IECEx Certificateof ConformityINTERNATIONAL ELECTROTECHNICAL COMMISSIONIEC Certification System for Explosive Atmospheresfor rules and details of the IECEx Scheme visit www.iecex.comCertificate No.:IECEx EESF 20.0044XPage 1 of 5Status:CurrentIssue No: 1Date of Issue:2021-06-17Applicant:Vaisala OyjVanha Nurmijärventie 21FI-01670 VANTAAFinlandEquipment:HMT370EX Humidity and Temperature TransmitterOptional accessory:Vaisala USB-cableType of Protection:Ex iaMarking:Ex ia IIC T4 GaEx ia IIIC T200 85 C Da-40 C Tamb 60 C.Approved for issue on behalf of the IECExCertification Body:Jenni HirveläPosition:Senior ExpertSignature:(for printed version)Date:1. This certificate and schedule may only be reproduced in full.2. This certificate is not transferable and remains the property of the issuing body.3. The Status and authenticity of this certificate may be verified by visiting www.iecex.com or use of this QR Code.Certificate issued by:Eurofins Expert Services OyKivimiehentie 4FI-02150 EspooFinlandCertificate history:Issue 0 (2021-02-08)

IECEx Certificateof ConformityCertificate No.:IECEx EESF 20.0044XPage 2 of 5Date of issue:2021-06-17Issue No: 1Manufacturer:Vaisala OyjVanha Nurmijärventie 21FI-01670 VANTAAFinlandAdditionalmanufacturinglocations:This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with theIEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed andfound to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx SchemeRules, IECEx 02 and Operational Documents as amendedSTANDARDS :The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was foundto comply with the following standardsIEC 60079-0:2017Edition:7.0Explosive atmospheres - Part 0: Equipment - General requirementsIEC 60079-11:2011Edition:6.0Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"This Certificate does not indicate compliance with safety and performance requirementsother than those expressly included in the Standards listed above.TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in:Test Report:FI/EESF/ExTR20.0043/01Quality Assessment Report:FI/EESF/QAR19.0011/02

IECEx Certificateof ConformityCertificate No.:IECEx EESF 20.0044XPage 3 of 5Date of issue:2021-06-17Issue No: 1EQUIPMENT:Equipment and systems covered by this Certificate are as follows:Vaisala Intrinsically Safe Humidity and Temperature Transmitter HMT370EX Series is designed with the protection concept Ex ia and isintended to be used in Groups IIC and IIIC. Equipment consists of the HMT370EX transmitter and HMP370EX probe. The HMT370EX consistof three main parts: the transmitter body, a detachable probe body and a probe head attached to the probe body, either directly or with acable.The enclosure Type of Protection is IP54 (IEC 60079-0).Input values of 4.20 mA loops (ch. 1 and 2):Ui 28 VdcIi 100 mAPi 700 mWCi 12.1 nFLi 16 μH.Two transmitter body types are available in HMT370EX series.Model ExplanationTamb rangeTemperature classDisplay and 4 button keypad-40 C 60 CT4LED indicator-40 C 60 CT4The probe can only be used together with the transmitter body in explosive atmospheres. In safe area, transmitter and probe can be used withVaisala USB-cable connected to a PC.SPECIFIC CONDITIONS OF USE: YES as shown below:1. The cable glands and blanking elements used with the transmitter shall conform to requirements of IEC 60079-0.2. For EPL Ga Group II it has to be ensured that sparks due to impact or friction do not occur.

IECEx Certificateof ConformityCertificate No.:IECEx EESF 20.0044XPage 4 of 5Date of issue:2021-06-17Issue No: 1Equipment (continued):A series of probes (HMP370EX) are available in the HMT370EX series. They all have the same probe body, but different probe head. Thedifferences between the probes are process interface, temperature range and pressure range. Probe heads come with three different cablelengths. The available probe models are listed below:ModelExplanationCable lengthsAmbienttemperature rangeProbe headtemperatureProbe headtemp. class1for wall mountingNo Cable-40 C 60 C-40 C 60 CT43for confined spaces2, 5 and 10 m-40 C 60 C-40 C 55 C-40 C 100 C-40 C 120 CT6T5T44for pressurizedspaces2, 5 and 10 m-40 C 60 C-70 C 55 C-70 C 100 C-70 C 135 C-70 C 180 CT6T5T4T35for high temperatures 2, 5 and 10 m-40 C 60 C-70 C 55 C-70 C 100 C-70 C 135 C-70 C 180 CT6T5T4T37for high humidities-40 C 60 C-70 C 55 C-70 C 100 C-70 C 135 C-70 C 180 CT6T5T4T30. 1 MPa8for pressurizedpipelines-40 C 60 C-70 C 55 C-70 C 100 C-70 C 135 C-70 C 180 CT6T5T4T30 4 MPa-40 C 60 C-70 C 55 C-70 C 100 C-70 C 135 C-70 C 180 CT6T5T4T30 4 MPa-40 C 60 C-70 C 55 C-70 C 100 C-70 C 135 C-70 C 180 CT6T5T4T30 4 MPaFHfor moisture in oilfor moisture in fuel2, 5 and 10 m2, 5 and 10 m2, 5 and 10 m2, 5 and 10 mProbe headpressure range0 10 MPa

IECEx Certificateof ConformityCertificate No.:IECEx EESF 20.0044XPage 5 of 5Date of issue:2021-06-17Issue No: 1DETAILS OF CERTIFICATE CHANGES (for issues 1 and above)Probe head temperature ranges and Temperature Classifications revised.

IEC 60079-0:2017 Edition:7.0 Explosive atmospheres - Part 0: Equipment - General requirements IEC 60079-11:2011 Edition:6.0 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" This Certificate does not ind

Related Documents:

Sep 09, 2010 · Vaisala PTB220 Vaisala HMP45C Vaisala HMP45C RM Young 05103 RM Young 05103 Vaisala PWD22 (E13 only) starting 9/9/10 NovaLynx TBRG & Vaisala PWD22 (E13 . Data loggers (CR10, CR10X, CR1000, CR23X, CR3000) Campbell Scientific Inc.

Vaisala VaiNet Access Point AP10 is a wireless access point that collects data from VaiNet wireless data loggers and transfers it to viewLinc Enterprise Server using a wired Ethernet connection. AP10 implements Vaisala's proprietary VaiNet protocol. It can connect up to 32 RFL100 Data Loggers

IECEx Auditing Practices for ISO/IEC 80079-34 ISO 9001 coverage 1. Approach when Auditing of both ISO 9001 Certified Non Certified CompaniesCertified Companies 2. Planning / Audit conduct / Reporting / Surveillance accordinggq to IECEx requirements 3. QAR registration on IECEx website

Based on ISO/IEC 17065/17025 IECEx Rules Procedures ODs. No need to conduct factory audit and surveillance for IECEx “Unit Verification” Certificate. . Standard IECEx Certificate Number . 22 Certificate Number on the

future needs. Look forward to even greater insights with upcoming real-time lightning data and near-term weather forecasts. Vaisala never stops innovating to give you the best quality, performance and value for your investment. Key features CAP 437 required weather and environmental measurements include Vaisala's wind speed and direction,

To set up individual Loggers, refer to your Logger-specific User Guide, or Vaisala Veriteq vLog and Spectrum software online Help and User Guides. Once your Loggers and vNets are installed and configured, refer to the Vaisala Veriteq viewLinc User Guide or online Help to learn more about: Viewing Logger data Setting and acknowledging alarms

Ex e IIC T5** Gb (LT8, LT28, LT10, LT210, UT-1) Ex tb IIIC T 95ºC Db QLT: IECEx KEM 07.0041 Ex e IIC T3 Gb Ex tb IIIC T 195ºC Db HLT: IECEx KEM 07.0041 Ex e IIC T3 Gb Ex tb IIIC T 195ºC Db XLT: IECEx KEM 07.0041 Ex e IIC T3 Gb Ex tb IIIC

Accounting implications of the effects of coronavirus At a glance This In depth considers the impact of the new coronavirus (‘COVID-19’ or ‘the virus’) on the financial statements for periods ending after 31 December 2019 of entities whose business is affected by the virus. There are broad IFRS implications, including: non-financial assets; financial instruments and leases; revenue .