AIR COOLED PACKAGED CHILLERUNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to theinternational standards and works continually to improve its products and facility. As a result, the design and specifications ofeach product at the time of order may be changed without notice and may not be described herein. Please contact ourcustomer department for specific information on the current design.Consultancy & Design Our Engineering Dep’t is always available to solve special requirements, investigating the client situationand using the most sophisticated available tools. The knowledge and the precious experience of our Engineers is supported bythe most advanced computerized calculations and design programs.Revision AG 16-07COOLER is equipped to produce Air Cooled Packaged Liquid Chillers which conform to standards set by advancing technologiesand use the most sophisticated American and European materials.APPLICATIONS. Perfectly convenient for Apartments, Offices, Small and Large Industries, Hospitals, Hotels, Sports Halls and Minior Maxi Store. Units are especially patterned to meet modern design requirements and are suitable for vertical air flow.Standard COOLER Air Cooled Packaged Liquid Chillers have the following characteristics:CAPC Models: from 30 up to 502 Ton (from 87,000 up to 1,500,000 Kcal) All Units can be custom tailored on request The COOLER Air Cooled Packaged Liquid Chillers is a packaged unit completely factory assembled on a stiff steel structure withpanels made from heavy gauge zinc galvanized or zinc or primered sheets with a baked fine enamel finish, making them weatherresistant and suitable for outdoor installations. All piping and electrical wiring are ready for external field connection.Units are factory tested at 28 bar (400 psig), flushed and Freon charged. Compressors have the initial oil charge.OPERATIONAL TEST are performed to verify that all circuits and safety devices are operating properly with large margins ofsecurity.NOISE TEST are also performed to verify that body panels, fans and motors, air and liquid flow, etc, shall operate according tothe highest standard of performance.

CONTROLS CABINET A weatherproof cabinet harbours all indicator devices, switches, lamps, as well as most of the relays,contactors, circuit breakers, pressure gauges, electric terminals, etc.Power Compartment controls include: -Refrigerant high pressure cut-off manual reset. -Compressor motor contactors. -Refrigerant low pressure cut-off. -Fan motor contactors. -Electronic digital Thermostat chilled liquid cycling. -Fan motor circuit breaker(s). -Freezestat low liquid temperature. -Power terminal blocs 230 & 400V 50Hz. -Restart compressor time delay. -Separate 230V control circuit terminal block (for -High and low voltage protection.field wiring). -Phase failure protection. -Compressor staging relays. -Fan cycling controls pressure actuated (optional). -Compressor crankcase heater relays. -Compressor staging (optional). -ControI circuit terminals. -Liquid flow control (optional). -Control circuit breaker(s). -Soft start electronic control (optional). -Field auxiliary control terminals. -Micro-processorprogrammablecontrollerSafety and Operating Controls include:(optional). -System on-off switch. -Oil pressure cut-off manual reset.PRESSURE GAUGES. Factory mounted suction and discharge pressure gauges for each refrigerant circuit and an oil pressuregauge for each compressor are provided. Each gauge is supplied with its own manual shutoff valve.FAN CYCLING MEDIUM AMBIENT CONTROL. Fans are automatically cycled in response to gas pressure to maintain adequatehead pressure and allow compressor start at 30 F ambient (optional).COMPRESSOR CIRCUIT BREAKERS OR COMPRESSOR FUSE BLOCKS. Either companion trip, ambient compensated circuitbreakers with built-in three leg overload protection; or three leg fuse blocks, with time delay (dual element) fuses, provideadditional protection for each compressor (option).REFRIGERANT PIPING. All circuits are made of brazed seamless copper tubes.Refrigerant circuits include: -Thermal expansion valve. -Manual liquid line shut-off valve. -Permanent charging ports. -Automatic liquid line shut-off valve. -Liquid receiver. -Refrigerant filter-drier. -Suction accumulator (heat pump). -Liquid sight glass/moisture indicator. -External muffler (optional). -Liquid line solenoid valve.DISCHARGE LINES Formed of pre-bent tubing or elbow fittings with long radius bends to eliminate vibrations and minimizepressure drops.

SUCTION LINES Designed for minimum friction loss and proper oil return. All suction lines are insulated with flexible closed cellhoses.CONDENSER COILS Made of seamless copper tubes expended onto aluminum fins. Copper fins and lacquered or anodized finsare also available on request. Size of pipes, number of rows, face area, etc., are in accordance with the compressor capacity,evaluated as per ARI standard code.CONDENSER FANS are direct driven propeller type. Blades are statically and dynamically balanced and run at low RPM for quietand vibration-free operation. Fan blades are protected by heavy gauge fan guards. On request a centrifugal forward curved typeblower can be supplied, statically and dynamically balanced, with parts made of galvanized steel sheet, driven directly or bybelts.FAN MOTORS are permanent split capacitor induction type or three phase type with inherent thermal protection. Motors havepermanently lubricated ball bearings and are of water proof enclosed type designed for service at ambient temperatures up to60 C, with additional moisture protection, making them suitable for outdoor conditions. Motors are suitable for horizontal andvertical working positions, and run at low speed, producing low noise, and are manufactured in accordance with most Europeanand American electric norms.COMPRESSORS. COPELAND semi hermetic compressors are used, refrigerant gas cooled type with built-in thermal protection,crankcase heater and large voltage capacity, suitable for 50 and 60 Hertz application. Each compressor is mounted on isolatorpads and connected via flexible — vibration — absorbers to the coil copper tubing to reduce vibration transmission to the rest ofthe unit. Compressors are designed for high energy efficiency, compact construction , rugged reliability, long-life and aremaintenance free. Compressors can be disassembled in the field for service.Oil level sight glass is standard. Oil electronic pressure control cuts the power to the motor when the pressure drops belowacceptable limits. Larger compressors have a built-in relief valve between suction and discharge lines which will open if themaximum permissible pressure differential is reached.EVAPORATOR is a shell and tube type cooler. The construction is in accordance with most American and European Norms andcodes (TEMA — RINA — ISPESL — TUV - SDM). Weather and corrosion resistant suitable for outdoor applications. Gas tubes aremade of seamless copper tubes and are tested at 28 bar (400 psig). Shell have standard trade water outlets for thermostat, airvent, drain and water main stream. This liquid cooler is also suitable as liquid heater in Heat pump mode.ECONOMIZER shell and tube type is available on request, it improves the chilling capacity of the unit, by precooling the chiller,and preheating the gas at the compressor suction line.ELECTRIC junction board shall be color coded and wires identified for easy field connections and maintenance. It includescompressor and fan motor contactors, thermal overload protection, high/low voltage and phase failure protectio, pressureprotection cut of relay with compressor restart delay, compressor crankcase heater relay, circuit fuse beakers, and codedterminals.

WATER PUMP can be included as an accessory according to client specifications. Thermometers and pressure gauges on theliquid inlet and outlet can be provided on reques. Air vents are standard.INSTALLATION of the unit is easy because it needs only to be connected to the outside utilities: liquid line and electric powersupply.ELECTRIC BOARD with remote control and functional display with duty lamps and alarms can be supplied.24 VAC transformer ready to connect electronic thermostat (optional).ACCESS to all internal parts for cleaning or maintenance, needs loosening of a few screws only to remove any pane. All parts canbe easily removed & replaced.COOLER Service Department is always available to serve our customer and ready to solve any problem.COOLER Project Department is ready to study cases and to supply the most economic, yet feasible solutions.QUALITY GUARANTEUNIC sal COOLER guarantees contractual free maintenance, availability of all parts and components, and qualified fieldtechnicians to carry out the maintenance requirements.UNIC sal Company is ISO 9001:2015, DQS-UL, IQNet and CE Certified.

UNIC sal Roumieh (Industrial area) BeirutTel: 961.1.890111-222 — 1.884579 — 1.878853 — 3.236936Fax : 961.1.878854 — P.O.Box 90.1701 Beirut, LEBANONunic@unic-cooler.com - www.unic-cooler.com

Standard COOLER Air Cooled Packaged Liquid Chillers have the following characteristics: CAPC Models: from 30 up to 502 Ton (from 87,000 up to 1,500,000 Kcal) All Units can be custom tailored on request The COOLER Air Cooled Packaged Liquid Chillers is a packaged unit completely factory assembled on a stiff steel structure with

Related Documents:

EWY Air-cooled chiller, heat pump EWL Remote condenser chiller ERA Air cooled condensing unit EWW Water-cooled chiller, cooling only EWC Air-cooled chiller, cooling only with centrifugal fan EWT Air-cooled chiller, cooling only with heat recovery Refrigerant D R-134a P R-407c Q R-410a Capacity class in kW (Cooling) Always 3 .

The chiller plant in consideration served a medium-scale commercial building in Dubai and consisted of three air-cooled twin-circuit screw chillers - Chiller-1 which is the redundant chiller, Chiller-2 which is the lag chiller and Chiller-3 which is the lead chiller. Chiller-3 started first and ran for 6 minutes.

Air-Cooled Chiller The use of air-cooled chillers in process and comfort cooling applications has been steadily increasing in recent years. The air-cooled chiller has evolved from a packaged product, with few options, to a fully customizable unit that can be tailored to meet specific application and job site requirements. High-efficiency air-cooled

Air Cooled Chiller Air Air 2 Air Air 6 AIR COOLED CHILLERS Air-cooled chillers are refrigeration machines that remove heat from cooling loads using chilled water and reject this heat into the atmosphere using refrigerant. THEY ALL HAVE fans, condenser coils, and compressors. Air-cooled chillers are used to provide cooling for human comfort and electronic equipment as well as industrial process .

Water cooled W 220-240V, 50Hz 2 Inverter H-Q Water cooled 0 0 1 2 R132 C Earth source E 115-220V, 50/60Hz 3 DC inverter R-Z Earth source R134A D 220-220V, 60Hz 4 Air-cooled module chiller A R410A E 110V, 50-60Hz 5 Light chiller Split-packaged H Cooling only R22 M 220V, 50-60Hz 6 Single-packaged R R407C N 127V, 60Hz 7 Water-cooled cabinet .

Select an air-cooled, packaged chiller to cool 108 GPM of 100% water from 54 F to 44 F. Design ambient air temperature 95 F. Find: Air-cooled chiller model. Solution: 1. Chilled fluid Delta T 54 F - 44 F 10 F 2. Capacity (in BTUH) 108 GPM x 10 F Delta T x 500 540,000 BTUH 3.component sizing. From the PSA chiller capacity tables .

Standard Chiller/HP modulare per compressore a vite Generico/Bitzer con driver CAREL Cod.: 030221296 - Rel. 1.4 11/09/08 7 1. Applications and functions performed by the software Type of control unit AIR / WATER CHILLER Chiller only Chiller Heat pump Chiller Freecooling WATER / WATER CHILLER Chiller only

Intermediate Russian: A Grammar and Workbook comprises an acces-sible and practical grammar with related exercises in a single volume. Using a wide variety of texts from Russian sources, Intermediate Russian enables students to gain an insight into contemporary Russian society and culture whilst strengthening their fluency in the language. Its .