Series 45 Frame F Service Manual - Sgteh.by

2y ago
4 Views
1 Downloads
4.34 MB
47 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Camden Erdman
Transcription

Service ManualOpen Circuit Axial Piston PumpsSeries 45 F Framepowersolutions.danfoss.com

Service ManualSeries 45 F Frame Open Circuit Axial Piston PumpsRevision historyTable of revisions2 Danfoss September 2016DateChangedRevSeptember 2016Added displacement limiter adjustments0206June 2016Fix references to TI Manual0205June 2016edits to Fan Drive Control0204March 2016add Fan Drive Control0203September 2014add ETL and angle sensorBBAugust 2014Danfoss layoutBAOctober 2012add electric controlsAFNovember 2010new back pageAEFebruary 2010Fix Osaka addressADJuly 2009Add Pressure change - PC adjustment specsACSeptember 2007minor edits and correctionsABNovember 2006First editionAAAX00000008en-US0206

Service ManualSeries 45 F Frame Open Circuit Axial Piston PumpsContentsIntroductionTechnical specificationsFeaturesPressure measurementInitial Start-Up ProceduresFluid and Filter MaintenanceTroubleshooting Danfoss September 2016Overview.5Safety precautions.5Warranty. 6Symbols used in Danfoss literature.6General description. 6System circuit.7General specifications.9Type of mounting. 9Auxiliary mounting pad options.9Control options.9Port options.9Direction of rotation.9Installation position.9Technical specifications.9Hydraulic parameters. 10Inlet pressure.10Pressure compensator valve setting.10Case pressure. 10Hydraulic fluid .11Temperature range. 11Fluid viscosity.11Filtration .11Displacement limiter.12Auxiliary mounting pads. 12Input shafts.12Control options.12General. 12PC control. 13LS control.13Electric Proportional Controls. 14Electric Proportional Control Principle. 15Electric On/Off Controls.15Electric On-Off Control Principle. 16Fan Drive Control (FDC).16PLUS 1 Compliance.16Fan Drive Control Principle .17S45 pump with integrated FDC control schematic.17Electronic Torque Limiting Controls (ETL). 17Required tools.

Danfoss Series 45 Frame F open circuit piston pumps convert input torque into hydraulic power. The . Service Manual Series 45 F Frame Open Circuit Axial Piston Pumps . 90 [5.49] Flow at rated speed (theoretical) l/min [US gal/min] 177.6 [46.9] 198 [52.3] Input torque at maximum d

Related Documents:

Series 45 Axial Piston Open Circuit Pumps Tech. Information Series 45 Data Sheet 520L0519 11076184 Service Manuals Series 45 Frame E Service Manual Series 45 Frame F Service Manual Series 45 Frame G Service Manual Series 45 Frame H Service Manual Series 45 Frame J Service Manual Series 45 Frame K and L Service Manual 520L0606 11005158 520L0605 .

ETU Trip Unit Style B PXR 10 E PXR 20 D PXR 20D P PXR 25 Ampere Frame Rating 0125 125A Frame 0250 250A Frame 0400 400A Frame H250 250A Frame Selective H400 400A Frame Selective 0600 600A Frame High Override 0630 630A Frame High Override Features N None R Relays Z ZSI, Relays M Modbus, Relays C CAM Inte

Frame kW - 20,000 40,000 60,000 80,000 100,000 120,000 140,000 NovaLT5-1 NovaLT12 NovaLT16-2 LM2500/PGT25 LM2500 /PGT25 Xtend 9ppm LM2500 /PGT25 LM2500/PGT25 G4 LM2500/PGT25 G5 LM6000PF LM6000PC LM6000PG LM6000PF LM9000 LMS100-PB LMS100-PB Frame 5/1PA Frame 5/2C Frame 5/2E Frame 5/2D Frame 6 Frame 7EA Frame 9 Industry leader in gas turbine .

SMB_Dual Port, SMB_Cable assembly, Waterproof Cap RF Connector 1.6/5.6 Series,1.0/2.3 Series, 7/16 Series SMA Series, SMB Series, SMC Series, BT43 Series FME Series, MCX Series, MMCX Series, N Series TNC Series, UHF Series, MINI UHF Series SSMB Series, F Series, SMP Series, Reverse Polarity

FRAME SENSORY MODELING AND STABILITY OF ONE-SIDED FRAME PERTURBATION 3 where we have assumed { ha n} is a dual frame of the perturbed/estimated frame {han} of the unknown frame {h n}, and {ha n} can be viewed as resulting from a sufficiently small perturbation of {h n} so that {ha n} remains a frame in X sp{h n}.Unlike (1.1), fa is understandably merely an approximation of f via the .

Attaching the screen to frame The next step is to attach the screen to the frame. 1. Place the frame over the screen. Figure 11: Lifting frame to snap on screen; top corner first 2. While lifting the frame with one hand, snap the screen into the frame. Gently allow the screen to stretchon

PowerPact R-Frame Operation Ratings PowerPact R-Frame Circuit Breaker Data Sheets PowerPact R-Frame Enclosure Sizes All type ET electronic trip UL/IEC M-frame, P-frame and R-frame circuit breakers are available as standard rated circuit breakers. Micrologic electronic trip UL/IEC circuit breakers are also available in 100% rated constructions.

Many researchers have worked for corrugated plate heat exchanger with configuration corrugation angle of 3̊. In the present work, corrugated plate heat exchanger with 3̊ corrugation angle has been modeled and results have been compared with that of the base paper. Further the corrugation angle has been changed to 45̊.