18IABP Cable .1 - 19ECG Only .1 - 19ECG/IBP (only for serial numbers MSXXXXX-K5 and higher) .1 - 19Serial Port to RJ 45 Cable (VISA) .1 - 20BISx Module.1 - 21BISx Sensors.1 - 21Beep Tones .1 - 22Troubleshooting Menus.1 - 23ECG Troubleshooting .1 - 23NIBP Troubleshooting.1 - 24SpO2 Troubleshooting.1 - 26Temperature Troubleshooting .1 - 27Respiration and CO2 Troubleshooting .1 - 27Gas Module Troubleshooting .1 - 28IBP Troubleshooting .1 - 32PAWP Troubleshooting.1 - 32EPM Cardiac Output Troubleshooting .1 - 33Vigilance Cardiac Output Troubleshooting.1 - 34BIS Troubleshooting .1 - 34Alarm Troubleshooting .1 - 35Trends Troubleshooting.1 - 36Printer/Recorder Troubleshooting .1 - 36Monitor/Display Troubleshooting .1 - 37Installation Menu .1 - 38Installation Mode.1 - 38Transferring Monitor Default Settings.1 - 40Spectrum /Spectrum OR Service Manual0070-10-0556-02i

Table of ContentsOption Installation .1 - 41System Information Menu.1 - 42Trend Storage .1 - 44Installation and Use of the Extended Trend Feature .1 - 44Software Download .1 - 44Download Operation .1 - 44Block Diagrams . 2 - 1Introduction .2 - 1Block Diagram.2 - 2Isometric Drawings and Part List . 3 - 1Introduction .3 - 1Top Level Assembly .3 - 2Front Housing Assembly.3 - 6Rear Housing Assembly .3 - 9External Parameter Module .3 - 26Comm-Port .3 - 28Calibration Procedure . 4 - 1Introduction .4 - 1Warning and Guidelines .4 - 1Test Equipment and Special Tools Required.4 - 2Diagnostics .4 - 3Keypad / Control Knob Test .4 - 4Recorder Test .4 - 5Display Tests .4 - 6Pixel Test .4 - 6Color Test .4 - 7NIBP Tests .4 - 8Error Log .4 - 16Microstream CO2 Calibration .4 - 17Verification .4 - 19Initial Set-up .4 - 19ECG Tests.4 - 21IBP 1, IBP 2, IBP 3 and IBP 4 (Optional) Verification .4 - 22Temperature Verification.4 - 22SpO2 Verification .4 - 23NIBP Verification .4 - 23Battery Operation Verification .4 - 23Battery Back-up Verification .4 - 23CO2 Operation Verification.4 - 23Cardiac Output Verification .4 - 24BISx Verification .4 - 24Leakage Current Tests .4 - 26Preventative Maintenance. 5 - 1Preventative Maintenance Schedule .5 - 1Mechanical / Physical / Visual Inspection - Perform At Twelve Month Intervals.5 - 1Perform Verification and NIBP Calibration – Annually .5 - 1Perform Verification and CO2 Calibration .5 - 1Perform Battery Back-Up Verification - Annually .5 - 2User Preventative Maintenance Introduction .5 - 3Care and Cleaning of the Monitor .5 - 3Decontamination of the Monitor.5 - 3Care and Cleaning of SpO2 Sensors.5 - 3ii0070-10-0556-02Spectrum /Spectrum OR Service Manual

Table of ContentsCleaning and Re-use of a Nellcor Sensor.5 - 4Cleaning CO2 Sensors, Adapters and Sampling Components .5 - 4Sterilization and Cleaning of Reusable Cuffs .5 - 4Reusable Cuffs with Bladders .5 - 4Reusable Bladderless Cuffs .5 - 5Disposable Blood Pressure Cuffs .5 - 5Care and Cleaning of Gas Module .5 - 5Care and Cleaning of 3 and 5-lead ECG Cables and Leadwires .5 - 6Care and Cleaning of View 12 ECG Analysis Module.5 - 7Battery Replacement and Maintenance .5 - 7Battery Replacement .

Mindray DS USA, Inc. . The Spectrum /Spectrum OR Service Manual is intended as a guide for technically qualified personnel during repair and calibration procedures. This publication may have been updated to reflec

Related Documents:

SHENZHEN MINDRAY BIO-MEDICAL ELECTR ONICS CO., LTD. (hereinafter called Mindray) owns the intellectual property rights to this Mindray product and this manual. This manual may refer to information protected by copyrights or patents and does not convey any license under the patent rights of Mindray, nor the rights of others. Mindray does not assume

Manufacturer: Shenzhen Mindray Bio-Medical Electronics Co., Ltd. Address Mindray Building, Keji 12th Road South, Hi-tech industrial park, Nanshan, Shenzhen 518057, P.R.China Website www.mindray.com E-mail Address: service@mindray

Mindray or repairs by people other than Mindray authorized personnel. This warranty shall not extend to: z any Mindray product which has been subjected to misuse, negligence or accident; z any Mindray product from which Mindray's original serial number tag or product identification markings have been altered or removed;

Mindray DS USA, Inc. A Series Communication Protocol Interface Guide This publication contains data proprietary to Mindray DS USA, Inc. It is provided solely for use by qualified personnel to interface external devices with certain Mindray devices. Mindray DS USA, Inc. assumes no responsibility for any adverse interaction resulting from the use .

1. Obtain return authorization: Contact the Mindray Service Department and obtain a Customer Service Authorization (Mindray) number. The Mindray number must appear on the outside of the shipping container. Returned shipments will not be accepted if the Mindray number is not clearly visible. Please provide the model number, serial number,File Size: 2MB

Mindray DS USA, Inc. 800 MacArthur Blvd., Mahwah, NJ USA 07430 Tel: 800.288.2121 or 201.995.8000 Fax: 800.926.4275 www.mindray.com Mindray North America Headquarters Mahwah, NJ Exceptional service and support Mindray i

With the next generation of technologies, the Mindray M9 offers . Tel: 800.288.2121 or 201.995.8000 Fax: 800.926.4275 www.mindray.com Mindray North America Headquarters Mahwah, NJ Exceptional service and support Mindray is a global medical device business with three established . 10/7/2014 1:40:46 PM .

www.mindray.com Welcome to the Mindray North America Parts and Accessories Catalog This catalog will provide you with the parts and accessories that connect to your Mindray Anesthesia Delivery