Zimmer Nexgen Trabecular Metal Augments Arthrom-PDF Free Download

infection. Zimmer's Trabecular Metal revision augments and cones are manufactured from elemental tantalum. These augments and cones can be used in combination with Zimmer's Knee Revision Solutions, including the NexGen Legacy Constrained Condylar Knee (LCCK), that has demonstrated 96% survival at 10 years.* To find out even more, contact your

Zimmer Trabecular Metal Reverse Shoulder System, Base Plates and Humeral Stems Zimmer, Inc. K121543 Purpose and Device . Description: The proposed devices are a line extension of the . Zimmer Trabecular Metal Reverse Shoulder System, which consists of conventional (anatomic) and r

Zimmer Trabecular Metal . Trabecular Metal Reverse Insert standard 150 36 mm et 40 mm 3 épaisseurs : 0 mm, 3 mm, et 6 mm Insert

Trabecular Metal Evidence supporting Trabecular Metal acetabular components is well-documented across more than 300 publications. Trabecular Metal cups used in revision THA have shown to be 21% less likely to be re-revised due to infection and 11% less likely to be re-revised for any reason.11-13 porosity with Up to 80% 100%

the Zimmer NexGen Knee family of replacement knee joints: 1) the so-called “Flex” or . minimally invasive surgery technique (i.e., a much smaller incision). The NexGen MIS . Defendant Zimmer Orthopaedic Surgical Products, Inc. is a corporation organized and existing under the law

Zimmer Trabecular Metal Reverse Shoulder System surgical technique (Zimmer Item Number 97-4309-203-00). The PSI Shoulder Instrument Guides and Bone Model are patient speci

Trabecular Metal Glenoid not be used as component alignment with bony preparation is critical. Determining the Size of Trabecular Metal Glenoid Use the Glenoid Scraper and Glenoid Planer to remove any remaining cartilage and soft tissue from the glenoid. Use the Glenoid Centering Guides to determine which, if any, glenoid size (black 40mm,

Zimmer’s growth in the near term. That is especially true in our two largest product categories, knees and hips. In knees, growth will come from the Gender Solutions brand and our Zimmer NexGen LPS-Flex Mobile Knee, designed to accommodate an increased range of motion. The Zimmer M/L

Cone Surgical Technique. Trabecular Metal Cone Zimmer . In the NexGen Knee System, this also allows use of the next size larger femoral component, which has a larger A/

The FIT tibial tray accepts 5 and 10mm augments which are available in both 1/3 and 1/2 configurations. The tibial augments can be stacked up to 15mm if the defect requires a larger augment. The 5mm augments can be used on either side of the tray. The 10mm augments are side-specific due to the 15-degree taper designed to

Zimmer NexGen LCCK (97-5994-302-00) and RH Knee (97-5880-002-00) techniques. This Surgical Technique is intended to be an addendum to the Zimmer NexGen LCCK (97-5994-302-00) and RH Knee (97-5880-002-00) surgical techniques. TOC Zimmer Instrumentation

the available Zimmer PSI Knee kits. The pre-operative guide and instructions for use of the Zimmer PSI Knee Planner application are provided in the Zimmer PSI Knee Planner Software User Guide 97-5970-035-00. Indication for use The Zimmer PSI Knee System is indicated as an orthopedic instrument system to assist in the positioning of knee

The Zimmer PSI Knee System should not be used to perform surgical procedures other than those specified in this surgical technique. The Zimmer PSI Knee System should be used in conjunction with a femur first technique The Disposable Zimmer PSI Knee Instruments, including instrument guides and bone models are patient specific

Zimmer Pulsavac Plus Wound Debridement Family Brochure 97-5150-303-00 Author: Zimmer Inc Subject: Zimmer Pulsavac Plus Wound Debridement Family Product Information Keywords: Zimmer Pulsavac Plus Wound Debridement Family Brochure Created Date: 12/1/2008 3:06:45 PM .

Zimmer NexGen MIS LPS-Flex Mobile Implant System Surgical Technique Fig. 5 Surgical Technique Surgical technique is an important factor to consider when attempting to maximize range of motion in total knee arthroplasty. Close attention must be paid to balancing the flexion and extension gaps

Zimmer NexGen Complete Knee Solution LPS Surgical Technique 7 Place the Tibial Milling Depth Resection Guide onto the template. Adjust the Tibial Milling Base to the proper level (Fig. 11). Keep a finger on the

2 Zimmer NexGen Complete Knee Solution EM/IM Tibial Resector Surgical Technique Fig. 1 Extramedullary Technique Using the Spike Arm Step One Assemble Alignment Guide Slide the Ankle Clamp onto

INTRO Zimmer LCCK Revision Surgical Technique Introduction Tous les composants de la prothèse NexGen LCCK (Legacy Constrained Condylar Knee) peuvent être utilisés à la fois pour l’arthroplastie totale de genou de première intention et de révision (Fig. 1). L’instrumentation NexGe

Zimmer, Inc., called Trabecular Metal , or TM. TM has been used in a large number of orthopaedic implants since its inception in the early 1990’s by Ultramet, a research and development firm (Deglurkar et al., 2006). Due to its high porosity, Trabecular Metal is uniquely conducive to

Zimmer Trabecular Metal Femoral Cone Augment Surgical Technique Overview The objective of the Trabecular Metal Femoral Cone Augment is to fill and reconstruct large bone deficiencies and cavitary defects (Fig. 1) in the distal femur and to provide for a stable platform for an LCCK o

the Trabecular Metal Reverse Shoulder System in conjunction with the Bigliani/Flatow glenoid component allows the potential for the surgeon to restore the geometry of a normal joint, thus ensuring good motion and pain relief, as well as durability of the reconstru

Dec 15, 2018 · 4. Ashby chart comparing properties of cortical and trabecular bone with commonly used implant materials. Few materials are comparable to trabecular bone; however, porous PPP falls within the range and can be tailored to match various properties of trabecular bone. 5. Chemical structure of

implants were placed into trabecular bone in the metaphyseal region (femoral head core defect). These two studies reveal an important property of dibotermin alfa /ACS: when used to fill trabecular bone defects, resorption of surrounding trabecular bone is observed in the initial phase of healing.

psa revision knee zimmer-biomet persona revision knee zimmer-biomet nexgen legacy lcck revision knee zimmer-biomet vanguard revision knee depuy attune revision knee depuy lcs complete revision knee3 stryker triathlon smith & nephew legion revision knee medacta

The Zimmer Persona (Zimmer, Warsaw, IN, USA) design was born following the experience of the Insall-Burstein PS knee, which had a cam and post articulation at 60 of knee flexion and the NexGen Legacy (Zimmer, Warsaw, IN, USA), which showed initial cam-post engage-m

Zimmer Segmental System Surgical Technique Compatibility Some implants and provisional components from the Segmental Knee System are compatible with the Zimmer NexGen Rotating Hinge Knee and/or the Zimmer MOST Options System, and vice versa. However, some specific implants and provisional

Trabecular Metal material is made of tantalum, one of the most inert elemental metal biomaterials available. This material is not only biocompatible, but has a modulus of elasticity that is close to that of cancellous bone.1 Tivanium Ti-6al-4V alloy Substrate Tivanium Alloy provides excellent biocompatibility and strength without excessive .

00-6334-050-28 mgh constrained liner 50x28 zimmer ltd each zimmer ltd: 03/03/2014 each: 1 00-7711-011-00 orthopaedic contract m/l taper plasma sprayed stem size 11mm st. zimmer ltd: . 00-8775-009-32 orthopaedic contract biolox delta taper liner hh 32 zimmer

PSI Moisten, fold, seal and mail back. Customized instrumentation 3 visit zimmer.com Combining Zimmer Patient Specific Instruments with Zimmer’s wide range of knee shapes and sizes helps your surgeon give you the best possible fit and the best possible outcome. That’s why the knee with one of the lowest rates

Zimmer Biomet is committed to respecting the human rights, dignity and privacy of the individual. We follow applicable labor laws and do not allow Zimmer Biomet or its Business Partners to engage in child labor, forced labor or human trafficking. *Refers to full- and part-time employees of Zimmer Biomet.

Surgical Technique for Gender Solutions Natural-Knee Flex Knee INTRO.1 Introduction General Considerations Zimmer PSI is not designed for use with the Zimmer MIS Quad-Sparing Total Knee Procedure. Zimmer PSI should be used in conjunction with a femur first technique. Verify stability and fixation of all pins. When securing the

ZIMMER GmbH Technische Werkstätten Im Salmenkopf 5 D-77866 Rheinau-Freistett Contact 0303G00K Phon: 49.7844.9138- Fax: 49.7844.9138-80 www.zimmer-gmbh.com info@zimmer-gmbh.com ZIMMER Clamping and braking elements for linear guides 0303E00K Clamping and braking elements for linear guides Map Hamburg Bonn Frankfurt Basle Stuttgart Berlin

On-Demand courses at Zimmer Biomet support and reinforce the Zimmer Biomet Values. Employees at all levels are expected to demonstrate behaviors and characteristics associated with each: Customers First, Do the Right Thing, Innovate and Improve, Win Through Results, Positive Culture, and One Zimmer Biomet. Customers First

Hans Zimmer Percussion (HZ, AE).nki is your "all-in-one" patch containing everything but the Timpani with the most popular hits and techniques already mapped and Hans Zimmer Timpani (HZ, AE).nki is a deeply sampled timpani which has two handed mapping enabled by default. If you double-click the Hans Zimmer Presets folder you will

Information about other Zimmer Biomet benefits, plan operation and adminis tration, and legal requirements. We encourage you to read both SPDs carefully to understand how your medical benefits work so you can make the best use of them. Note: This Zimmer Biomet medical plan is part of the Zimmer Biomet Holdings, Inc. Health and Welfare Plan.

Oct 10, 2017 · Zimmer, Inc NexGen CR knee K933785 30/01/1995 NexGen ( CR) - Flex Femoral components K023211 17/10/2002 Otis Biotech MultiFitM Total Hip System (Instruments & Sterilization ) K101472 05/01/2011 ULC spinal pedicl e screw system (Instruments only ) K083077 26/10/2009 4. Device Description

jects received the Zimmer NexGen High-Flex Gender Solutions knee prosthesis. Of the 97 knees, the first 39 TKAs with follow-up data through one year were included in the analysis to yield equal group sizes. A total of 28 of these gender specific implants were Nex-Gen CR-Flex, while the remaining 11 were NexGen LPS-Flex.

A More Natural Pivot/Rotation The central location of the RH Knee hinge mechanism is placed closer to the axis of the tibial component, resulting in more natural and consistent tibiofemoral kinematics when compared to posterior hinge knee designs. The rotation of the NexGen RH

The NexGen CR-Flex Fixed Bearing Knee is a cruciate retaining prosthesis designed to safely accommodate greater range of motion for cultural, recreational, or work activities that require deep flexion. The development of the CR-Flex Fixed Bearing Knee is the result of an analysis of the normal knee prosthesis as it undergoes deep flexion beyond .

Revision Trabecular Metal Cones provide customers a solution to effectively fill bone defects to closely replicate patients normal anatomy. The proven2-4 Trabecular Metal material offers increased biological fixation and distributes loads closer to the joint line. Anatomic shapes designed to fill bone voids without cortical impingement22