SST-6000 Steam Turbine Package - Siemens Energy AG

2y ago
190 Views
3 Downloads
7.36 MB
6 Pages
Last View : 8d ago
Last Download : 3m ago
Upload by : Roy Essex
Transcription

SST-6000Steam Turbine PackageThis PDF offers an advanced interactive experience.For the best viewing experience, please use Acrobat Reader X or higher.siemens.com/steamturbines

Siemens SST-6000 seriesOverviewA broad range of turbine modules meet individualrequirements of power ratings and steam parameters.Preassembled modules reduce coordinationeffort, on-site assembly times, and technical risk.The modularized design secures technical replicability.For each project, Siemens customizes the turbinetrain and blade path to ensure optimal performance.Highest reliability and availability are proven by aforced outage rate that is less than half the NorthAmerican Electric Reliability Council (NERC)average.Siemens Steam Turbines of the SST-6000 series arewidely operated in coal-fired steam power plants witha power output up to 1,200 MW and an steam turbineefficiency up to more than 53.7%.Products of the SST-6000 series consist of a high-pressure (HP) turbine, an intermediate-pressure (IP) turbine,and up to three low-pressure (LP) turbines for 50 and 60Hz.The SST-6000 is installed as a high-level arrangementwith down exhaust. Various extractions (up to 10stages) are possible for feed water preheating,process steam, and district heating.5As of June 2015, 488 units of the Siemens SST-6000series are built worldwide.33Double ReheatOn the path to increased efficiency, Siemens doublereheat technology is one smart step towards achieving 54.4% efficiency. It is the optimal solution forapplications used in steam power plants with a poweroutput between 1,000 and 1,350 MW.2164Customer BenefitsAvailability Flexibility PerformanceTrustedPartnerFor us, reliability means living up to whatwe promise.Highest reliability and availability[1] High-pressure turbine[4] Valve[2] Intermediate-pressure turbine[5] Crossover pipe[3] Low-pressure turbines[6] BearingLong maintenance intervals to reduce lifecycle costs

Technical DataGeneratorSGen-3000WReheat steam conditions for single anddouble reheat:Temperature up to 630 C / 1,166 FPower output: 300 MW to 1,200 MW(Double reheat 1,000 MW to 1,350 MW)Efficiency: more than 53.7%(Double reheat 54.4%)Last stage blade length:Frequency: 50 or 60 HzSpeed: 3,000 or 3,600 rpm50 Hz: 66,4 cm to 142,3 cm /26.2 inches to 56 inches60 Hz: 65,5 cm to 95,4 cm /25.8 inches to 37.6 inchesMain steam conditions:Pressure up to 610 bar / 1,130 psiTemperature up to 330 C / 4,786 FApparentpowerInstrumentationand Controls50 Hz60 Hz600 MVA to1,300 MVA600 MVA to1,270 MVAPower factor 0.8 to 0.90.85Efficiencyup to 99%up to 99%Terminalvoltage20 kV to 27 kV 16 kV to 27 kVThe SGen-3000W series features generators withwater-cooled stator windings and hydrogen-cooledrotors. They are the optimal solution for the highestoutput ranges and have a compact design.221435Steam Power Plant Lünen, Germany[1] Blade ring[2] LP turbine blading[3] Turning gear[4] IP turbine blading[5] Push rod

Maintenance of SST-6000Unit Years3years6years9Assemblyyears12years **High-pressure and intermediate-pressure turbinemodules are delivered to site completely assembled.The assembly can also be carried out on-site.Fast and simple on-site installation due to preassembled modules.Minor, medium and major inspections including the 00MinorInspectionInspection100,000 **Thanks to the modular turbine design, Siemenscan flexibly respond to project-specific transportation requirements.MajorInspection[ 10 days ][ 21 days ][ 10 days ][ 35 days ]***First openingof Steam TurbineModules*EOH Equivalent Operating Hours**Estimated values (base load)***Depending on shift mode and customer requirementsMinor InspectionMedium InspectionMajor InspectionVisual inspection of accessible components includingcondenserAuxiliariesNot only the pre-assembled core turbine modulesbut also the provided auxiliary systems are designedfor maximum customer value:Lube oil system, seal oil system, seal steam system,evacuation system, hydrogen system, and additionalsystems.Functional checks on valve and control componentsAlignment checksFunctional checks and visualinspectionOptional: Inspection of non-accessible areas withboroscopeOpening of HP casing:Condenser Evacuation System

Reference examples4Subcritical steam power plant.Iskenderun, Turkey23156[1] Iskenderun, Turkey[2] Niederaußem K, GermanyCommercial operation: 2003Power output*: 2x 660 MW[3] Isogo, Japan[4] Lünen, Germany[5] Waigaoqiao III, China[6] Yuhuan, ChinaSwitch to printable overview*Steam turbine generator

Published by:Siemens Energy, Inc.Power and Gas Division4400 Alafaya TrailOrlando, FL 32826-2399, USACustomer Support Center:Phone 49 / (0) 180 / 524 70 00Fax 49 / (0) 180 / 524 24 71(Charges depending on provider)E-mail: support.energy@siemens.comSubject to changes and errors. The information given inthis document only contains general descriptions and/orperformance features which may not always specificallyreflect those described, or which may undergo modification in the course of further development of the products.The requested performance features are binding onlywhen they are expressly agreed upon in the concludedcontract. 09.2017 Siemens AG

Siemens Steam Turbines of the SST-6000 series are widely operated in coal-fired steam power plants with a power output up to 1,200 MW and an steam turbine efficiency up to more than 53.7%. Products of the SST-6000 series consist of a high-pres-

Related Documents:

Utility steam turbine package Eemshaven, Netherlands Reduced lifecycle costs with the SST-6000 steam turbine Siemens Steam Turbines of the SST 6000 series are widely operated in steam power plants with a power output up to 1,200 MW and net plant efficiencies of more than 46 percent. Turbine

Siemens Energy Sector Power Distribution Power Transmission Oil & Gas/ Industrial Fossil Power Generation Renewable . SST-900 SST-800 SST-700 SST-600 SST 500 SST-400 SST-300 SST-200 SST-100 Figures in MW 1900 1100 1200 700 250 300 200 200 85 10

Siemens Steam Turbine SST-800 Power and Gas This PDF offers an advanced interactive experience. This symbol marks up interactive content. For the best viewing experience, please use Acrobat Reader X or higher. Siemens SST-800 Introduction The SST-800 is a single casing steam turbine with

provider TurboCare. The turbine combines the proven turbine casing of the Siemens SST-400 as well as the steam turboset accessories (gears, generator, base frame) with the geothermal steam path and moisture removal features of the TurboCare Magma turbine fami

Siemens SST-600 The SST-600 is a single-casing steam turbine designed for operation within a speed range of 3,000 to 18,000 rpm for generators or mechanical drives up to 150 MW. The turbine is used for both condensing and back-pressure applications, either geared or directly cou-pled. The customized steam path is arranged

Siemens Steam Turbine SST-3000 Series for combined cycle applications In our Siemens Steam Turbine (SST ) portfolio, we offer with the SST-3000 series steam turbine a compact arrange-ment, that features a two-cylinder design with an axial exhaust for appli-cation in combined c

501 A 120 SST-20-WDS-A120-L2501 501 B 120 SST-20-WDS-B120-L2501 502 A 120 SST-20-WDS-A120-L2502 502 B 120 SST-20-WDS-B120-L2502 L3 560 501 A 120 SST-20-WDS-A120-L3501 . Note 1: The minimum flux of each bin kit is determined by the minimum flux bin as defined

alimentaire Version 2: 11/2018 3 2.16. Un additif repris sur la liste des ingrédients d'un fromage n'est pas un additif autorisé dans le fromage. L'additif est toutefois autorisé dans un ingrédient. L'additif peut-il être présent avec