INSTRUMENTATION CABLE CATALOGUE

Wire & Cable Specialists Our Commitment Our commitment to our customers is simple we deliver even when others can’t. As one of Canada’s largest wire, cable and data communication distributors for over 40 years, Texcan supplies solutions for automotive, power distribution, control, industrial automation, commercial, residential, premise wiring and networking applications. Our commitment to superior customer service is the number one reason customers keep coming back. Our parent company, Sonepar, is a major global electrical distributor, with divisions in 40 countries, 5 continents, over 45,000 associates and 2,800 branches. Dedicated to Our Customers Texcan understands that business is done between people. We consider a job finished when the customer is completely satisfied. This approach highlights our commitment to quality and our high level of customer service. This winning combination focuses on a personalized approach to our customers. Product Expertise and Specialized Services Texcan has five stocking locations in Western Canada. With over 200 employees, Texcan is able to provide product application expertise, specialized technical assistance and superior sales service to meet our customers’ needs. We constantly strive to bring value to our customers. We provide: An extensive range of stock wire products Computerized order processing Regionalized bar coded warehousing Competitive pricing Inventory tracking technology JIT inventory Strategic Partnerships Texcan has worked hard to develop partnerships with customers and vendors and continues to be committed to developing such strategic alliances. These partnerships provide Texcan with a successful and proven record with some of the largest customers in the pulp and paper, mining, petrochemical, transportation, and communication industries. Thanks to our relationships with key vendors such as: Prysmian Group, Southwire, Belden, Northern Cables, Deca Cables, and PTI Cables Inc., Texcan is able to offer its customers a diverse selection of quality products. We are confident we can continue to be your successful partner now and in the future. Over 40 Years of Service

Table of Contents Page No. Instrumentation Cable 4 Design Features - Instrumentation 5 Design Features - Armoured Control 6 Instrumentation Armoured Pairs & Triads Instrumentation Tray Unarmoured Pairs & Triads Armoured Control - 20AWG 300V 7 - 18AWG 300V 8 - 16AWG 300V 9 - 18AWG 600V 10 - 16AWG 600V 11 - 20AWG 300V 12 - 18AWG 300V 13 - 16AWG 300V 14 - 16AWG 600V 15 Connectors Technical Information 16-18 - Metric Conversions 19 To Place an Order - For many of the products in the catalogue, you will find everything that you need to place an order. Should you need any assistance or require special orders, please contact your sales representative. A complete list of our sales offices can be found on the back cover of this catalogue. Universal Toll Free Phone: 1.800.665.1025 3

Instrumentation Cable Introduction Instrumentation cable is used extensively by the petrochemical, pulp and paper and other process industries. It is designed to minimize noise and signal interference to deliver clean signals in harsh environments and general manufacturing operations. Designed for use in wet or dry locations, instrumentation cable has a maximum conductor temperature of 90 C and a low temperature rating of -40 C. The cable jacket is resistant to sunlight, moisture and vapor penetration. It is also an economical alternative as the need for conduits and pull boxes is eliminated. Applications Specifications Instrumentation cable can be used in a broad range of applications, especially where the cable may be subjected to mechanical damage and corrosive chemicals. Instrumentation cables can be used in raceways and direct burial applications and can be supported by messenger wire in aerial or outdoor applications. C SA C22.2 No. 239: - Type CIC (Control and Instrumentation Cable) - Type ACIC (Armoured Control and Instrumentation Cable) C SA C22.2 No. 174, hazardous locations (HL), armoured cables only: - Class 1 Zone 1 (Division 1) & Zone 2 (Division 2) - Class II Division 1 & 2 CSA C22.2 No. 75, Thermoplastic (PVC) Insulated Conductors CSA C22.2 No. 38, Thermoset (XLPE) Insulated Conductors CSA FT4 (Vertical Tray Flame Test) Flame Retardant Low Acid PVC Sunlight Resistant -40 C to 90 C (Dry or Wet) Primarily used for control applications, instrumentation cable is recommended where optimal noise rejection is required. Instrumentation cable is available in individually shielded pairs or triads with an overall shield construction. The pairs or triads are isolated from each other and contain separate drain wires for grounding to provide maximum protection from crosstalk and common mode interference. It is also available in aluminum or steel interlocked armour (for mechanical protection), in 300V and 600V. CAUTION NOTICE In case of fire, well maintained early warning smoke detectors will give an alarm long before non-metallic coverings become combustible. However, the Electrical and Electronic Manufacturers Association of Canada has suggested that all purchasers of PVC insulated / jacketed products be advised of the following: Non-metallic coverings of electrical cables can burn and may transmit fire when ignited. Burning non-metallic coverings may emit acid gases which are toxic and may generate dense smoke. Emission of acid gases may corrode metal in the vicinity e.g. sensitive instruments and reinforcing rods in cement. The installer and/or user assumes all liability for the consequences of the installation and/or use of any of the products in violation of any applicable law, regulation, or code. 4 Universal Toll Free Phone: 1.800.665.1025

Design Features Instrumentation IS/OS ARMOURED DRAIN WIRE Conductors - Class B concentric seven stranded soft annealed tinned copper. ARMOUR OVERALL SHIELD Insulation - Cross-linked polyethylene (XLPE) insulation in accordance with CSA Standards C22.2 No. 239 and C22.2 No. 38. Individual Shield - Aluminum foil-polyester tape with XLPE INSULATED CONDUCTOR RIPCORD OUTER JACKET JACKET PAIR / TRIAD SHIELD seven strand tinned copper drain wire for each pair or triad. PAIR / TRIAD DRAIN WIRE Overall Shield - Aluminum foil-polyester tape with seven strand tinned copper drain wire. Jacket Armoured Instrumentation: Inner flame-retardant PVC jacket with a nylon ripcord included for jacket removal. Unarmoured Instrument Tray: Outer low temperature (-40 C), flame-retardant, moisture and sun resistant PVC jacket. Complete cable FT4 rated. Armour - CSA certified interlocking aluminum armour is applied over the jacket. Suitable for use in Hazardous Locations in accordance with CSA 22.2 No. 174. IS/OS DRAIN WIRE OUTER JACKET OVERALL SHIELD RIPCORD XLPE INSULATED CONDUCTOR PAIR / TRIAD SHIELD PAIR / TRIAD DRAIN WIRE Outer Jacket Over Armour - Low temperature (-40 C), flame-retardant, moisture and sunlight resistant PVC jacket applied over the armour. Complete cable FT4 rated. Colour Code Pairs are black, white and alpha numeric coded. Triads are black, white, red and alpha numeric coded. Options Voltage: 150V Polyvinyl Chloride (PVC) insulation Galvanized steel interlocked armour (GSIA) for 16AWG, 18AWG and 20AWG instrumentation cable Non-shielded or overall shielded cables available upon request Coloured outer jacket Other constructions available upon request Accessories Non-hazardous armoured cable connectors Explosion proof (hazardous location) cable connectors Universal Toll Free Phone: 1.800.665.1025 5

Design Features Armoured Control OUTER JACKET INNER JACKET BOND CONDUCTOR FILLERS Conductors - Class B concentric seven stranded soft annealed bare copper. Insulation - Cross-linked polyethylene (XLPE) in accordance with CSA standards C22.2 No. 239 and C22.2 No. 38. Bonding (Ground) Conductor - Class B concentric seven stranded soft annealed bare copper conductor. Jacket - Inner flame-retardant PVC jacket. Armour - CSA certified interlocking aluminum armour is applied over the inner jacket. Suitable for use in Hazardous Locations in accordance with CSA 22.2 No. 174. Outer Jacket - Low temperature (-40 C), flameretardant, moisture and sunlight resistant PVC jacket is applied over the armour. Complete cable FT4 rated. Colour Code - Conductor #1 is white, the remaining conductors are black and numbered. Options Voltage: 300V 18AWG conductors Galvanized steel interlocked armour (GSIA) Unarmoured cables available Shielded cables available upon request Coloured outer jacket Other constructions available upon request Accessories Non-hazardous armoured cable connectors Explosion proof (hazardous location) connectors 6 Universal Toll Free Phone: 1.800.665.1025 TAPE ARMOUR CONDUCTOR INSULATION

DRAIN WIRE OVERALL SHIELD Individual and Overall Shielded 20AWG 300V XLPE/PVC XLPE INSULATED CONDUCTOR RIPCORD OUTER JACKET JACKET PAIR / TRIAD SHIELD SPECIFIC ATIONS CONSTRUC TION CSA C22.2 No. 239 Conductor: 7 strand tinned Class B concentric copper CSA C22.2 No. 174 Insulation: Cross-linked polyethylene (XLPE). Thickness: 0.020 in (0.51 mm) CSA C22.2 No. 38 Individual Shield: Aluminum/polyester tape shield with 7 strand drain wire over each pair or triad CSA FT4 (Vertical Tray Flame Test) Overall Shield: Overall aluminum/polyester tape shield with 7 strand drain wire PAIR / TRIAD DRAIN WIRE Jacket: Flame-retardant Polyvinyl Chloride (PVC) *refer to CE Code for details Armour: Aluminum Interlocked Armour (AIA) Outer Jacket: Low-temperature (-40 C), flame and sunlight resistant Polyvinyl Chloride (PVC), grey HL Options: Galvanized Steel Interlocked Armour (GSIA) Polyvinyl Chloride (PVC) Insulation Overall shielded or non-shielded cables available Other coloured outer jacket and constructions available upon request PAIRS Approximate Diameter (Over) Inner Jacket (in.) Outer Jacket (in.) LB/ MFT KG/ KM Minimum Bend Radius (in.) 0.020 0.256 0.559 127 189 6.7 0.020 0.298 0.602 156 232 7.2 4 0.020 0.452 0.758 234 348 9.0 6 0.020 0.569 0.875 313 465 10.5 C3-9324-2008-19 8 0.020 0.614 0.921 356 530 11.0 C3-9324-2012-19 12 0.020 0.738 1.046 456 678 12.6 C3-9324-2016-19 16 0.020 0.816 1.161 581 864 13.9 C3-9324-2024-19 24 0.020 1.018 1.365 805 1198 16.4 C3-9324-2036-19 36 0.020 1.192 1.560 1076 1601 18.7 C3-9324-2050-19 50 0.020 1.375 1.747 1340 1994 20.9 Part Number No. of Pairs Insulation Thickness (in.) C3-9134-2001-19 1 C3-9334-2002-19 2 C3-9334-2004-19 C3-9334-2006-19 Part Number No. of Pairs Insulation Thickness (in.) C3-9124-2001-19 1 C3-9324-2002-19 2 C3-9324-2004-19 C3-9324-2006-19 Net Weight TRIADS Approximate Diameter (Over) Inner Jacket (in.) Outer Jacket (in.) LB/ MFT KG/ KM Minimum Bend Radius (in.) 0.020 0.268 0.572 136 203 6.9 0.020 0.420 0.725 208 309 8.7 4 0.020 0.485 0.791 267 398 9.5 6 0.020 0.609 0.916 362 538 11.0 C3-9334-2008-19 8 0.020 0.659 0.966 418 622 11.6 C3-9334-2012-19 12 0.020 0.794 1.138 586 872 13.7 C3-9334-2016-19 16 0.020 0.920 1.266 744 1107 15.2 C3-9334-2024-19 24 0.020 1.097 1.445 978 1455 17.3 C3-9334-2036-19 36 0.020 1.344 1.716 1324 1970 20.5 C3-9334-2050-19 50 0.020 1.550 1.922 1670 2486 23.0 Note: A ll dimensions are nominal and are subject to normal manufacturing tolerance. Specifications are subject to change without prior notice. 1 pair / triad overall shielded only. Single pair / triad overall shielded applies to multi-pairs / triads only. Net Weight * See pages 16-18 for corresponding connectors. Universal Toll Free Phone: 1.800.665.1025 7 CON T R OL ARMOUR I S /OS A RMOURED Armoured Instrumentation

CON T R OL I S /OS A RMOURED Armoured Instrumentation DRAIN WIRE ARMOUR OVERALL SHIELD Individual and Overall Shielded 18AWG 300V XLPE/PVC XLPE INSULATED CONDUCTOR RIPCORD OUTER JACKET JACKET PAIR / TRIAD SHIELD SPECIFIC ATIONS CONSTRUC TION CSA C22.2 No. 239 Conductor: 7 strand tinned Class B concentric copper CSA C22.2 No. 174 Insulation: Cross-linked polyethylene (XLPE). Thickness: 0.025 in (0.64 mm) CSA C22.2 No. 38 Individual Shield: Aluminum/polyester tape shield with 7 strand drain wire over each pair or triad CSA FT4 (Vertical Tray Flame Test) Overall Shield: Overall aluminum/polyester tape shield with 7 strand drain wire PAIR / TRIAD DRAIN WIRE Jacket: Flame-retardant Polyvinyl Chloride (PVC) *refer to CE Code for details Armour: Aluminum Interlocked Armour (AIA) Outer Jacket: Low-temperature (-40 C), flame and sunlight resistant Polyvinyl Chloride (PVC), grey HL Options: G alvanized Steel Interlocked Armour (GSIA) Polyvinyl Chloride (PVC) Insulation Overall shielded or non-shielded cables available Other coloured outer jacket and constructions available upon request PAIRS Approximate Diameter (Over) Inner Jacket (in.) Outer Jacket (in.) LB/ MFT KG/ KM Minimum Bend Radius (in.) 0.025 0.296 0.600 147 218 7.2 0.025 0.347 0.651 185 276 7.8 4 0.025 0.555 0.861 307 457 10.3 C3-9324-1806-19 6 0.025 0.658 0.966 385 573 11.6 C3-9324-1808-19 8 0.025 0.713 1.021 446 663 12.3 C3-9324-1812-19 12 0.025 0.902 1.248 670 997 15.0 C3-9324-1816-19 16 0.025 0.997 1.344 794 1181 16.1 C3-9324-1824-19 24 0.025 1.192 1.561 1073 1597 18.7 Part Number No. of Pairs Insulation Thickness (in.) C3-9124-1801-19 1 C3-9324-1802-19 2 C3-9324-1804-19 Net Weight C3-9324-1836-19 36 0.025 1.401 1.772 1416 2107 21.3 C3-9324-1850-19 50 0.025 1.672 2.109 1877 2794 25.3 No. of Pairs Insulation Thickness (in.) TRIADS Part Number Approximate Diameter (Over) Inner Jacket (in.) Outer Jacket (in.) LB/ MFT KG/ KM Minimum Bend Radius (in.) 7.4 C3-9134-1801-19 1 0.025 0.311 0.616 161 239 C3-9334-1802-19 2 0.025 0.498 0.804 253 377 9.6 C3-9334-1804-19 4 0.025 0.610 0.917 363 540 11.0 C3-9334-1806-19 6 0.025 0.727 1.035 464 691 12.4 C3-9334-1808-19 8 0.025 0.788 1.132 586 872 13.6 C3-9334-1812-19 12 0.025 0.997 1.344 821 1222 16.1 C3-9334-1816-19 16 0.025 1.105 1.452 987 1468 17.4 C3-9334-1824-19 24 0.025 1.325 1.695 1354 2014 20.3 C3-9334-1836-19 36 0.025 1.633 2.070 1875 2790 24.8 Note: A ll dimensions are nominal and are subject to normal manufacturing tolerance. Specifications are subject to change without prior notice. 1 pair / triad overall shielded only. Single pair / triad overall shielded applies to multi-pairs / triads only. 8 Net Weight Universal Toll Free Phone: 1.800.665.1025 * See pages 16-18 for corresponding connectors.

DRAIN WIRE OVERALL SHIELD Individual and Overall Shielded 16AWG 300V XLPE/PVC XLPE INSULATED CONDUCTOR RIPCORD OUTER JACKET JACKET PAIR / TRIAD SHIELD SPECIFIC ATIONS CONSTRUC TION CSA C22.2 No. 239 Conductor: 7 strand tinned Class B concentric copper CSA C22.2 No. 174 Insulation: Cross-linked polyethylene (XLPE). Thickness: 0.025 in (0.64 mm) CSA C22.2 No. 38 Individual Shield: Aluminum/polyester tape shield with 7 strand drain wire over each pair or triad CSA FT4 (Vertical Tray Flame Test) Overall Shield: Overall aluminum/polyester tape shield with 7 strand drain wire PAIR / TRIAD DRAIN WIRE Jacket: Flame-retardant Polyvinyl Chloride (PVC) *refer to CE Code for details Armour: Aluminum Interlocked Armour (AIA) Outer Jacket: Low-temperature (-40 C), flame and sunlight resistant Polyvinyl Chloride (PVC), grey HL Options: Galvanized Steel Interlocked Armour (GSIA) Polyvinyl Chloride (PVC) Insulation Overall shielded or non-shielded cables available Other coloured outer jacket and constructions available upon request PAIRS Part Number No. of Pairs Insulation Thickness (in.) Approximate Diameter (Over) Inner Jacket (in.) Outer Jacket (in.) Net Weight LB/ MFT KG/ KM Minimum Bend Radius (in.) C3-9124-1601-19 1 0.025 0.316 0.620 160 238 7.4 C3-9324-1602-19 2 0.025 0.371 0.676 209 311 8.1 C3-9324-1604-19 4 0.025 0.605 0.912 356 529 10.8 C3-9324-1606-19 6 0.025 0.721 1.029 453 674 12.3 C3-9324-1608-19 8 0.025 0.782 1.126 571 849 13.5 C3-9324-1612-19 12 0.025 0.989 1.335 798 1187 16.0 C3-9324-1616-19 16 0.025 1.095 1.442 956 1422 17.3 C3-9324-1624-19 24 0.025 1.313 1.682 1308 1946 20.2 C3-9324-1636-19 36 0.025 1.546 1.918 1976 2940 23.0 C3-9324-1650-19 50 0.025 1.910 2.347 2455 3654 28.1 Part Number No. of Pairs Insulation Thickness (in.) C3-9134-1601-19 1 C3-9334-1602-19 2 C3-9334-1604-19 C3-9334-1606-19 TRIADS Approximate Diameter (Over) Net Weight Minimum Bend Radius (in.) Inner Jacket (in.) Outer Jacket (in.) LB/ MFT KG/ KM 0.025 0.333 0.638 178 265 7.7 0.025 0.567 0.874 311 463 10.5 4 0.025 0.657 0.964 423 629 11.6 6 0.025 0.785 1.130 590 878 13.6 C3-9334-1608-19 8 0.025 0.893 1.239 741 1103 14.9 C3-9334-1612-19 12 0.025 1.079 1.426 986 1467 17.1 C3-9334-1616-19 16 0.025 1.197 1.565 1225 1822 18.8 C3-9334-1624-19 24 0.025 1.439 1.810 1658 2467 21.7 C3-9334-1636-19 36 0.025 1.867 2.304 2494 3711 27.6 Note: A ll dimensions are nominal and are subject to normal manufacturing tolerance. Specifications are subject to change without prior notice. 1 pair / triad overall shielded only. Single pair / triad overall shielded applies to multi-pairs / triads only. * See pages 16-18 for corresponding connectors. Universal Toll Free Phone: 1.800.665.1025 9 CON T R OL ARMOUR I S /OS A RMOURED Armoured Instrumentation

CON T R OL I S /OS A RMOURED Armoured Instrumentation DRAIN WIRE ARMOUR OVERALL SHIELD Individual and Overall Shielded 18AWG 600V XLPE/PVC XLPE INSULATED CONDUCTOR RIPCORD OUTER JACKET JACKET PAIR / TRIAD SHIELD SPECIFIC ATIONS CONSTRUC TION CSA C22.2 No. 239 Conductor: 7 strand tinned Class B concentric copper CSA C22.2 No. 174 Insulation: Cross-linked polyethylene (XLPE). Thickness: 0.030 in (0.76 mm) CSA C22.2 No. 38 Individual Shield: Aluminum/polyester tape shield with 7 strand drain wire over each pair or triad CSA FT4 (Vertical Tray Flame Test) Overall Shield: Overall aluminum/polyester tape shield with 7 strand drain wire PAIR / TRIAD DRAIN WIRE Jacket: Flame-retardant Polyvinyl Chloride (PVC) *refer to CE Code for details Armour: Aluminum Interlocked Armour (AIA) Outer Jacket: Low-temperature (-40 C), flame and sunlight resistant Polyvinyl Chloride (PVC), grey HL Options: Galvanized Steel Interlocked Armour (GSIA) Polyvinyl Chloride (PVC) Insulation Overall shielded or non-shielded cables available Other coloured outer jacket and constructions available upon request PAIRS Part Number No. of Pairs Insulation Thickness (in.) C6-9124-1801-19 1 C6-9324-1802-19 2 C6-9324-1804-19 Approximate Diameter (Over) Net Weight Minimum Bend Radius (in.) 0.030 Inner Jacket (in.) 0.316 Outer Jacket (in.) 0.620 LB/ MFT 155 KG/ KM 231 0.030 0.372 0.676 197 293 8.1 4 0.030 0.591 0.898 328 488 10.8 C6-9324-1806-19 6 0.030 0.703 1.011 413 615 12.1 C6-9324-1808-19 8 0.030 0.762 1.106 519 772 13.3 C6-9324-1812-19 12 0.030 0.965 1.311 721 1073 15.7 C6-9324-1816-19 16 0.030 1.067 1.414 856 1274 17.0 C6-9324-1824-19 24 0.030 1.279 1.648 1161 1727 19.8 C6-9324-1836-19 36 0.030 1.506 1.877 1756 2613 22.5 C6-9324-1850-19 50 0.030 1.880 2.317 2150 3199 27.8 No. of Pairs Insulation Thickness (in.) C6-9134-1801-19 1 C6-9334-1802-19 2 7.4 TRIADS Part Number Approximate Diameter (Over) Net Weight Minimum Bend Radius (in.) Inner Jacket (in.) Outer Jacket (in.) LB/ MFT KG/ KM 0.030 0.333 0.638 171 254 7.7 0.030 0.567 0.874 295 439 10.5 C6-9334-1804-19 4 0.030 0.657 0.964 392 583 11.6 C6-9334-1808-19 8 0.030 0.893 1.239 680 1012 14.9 C6-9334-1812-19 12 0.030 1.125 1.426 919 1367 17.7 Note: A ll dimensions are nominal and are subject to normal manufacturing tolerance. Specifications are subject to change without prior notice. 1 pair / triad overall shielded only. Single pair / triad overall shielded applies to multi-pairs / triads only. 10 Universal Toll Free Phone: 1.800.665.1025 * See pages 16-18 for corresponding connectors.

DRAIN WIRE OVERALL SHIELD Individual and Overall Shielded 16AWG/14 AWG 600V XLPE/PVC XLPE INSULATED CONDUCTOR RIPCORD OUTER JACKET JACKET PAIR / TRIAD SHIELD SPECIFIC ATIONS CONSTRUC TION CSA C22.2 No. 239 Conductor: 7 strand tinned Class B concentric copper CSA C22.2 No. 174 Insulation: Cross-linked polyethylene (XLPE). Thickness: 0.030 in (0.76 mm) CSA C22.2 No. 38 Individual Shield: Aluminum/polyester tape shield with 7 strand drain wire over each pair or triad CSA FT4 (Vertical Tray Flame Test) Overall Shield: Overall aluminum/polyester tape shield with 7 strand drain wire PAIR / TRIAD DRAIN WIRE Jacket: Flame-retardant Polyvinyl Chloride (PVC) *refer to CE Code for details Armour: Aluminum Interlocked Armour (AIA) Outer Jacket: Low-temperature (-40 C), flame and sunlight resistant Polyvinyl Chloride (PVC), grey HL Options: Galvanized Steel Interlocked Armour (GSIA) Polyvinyl Chloride (PVC) Insulation Overall shielded or non-shielded cables available Other coloured outer jacket and constructions available upon request PAIRS Approximate Diameter (Over) Inner Jacket (in.) Outer Jacket (in.) LB/ MFT KG/ KM Minimum Bend Radius (in.) 0.030 0.336 0.640 169 251 7.6 0.030 0.396 0.701 221 329 8.4 4 0.030 0.641 0.948 377 561 11.4 C6-9324-1606-19 6 0.030 0.766 1.109 522 777 13.3 C6-9324-1608-19 8 0.030 0.871 1.216 652 970 14.6 C6-9324-1612-19 12 0.030 1.051 1.398 851 1266 16.8 C6-9324-1616-19 16 0.030 1.165 1.533 1050 1563 18.4 C6-9324-1624-19 24 0.030 1.400 1.770 1400 2083 21.2 C6-9324-1636-19 36 0.030 1.651 2.024 2117 3150 24.3 1 0.030 0.045 0.049 188 280 7.6 Part Number No. of Pairs Insulation Thickness (in.) C6-9134-1601-19 1 C6-9334-1602-19 2 Part Number No. of Pairs Insulation Thickness (in.) C6-9124-1601-19 1 C6-9324-1602-19 2 C6-9324-1604-19 Net Weight 14 AWG C6-9124-1401-19 TRIADS Approximate Diameter (Over) Net Weight Minimum Bend Radius (in.) Inner Jacket (in.) Outer Jacket (in.) LB/ MFT KG/ KM 0.030 0.355 0.638 188 280 7.6 0.030 0.607 0.874 332 494 10.5 C6-9334-1604-19 4 0.030 0.704 0.964 453 674 11.6 C6-9334-1608-19 8 0.030 0.958 1.239 796 1184 14.9 Note: A ll dimensions are nominal and are subject to normal manufacturing tolerance. Specifications are subject to change without prior notice. 1 pair / triad overall shielded only. Single pair / triad overall shielded applies to multi-pairs / triads only. * See pages 16-18 for corresponding connectors. Universal Toll Free Phone: 1.800.665.1025 11 CON T R OL ARMOUR I S /OS A RMOURED Armoured Instrumentation

Instrumentation Tray DRAIN WIRE OUTER JACKET OVERALL SHIELD Individual and Overall Shielded 20AWG 300V XLPE/PVC XLPE INSULATED CONDUCTOR RIPCORD SPECIFIC ATIONS CON T R OL I S /OS CONSTRUC TION PAIR / TRIAD SHIELD PAIR / TRIAD DRAIN WIRE CSA C22.2 No. 230 Conductor: 7 strand tinned Class B concentric copper CSA C22.2 No. 239 Insulation: Flame retardant (FR) Cross-Linked Polyethylene (XLPE), Type RW90 CSA C22.2 No. 38 Individual Shield: Aluminum/polyester tape shield with 7 strand drain wire over each pair or triad CSA FT4 rated (70,000 BTU Vertical Flame Test) Overall Shield: Overall aluminum/polyester tape shield with 7 strand drain wire Outer Jacket: Low-temperature (-40 C), flame and sunlight resistant Polyvinyl Chloride (PVC), black Options: Tinned copper braid shielded cables are available upon request 150V cable Polyvinyl Chloride (PVC) insulation Other coloured outer jacket and constructions available upon request Overall shielded only *refer to CE Code for details TC PAIRS Part Number No. of Pairs Insulation Thickness (in.) Approximate Diameter (in.) Net Weight LB/MFT KG/KM Minimum Bend Radius (in.) 3.0 C3-1124-2001-11 1 0.020 0.256 30 44 C3-1324-2002-11 2 0.020 0.298 48 71 3.5 C3-1324-2004-11 4 0.020 0.452 87 129 5.4 C3-1324-2008-11 8 0.020 0.614 165 245 7.3 C3-1324-2012-11 12 0.020 0.738 230 342 8.8 C3-1324-2016-11 16 0.020 0.816 290 432 9.7 C3-1324-2024-11 24 0.020 1.018 446 664 12.2 C3-1324-2036-11 36 0.020 1.192 627 933 14.3 C3-1324-2050-11 50 0.020 1.672 1068 1589 20.0 No. of Pairs Insulation Thickness (in.) Approximate Diameter (in.) KG/KM Minimum Bend Radius (in.) TRIADS Part Number Net Weight LB/MFT C3-1134-2001-11 1 0.020 0.269 36 54 3.2 C3-1334-2002-11 2 0.020 0.420 69 102 5.0 C3-1334-2004-11 4 0.020 0.486 111 165 5.8 C3-1334-2008-11 8 0.020 0.660 212 316 7.9 C3-1334-2012-11 12 0.020 0.795 300 447 9.5 C3-1334-2016-11 16 0.020 0.922 415 617 11.0 C3-1334-2024-11 24 0.020 1.099 587 874 13.0 Note: A ll dimensions are nominal and are subject to normal manufacturing tolerance. Specifications are subject to change without prior notice. 1 pair / triad overall shielded only. Single pair / triad overall shielded applies to multi-pairs / triads only. 12 Universal Toll Free Phone: 1.800.665.1025 * See page 18 for corresponding connectors.

Instrumentation Tray DRAIN WIRE OUTER JACKET OVERALL SHIELD Individual and Overall Shielded 18AWG 300V XLPE/PVC XLPE INSULATED CONDUCTOR RIPCORD CONSTRUC TION PAIR / TRIAD SHIELD PAIR / TRIAD DRAIN WIRE Conductor: 7 strand tinned Class B concentric copper CSA C22.2 No. 239 Insulation: Flame retardant (FR) Cross-Linked Polyethylene (XLPE), Type RW90 CSA C22.2 No. 38 Individual Shield: Aluminum/polyester tape shield with 7 strand drain wire over each pair or triad C SA FT4 rated (70,000 BTU Vertical Flame Test) Overall Shield: Overall aluminum/polyester tape shield with 7 strand drain wire Outer Jacket: Low-temperature (-40 C), flame and sunlight resistant Polyvinyl Chloride (PVC), black Options: Tinned copper braid shielded cables are available upon request 150V or 600V cable Polyvinyl Chloride (PVC) insulation Other coloured outer jacket and constructions available upon request Overall shielded only *refer to CE Code for details TC PAIRS Part Number No. of Pairs Insulation Thickness (in.) Approximate Diameter (in.) Net Weight LB/MFT KG/KM Minimum Bend Radius (in.) 3.5 C3-1124-1801-11 1 0.025 0.296 42 63 C3-1324-1802-11 2 0.025 0.347 65 96 4.0 C3-1324-1804-11 4 0.025 0.555 132 196 6.6 C3-1324-1808-11 8 0.025 0.713 226 336 8.5 C3-1324-1812-11 12 0.025 0.902 349 520 10.8 C3-1324-1816-11 16 0.025 0.997 440 655 11.9 C3-1324-1824-11 24 0.025 1.192 623 927 14.3 C3-1324-1836-11 36 0.025 1.401 884 1315 16.8 C3-1324-1850-11 50 0.025 1.880 1497 2227 22.5 No. of Pairs Insulation Thickness (in.) Approximate Diameter (in.) KG/KM Minimum Bend Radius (in.) TRIADS Part Number Net Weight LB/MFT C3-1134-1801-11 1 0.025 0.312 51 76 3.7 C3-1334-1802-11 2 0.025 0.499 94 140 5.9 C3-1334-1804-11 4 0.025 0.611 171 255 7.3 C3-1334-1808-11 8 0.025 0.790 302 449 9.4 C3-1334-1812-11 12 0.025 0.999 466 693 11.9 C3-1334-1816-11 16 0.025 1.107 592 881 13.2 C3-1334-1824-11 24 0.025 1.327 847 1260 15.9 Note: A ll dimensions are nominal and are subject to normal manufacturing tolerance. Specifications are subject to change without prior notice. 1 pair / triad overall shielded only. Single pair / triad overall shielded applies to multi-pairs / triads only. * See page 18 for corresponding connectors. Universal Toll Free Phone: 1.800.665.1025 13 CON T R OL CSA C22.2 No. 230 I S /OS SPECIFIC ATIONS

Instrumentation Tray DRAIN WIRE OUTER JACKET OVERALL SHIELD Individual and Overall Shielded 16AWG 300V XLPE/PVC XLPE INSULATED CONDUCTOR RIPCORD SPECIFIC ATIONS CON T R OL I S /OS CONSTRUC TION PAIR / TRIAD SHIELD PAIR / TRIAD DRAIN WIRE CSA C22.2 No. 230 Conductor: 7 strand tinned Class B concentric copper CSA C22.2 No. 239 Insulation: Flame retardant (FR) Cross-Linked Polyethylene (XLPE), Type RW90 CSA C22.2 No. 38 Individual Shield: Aluminum/polyester tape shield with 7 strand drain wire over each pair or triad CSA FT4 rated (70,000 BTU Vertical Flame Test) Overall Shield: Overall aluminum/polyester tape shield with 7 strand drain wire *refer to CE Code for details Options: T inned copper braid shielded cables are available upon request 150V or 600V cable Polyvinyl Chloride (PVC) insulation Other coloured outer jacket and constructions available upon request Overall shielded only Outer Jacket: Low-temperature (-40 C), flame and sunlight resistant Polyvinyl Chloride (PVC), black TC PAIRS Part Number No. of Pairs Insulation Thickness (in.) Approximate Diameter (in.) Net Weight LB/MFT KG/KM Minimum Bend Radius (in.) C3-1124-1601-11 1 0.025 0.316 48 71 3.7 C3-1324-1602-11 2 0.025 0.371 82 122 4.4 C3-1324-1604-11 4 0.025 0.605 167 248 7.2 C3-1324-1608-11 8 0.025 0.782 292 434 9.3 C3-1324-1612-11 12 0.025 0.989 450 669 11.8 C3-1324-1616-11 16 0.025 1.095 571 849 13.1 C3-1324-1624-11 24 0.025 1.313 814 1211 15.7 C3-1324-1636-11 36 0.025 1.546 1165 1733 18.5 No. of Pairs Insulation Thickness (in.) Approximate Diameter (in.) LB/MFT KG/KM Minimum Bend Radius (in.) 0.025 0.025 0.025 0.334 0.568 0.658 60 133 218 90 198 325 4.0 6.8 7.8 TRIADS Part Number C3-1134-1601-11 C3-1334-1602-11 C3-1334-1604-11 1 2 4 Net Weight C3-1334-1608-11 8 0.025 0.895 422 628 10.7 C3-1334-1612-11 12 0.025 1.081 600 893 12.9 C3-1334-1616-11 16 0.025 1.199 769 1144 14.3 C3-1334-1624-11 24 0.025 1.442 1108 1648 17.3 Note: A ll dimensions are nominal and are subject to normal manufacturing tolerance. Specifications are subject to change without prior notice. 1 pair / triad overall shielded only. Single pair / triad overall shielded applies to multi-pairs / triads only. 14 Universal Toll Free Phone: 1.800.665.1025 * See page 16 for corresponding connectors.

Armoured Control OUTER JACKET INNER JACKET BOND CONDUCTOR FILLERS Armoured Control 16AWG 600V XLPE/PVC/AIA/PVC TAPE ARMOUR CONDUCTOR INSULATION SPECIFIC ATIONS CONSTRUC TION CSA FT4 Conductor: Bare copper Class B compressed stranded CSA C22.2 No. 239 Insulation: Cross-Linked Polyethylene (XLPE) Type RW90 CSA C22.2 No. 38 Ground (Bonding) Conductor: Uninsulated stranded bare copper conductor CSA C22.2 No. 174 Inner Jacket: Flame-retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC) Armour: Aluminum Interlocked Armour (AIA) *refer to CE Code for details Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), blue HL Approximate Diameter (Over) AWG Size Part Number No. of Conductors Net Weight w

Instrumentation cables can be used in raceways and direct burial applications and can be supported by messenger wire in aerial or outdoor applications. Primarily used for control applications, instrumentation cable is recommended where optimal noise rejection is required. Instrumentation cable is available in individually

Related Documents:

instrumentation tray cable 10 general purpose cable 12 instrumentation tray exposed run direct burial cable 14 power tray exposed run direct burial cable 16 industrial ethernet cable 18 fieldbus technology cable 20 extremelife cable 22 flexlife cable 24 weldlife cable 26 armorfast instrumentation cable 28 flexible service cable

Catalogue 2020-21 Life Line Plus S3 (HRFR) Cable Life Guard (FR-LSH) Cable Life Shield (HFFR) Cable Multicore Round Cable Shielded Cables Flat Submersible Cable Telephone Switch Board Cable LAN Cable CCTV Cable Co-Axial TV Cable Speaker Cable Presenting Domestic Cable Range for Safer, Securer Homes.

RJ45 Port: Data cable, Ethernet cable, Cat5e, Cat6, Cat6a, Cat7, Cat7a. F-Connector Port: Video cable, coaxial cable, RG6/RG6Q cable, RG59 cable. RJ11/12 Port: Voice cable, POTS (plain old televoice service) cable, 4-wire cable, 6-wire cable, 2 twisted-pair cables, 3 twisted-pair cables, Cat3. VDV SCOUTTM PRO 3 TESTER LOCATION ID REMOTES

Coaxial cable quick reference guide Author: CommScope Subject: Quick reference guide for coaxial cables for hardline trunk, distribution and drop cable applications. Keywords: coaxial cable, hfc network, hybrid fiber coaxial, P3 cable, QR cable, XPRESSPREP cable, BrightWire, hardline cable, trunk cable, drop cable, CATV, CO-112310.1-EN Created Date

DVI and D-sub cable, the DVI cable must be connected along side the rib on the power cord side (Figure 4). 5. For successful cable management, place the cables in this order into the cable management: audio cable (NXM only), power cable, and DVI cable (Figure 5). 6. Place DVI cable, audio cable (NXM only), and power cable into the specific hooks

Cable section: 25: 25mm2 cable 2 35: 35mm cable 50: 50mm2 cable 70: 70mm2 cable Cable length: LXXXX: Cable length (Unit in mm) Remarks: To find the suitable cable for your model, please refer to the in

cable cablevision 0252 cable century 0748 cable citizen 0748 cable cogeco 0752 cable color voice 0848,0948 cable comcast 0752 cable comtronics 0049,0149 . codes for sru3003 and sru3003wm. cable pulsar 0250 cable radio

may be taken on an instrument with only one manual. Consequently, in Grades 1–3, some notes may be transposed or omitted, provided the result is musically satisfactory. Elements of the exam All ABRSM graded Organ exams comprise the following elements: three Pieces; Scales, arpeggios and exercises; Sight-reading (with an additional Transposition exercise in Grades 6–8); and Aural tests .