Electric Resistive Steam Humidifiers

1y ago
7 Views
2 Downloads
1.01 MB
8 Pages
Last View : 15d ago
Last Download : 3m ago
Upload by : Julia Hutchens
Transcription

Electric Resistive Steam Humidifiers Humidification and Evaporative Cooling humidity.com

Nortec RS-Series humidifiers resolve demanding application needs. Productivity and quality of life are directly affected by the indoor environment. People work better and feel better in favorable surroundings. So do products and machines! They all respond in various ways to changes in air quality, temperature and humidity. All three elements must be just right to maximize performance and reliability, both in humans and equipment. Correct humidity is critical, since too much humidity can be as destructive as too little. Nortec is a world leader in state-of-the-art humidification technology. Our focus is concentrated exclusively on designing and building better humidification systems. Every Nortec RS-Series model has been engineered to meet the highest standards of cost-effective, efficient performance. They are designed for ease of installation, adaptability, simplicity of operation, ease of maintenance and servicing, energy efficiency, cleanliness and long-term reliability. commercial offices hospitals computer rooms museums clean rooms schools high-tech centres printing plants 2 Nortec RS-Series humidifiers offer complete application flexibility to systems engineers, contractors and customers. They can be integrated into central Heating/Ventilating/Air Conditioning (HVAC) systems or placed in specified locations for individual room control. Models are available to serve small or large areas with outputs of 10 - 180 lbs/hr.

Operating advantages Precise Control All RS-Series humidifiers have an advanced controller with display for precise and efficient relative humidity control. The humidifier can be controlled by a humidistat, a relative humidity sensor or be connected to a central Building Management System (BMS) for maximum control flexibility. RS-Series Outdoor The RS-Series humidifier’s controller provides readout and adjustment of all operating parameters. The humidifier will make service adjustments automatically or trigger a shutdown while displaying the function requiring operator attention. Economy Nortec RS-Series humidifiers provide lower initial installation costs for the customer. Operating costs are also reduced through efficient steam conversion rates and minimal energy losses due to low hot water drain rates. RS-Series humidifiers provide clean humidification, reducing air-borne contaminants and subsequent health-related employee absenteeism. Correct interior humidity levels in winter maintain comfort at lower temperatures and can reduce heating costs. RS-Series RS-Series self-diagnostics confirm optimal operational efficiency and reduce servicing costs. Installation Flexibility RS-Series humidifiers offer unprecedented installation flexibility. They can be configured for both small and large systems. All RS-Series humidifiers are completely packaged for installation ease. The standard drain water cooling ensures drain water does not exceed 140 F (60 C) to meet local plumbing codes. Steam distribution is easily accomplished through either the HVAC duct system or into individual areas through remote blower packs. 3

Technology Resistive Steam The resistive element humidifier offers highest accuracy performance for humidity critical applications. When using the SSR option with a high precision humidistat, the RS-Series can be accurate to 1% RH. The RS-Series is designed for use with potable or DI/RO water. For potable water applications, the unique scale collector tank option saves time and money during cleaning. The base mounted tank collects minerals and is easily removed for disposal of scale. The RS-Series is the most advanced resistive steam humidifier available. It’s high quality heating elements provide the most accurate humidity control available in the world. 4

Features RS-Series with scale collector tank option Display of space RH and set-point Keypad set-point adjustment Network capabilities Cylinder drain 3 day no call Tempered drain during normal and manual operation Alphanumeric function display Keypad programming and status indicator lamps Output display of capacity in lbs/hour P I Control System Auto self test on start up Micro computer electronics Potable water operation DI/RO water operation Stainless Steel cylinder High quality incoloy heating elements Dual float water level control Manual output adjustment On/Off control system Single modulation control Fill cup with 1 inch air gap Safety door interlock switch C-UL-US Listed 30 month limited warranty SSR operation Advanced Scale Management System OnLine-Series for web based monitoring and control Links-Series Building Management System Keep Warm (stand-by heating) Outdoor Units Only Heating and cooling protection Weather proof enclosure Integral design with internal pipe chase Standard Optional 5

Options SOFTWARE STEAM DISTRIBUTION Links-Series BP-Series Nortec Links-Series offers monitoring and control allowing humidifier(s) to communicate to your Building Management System (BMS). The controller is factory installed and is located internally to the humidifier. Simply specify at time of order what operating protocol you are using – BACnet IP, BACnet MSTP, LonWorks or Johnson N2. for in space applications (remote mounted). OnLine-Series Nortec OnLine-Series is a remote interactive communication package that allows web-based contacts to monitor, maintain and control a humidification center from any location worldwide using standard internet connections. This advanced software shows graphic representations of the humidifier and its key parameters (up to 75 functions). 6 AS-Series to distribute atmospheric steam into ducts. AM-Series for use in air handlers or ducts where short steam absorption distance is critical.

Technical data SPECIFICATION RS 010 RS 015 RS 020 RS 030 RS 045 RS 065 RS 090 RS 135 RS 180 Capacity: lbs/hr 0-10 0-15 0-20 0-30 0-45 0-65 0-90 0-135 0-180 Capacity: kg/hr 0-4.5 0-6.0 0-9 0 -13.6 0-20 0-29 0-40 0-61 0-82 Input kW max 3.8 5.1 7.7 11.5 15.3 22.4 30.6 45.9 61.2 Voltage 208-600 208-600 208-600 208-600 208-600 208-600 460-600 460-600 460-600 Phase 1 1 1 1/3 3 3 3 3 3 No. of Stainless Steel Tanks 1 1 1 1 1 1 1 2 2 1-3/4” 4.5 cm 1-3/4” 4.5 cm 1-3/4” 4.5 cm 1-3/4” 4.5 cm 1-3/4” 4.5 cm 1-3/4” 4.5 cm 1-3/4” 4.5 cm 1-3/4” 4.5 cm 1-3/4” 4.5 cm Steam Distribution Choices ** Nortec steam hose I.D. Duct mounted distributors yes yes yes yes yes yes yes yes yes Remote mounted blower packs yes yes yes yes yes yes yes yes yes Short Absorption Manifold (SAM-e) yes yes yes yes yes yes yes yes yes * Capacities are voltage dependant. Output can be field adjusted from 10% to 100% of rated capacity. ** Refer to Engineering Manual for steam distribution methods. 7

As a leading manufacturer of commercial/industrial humidification systems for more than 40 years, Nortec has the technology and application expertise to meet the needs of any application. Contact us today and ensure you have the best humidification solution for your application. USA 1 860 Renaissance Boulevard, Sturtevant, WI 53177 826 Proctor Avenue, Ogdensburg, NY 13669 Canada 2740 Fenton Road, Ottawa, Ontario K1T 3T7 Tel 1.866.NORTEC1 Fax 613.822.7964 Email nortec@humidity.com 14-652 humidity.com Member of the Condair Group

Nortec RS-Series humidifiers provide lower initial installation costs for the customer. Operating costs are also reduced through efficient steam conversion rates and minimal energy losses due to low hot water drain rates. RS-Series humidifiers provide clean humidification, reducing air-borne

Related Documents:

Steam Injection humidifiers from DRI-STEEM use steam from an external source, such as an in-house boiler or a district steam system. DRI-STEEM’s Steam Injection humidifiers are adaptable to virtually any size application, and a wide variety of models accommodate a broad range of

Series Steam Heat Exchanger humidifier. level and safety systems. It also provides a control The "SXDDR" Series humidifiers utilize a stainless steel heat exchanger that allows boiler steam to be used as the heat source for producing steam from tap water. By isolating the boiler steam from the clean tap water, contamination from the boiler is

17 Table 3. Compressed Water and Superheated Steam (continued) 0.01 MPa (ts 45.806 C) 0.02 MPa (t s 60.058 C) 0.03 MPa (t s 69.095 C) v ρh s t, C v h s t, C v ρ h s 26 446. 0.037 814 3076.7 9.2827 300 13 220. 0.075 645 3076.5 8.9625 300 8811.0 0.113 49 File Size: 630KBPage Count: 60Explore furtherCalculator: Superheated Steam Table TLV - A Steam .www.tlv.comSuperheated Steam Tables - Gilson Enggilsoneng.comCalculator: Superheated Steam Table TLV - A Steam .www.tlv.comCalculator: Superheated Steam Table TLV - A Steam .www.tlv.comSteam Table Calculator Superheated Steam Region Spirax .www.spiraxsarco.comRecommended to you b

Nortec SE Series steam exchange humidifiers deliver reliable humidity from the facility steam boiler. Constructed of premium quality 304 and 316 stainless steel, Nortec LS and SE Series are designed for long operating life with minimal maintenance. In hospitals, universities, museums, galleries, and other facilities, boiler steam humidification .

a duct system. The steam discharged from the humidifier is quietly dispersed by a fan without introducing water droplets into the air. DRI-STEEM Steam Injection humidifier in its most elemental form — the Single-tube humidifier. Each Single-tube or .VMUJQMF UVCF IVNJEJGJFS JODMVEJOH Maxi-bank and Mini-bank humidifiers)

The blower pack can be direct-mounted on the Nortec EL series or RS series humidifiers, or mounted remotely with the Nortec EL series, RS series, GS series or the SE series humidifiers. Multiple blower packs can also be installed remotely with large humidifiers. Refer to Figure 1. Figure 1: 1 2 3 Nortec Blower Pack Mounting Configurations

Page 2 June 2015 Large Steam Power Plants Siemens Steam Turbines for coal-fired Steam Power Plants Power output 120 MW to 700 MW Max. steam parameters Main steam / Hot reheat steam 177 bar / 600 ºC / 620 ºC 2,570 psi / 1,110 ºF / 1,150 ºF SST-5000 series for coal-fired Steam Power Plants

academic writing setting and culture in their respective learning establishments do not prepare them for the conventions of English writing. Abbas (2011) investigated metadiscourse terms and phrases to understand the socio-cultural variances of Arabic and English-speaking researchers. Abbas analysed seventy discussions of linguistic academic journals composed by native speakers of Arabic as .