RSANTA FE PELLET STOVEOwner’s ManualInstallation and OperationModel:SANTAFE-B1BeavertonOregon USATested andListed byCOMNI- Test Laboratories, Inc .CAUTIONDO NOT DISCARD THIS MANUAL Important operating and Read, understand andfollow these instrucmaintenance instructions for safe installations included.tion and operation.WARNING Leave this manual withOTDO N ARDCDISparty responsible for useand operation.WARNINGPlease read this entire manualbefore installation and use of thispellet fuel-burning room heater.Failure to follow these instructionscould result in property damage,bodily injury or even death.HOT! DO NOT TOUCH.SEVERE BURNS MAY RESULT.CLOTHING IGNITION MAY RESULT.Glass and other surfaces are hotduring operation and cool down. Keep children away. Do not store or use gasoline or other flam-mable vapors and liquids in the vicinity of thisor any other appliance. Do not overfire - If any external part starts toglow, you are overfiring. Reduce feed rate.Overfiring will void your warranty. Comply with all minimum clearances to combustibles as specified. Failure to comply maycause house fire. CAREFULLY SUPERVISE children in same room asappliance. Alert children and adults to hazards of hightemperatures. Do NOT operate with protective barriers open orremoved. Keep clothing, furniture, draperies and othercombustibles away.CAUTIONCAUTIONTested and approved for wood pellets and shelledfield corn fuel only. Burning of any other type of fuelvoids your warranty.www.quadrafire.comCheck building codes prior to installation. Installation MUST comply with local, regional, stateand national codes and regulations. Consult local building, fire officials or authorities havingjurisdiction about restrictions, installation inspection,and permits.7001-142CNovember 2, 2005

Santa Fe Pellet StoveRHearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance,you have our assurance of commitment to quality, durability, and performance.meticulously fabricated and gold and nickel surfaces arehand-finished for lasting beauty and enjoyment. Our pledgeto quality is completed as each model undergoes a qualitycontrol inspection. From design, to fabrication, to shipping:Our guarantee of quality is more than a word, it’s QuadraFire tradition, and we proudly back this tradition with a Limited Lifetime Warranty.This commitment begins with our research of the market,including ‘Voice of the Customer’ contacts, ensuring wemake products that will satisfy your needs. Our ResearchWe wish you and your family many years of enjoyment in theand Development facility then employs the world’s mostwarmth and comfort of your hearth appliance. Thank you foradvanced technology to achieve the optimum operation ofchoosing Quadra-Fire.our stoves, inserts and fireplaces. And yet we are oldfashioned when it comes to craftsmanship. Each unit isWith warm regards,Alan TruslerSenior Vice PresidentDealer ChannelJason OlmsteadVice President &General ManagerDan HenryVice PresidentAdvancedTechnologiesSteve TateQuadra-Fire Brand ManagerDave FiebelkornMaterials ManagerSAMPLE: CLEARANCE TO COMBUSTIBLES LABELLOCATION: Back side of left side panel.CAUTION:HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING ANDFURNITUREAWAY. CONTACT MAY CAUSESKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS.Operatethisunitwithfuelhopperlid closed.Failureto do so mayresultin emissionsproducts'combustionfromthehopper under certain conditions. Maintain hopper seal in good condition. Do no over fill the hopper.CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER.GARDEZLES ENFANTS ET LES VÊTEMENTSLOINDE L'ESPACE DÉSIGNÉDE L'INSTALLATION.LE CONTACT PEUT CAUSERDES BRÛLURESÀ LA PEAU. VOIR L'ÉTIQUETTEET LESINSTRUCTIONS. Opérezcet appareilavecle couverclede la trémiefermé.Le défautde ne pas suivreles instructionspeutrésulter,sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.ATTENTION:BeavertonOregon USACOMNI-Test Laboratories, .IncListed byReport / Rapport061-S-53-2RSanta Fe Pellet StoveSERIAL NO. / NUMÉRO DU007Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile HomeInstallation. This appliance has been tested and listed for use in Manufactured Homesin accordance with OAR 814-23-9000 through 814-23-909.Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans l'installationdans les maisons mobiles. Cet appareil a été testé et enregistré pour l'usage dans les MaisonsMobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.Tested to: ASTM E1509, ORD-C-1482-M199 0 Room Heatin g Pellet Burning Type,APFI, (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORNFUEL.Input Rating: 30,000 Btu's/hrElectrical Rating: 115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 AMPS .Route power cord away from unit. Do not route cord under or in front of appliance.DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replaceglass only with 5mm ceramic available from your dealer. To start, set thermostat aboveroom temperature, the stove will light automaticall y. To shutdown, set thermostat to belowroom temperature. For further instruction refer to owner's manual.Keep viewing and ash removal doors tightly closed during operation.Testé à: ASTM E1509-95, ORD-C 1482-M1990 Room Heating. Pellet Burning Type, APFI, (UM)84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉDES CHAMPS.Puissance de Rendement: 30,000 Btu's/hrPuissance Électrique: 115 VAC, 60 Hz, Début 4.1 Amps, Courir 1.1 Amps,Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil.DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant leservice.Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.Pour allume r, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumeraautomatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de lapièce. Pour des instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la ported'ouverture et la porte des cendres fermées hermétiquement durant l'opération.GIG 2"/51mmH* 2"/51mmI 6"/152mmIf Cas t Bas e is installe d (Par t 811-0840 ) use a noncombustibl e floorprotecto r, extendin g beneat h heate r and to the front/sides/rea r asindicated. Measure front distance (I) from the surface of the glass door. IfCast Base is not installed, the non-combustible floor protector must be 1/4"(6.4mm) minimum thickness ("k" value 0.84).*Non-combustible floor protection must extend beneath the flue pipe wheninstalled with horizontal venting or under the Top Vent Adapter with verticalinstallation. RECOMMENDED IN USA; REQUIRED IN CANADAManufactured by:Fabriqué par :Test Lab &Report No.Installezet utilizeretayagedu fonte (Pièce811-0840),le poêledoit être placésur une assisenoncombustibles’étendanttout autourde lui, commeles schémasl’indiquent. Mesurezla distancedudevant (I) de la surface de la porte vitrée.Ne pasinstallezétayagedu fonte le protecteurde plancherdoitêtred'unminimumde 1/4"(6.4mm)d'épaisseur, ('k" value 0.84) de matériel incombustible ou équivalent.*Un protecteur incombustiblede plancherdoit s'étendre sous le conduitde cheminéepour une installation de ventilation horizontale ou sous un adapteur de ventilation dedessus pour une installation verticale. ÉTATS-UNIS-RE COMMANDÉ ; CANAD A REQUIREN T.U.S. ENVIRONMENTAL PROTECTION AGENCYThis model is exempt fromPAE certification under 40 CFR 60.531 by definitionWood[ Heater (A) "Air-to-Fuel Ratio"].200520062007JANFEBMARAPRMAYJUNEJU LYAUGSEPTOCTNOVDEC1445 Highway NorthColville, WA 99 114ww w.quadrafire.co mPage 2Model NameFLOOR PROTECTION / PROTECTION DU SOL*HGSerial NumberDO NOT REMOVE THIS LABEL / NEPAS ENLEVER L'ÉTIQUETTEMade in U.S.A./Fait Aux er 2, 2005

Santa Fe Pellet StoveRRTABLE OF CONTENTSSection 1: Listing and Code ApprovalsA.B.C.D.E.Appliance Certifications .4Mobile Home Approved .4Glass Specifications .4Electrical Rating .4BTU & Efficiency Specifications .4Section 9: Troubleshooting .25-27Section 10: Maintaining & Servicing ApplianceA.B.C.D.E.F.G.Section 2: Getting StartedA. Design, Installation & LocationConsiderations .5B. Fire Safety .5C. Tools & Supplies Needed .6D. Measuring Standards .6E. Inspect Appliance & Componentsand Pre-Use Check List .6General Maintenance & Cleaning .28-30High Ash Fuel Content Maintenance .31Blower Replacement .31Igniter Replacement .32Baffle & Brick Removal .32Baffle & Brick Replacement .33Glass Replacement .34Section 11: Reference MaterialA.B.C.D.E.F.Section 3: Dimensions & ClearancesA. Appliance Dimensions .7B. Clearances to Combustibles .8C. Hearth Requirements .9Component Functions .36-37Component Locations .38Exploded Drawings .39-40Service Parts & Accessories .41-42Warranty Policy .43Contact Information .44Section 4: Vent InformationA.B.C.D.Chimney & Exhaust Connection .10Venting Termination Requirements .10Equivalent Feet of Pipe .11Pipe Selection Chart .11Section 5: Venting SystemsA.B.C.D.E.F.Alcove .12Through the Wall .13Vertical .14Through the Wall & Vertical .14Masonry .15Alternate Masonry .15Section 6: Mobile Home .16Section 7: Appliance Set-UpA. Outside Air Kit .17B. Top Vent Adapter .18C. Log Set Placement .19D. Grille & Trim Ring Installation .20E. Thermostat Installation .21Section 8: Operating InstructionsA.B.C.D.E.F.G.H.Fuel Size & Material .22General Operation Information .22Before Your First Fire .23Starting Your First Fire.23Fire Characteristics .23Feed Rate Adjustment .23Ignition Cycles .24Frequently Asked Questions .24November 2, 20057001-142CPage 3

1Santa Fe Pellet StoveRListing and Code ApprovalsE. BTU & Efficiency SpecificationsA. Appliance CertificationModel:Santa Fe Pellet StoveLaboratory:OMNI Test Laboratories, Inc.Particulate Emissions Rating:0.7 grams/hrReport No.061-S-53-2*BTU Output:8,000 - 30,000 / hrType:Solid Fuel Room Heater/Pellet TypeHeating Capacity:up to 1,500 sq. ft.Standard:ASTM E1509 and ULC/ORD-C1482Room Heater Pellet Fuel Burning typeand (UM) 84-HUD, Mobile HomeApproved.Hopper Capacity:52 lbsB. Mobile Home ApprovedThis appliance is approved for mobile home installationswhen not installed in a sleeping room and when an outsidecombustion air inlet is provided. The structural integrity ofthe mobile home floor, ceiling, and walls must be maintained.The appliance must be properly grounded to the frame ofthe mobile home and use only listed pellet vent Class “L” or“PL” connector pipe. A Quadra-Fire Outside Air Kit must beinstalled in a mobile home installation.Fuel:Wood Pellets or Shelled CornShipping Weight:240 lbs*BTU output will vary, depending on the brand of fuel youuse in your stove. Consult your Quadra-Fire dealer forbest results.NOTE: Hearth & Home Technologies, manufacturer ofthis appliance, reserves the right to alter its products,their specifications and/or price without notice.C. Glass SpecificationsThis appliance is equipped with 5mm ceramic glass. Replaceglass only with 5mm ceramic glass. Please contact yourdealer for replacement glass.NOTE: This installation must conform with local codes.In the absence of local codes you must comply with theASTM E1509, (UM) 84-HUD, ULC/ORD-C-1482D. Electrical Rating115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 AmpsPage 47001-142CNovember 2, 2005

Santa Fe Pellet Stove2RRGetting StartedA. Design, Installation & LocationConsiderationsB. Fire Safety1. Appliance LocationConsideration must be given to safety, convenience, trafficflow, and the fact that the appliance will need a chimney andchimney connector. It is a good idea to plan your installationon paper, using exact measurements for clearances andfloor protection, before actually beginning the installation. Ifyou are not using an existing chimney, place the appliancewhere there will be a clear passage for a factory-built listedchimney through the ceiling and roof.Check with your local building code agency before youbegin your installation. Be sure local building codes do notsupersede UL specifications and always obtain a buildingpermit so that insurance protection benefits cannot beunexpectedly cancelled. If any assistance is required duringinstallation, please contact your local dealer.We recommend that a qualified building inspector and yourinsurance company representative review your plans beforeand after installation.Maintain the designated clearances to combustibles.Insulation must not touch the chimney. You must maintainthe designated air space clearance around the chimney.This space around a chimney is necessary to allownatural heat removal from the area. Insulation in thisspace will cause a heat buildup, which may ignite woodframing. NOTE: Clearances may only be reduced bymeans approved by the regulatory authority havingjurisdiction.To provide reasonable fire safety, the following should begiven serious consideration:1.Install at least one smoke detector on each floor ofyour home to ensure your safety. They should belocated away from the heating appliance and closeto the sleeping areas. Follow the smoke detectormanufacturer’s placement and installation instructions,and be sure to maintain regularly.2.A conveniently located Class A fire extinguisherto contend with small fires resulting from burningembers.3.A practiced evacuation plan, consisting of at least2 escape routes.4.A plan to deal with a hopper fire as follows:2. Thermostat LocationThe thermostat’s location will have some effect on theappliance’s operation. When the thermostat is located closeto the appliance, it may require a slightly higher temperaturesetting to keep the rest of the house comfortable. If thethermostat location is in an adjacent room or on a differentfloor level, you will notice higher temperatures near theappliance.In the event of a hopper fire:A.B.C.D.E.CAUTIONNotify fire departmentPrepare occupants for immediate evacuation.Close all openings into the appliance.While awaiting fire department, watch for ignitionof adjacent combustibles from overheated ventpipe, hot embers or sparks from the chimney.Pour a bucket of water into the appliancehopper.WARNING Do NOT connect this unit to a chimney flue servicinganother appliance. Do NOT connect to any air distributon duct or system.Fire Hazard. November 2, 20057001-142CDo not operate appliance before readingand understanding operating instructions.Failure to operate appliance properly maycause a house fire.Page 5

Santa Fe Pellet StoveRE. Inspect Appliance & Components andPre-Use Check ListC. Tools And Supplies NeededTools and building supplies normally requiredfor installation, unless installing into an existingmasonry fireplace:Reciprocating SawSafety GlassesChannel LocksFraming SquareHammerElectric Drill & Bits (1/4”)Phillips Screwdriver1/4” Self-Tapping ScrewsTape MeausrePlumb LineMay also need:LevelVent Support StrapsFraming MaterialVenting PaintHi-temp Caulking MaterialGlovesD. Measuring Standards1. Pipe measurements are from center line to center line.1.Place the appliance in a location near thefinal installation area and follow the procedures below:2.Open the appliance and remove all the partsand articles packed inside the ComponentPack. Inspect all the parts and glass for shipping damage. Contact your dealer if any irregularities are noticed.3.All safety warnings have been read and followed.4.This Owner’s Manual has been read.5.Floor protection requirements have been met.6.Venting is properly installed.7.The proper clearances from the appliance andchimney to combustible materials have beenmet.8.The masonry chimney is inspected by a professional and is clean, or the factory built metalchimney is installed according to the manufacturer’s instructions and clearances.9.The chimney meets the required minimumheight.10.All labels have been removed from the glassdoor.11.Plated surfaces have been wiped clean, ifapplicable.12.Thermostat or remote has been installed.13.A power outlet is available nearby.2. Vertial terminations are measured to top of pipe.Measure verticalclearances fromthis surfaceMeasure horizontalclearances fromthis surfaceWARNINGHearth & Home Technologies disclaims anyresponsibility for, and the warranty will bevoided by, the following actions:Figure 6.1WARNINGInspect appliance and components fordamage. Damaged parts may impair safeoperation. Do NOT install damaged components. Do NOT install incomplete components. Do NOT install substitute components.Report damaged parts to dealer.Page 6 Installation and use of any damaged appliance. Modification of the appliance. Installation other than as instructed by Hearth & HomeTechnologies. Installation and/or use of any component part not approvedby Hearth & Home Technologies. Operating appliance without fully assembling allcomponents. Operating appliance without legs attached (if suppliedwith unit). Do NOT Overfire Or any such action that may cause a fire hazard.7001-142CNovember 2, 2005

Santa Fe Pellet StoveRR3Dimensions and ClearancesA. Appliance Dimensions25-7/16 in.(705 mm)12-11/16 in.(322mm)27-3/4 in.CL(705mm)28-5/8 in.with base21-3/16 in.(727mm withbase)(538mm)Figure 7.1 - Top ViewFigure 7.2- Front View28-3/16 in (716mm)25-13/16 in (655mm)3-7/8 in(98mm)2-5/8 in(66mm)CLCL16-7/16 in.CL(418mm)17-5/16 in.with base26-7/16 in(672mm)(440mm)Figure 7.3 -Side ViewNovember 2, 200528-9/16 in(726mm)Figure 7.4 - Side View with Top Vent Adapter7001-142CPage 7

Santa Fe Pellet StoveRB. Clearances to Combustibles (UL and ULC)Alcove InstallationACBInchesMillimetersMinimum Alcove Height431092Minimum Alcove Side Wall6152Minimum Alcove Width38965Maximum Alcove Depth36914CIStraight Back AgainstWallA Back Wall to ApplianceB Side Wall to ApplianceInchesMillimeters2516152Corner InstallationC Walls to ApplianceInchesMillimeters251JCLDimension to CornerI Flue Center LineJ Back of Top Vent ions with:3 to 3 inch Top Vent Adapter and3 to 6 inch Offset Adapter KitFDGWARNINGHFire Risk.Comply with all minimum clearances tocombustibles as specified.HEFailure to comply may cause house fire.GVertical InstallationD Back Wall to Flue PipeSide Wall to Cast TopEBack Wall to ApplianceFInchesMillimeters37661527178Corner InstallationG Walls to ApplianceH Side Wall to Flue PipeInchesMillimeters251376Page 8NOTE: Illustrations reflect typical installations and are FORDESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual designpreference.7001-142CNovember 2, 2005

Santa Fe Pellet StoveRRC. Hearth Pad Requirements (UL and ULC)Use a nonco

Nov 02, 2005 · SANTA FE PELLET STOVE Owner’s Manual Installation and Operation SANTAFE-B1 . Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home . ASTM E1509, ORD-C-1482-M199 0 Room Heating Pellet Burning Type, APFI, (UM) 84-HUD FOR USE ONLYWITHPELLETIZED WOOD

Related Documents:

Santa Fe Pellet Stove R R R 1 Listing and Code Approvals Model: Santa Fe Pellet Stove Laboratory: OMNI Test Laboratories, Inc. Report No. 061-S-53-2 Type: Solid Fuel Room Heater/Pellet Type Standard: ASTM E1509 and ULC/ORD-C1482 Room Heater Pellet Fuel Burning type and (UM) 84-HUD, Mobile Home Approved. A. Appliance Certification C. Glass .

electricity for ignition and stove operation is a disadvantage of pellet stoves especially with regard to fail-proof and independent heating systems. In order to enable the operation of a pellet stove without electric grid connection, a new micro CHP technology for a pellet stove based on a thermoelectric generator has been developed. 3

When first operating the pellet stove, switch it to manual mode, so you can have full control of the pellet stoves control board functions and familiarize yourself with how the pellet stove works. It is in this mode that the heat level for the AUTO and T-STAT mode is set. To Start up a Cold Stove Press and release the On/Off button.File Size: 930KB

of burning pellet fuel. PELLETS This pellet stove is designed and approved to burn wood pellets, that comply with pellet fuels industry standards. Minimum of 40 lbs. density per cubic feet, 1/4 to 5/16 in diameter, with a maximum length of 1-1/2, and less than 1% ash. Pellet fuel

Paladin pellet mill Paladin 600 Paladin 1600 02. 03 Paladin 1600 ES Paladin 2000 Paladin 3000 Paladin pellet mill series. Features that make the difference 1 3 2 . Paladin pellet mill, Paladin, andritz pellet mill, feed pelleting, pelleting, pelletizer, andritz pellet Created Date:

OWNER’S MANUAL Freestanding and Fireplace Insert . Insert: The rating label is located on the hopper cover. PeLLet QuaLity: Pellet quality is important, please read the following: Your Hudson River pellet stove has been designed to burn wood pellets only. Do not use any other type of fuel

this pellet fuel burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. . FUEL: This pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty fuel

Using this API you could probably also change the normal Apache behavior (e.g. invoking some hooks earlier than normal, or later), but before doing that you will probably need to spend some time reading through the Apache C code. That’s why some of the methods in this document, point you to the specific functions in the Apache source code. If you just try to use the methods from this module .