TraumaOne LORENZ PLATING SYSTEM

One Surgeon. One Patient .Over 1 million times per year, Biomet helps one surgeon providepersonalized care to one patient.The science and art of medical care is to provide the right solutionfor each individual patient. This requires clinical mastery, a humanconnection between the surgeon and the patient, and the righttools for each situation.At Biomet, we strive to view our work through the eyes of one surgeonand one patient. We treat every solution we provide as if it’s meantfor a family member.Our approach to innovation creates real solutions that assist eachsurgeon in the delivery of durable personalized care to each patient,whether that solution requires a minimall-invasive surgical technique,advanced biomaterials, or a custom, patient-matched implant.When one surgeon connects with one patient to provide personalizedcare, the promise of medicine is fulfilled.ComprehensiveOne set contains all implants and instrumentation

TraumaOne LORENZ PLATING SYSTEMStreamlinedDedicated plate and screw implant containersMidface Plate ContainerMandible Screw ContainerMandible Plate ContainerCustomizableExtra container pockets and specialized areas for set customization

MIDFACE PLATES 1.5MMREGULAR PLATES – SILVERGRADE II TITANIUM, 0.6MM2x3 Matrix Plate Rectangle01-71362x4 Matrix Plate Rectangle01-71372-Hole Straight Plate, Medium01-73452-Hole Straight Plate, Long01-73474-Hole Straight Plate, Regular01-70404-Hole Straight Plate, Medium01-70454-Hole Straight Plate, Long01-70476-Hole Straight Plate, Regular01-70506-Hole Straight Plate, Long01-70578-Hole Straight Plate, Regular01-706216-Hole Straight Plate, Regular01-70666-Hole Orbital Plate, Curved01-71268-Hole Orbital Plate, Curved01-712810-Hole Orbital Plate, Curved01-71302x2 L Plate Left, Regular01-70702x2 L Plate Right, Regular01-70712x2 L Plate Left, Medium01-70742x2 L Plate Right, Medium01-70752x2 L Plate Left, Long01-70782x2 L Plate Right, Long01-70793x3 L Plate, 100 Left, Medium01-70323x3 L Plate, 100 Right, Medium01-70333x3 L Plate, 100 Left, X-Long01-70363x3 L Plate, 100 Right, X-Long01-7037Items not to scale

MIDFACE PLATES 1.5MMREGULAR PLATES – SILVERGRADE II TITANIUM, 0.6MM4x6 L Plate Left, Long01-70384x6 L Plate Right, Long01-70392x2 Z Plate Left, Medium01-70852x2 Z Plate Right, Medium01-70863x3 T Plate, Regular01-70905-Hole Y Plate, Regular01-71005-Hole Y Plate, Long01-71025-Hole Y-Plate, X-Long01-71046-Hole Double Y Plate, Regular01-71106-Hole Double Y Plate, Long01-71126-Hole Double Y Plate, X-Long01-7114ORBITAL PLATES – GREEN4-Hole Orbital Plate, HX01-7123GRADE IV TITANIUM, 0.5MM6-Hole Orbital Plate, Curved HX01-712118-Hole Orbital Plate, HX01-7122RIGID PLATES – GOLD6-Hole Straight Plate HXSP-2371GRADE IV TITANIUM, 0.6MM14-Hole Plate, Curved01-86894-Hole Straight Plate01-866420-Hole Straight Plate01-86708-Hole Straight Plate01-86622x2 L Plate Left, Long01-86782x2 L Plate Right, Long01-86793x3 L Plate Left, MediumSP-25753x3 L Plate Right, MediumSP-2576Items not to scale

MIDFACE PLATES 1.5MMRIGID PLATES – GOLDGRADE IV TITANIUM, 0.6MM3x3 L Plate Left, Long01-86363x3 L Plate Right, Long01-86374x6 L Plate Left, Long01-86805-Hole Y Plate, X-long01-86046-Hole Double Y Plate, RegularSP-26186-Hole Double Y Plate, X-LongSP-26194x6 L Plate Right, Long01-8681ORBITAL FLOOR PLATES0.2mm Orbital Floor MeshSP-1865Pre-formed Orbital Floor PlateSmall, 0.3mm01-7106Pre-formed Orbital Floor PlateMedium, 0.3mm01-7107Pre-formed Orbital Floor PlateLarge, 0.3mm01-7108Pre-formed N.O.E., 0.3mm Plate01-7109MESH PANEL– SILVERRegular Grid Panel0.6mm Thickness80mm x 53mm01-7180Items not to scaleSmall Grid Panel0.6mm Thickness85mm x 53mm01-7182Small Grid Panel0.3mm Thickness85mm x 53mm01-71851.0/1.5mm Titanium Hex Panel0.2mm Thickness85x50mm01-7340

MIDFACE PLATES 1.5MMSCREWS1.5mm HT X-Drive Screws - Green1.5mm Self-Tapping Screws - GoldPart #DescriptionPart #Description95-61031.5 x 3.5mm HT X-Drive Self-Drilling95-15031.5 x 3.5mm HT X-Drive95-61041.5 x 4mm HT X-Drive Self-Drilling95-15041.5 x 4mm HT X-Drive95-61051.5 x 5mm HT X-Drive Self-Drilling95-15051.5 x 5mm HT X-Drive95-6105x1.65 x 5mm HT X-Drive Self-Drilling95-15061.5 x 6mm HT X-Drive95-61061.5 x 6mm HT X-Drive Self-Drilling95-15071.5 x 7mm HT X-Drive95-6106x1.65 x 6mm HT X-Drive Self-Drilling95-15081.5 x 8mm HT X-Drive95-61071.5 x 7mm HT X-Drive Self-Drilling95-15091.5 x 9mm HT X-Drive95-15111.5 x 11mm HT X-Drive95-15131.5 x 13mm HT X-Drive95-15151.5 x 15mm HT X-Drive91-xxxx for single screws1.8mm Self-Tapping EmergencyScrews - MagentaPart #Description95-18031.8 x 3.5 HT X-Drive Emergency95-18051.8 x 5 HT X-Drive Emergency95-18071.8 x 7 HT X-Drive Emergency95-18091.8 x 9 HT X-Drive Emergency91-xxxx for single screws91-xxxx for single screwsBLADES/DRILLSBONE REDUCTION BLADES1.5 x 5mmBone Reduction BladeSP-18882.0 x 7mmBone Reduction BladeSP-1889BLADESHT X-Lock Short Blade15-1194HT X-Lock Standard Blade15-1196TWIST DRILLS2.5 x 6mm SD Mod Byrd ScrewSP-2032Carroll-Girard Screw, Hex EndSP-26931.1 x 50mm, 5mm Stop01-71421.1 x 50mm, 7mm Stop01-71441.1 x 50mm, 9mm Stop01-71461.1 x 50mm, 15mm Stop01-7148Items not to scale

MANDIBLE PLATES 2.0/2.3MMPLATES – SILVERGRADE II TITANIUM, 1.0MM2x7 Matrix Plate, Straight42-10052x7 Matrix Plate, Curved42-10064-Hole StraightSP-22844-Hole Straight Plate with Gap42-10044-Hole Straight Plate, Long GapSP-23754-Hole Straight Plate, X-Long GapSP-23767-Hole Straight Plate42-100710-Hole Straight PlateSP-225616-Hole Straight Plate42-10166-Hole Y Plate, Long42-10027-Hole Plate, Curved42-10037-Hole Double Y PlateSP-26656-Hole Double Y Plate, SmallSP-2705PLATES – GOLDGRADE II TITANIUM, 1.6MM2x7 Matrix Plate, StraightSP-26302x7 Matrix Plate, CurvedSP-26316-Hole Straight Plate with GapSP-27037-Hole Straight Plate43-1007Items not to scale4-Hole Straight Plate43-10054-Hole Straight Plate with Gap43-100416-Hole Straight Plate43-1016

MANDIBLE PLATES 2.0/2.3MMPLATES – GOLDGRADE II TITANIUM, 1.6MMLong Y PlateSP-24657-Hole Plate, Curved43-1008PLATES – BLUEAngle Plate, Small43-1001GRADE IV TITANIUM, 2.0MM4-Hole Plate with GapSP-22926-Hole Straight PlateSP-25666-Hole Plate with GapSP-237724-Hole Straight Plate44-102412-Hole Straight Plate44-1012Double Angle Plate, Small44-1002Double Angle Plate, Medium44-1003(pictured)Angle Plate, Large44-1001Double Angle Plate, Straight, Small44-1018Double Angle Plate, Straight, Medium44-1022(pictured)Angle Plate, Straight, Large44-1021Items not to scale

MANDIBLE PLATES 2.0/2.3MMPLATES – MAGENTAGRADE II TITANIUM, 2.6MM16-Hole Straight PlateSP-24697-Hole Plate, CurvedSP-24707-Hole Straight PlateSP-2468Angle Plate, SmallSP-2467Double Angle Plate, SmallSP-2276 (pictured)Double Angle Plate, MediumSP-2277Angle Plate, Large44-1005Angle Plate, Straight, Large44-1023PLATE TEMPLATESSmall Double Angle Template46-1002T (pictured)Medium Double Angle Template46-1003TLarge Angle Template46-1001TSmall Double Angle Straight Template46-1018TItems not to scaleMedium Double Angle Straight Template46-1022T (pictured)

MANDIBLE PLATES 2.0/2.3MMPLATE TEMPLATES24-Hole Straight Template46-1024TLarge Angle Straight Template46-1021TSPECIALTY ITEMS2.0/0.6mm 4-HoleStraight PlateSP-25851.2mm9-Hole Straight, WideSP-24022.0/0.6mm 4-HoleCompression PlateSP-21941.0mm 4 HoleCompression PlateSP-2397Large Angle Plate, 2.8mmSP-2623Recon Add-On Condyle, Left*01-2691Recon Add-On Condyle, Right*01-2692TraumaOne 2.3mm TapSP-2258*Use with 2.0 (Blue)/2.6 (Magenta) profile plates. Implantable for one year.SCREWS2.0mm X-Drive Non-Locking Screws2.0mm X-Drive Locking ScrewsPart #DescriptionPart #Description41-22052.0 x 5mm Self-Drilling41-21062.0 x 6mm X-Drive Locking41-22072.0 x 7mm Self-Drilling41-21082.0 x 8mm X-Drive Locking41-21102.0 x 10mm X-Drive Locking41-20052.0 x 5mm X-Drive41-21122.0 x 12mm X-Drive Locking41-20062.0 x 6mm X-Drive41-21142.0 x 14mm X-Drive Locking41-20082.0 x 8mm X-Drive41-21162.0 x 16mm X-Drive Locking41-20102.0 x 10mm X-Drive41-21182.0 x 18mm X-Drive Locking41-20122.0 x 12mm X-Drive41-20142.0 x 14mm X-Drive41-20162.0 x 16mm X-Drive41-20182.0 x 18mm X-DriveItems not to scale

MANDIBLE PLATES 2.0/2.3MMSCREWS2.3mm X-Drive Non-Locking Screws2.3mm X-Drive Locking ScrewsPart #DescriptionPart #Description41-23052.3 x 5mm X-Drive41-24062.3 x 6mm X-Drive Locking41-23062.3 x 6mm X-Drive41-24082.3 x 8mm X-Drive Locking41-23082.3 x 8mm X-Drive41-24102.3 x 10mm X-Drive Locking41-23102.3 x 10mm X-Drive41-24122.3 x 12mm X-Drive Locking41-23122.3 x 12mm X-Drive41-24142.3 x 14mm X-Drive Locking41-23142.3 x 14mm X-Drive41-24162.3 x 16mm X-Drive Locking41-23162.3 x 16mm X-Drive41-24182.3 x 18mm X-Drive Locking41-23182.3 x 18mm X-Drive2.7mm X-Drive Non-Locking Screws2.0mm Self-Drilling IMF ScrewsPart #DescriptionPart #Description41-27082.7 x 8mm X-Drive Emergency91-56072.0 x 7mm Self-Drilling IMF41-27102.7 x 10mm X-Drive Emergency91-56092.0 x 9mm Self-Drilling IMF41-27122.7 x 12mm X-Drive Emergency91-56112.0 x 11mm Self-Drilling IMF41-27142.7 x 14mm X-Drive Emergency41-27162.7 x 16mm X-Drive Emergency41-27182.7 x 18mm X-Drive EmergencyDRILLS1.5x50mm, 5mm Stop01-9192(pictured)1.5x50mm, 7mm Stop01-91931.6x50mm, 22mm Stop46-10061.6x115mm, 26mm Stop46-10071.6mm Quick Connect Twist DrillSP-27211.8x50mm Drill, 26mm Stop24-20501.8x115mm, 26mm Stop46-10041.8mm Quick Connect Twist DrillSP-2722 (pictured)BLADESTRAUMAONE IMF BLADETraumaOne Blade, Cross-Drive46-1005Items not to scaleTraumaOne Blade, IMF46-0011

INSTRUMENTATIONMIDFACEGreen 1.5/2.0 Handle01-7390Plate HoldingWand01-71863-Prong Plate Bender01-7167Beuse PlateHolding Forceps01-9095Plate Bending Pliers01-9728T-Handle*46-0016*For bone reduction bladesPlate/Wire Cutter01-7172Fernandes OrbitalRetractorSP-2243Items not to scale

INSTRUMENTATIONMANDIBLEPlate Bender46-0001Plate Holding Forceps46-0005Items not to scalePlate Cutter46-0002Drill Guide with Handle46-0006Bone Reduction Forceps46-0004Depth Gauge01-9125Bending Pliers46-0009

INSTRUMENTATIONMANDIBLETrocar Handle46-0012Racheting Screw Driver46-0008Non-Racheting Screw Driver46-0007 (pictured)Trocar46-0013Drill Guide46-0015Cheek Retractor46-0014Plate Deburr Diamond,J-notch01-2788Full GuardSP-2244Fiber Optic Cable, 10ft*01-0371*Equiped with ACMI fitting for lightsourceItems not to scale

INSTRUMENTATIONMANDIBLEPlate/Screw Containers Designed to Fit into Standard TraumaOne ContainerTraumaOne Outer Container and Inner Instrument Tray*46-1500Mandible Plate Container46-1504*Containers and instruments not includedItems not to scaleMidface Screw Container46-1501IMF Implant ContainerSP-2462Midface Plate Container46-1502Mandible Fracture Plate ContainerSP-2641Mandible Screw Container46-1503Mandible Reconstruction Plate ContainerSP-2642

INSTRUMENTATIONMANDIBLEPlate/Screw Containers Designed to Fit into Aesculap ContainersTraumaOne Midface Aesculap Outer Container46-1610Midface Screw Container46-1601TraumaOne Midface Insert Tray46-1611Midface Plate Container46-1602TraumaOne Mandible Aesculap Outer Container46-1620Mandible Screw Container46-1603TraumaOne Mandible Insert Tray46-1621Mandible Plate Container46-1604Items not to scale

What fascinates you about the body is also what drives us. That’s why we’re alwayspushing the boundaries of engineering to make products that help you keep thehuman form as glorious as it was intended. To learn more about our breadth ofproducts, call 800-874-7711 or visit us online at biometmicrofixation.com.We’d love to join you in a conversation about the future.For more information on TraumaOneTM, please contact us at:GLOBAL HEADQUARTERS1520 Tradeport Drive Jacksonville, FL 32218-2480Tel (904) 741-4400 Toll-Free (800) 874-7711 Fax (904) 741-4500 Order Fax (904) nring 600 3316 LC Dordrecht The NetherlandsTel 31 78 629 29 10 Fax 31 78 629 29 12As the manufacturer of this device, Biomet Microfixation does not practice medicine and does not recommend this product for use on a specific patient. The surgeon who performs any implant procedure must determinethe appropriate device and surgical procedure for each individual patient. Devices shown in this brochure may not be cleared or licensed for use or sale in your individual country. Please contact your local distributor forinformation regarding availability of these products. Information contained in this brochure is intended for surgeon or distributor information only and is not intended for patient distribution. All surgeries carry risks. Foradditional information, including indications, risks and warnings please see appropriate package insert or visit our web site at www.biometmicrofixation.com or call 1.800.874.7711Aesculap is a registered trademark of Aesculap Aktiengesellschaft.TraumaOne is a trademark of Biomet 2011 Biomet Microfixation www.biometmicrofixation.comForm No. BMF00-3390 Rev 03k1106

2x7 Matrix Plate, Straight SP-2630 2x7 Matrix Plate, Curved SP-2631 4-Hole Straight Plate 43-1005 6-Hole Straight Plate with Gap SP-2703 7-Hole Straight Plate 43-1007 16-Hole Straight Plate 43-1016 16-Hole Straight Plate 42-1016. PLATES – SILVER. 6-Hole Double Y Plate, Small SP-2705. MANDIBLE

Related Documents:

Iron, zinc plating 2 E3C-S50 (8) E39-L40 Iron, zinc plating 1 Phillips screws M4 25 (with spring and plain washers) Iron, zinc plating 2 E3JK Nuts M4 Iron, zinc plating 2 E39-L41 Iron, zinc plating 2 Phillips screws M3 14 (with spring washers) Iron, zinc plating 4 6 E3C-1 (10) Plain washer M3 Iron, zinc plating 4 E39-L42 Iron, black coating 2

Zimmer Pulsavac Plus Wound Debridement Family Brochure 97-5150-303-00 Author: Zimmer Inc Subject: Zimmer Pulsavac Plus Wound Debridement Family Product Information Keywords: Zimmer Pulsavac Plus Wound Debridement Family Brochure Created Date: 12/1/2008 3:06:45 PM .

PLATING INCONSISTENCIES include variations in plating thickness, degree of oxide contamination in the plating and the type of plating. Proper control of workpiece plating reduces the chance of weak or inconsistent welds and/or electrode sparking or sticking to the workpieces. Electroplating is much preferred over electroless plating.

PLATING INCONSISTENCIES include variations in plating thickness, degree of oxide contami-nation in the plating and the type of plating. Proper control of workpiece plating reduces the chance of weak or inconsistent welds and/or electrode sparking or sticking to the workpieces. Electroplating is much preferred over electroless plating.

the available Zimmer PSI Knee kits. The pre-operative guide and instructions for use of the Zimmer PSI Knee Planner application are provided in the Zimmer PSI Knee Planner Software User Guide 97-5970-035-00. Indication for use The Zimmer PSI Knee System is indicated as an orthopedic instrument system to assist in the positioning of knee

The Zimmer PSI Knee System should not be used to perform surgical procedures other than those specified in this surgical technique. The Zimmer PSI Knee System should be used in conjunction with a femur first technique The Disposable Zimmer PSI Knee Instruments, including instrument guides and bone models are patient specific

Zimmer MotionLoc Screw for the Periarticular Locking Plate System Zimmer MotionLoc Screw for the Periarticular Locking Plate System 5 Reducing Stiffness of Locked Plating Constructs MotionLoc Screws reduce the locked plating construct stiffness by more than 58% while retaining construct strength.3 The stiffness reduction through the screws .

is produced to comply with ASTM C167-64, the "Standard Test Method for Thickness and Density of Blanket- or Batt-Type Thermal Insulating Material". Wool fiberglass insulation production lines usually consist of the following processes: (1) preparation of molten glass, (2) formation of fibers into a wool fiberglass mat, (3) curing the binder-coated fiberglass mat, (4) cooling the mat, and (5 .