Choose Thomas & Betts and connectto the power you need.For over 100 years, Thomas & Betts has successfully applied innovativedesign and manufacturing techniques to meet the changing needs of themarketplace. Today, we offer more than 100,000 electrical componentsand systems to terminate, connect, fasten, protect and identify wires,components and raceway. Our vast offering makes us one of the largestand best sources of electrical components in North America.Renewable EnergyAt T&B, we’re committed to: Products which provide solutions to your electrical needs Convenience of single-order, single-shipmentto your site for thousands of stocking items Expert local point of contact for clear, consistentinformation regarding training, codes and standards Quality brands that have proven themselves over time Inventive design and manufacture of problem-solving products Offering a best-of-class warranty and returns policyPower Generation Uniform carton labeling with additional bar-codingfor convenient inventory management Nationwide network of stocking electrical distributors Outstanding customer service capability Supplying you with the right products, convenientpackaging, on-time delivery and competitive pricingWe deliver the solutions that make your job easier and offer the power to bringit all together in one package. Call us today and let us help you profit fromsourcing your electrical products from the leader, Thomas & Betts.Transmission and Distribution

T&B ServicesCustomer Service1-800-816-7809Immediate, Knowledgeable AssistanceEvery Thomas & Betts Customer Service Representative is right where the actionis — surrounded by all the support and information they need to answer yourquestions and fill your orders faster than ever. Your calls and faxes are automaticallyrouted to Customer Service Specialists who personally serve your account and cananswer questions about products, order status, price and availability, and otherservice-related inquiries.Phone: 1-800-816-7809Fax: 1-800-816-7810Email: generalcustomerserviceteam@tnb.comTechnical Services1-888-862-3289Over 170 Years of Industry ExperienceMeeting and exceeding our customers’ expectations is a fundamental goal of Thomas& Betts. Call our Technical Services Department and talk LIVE to an expert who’llanswer questions and concerns regarding all aspects of our products and services.Our experienced and knowledgeable staff is second to none in the industry!Tool Services1-800-284-TOOLQuality You Can TrustTrust T&B’s dedicated Tool Services Department to answer all questionsregarding tool applications, repair, warranties, sales/lease/rental and technicalinformation. Ask about our specialized services, including customer/sales training,demos and calibration/certification of tools.www.tnb.comUnited StatesTel: 901.252.8000800.816.7809Fax: 901.252.1354Technical ServicesTel: 888.862.3289i

T&B Online SupportT&B Access tnbaccess.tnb.comT&B Access is a global sales tool for our distributor partners, offering: Quote RequestsStock ChecksPricing InquiriesCross ReferenceOrder EntryOrder ResolutionShipping StatusDocument Look-UpAutomatic Order ReceivingItem History Search Multiple-Location User SearchContext-Sensitive HelpShipping ConfirmationsTracking DataExpeditingReturns ProcessingQuality IssuesCustomer Report CardsWeb Catalog Look-UpAll of these tools and more are available online 24 hours a day – 7 days a week,without having to make a single phone call. Multi-lingual options are available in English,French and Spanish. T&B Access now serves over 10,000 satisfied customer usersat over 3,500 locations every month.Web Catalogwww.tnb.com/webcatalogThousands of Products at Your FingertipsU.S. contractors and specifiers have made our web catalog their numberone stop. Users can search for technical information by catalog number,UPC code, competitor number, keyword search, product category and/orbrand. Having found the item(s) they are searching for, they can then useour Where To Buy function to locate a T&B local distributor and/or othersupport services.iiUnited StatesTel: 901.252.8000800.816.7809Fax: 901.252.1354Technical ServicesTel: 888.862.3289www.tnb.com

In this section.ElastimoldUndergroundCable Accessories Elastimold Underground Cable AccessoriesOverview.2–3200-Amp Loadbreak Elbows.4–7200-Amp Deadbreak Elbows.8–9600-Amp Elbow Connectors. 10-21600-Amp Separable Cable Joints. 22-23Multi-Point Junctions. 24-25ComboT Integral Separable Connectors. 26-30Permanent Distribution Cable Joints. 34-35Shrink-Fit Cable Joints. 31-33Distribution Shrink-Fit Terminations. 36-42Pre-Molded Terminations.43Cable Shield Adapters and Jacket Seals. 44-45Equipment Bushings.46Medium-Voltage Cable AccessoriesTechnical Information. 47-52Shielded Surge Arresters. 53-59Transmission Cable Joints. 60-63Transmission Cable Terminations. 64-65Transmission Cable Accessories Installation Tools.66Transmission Cable Accessories Technical Information.67L-Kits and Vault Stretcher Kits Ordering Information.68

Power & High Voltage — Elastimold Underground Cable AccessoriesOverviewElastimold Separable Connectors, Cable Joints, Cable Terminatorsand other cable accessory products have been designed and tested perapplicable portions of IEEE, ANSI and other industry standards including:Switching and Fault Close Ratings IEEE 386 Standard for Separable Connectors 1ø and 3ø circuits 8.3kV lineto ground, 14.4kV max. across15kVopen contactsCLASSRATINGS 10 loadmake/break operationsat 200 Amps max. with 70 to 80%lagging power factor1 fault close operation at 8.3kVor 14.4kV; 10,000 amps RMS sym;10 cycles (.17 sec.) 1.3 max. asymfactor applies to new or used matingparts (up to maximum designatedswitching operations) 1ø and 3ø circuits 15.2kV lineto ground, 26.3kV max. across25kVopen contactsCLASS 10 loadmake/break operationsRATINGSat 200 Amps max. with 70 to 80%lagging power factor1 fault close operation at 15.2kVor 26.3kV; 10,000 amps RMS sym;10 cycles (.17 sec.) 1.3 max. asymfactor applies to new or used matingparts (up to maximum designatedswitching operations.) 1ø and 3ø circuits 21.1kV lineto ground, 36.6kV max. across35kVopen contacts.CLASSRATINGS 10 loadmake/break operationsat 200 Amps max. with 70 to 80%lagging power factor.1 fault close operation at 21.1kVor 36.6kV; 10,000 amps RMS sym;10 cycles (.17 sec.) 1.3 max. asymfactor applies to new or used matingparts (up to maximum designatedswitching operations) IEEE 404 Standard for Cable Joints and Splices IEEE 48 Standard for Cable Terminations IEEE 592 Standard for Exposed Semiconducting Shields ANSI C119.4 Standard for Copper and Aluminum ConductorConnectors AEIC CS8 Standards for XLP and EPR Insulated Cables ICEA S-94-649-2004 and S-97-682-2000 Standard forCables Rated 5,000 – 46,000 VoltsCable Joints And Terminations RatingsRefer to the pages listed below for rating information: PCJ Cable Joints, page 32 SFJ Shrink Fit Cable Joints, page 29LOADMAKE/LOADBREAKSWITCHINGFAULT CLOSE Cable Terminations, page 34Separable Connector RatingsThe following chart shows voltage and current ratings which apply to allSeparable Connectors including 200-Amp Loadbreak, 200-Amp Deadbreakand 600 Series Deadbreak products. The next chart shows switching andfault close ratings which only apply to 200-Amp Load-Break Connectors.Voltage and Current Ratings perating VoltageOMaximum line-to-ground(See Application Info Note 1) BILImpulse withstand 1.2 x 50microsecond wave Withstand VoltageAC One MinuteDC Fifteen Minute Corona Extinction Level@ 3pC Sensitivity200-Amp ProductsContinuous Current: SymmetricalMomentary Current:600 Series Products ContinuousCurrentSymmetrical Momentary Current:15kV CLASSRATINGS25kV CLASSRATINGS35kV V40kV78kV50kV103kV11kV19kV26kVApplication Information:1. Load-Break connectors are designed and rated for use on groundedWYE systems. For application on ungrounded WYE or delta systems,the next higher voltage class product is recommended. Examples: 5kVungrounded: use 15kV class products; 15kV ungrounded: use 25kVclass products; 25kV ungrounded: use 35kV class products.2. Products are designed and constructed for all applications includingpadmount, subsurface, vault, indoor, outdoor, direct sunlight, directburied and continuously submerged in water.3. Products are designed and rated for ambient temperatures of -40 Cto 65 C. It is recommended that loadbreak connectors be hotstickoperated at -20 C to 65 C ambient temperature range and ataltitudes not exceeding 6000 feet.200 Amp10kA sym, 10 cycle duration*600 and 900 Amp25kA sym, 10 cycle duration** Designed for 90 C maximum continuous operating temperature.2United StatesTel: 901.252.8000800.816.7809Fax: 901.252.1354Technical ServicesTel: 888.862.3289www.tnb.com

IEEE Standard 386 defines the specific interface dimensions that 200 Ampand 600 Series elbows, inserts, junctions, equipment bushings and anymating components must conform to ensure interchangeability. The table belowprovides information concerning the types of interfaces supplied by Elastimold for various applications and is useful to ensure proper matching of components.BUSHING INTERFACEVOLTAGECLASSINTERFACEDESCRIPTION200-AMP DEEPWELLEQUIPMENT BUSHING15kV, 25kVand 35kV200-Amp BushingWell Interface8.3kV, 15.2kV and, 21.1kVAIEEE386-2001Fig. 3200-AMP LOADBREAK INSERT15kV200-Amp Loadbreak8.3kV and 8.3kV/14.4kVBIEEE386-2001Fig. 5200-AMP LOADBREAK INSERT25kV200-Amp Loadbreak15.2kV and 15.2kV/26.3kVCIEEE386-2001Fig. 7, Note 1200-AMP LOADBREAK INSERT35kV200-Amp LoadbreakInterface No. 221.1kV and 21.1kV/36.3kVDIEEE386-2001Fig. 7, Note 1200-AMP DEADBREAK INSERT15kV and 25kV200-Amp Deadbreak8.3kV and 15.2kVEIEEE386-2001Fig. 4600 SERIES EQUIPMENT BUSHING15kV and 25kV600-Amp DeadbreakInterface No.18.3kV and 15.2kVFIEEE386-2001Fig.11600 SERIES EQUIPMENT BUSHING35kV600-Amp DeadbreakInterface No.121.1kVGIEEE386-2001Fig.13ASTANDARD NO.FIGURE NO.BCDEFGPower & High Voltage — Elastimold Underground Cable AccessoriesOverviewStandard Interfaces for Separable Connectors,Components and Equipment BushingsNote: 1. Elastimold uses Fig. 7 interface for both 25 and 35kV applications.www.tnb.comUnited StatesTel: 901.252.8000800.816.7809Fax: 901.252.1354Technical ServicesTel: 888.862.32893

Power & High Voltage — Elastimold Underground Cable Accessories200-Amp Loadbreak Elbows200-Amp LoadbreakConnectors and Accessories200-Amp Loadbreak Connectors and Accessories provide aconvenient method to connect/disconnect cable and equipment onpower distribution systems. Loadbreak elbows include provisions forenergized operation using standard hotstick tools, allowing loadmake/break operation and a visible disconnect. Components can be isolatedwith insulated caps, plugs and parking bushings.Optional accessories allow system grounding, testing, bypass, surgeprotection and current limiting fusing. Additional connecting pointsand taps can be provided by use of junctions or feed-thrus.Ratings OverviewSee page 2 for completeinformation, including switchingand fault close ratings.200-Amp Loadbreak Separable Connector ComponentsCABLE TO EQUIPMENTCONNECTIONSLOADBREAKBUSHING INSERTBUSHING WELLEXTENDED BUSHING INSERTCurrent Ratings200A Continuous10kA sym. 10 CyclesVoltage Ratings15kV Class8.3kV Phase-to-Ground14.4kV Phase-to-Phase95kV BIL34kV AC Withstand53kV DC Withstand11kV Corona Extinction25kV Class15.2kV Phase-to-Ground26.3kV Phase-to-Phase125kV BIL40kV AC Withstand78kV DC Withstand19kV Corona ExtinctionSEE CABLE NOTESBUSHING WELLPLUGLOADBREAKFEED-THRU PERATING ACCESSORIESGROUNDINGELBOWSEE CABLE NOTESINSULATED PARKINGBUSHINGPARKINGSTANDGROUNDINGPLUGFUSED ELBOWINSULATED CAPFEED THRUINSULATED CAPWITH GROUND35kV Class21.1kV Phase-to-Ground36.6kV Phase-to-Phase150kV BIL50kV AC Withstand103kV DC Withstand26kV Corona Extinction4LOADBREAK ELBOW CONNECTOR WITHOR WITHOUT TEST POINTTEST RODASSEMBLY TOOLSee pages 51-57for surge arresterapplicationsUnited StatesTel: 901.252.8000800.816.7809Fax: 901.252.1354Technical ServicesTel: 888.862.3289www.tnb.comSEE CABLE NOTES

200-Amp Loadbreak V35kVElbowConnectorw/ Test PointJacket SealElbowConnectorJacket SealElbowConnectorw/ Test PointRepair ElbowConnectorRepair ElbowConnectorw/ Test 5kV25kV15kV25kV15kV25kVReplacementElboww/ Test Point15kVDirect TestElbowConnector15kVDirect Test RepairElbowConnector15kVDirect TestRepair ElbowConnectorw/Test Point25kV25kV25kV15kV25kVFused Elbow(Full RangeCurrent Limiting)15kV25kVBolted Elboww/ Tap15kVCAT. NO.165LR-W5XUse Tables W1 and X1275LR-W5XUse Tables W16 and X1375LR-W5XUse Tables W3 and X2166LR-W5XUse Tables W1 and X1276LR-W5XUse Tables W16 and X1376LR-W5XUse Tables W3 and X2165LRJS-W5XUse Tables W1 and X1275LRJS-W5XUse Tables W16 and X1166LRJS-W5XUse Tables W1 and X1276LRJS-W5XUse Tables W16 and X1167ELR-W5XUse Tables W5 and X1273ELR-W5XUse Tables W5 and X1168ELR-W5XUse Tables W5 and X1274ELR-W5XUse Tables W5 and X1167RLR-W5XUse Tables W4 and X1273RLR-W5XUse Tables W2 and X1168RLR-W5XUse Tables W4 and X1274RLR-W5XUse Tables W2 and X1167DLR-W5XUse Tables W4 and X1273DLR-W5XUse Tables W2 and X1167DELR-W5XUse Tables W5 and X1273DELR-W5XUse Tables W5 and X1168DELR-W5XUse Tables W5 and X1274DELR-W5XUse Tables W5 and X1NOTESN2, 3, 4, 5N2, 3, 4, 5N2, 3, 5N2, 3, 4, 5, 23N2, 3, 4, 5, 23N2, 19N2, 19N2, 19, 23N2, 19, 23N5, 10, 18N5, 10, 18N5, 10, 18, 23N5, 10, 18, 23N5, 11, 13N5, 11, 13N5, 11, 13, 23N5, 11, 13, 23N2, 5, 21N2, 5, 21N5, 10, 18, 21N5, 10, 18, 21N5, 10, 18,21, 23N5, 10, 18,21, 23N23N23Bushing Insert15kV25kV35kV35kV167LRT-W5XUse Tables W4 and X11601A42701A43701A43701A3N4, 8N4, 8N6, N16N6, 1615kV160DRN9Insulated Capw/ , 9N7, 9N7, 9Insulated Capw/ Ground andTest omDESCRIPTIONGrounding Plug(1/0 AWG x 6'Ground Lead)GroundingElbow(1/0 AWG x 6'Ground Lead)Feed-ThruN2, 3, 5, 23168FLR W0X274FLR W0XInsulated CapILLUSTRATION(NOT TO SCALE)N17United StatesTel: 901.252.8000800.816.7809Fax: 901.252.1354Feed-ThruVerticalAdjustable Bracket2-Point Feed-ThruAdjustable Bracket3-Point Feed-ThruAdjustable Bracket4-Point Feed-ThruVOLTAGECLASSCAT. 164FT4-AB274FT4-AB373FT4-ABK1601WFTFeed-Thru Well15/25kVFeed-Thru Well Vertical15/25kVInsulated ParkingBushingInsulated ParkingBushingTest RodBushing WellPlugAssembly 6, 2N8N1. Copper lug for use on COPPER CONDUCTOR ONLY.N2. W5X indicates that the catalog number includes 02500X long bi-metal compression lug as standard.For an all-copper lug, replace W5X with W2X in Table X1 to specify the all-copper 02702X lug.N3. Also available as housing only. Specify: 165BLR-W; 275BLR-W;375BLR-W; 166BLR-W; 276BLR-W; 376BLR-W.N4. Also available as elbow/insert combination. Specify: 165A4-WX;275A4-WX; 166A4-WX; 276A4-WX.N5. Also available with 200ECS jacket seal included. Add - “S” suffix to catalog number.N6. Rated for single-phase applications only.N7. Equipped with insulated cuff.N8. Includes internal torquing feature using 200AT Assembly Tool.N9. Also available without probe. Specify “A” suffix - Example: 273DRGA.N10. Repair elbow has extended length contact and elbow housing resulting in a net gain of31 4" in length.N11. Replacement elbow has extended-length contact and elbow housing resultingin a net gain of 87 8" in length.N12. Rated for 25kV thru 35kV applications.N13. Includes long bi-metal contact 00400X.N14. 160CA Cable Size Adapter can only be used with elbow part numbers 165LR/166LR C size only.N16. Fully rotatable for 360 positioning. Includes bail assembly to secure feed-thru insert to bushing well.N17. Includes 02800X bi-metal contact.N18. Includes 02509X long bi-metal contact.N19. Includes built-in jacket seal. Also available as housing only — specify: 165BLRJS-W, 166BLRJS-W,275BLRJS-W or 276LRJS-W. Also available as elbow/insert combination — specify: 165JSA4-W5X,166JSA4-W5X, 275JSA4-W5X or 276JSA4-W5X.N20. Includes a black vent ring.N21. Direct Test Connectors, along with a 200TC-X series meter adapter, a properly ratedvoltage meter and Hot-line Stick provide a means for direct conductor voltage testing.N22. With stainless steel bracket.N23. Test Point Cap catalog number 156-7N24. Add suffix “-SS” for stainless steel bracket.Power & High Voltage — Elastimold Underground Cable AccessoriesILLUSTRATION(NOT TO SCALE)Refer to the W and X tables on page 50 for sizing to cable insulation diameterand conductor size. For cable shield adapters and jacket seals, see page 42.Technical ServicesTel: 888.862.32895

Power & High Voltage — Elastimold Underground Cable Accessories200-Amp Loadbreak Elbows200-Amp Loadbreak Connectors and Accessories (continued)Ratings Overview200-Amp Loadbreak Separable Connector ComponentsSee page 2 for completeinformation, including switchingand fault close ratings.Current Ratings200A Continuous10kA sym. 10 CyclesVoltage Ratings15kV Class8.3kV Phase-to-Ground14.4kV Phase-to-Phase95kV BIL34kV AC Withstand53kV DC Withstand11kV Corona ExtinctionCABLE TO CABLE CONNECTIONS25kV Class15.2kV Phase-to-Ground26.3kV Phase-to-Phase125kV BIL40kV AC Withstand78kV DC Withstand19kV Corona Extinction4-POINTJUNCTION2-POINTJUNCTION2 POINT WELLJUNCTION35kV Class21.1kV Phase-to-Ground36.6kV Phase-to-Phase150kV BIL50kV AC Withstand103kV DC Withstand26kV Corona ExtinctionLOADBREAKBUSHING INSERT3-POINT WELLJUNCTION4-POINT WELLJUNCTION63-POINTJUNCTIONUnited StatesTel: 901.252.8000800.816.7809Fax: 901.252.1354See pages 51-57for surge arresterapplicationsLOADBREAKBUSHING INSERTLOADBREAKBUSHING INSERTTechnical ServicesTel: 888.862.3289www.tnb.com

200-Amp Loadbreak ElbowsDESCRIPTIONContacts:LR Long Bi-MetalELR Bi-MetalLR CopperLRT ContactRLR ContactElbow 5kVCAT. NO.Use Table NOTESN1. Repair elbow has extended-length contact and elbow housingresulting in a net gain of 31 4" in length.N2. Copper lug for use on COPPER CONDUCTOR ONLY.N1N2N3N3. Replacement elbow has extended-length contact and elbowhousing resulting in a net gain of 87 8" in length.N4. 160CA Cable Size Adapter can only be used with elbow catalognumbers 165LR/166LR C, H or CC size only.N5. Also available as rubber only, without straps. Specify suffix “-4”in place of “-5” in the catalog number.N6. Supplied with replaceable stud. Replacement stud availableseparately. Specify 1000-150.ElbowCable EntranceInsulating PlugAll10EP-WUse Table W6Cable SizeAdapter15kV160CA-WUse Table W6EB-FA OnlyN4200TC-1N14N9. Hardware package, consists of “U” straps and back plate only,may be ordered separately by specifying 1601US-J3.200TC-2200TC-4N14N14N10. Hardware package, consists of “U” straps and back plate only,may be ordered separately by specifying 1601US-J4.K1601WJ2N6N11. Hardware package, consists of “U” straps and back plate only,may be ordered separately by specifying 271-68.Direct Voltage TestMeter Adapter for:HD Electric MetersRoss MetersAllChance Meters2-Way WellJunction w/S.S. Bracket2-Way WellJunction w/“U” Straps3-Way WellJunction w/S.S. Bracket3-Way WellJunction w/“U” Straps4-Way WellJunction w/S.S. Bracket4-Way WellJunction w/“U” Straps2-Point Junctionwith/StainlessSteel Bracket2-Point Junctionw/“U” Straps3-Point Junctionwith StainlessSteel Bracket3-Point Junctionw/“U” Straps4-Point Junctionwith StainlessSteel Bracket4-Point Junctionw/“U” Straps15/25kV15/25kVK1601WJ2-5N5, 6, 1115/25kVK1601WJ3N615/25kVK1601WJ3-5N5, 6, 1215/25kVK1601WJ4N615/25kVK1601WJ4-5N5, 6, 4274J4373J4164J4-5274J4-5373J4-5N7N7N7N5, 8N5, 11N5, 11N7N7N7N5, 9N5, 12N5, 12N7N7N7N5, 10N5, 13N5, 13www.tnb.comUnited StatesTel: 901.252.8000800.816.7809Fax: 901.252.1354N7. Hardware packages, consisting of brackets and straps only,may be o rdered separately by specifying “-6” in the catalog number.Example 164J4-6.N8. Hardware package, consists of “U” straps and back plate only,may be ordered separately by specifying 1601US-J2.N12. Hardware package, consists of “U” straps and back plate only,may be ordered separately by specifying 271-61.N13. Hardware package, consists of “U” straps and back plate only,may be ordered separately by specifying 271-70.N14. For use with Direct Test Connectors.Power & High Voltage — Elastimold Underground Cable AccessoriesILLUSTRATION(NOT TO SCALE)Refer to the W and X tables on page 50 for sizing to cable insulation diameterand conductor size. For cable shield adapters and jacket seals, see page 42.Technical ServicesTel: 888.862.32897

Power & High Voltage — Elastimold Underground Cable Accessories200-Amp Deadbreak Elbows200-Amp DeadbreakConnectors and Accessories200-Amp Deadbreak Connectors and Accessories provide a quickdisconnect feature for cable and equipment connections on powerdistribution systems.All deadbreak connectors must be de- energized before operating and mustbe mechanically secured with bails when connected. Components can beisolated with insulated caps, plugs and parking bushings.All deadbreak elbows are equipped with test points as standard. Optionalaccessories allow system grounding, bypass and lightning surge protection.Additional connecting points and taps can be provided by use of junctionsor feed-thrus.Ratings Overview200-Amp Deadbreak Separable Connector ComponentsSee page 2 for complete information.CABLE TO EQUIPMENTBUSHING WELL PLUGCurrent RatingsBUSHINGWELL200A Continuous10kA sym. 10 CyclesBUSHINGINSERTINSULATED CAPVoltage Ratings15kV Class8.3kV Phase-to-Ground14.4kV Phase-to-Phase95kV BIL34kV AC Withstand53kV DC Withstand11kV Corona Extinction25kV Class15.2kV Phase-to-Ground26.3kV Phase-to-Phase125kV BIL40kV AC Withstand78kV DC Withstand19kV Corona ExtinctionDEADBREAKFEED-THRU INSERTOPERATING ACCESSORIESSTRAIGHT RECEPTACLEINTEGRAL BUSHINGPARKINGSTANDSTAND-OFF PLUGELBOWCONNECTORGROUNDING PLUGCABLE TO CABLE CONNECTIONSFEED THRUINSULATED PLUGSTRAIGHT PLUGLOCKING ANDREPAIR SPLICEIN-LINE JUNCTIONLOCKING“Y” SPLICEExcept for locking splices all200A deadbreak products mustbe mechanically secured with abail when connectedTEE SPLICE3-POINTJUNCTION4-POINTJUNCTION8United StatesTel: 901.252.8000800.816.7809Fax: 901.252.1354See pages 51-57for surge arresters applications2-POINTJUNCTIONTechnical ServicesTel: 888.862.3289www.tnb.com

200-Amp Deadbreak ElbowsDESCRIPTIONVOLTAGECLASSCAT. NO.156LR-W5XElbow Connectorw/ Test Point15/25kVDirect TestElbow Connector15/25kVBail Assemblyfor 156LR Elbow15/25kV150BABushing Insert15/25kVK1501A1N3Feed-Thru Insert15/25kVK1502A1N3, 4Insulated Plug15/25kVK150DPN3Insulated CapUse Tables W4 and X1156DLR-W5XUse Tables W4 and X1K150DR15/25kVN1, 215/25kVK151SOPN3Grounding Plug15/25kV151GPN3Feed-Thru15/25kVK1501FTN3, 62-Point Junction15/25kVK1501J2-U8N3, 63-Point Junction15/25kVK1501J3-U8N3, 64-Point Junction15/25kVK1501J4-U8N3, 6Elbow t Plug15/25kVTee SpliceN3, 12,Use Tables W1 and X1 13, 17, 18K151SP-W0XUse Tables W1 and X1N3, 12,13, 1915/25kVK150TN3In-Line Junction15/25kVK150SN3Locking Splice/Repair Splice15/25kVLocking 150TB2N5Bail15/25kV150TB3N5K151LS-W0XUse Tables W1 and X1VOLTAGECLASSCAT. s:Long Bi-MetalCopperElbow Cable EntranceInsulating PlugCable EntranceInsulating PlugN3K151SR-W0XDESCRIPTIONN1, 2, 22Insulated ParkingBushingK151LY-W0XILLUSTRATION(NOT TO SCALE)NOTESN8, 9, 13,15, 16,17, 20, 23N8, 9, 13,Use Tables W1 and X1 15, 17, 21Cable Size Adapter15/25kV15/25kV15/25KV10EP-WUse Table W6152EA-WUse Table W6160CA-WUse Table W6EB-FA OnlyN10N11N14N1. Includes bail assembly.N2. W5X indicates that the catalog number includes a 02500X bi-metal compression lug, which israted for either aluminum or copper conductor, as standard. For an all-copper lug, replace W5Xwith W2X. Use Table X1 to specify the all-copper 02702X lug.N3. Bails are required but not included. Order separately. Consult factory for bails not listed for aspecific application.N4. Fully rotatable for 360 positioning. Includes bail assembly to secure feed-thru insert to bushingwell. Elbows bail assemblies are required but not included with the feed-thru insert.N5. Refer to factory for application details.N6. Center-to-center spacing equals 4 inches.N7. Copper lug for copper cable only.N8. To order cable legs for different cable sizes, list each leg size “W” and “X”.Example: K151LY-A1240-A1240-B1220. See Tables W1 and X1 for sizes.N9. To order locking contacts for K151LS and K151LY, order 01401X (Al) or 01402X (Cu) for plugcontact. Order 01301X (Al) or 01302X (Cu) for receptacle. See Table X1 for sizes.N10. For use with 156LR elbows.N11. For use with K151SR, K151SP, K151LS, K151LY receptacles, plugs and splices.N12. Also available as housing only. Specify K151BSP-W or K151BSR-W.N13. Also available in EB-FA sizes per Table W6 by using 160CA cable adapter with C size plugsand receptacles.N14. 160CA cable adapter can only be used with C size plugs and receptacles.N15. Bails are not required for locking splices.N16. When used as a repair splice, the assembled length allows 4" for cable replacement/repair.N17. Straight receptacles are also available with test point. Specify K152SR-W0X catalog number.N18. W0X indicates that the catalog number includes a 01500X universal aluminum compression lug,which is rated for either aluminum or copper, as standard. For an all-copper lug, replace W0X withW2X in Table X1 to specify the all-copper 01502X lug.N19. W0X indicates that the catalog number includes a 01600X universal aluminum compression lug,which is rated for either aluminum or copper, as standard. For an all-copper lug, replace W0X withW2X in Table X1 to specify the all-copper 01602X lug.N20. W0X indicates that the catalog number includes a 01400X universal aluminum compression lug,which is rated for either aluminum or copper, as standard. For an all-copper lug, replace W0X withW2X in Table X1 to specify the all-copper 01402X lug.N21. W0X indicates that the catalog number includes a 01300X universal aluminum compression lug,which is rated for either aluminum or copper, as standard. For an all-copper lug, replace W0X withW2X in Table X1 to specify the all-copper 01302X lug.N22. Direct Test Connectors, along with a 200TC-X series meter adapter, a properly rated voltagemeter and Hot-line Stick provides a means for direct conductor voltage testing.See page 7 for meter adapters.N23. Gains approximately 4" of repair length.Power & High Voltage — Elastimold Underground Cable AccessoriesILLUSTRATION(NOT TO SCALE)Refer to the W and X tables on page 50 for sizing to cable insulation diameterand conductor size. For cable shield adapters and jacket seals, see page 42.www.tnb.comUnited StatesTel: 901.252.8000800.816.7809Fax: 901.252.1354Technical ServicesTel: 888.862.32899

Power & High Voltage — Elastimold Underground Cable Accessories600-Amp Elbow Connectors600 Series DeadbreakComponents600 Series deadbreak elbows, straight receptacles, junctions, vaultstretchers and accessories are used to connect equipment and cableon primary feeder and network circuits. Designs accommodate largeconductors and feature bolted connections and deadfront modularconstruction for maximum reliability, performance and versatility.De-energized connectors can be quickly and easily connected anddisconnected using standard hand tools and equipment in accordancewith accepted operating practices. Optional accessories allow visibleexternal separation, bypass, isolation, dead-ending, grounding andtesting as well as adding taps, surge arresters and circuit protection.Hotstick-operable and separable joint systems are shown onpages 16–19 and 20–21.Spiking Aid-TWhen spiking a medium voltage cable near a stacked T-Body cablejoint, the Elastimold Spiking-T is a specially designed product to reduceoutage time and cost. Medium voltage cable is spiked as a meansto assure the circuit is de-energized where there is no sectionalizingdevice, direct testing means or provision for grounding. One leg ofstacked T-Body cable joint is spiked/cut with a grounded guillotine typecable cutter, near the T-Body intersection. Once spiked and p

200-Amp Bushing Well Interface 8.3kV, 15.2kV and, 21.1kV IEEE 386-2001 Fig. 3 200-AMP LOADBREAK INSERT 15kV 200-Amp Loadbreak 8.3kV and 8.3kV/14.4kV IEEE 386-2001 Fig. 5 200-AMP LOADBREAK INSERT 25kV 200-Amp Loadbreak 15.2kV and 15.2kV/26.3kV IEEE 386-2001 Fig. 7, Note 1 200-AMP LOADBREAK INSERT 35kV 200-Amp Loadbreak Interface No. 2 21.1kV and .

Related Documents:

Elastimold permite al usuario combinar los diferentes componentes individuales y obtener productos que mejoren la confiabilidad y el desempeño de sus sistemas de distribución. Los beneficios de Elastimold Todos los componentes del se

Catalogue 2020-21 Life Line Plus S3 (HRFR) Cable Life Guard (FR-LSH) Cable Life Shield (HFFR) Cable Multicore Round Cable Shielded Cables Flat Submersible Cable Telephone Switch Board Cable LAN Cable CCTV Cable Co-Axial TV Cable Speaker Cable Presenting Domestic Cable Range for Safer, Securer Homes.

instrumentation tray cable 10 general purpose cable 12 instrumentation tray exposed run direct burial cable 14 power tray exposed run direct burial cable 16 industrial ethernet cable 18 fieldbus technology cable 20 extremelife cable 22 flexlife cable 24 weldlife cable 26 armorfast instrumentation cable 28 flexible service cable

Underground Cable IGURE This cable is designed to carry power in trays, underground or even suspended. It has an outer jacket, cable sheath, primary insulation, and primary conductors. The cable may be one or three conductors enclosed in one cable. Typically for distribution systems, the cable is simple with one

Power Cable Accessories Under the well-established brand name Raychem, Raychem RPG offers a comprehensive range of cable accessories for almost all cable types. Raychem power cable accessories have over 40 years of design life – which has been proven by long-

Underground ducts 22 - 23 Underground Direct Burial 24 - 25 In Air 34 In Conduit 37 Triplexed Conductors Underground Ducts 26 - 27 Underground Direct Burial 28 - 29 In Air 35 In Conduit 37 Three Conductor Underground Ducts 30 - 31 Underground Direct Burial 32 - 33 In Air 36 In Conduit 38 N.E.C. Code Table 38 SECTION 7 Installation Practices 39 - 51

Underground storage tanks: groundwater protection code Page 1 of 32 Contents 1. Introduction 2. Assessing and preparing for risks for an underground storage tank 3. Develop an environmental management system 4. Installing an underground storage tank 5. Using an underground storage tank 6. Decommissioning an underground storage tank 7. Train .

Underground cables are prone to a wide variety of faults due to underground conditions, wear and tear, rodents etc. Diagnosing fault source is difficult and entire cable should be taken out from the ground to check and fix faults. The project work is intended to detect the location of fault in underground cable lines from the base .