C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D EProduct Families Covered in this GuideFREEDOM TO CREATE Read the following instructionsbefore operating the luminaire.Lisez les instructions suivantesavant d’utiliser le luminaire.EcoSense Lighting fixtures mustbe installed by a qualifiedelectrician.EcoSense Eclairage doit être installé par unélectricien qualifié.EcoSense Lighting, Inc. is not responsible ifits fixtures are not installed in accordancewith all national and local safety standards.EcoSense Lighting, Inc n’est pas responsable si sonappareils ne sont pas installés conformément àtoutes les normes de sécurité nationales et locales.FOR TYPE L AND TYPE R LISTING MARKS FOR CANADA AND THE U.S.nderwriters Laboratories Inc.MNL-000126-00*MNL-000126-00*registered trademark symbol shall be 3/64 of an inch. When the overall diameter of thef an inch, the trademark symbol may be omitted if it is not legible to the naked eye.s is Helvetica Condensed Black, except for the trademark symbol , which isum. No other fonts are acceptable.HassiumOxygenNeodymiumNitrogenFIXTURE TYPES COVERED IN THIS edSuspendedIntegral Powered FixturesRemote Powered FixturesSingle FixtureContinuous RunTABLE OF CONTENTS1. Tools required2. What’s in the box3. Integral Powered Fixturesa. Overview and Basic Installation Stepsb. Integral powered fixtures: Power Feed Suspension Pointc. Integral powered fixtures: Non-Feed Suspension Pointsd. Integral Powered Wiring Diagram4. Remote Powered Fixturesa. Overview and Basic Installation Stepsb. Remote Powered Fixtures: Power Feed Suspension Pointc. Remote Powered Fixtures: Non-Feed Suspension Pointsd. Remote Powered Wiring Diagram5. Continuous run joining instructions6. EMB & EMW Instructions7. Service and maintenanceuld only be used for UL Classified marine products.SECTION 1.0 TOOLS REQUIRED #2 Phillips Screwdriver 1/4” hex head screwdriver or flat head screwdriver Pliers Wire Cutters Wire Strippers Aircraft Cable Cutters Hex Wrench for Continuous Run Joiner 1/16” 5/64”Hex Wrench for End Caps .050”ECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.1/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D ESECTION 2: WHAT’S IN THE BOXParts Will Vary Depending on Options ChosenPOWER FEED CANOPYANON-POWEREDSUSPENSION& MOUNTING PARTSBLUMINAIRECSUPPLEMENTALITEMSD4in Power Feed Canopy(Integral Driver Fixtures- options #40, #41, #44)Power Feed CanopySuspension & Cable Kit(option #40, #41, #44)4in Power Feed Canopy(Remote Powered Fixtures options #40, #41, #44)‘Zero’ Canopy SurfaceStyle for PSS Cable(Remote Powered Fixtures- option 2ACT)1. Mounting Bar2. Cable Gripper3. Canopy cap sleeve for gripper4. Aircraft Cable (Integral fixtureson cable strain relief bushing(Integral fixtures only)Canopy-Free CableGripper w/cable forNon-Feed SuspensionPoints (option #40)4in Non-Feed Canopy(option #44)Non-Feed CanopySuspension& Cable Kit(option #44)‘Zero’ Canopy MudIn Style for Cable(Remote PoweredFixtures - option 2MIC)1in Non-FeedCanopy & Gripperw/cable (option #41)1. Mounting Bar2. Cable Gripper3. Aircraft Cable4. Canopy cap sleeve for gripperLuminaire (ships pre-assembled)1. Hassium2. Oxygen3. Neodymium4. NitrogenIndividualStart of runRound fixture with rotationalstyle connection shownRemote Driver Housing (ForRemote Power fixtures only)IntermediateEnd of runSquare fixture with single seamstyle connection shownEMB Test Switch& Canopy(For EMB Option)EMB TEST CANOPYECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.2 / 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D ESECTION 3.0: INTEGRAL FIXTURES, OVERVIEWEnsure power is OFFAssurez que la puissance est sur OFF[1](1) POWER FEED SUSPENSION POINT[5][3 & 6](1) AIRCRAFT CABLEPOWER FEED CANOPYNON-POWER FEEDSUSPENSION POINTCANOPY CAP SLEEVE(4) POWER DROPCABLE & STRAINRELIEFBALL END CABLEBALL END CABLE[4][3a]REMOVEABLEEND CAPREMOVEABLE END CAPLUMINAIRE[2][2]RETENTION SLOT FOR BALL ENDRETENTION SLOT FOR BALL ENDSECTION 3.1: INTEGRAL FIXTURES, PLAN THE INSTALLATIONBasic Installation Steps (detailed views & instructions in subsequent sections)NOTES:A. Power Drop Cable is prewired, and strain relieved to luminaire body for integral powered fixtures.B. Aircraft cables for suspension are packed separately and are not preinstalled to the fixture body for integral powered fixtures.1. Install power feed and non-feed suspension points to bldg; adjust cables to desired suspension length [fig 1]2. Prepare fixture for hanging by removing end caps to reveal retention slots for suspension cable ball end [fig 2]3. Sleeve power feed canopy and canopy cap sleeve onto power feed aircraft suspension cable [fig 3]3a. Raise luminaire body and insert ball end cable fittings into retention slots to suspend luminaire body [fig 3a]4. Insert power feed cable and strain relief bushing into canopy [fig 4]5. Make electrical connections at ceiling [fig 5]6. Slide the power feed canopy and cap sleeve to the ceiling [fig 6]ECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.3/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D ESECTION 3.2: INTEGRAL POWERED FIXTURES, POWER FEED CANOPY SUSPENSION POINT1.Screw Mounting Bar [A] to Junctionbox. For 4” square box, use roundmud ring [by others] (as pictured)or alternatively screw mounting bardirectly to 4” octagonal Junction box.2.4-S J-BOX (BY OTHERS)Thread cable gripper [B] intomounting bar3.Push aircraft cable [C] through the3-0 MUD RING (BY OTHERS)NOTE: Mounting Bar alsocan mount directly to 4inOctagon Box (by others)cable gripper.4.[A] MOUNT BARAdjust cable to desired suspension length.[B] CABLE GRIPPER[C] AIRCRAFT CABLESECTION 3.3: INTEGRAL POWERED FIXTURES, NON-FEED SUSPENSION POINTSOption #40 & #41 (Canopy Free and Mini Canopy)Option #44 (4” Canopy)1.Screw Mounting Bar [A] to Junction box. For 4” square1.box, use round mud ring [by others] (as pictured)or alternatively screw mounting bar directly to 4”Fasten a 1/4-20 stud (by others)securely to the ceiling.2.octagonal Junction box.Thread cable gripper ontothe 1/4-20 stud2.Thread cable gripper [B] into mounting bar.3.Push aircraft cable through the cable gripper.the mini canopy4.Adjust cableto desired suspension length.Non-power unit only:between the ceiling and5.Slide canopy [D] & cap sleeve [E] up the aircraft cablethe gripper beforeto complete.threading to the stud.1. For option #41, addAdjust cable length to desired height of fixture.3.Push aircraft cable throughthe cable gripper.[A]4.Adjust cable to desiredsuspension length.[B][D] CANOPYCANOPYCABLE GRIPPER SLEEVE[E]CABLE GRIPPERSLEEVEEnsure power is OFFAssurez que la puissance est sur OFF[C]AIRCRAFT CABLEAIRCRAFT CABLE3 MNL-000126 CS/CSD/CSIECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.4/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D ESECTION 3.4: INTEGRAL FIXTURES, END CAP REMOVAL & BALL END CABLE RETAINER1a1bSet ScrewAircraft Cable2SpringClipRetainer SlotBall EndMagnetic1. Square and rectangular fixtures1. Round Fixtures have springhave magnetic end caps.retained end caps.2. Loosen set screw and pull to2. Pull to remove end cap.1. Ball end cable fits into slottedbracket on fixture for suspensionremove end cap.2a. Allen wrench size: .050”SECTION 3.5: INTEGRAL FIXTURES, POWER FEED CANOPY COMPLETED VIEWNOTE: Mounting Bar also can mount directlyto 4in Octagon Box (by others)ECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.5/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D ESECTION 3.6: INTEGRAL FIXTURE WIRING DIAGRAMWIRING DIAGRAMStandardWiringWD-CS-INT-010VCommonSwitched HotWHITEBLACKGNDGREEN0-10v ( )0-10v (-)PURPLEGRAYPOWER CORD FROM FIXTUREDual Circuit WiringCable Suspended Integral Driver 0-10vWHITE w/BLACKBLACK HITECommon - Top CircuitSwitched Hot - Top CircuitCommon - Bottom CircuitSwitched Hot - Bottom CircuitGND0-10 VOLT DIMMING ( )0-10 VOLT DIMMING (-)0-10 VOLT DIMMING ( )0-10 VOLT DIMMING (-)BottomCircuitTopCircuitPOWER CORD FROM FIXTUREECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.6/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D ESECTION 4.0:REMOTE POWEREDFIXTURES, OVERVIEWREMOTE DRIVER HOUSING[2][2]POWER FEEDSUSPENSION POINT[5]LOW VOLTAGE ELECTRICALCONNECTIONS[7][6][3]NON-FEED CABLE[4] CABLE GRIPPER[1]NON-POWER FEEDSUSPENSION POINTSLEEVE[4] CAP(COVERING CABLEGRIPPER)[8]NON-FEEDCC CAPPOWER FEEDCANOPYLUMINAIRECANOPY CAP SLEEVESECTION 4.1: REMOTE POWERED FIXTURES, PLAN THE INSTALLATIONBasic Installation Steps (detailed views & instructions in subsequent sections)NOTE: PSS Power Feed Cable comes preassembled onto luminiare body for single unit, remotepowered luminaires.1.2.3.Install remote driver housing and make mains electrical and control cable connections [fig 1]Install power feed and non-feed suspension point mountings to bldg. [fig 2]NOTE: FOR N1 and ND1 fixture types, skip step 4 below, and refer to “Section 3.4: Integral Fixtures, End Cap Removal &Ball End Cable Retainer.”1. These fixtures do not use the CC CAP referenced in step 4 below; they have removable end caps.4. Prepare fixture for hanging by unscrewing non feed CC CAP from top of fixture body. [fig 8]1. Feed the non feed aircraft cable [fig 7] through the bottom of the CC Cap until the cable stopper seats into theunderside of the CC CAP2. Next sleeve the cap sleeve [fig4] and non-feed canopy [fig 2] down the free end of the cable3. Now feed the free end of the NON-FEED aircraft cable into gripper at the ceiling suspension point [fig 2]; adjustthis cable to desired suspension length5. Now working on the other end of the fixture body, sleeve power feed canopy [fig 6] and the canopy cap sleeve [fig 3]onto PSS power feed cable (this is the cable that is preassembled to the fixture from the factory)1. Raise luminaire body1. For POWER FEED END of luminaire: insert cable into gripper and adjust cable to desired suspension length [fig 4]2. FOR NON-FEED END of luminaire: screw CC CAP into luminaire body.1. NOTE: FULLY SEAT CC CAP TO FIXTURE BODY IN THIS STEP, BY HAND TIGHTENING THE CC CAPUNTIL ACHEIVING SNUG FIT [fig 8]6. Make Low Voltage electrical connections at ceiling [fig 5]7. Slide the canopies and cap sleeves to the ceiling for all suspension pointsECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.7/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D ESECTION 4.2, REMOTE POWERED FIXTURES: POWER FEED CANOPY SUSPENSION POINT &REMOTE DRIVER HOUSING1. Install the remote driver and attach driver’sconduit onto the junction box.a. Max distance between remote driver &power feed is 100ft (at max run length,12ga wire recommended).a1. For suspended fixtures - subtractsuspension cable drop length from maxrun length.a2. (Example: a fixture with an 8ft cablesuspension length means max distancebetween remote driver and power feedMUD RINGREMOTE DRIVERbecomes 92ft).[A]2. Screw Mounting Bar [A] to JunctionBRACKET BARbox. For 4” square use round mud ring (as[B]pictured) or alternatively screw mounting barCABLE GRIPPERNOTE: Bracket Bar also canmount directly to 4in OctagonBox (by others)directly to 4” octagonal Junction box).3. Thread Cable Gripper Sleeve [E] & Canopy[C] onto aircraft cable.MOUNTING SCREWS[D]CANOPY4. Screw cable gripper [B] into mounting bar5. Push PSS cable [C] through the cablegripper.6. Adjust cable to desired suspension length[E] CABLE GRIPPER SLEEVEPOWERED SUSPENSION SYSTEM(PSS) CABLE7. Strip the PSS cable jacket to expose the wires.[C]8. Connect the wires from remote driver tothe PSS cable.9. Slide Canopy [D] & Cap Sleeve [E] up theaircraft cable to complete.LUMINAIRE1. Remove the 2 screws on each end cap using a 1/4” hex head screwdriver or a flat head screw driver2. Remove the lid (Note: grounding wire is attached to the lid)ECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.8/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D ENon-power unit only:SECTION 4.3, REMOTE POWERED FIXTURES: NON-FEED SUSPENSION POINTSAdjust cable length to desired height of fixture.Option #44 (4” Canopy)1.Screw Mounting Bar [A] to Junction box.For 4” square box, use round mud ring[by others] (as pictured) or alternativelyscrew mounting bar directly to 4”octagonal junction box.2.[A]NOTE: For N1 and ND1 fixture types, referto section 3.4: Integral Fixtures, End CapRemoval & Ball End Cable Retainer.[B]1. These fixtures do not use the CCCAP; they have removable end caps.3.Prepare fixture for hanging byunscrewing non feed CC CAP from top of[C] CANOPYfixture body. [fig F]1. Feed the non feed aircraft cablethrough the bottom of the CC[F]CAP until the cable stopper seats intothe underside of the CC CAP.2. Next, slide the cap sleeve [D] and[D]CABLE GRIPPER SLEEVEnon-feed canopy [C] down the freeend of the cable.4.Screw cable gripper [B] into mounting bar.5.Push aircraft cable through the cable[E] AIRCRAFT CABLEgripper.3 MNL-000127-00 CS-CR, CSD-CR, CSI-CR6.Adjust cable to desired suspension length.7.Slide canopy [C] & cap sleeve [D] up theaircraft cable to complete.Option #40 & #41 (Canopy Free and Mini Canopy)THREADED STUD(BY OTHERS)MINI CANOPY(41 ONLY)1.Fasten a 1/4-20 stud (by others) securely to the ceiling2.Thread cable gripper onto the 1/4-20 studFor option #41, add the mini canopy between theGRIPPERAIRCRAFT CABLEceiling and the gripper before threading to the stud3.Push aircraft cable through the cable gripper4.Adjust cable to desired suspension lengthLUMINAIREECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.9/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

WIRING DIAGRAMC AB LE S U S PE N D E D LU M I NAI R E SIWD-CS-REM-010VN S TA L L ATI O N G U I D ESECTION 4.4, REMOTE POWERED FIXTURES: WIRING DIAGRAMStandard WiringREDREDBLACKBLUERemote Driver HousingWHITEBLACKCommonSwitched HotGREENGNDPURPLEWHITE0-10 VOLT DIMMING ( )0-10 VOLT DIMMING (-)Coaxial Power Cable From FixtureWIRING DIAGRAMWD-CS-REM-010V-DUALDual Circuit WiringCable Suspended Remote Driver 0-10vREDCommonSwitched HotGND0-10 VOLT DIMMING ( )0-10 VOLT DIMMING (-)REDBLACKBLUERemote Driver HousingREDREDBLUE0-10 VOLT DIMMING (-)0-10 VOLT DIMMING ( )GNDSwitched HotCommonBLACKCoaxial Power Cable From FixtureCoaxial Power Cable From FixtureCable Suspended Remote Driver 0-10v DualECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.1 0/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D ESECTION 4.5REMOTE POWERED FIXTURES: ‘ZERO CANOPY’ SERIES, #2ACT- POWER FEED, & NON-FEEDCANOPY SUSPENSION POINT1.Screw ‘Zero’ series mounting plate [A] to 4inch square junction box.2.Adjust threaded cylinder to match ceiling thickness [B]3.Thread magnetized cover plate [C] onto aircraft cable4.Push PSS or standard suspension cable through the cable gripper [D]5.Adjust cable to desired suspension length6.If this is a power feed point1. Strip the PSS cable jacket to expose the wires.2. Connect the wires from remote driver to the PSS cable.7.Slide magnetized cover plate [C] up to the ceiling where it’s retained magnetically[D][B][A]LOW-VOLTAGECABLE[C]SECTION 4.5A‘ZERO CANOPY’ SERIES, #2MIC - POWER FEED & NON-FEED CANOPY SUSPENSION POINT5.If this is a power feed pointa. Strip the PSS cable jacketto expose the wires.b. Connect the wires fromremote driver to the PSS cable.6.[A]Slide magnetized cover plate[C] up to the ceiling where it’sMUD IN PLATEretained magnetically.1.2.3.Screw MUD IN plate [A] to 4inch7.NOTE: To remove cover, push onsquare junction box.one end of cover. This will TILTThread magnetized cover platethe cover on the center axis and[C] onto aircraft cable.allow you to grab it.Push PSS or standard suspensioncable through the cable gripper[D].4.Adjust cable to desiredsuspension length.ECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.11/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

ed on previously installed fixture 1. Tighten two set screws from top of fixture throughclearance holes.C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D ESECTION 5.0JOINING CONTINUOUS RUNS – STYLE #CR: SINGLE SEAM NON-ROTATIONAL1.Make electrical connections between fixtures.2.Slide fixture 2 onto alignment pins [A] locatedSET SCREWS[B]CABLEon previously installed fixture 1.3.Tighten two set screws [B] from top of fixtureALIGNMENT PINSthrough clearance holes.3a. Allen key size: 1/16”, 5/64”[A]FIXTURE 2[C]CONTINUIOUS RUN BRACKETFIXTURE 1SECTION 5.1JOINING CONTINUOUS RUNS – STYLE #CSR: ROTATIONAL1.Connect fixture 2 to fixture 1 by inserting the piston into the knuckle.2.Rotate fixture to desired position3.Tighten set screw [A] in knuckle.3a. Allen key size: 1/16”, 5/64”INTEGRAL POWERED FIXTURE7 MNL-000127-00CS-CR, CABLECSD-CR, CSI-CRAIRCRAFTFIXTURE 1SET SCREWS[A]KNUCKLEREMOTE POWERED FIXTUREFIXTURE 2PISTONECOSENSE LIGHTING INC.P 310 . 496 . 6255837 NORTH SPRING STREETF 310 . 496 . 6256DETAIL BSUITE 103SCALE 1 : 1 T 855 . 632 . 6736855 . 6 . ECOSENLOS ANGELES, CA 90012SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.12 / 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D EREMOTE POWERED FIXTUREPSS CABLE[A]FIXTURE 1FIXTURE 2SET SCREWSPISTONKNUCKLESECTION 6.0EMB OPTION1.2.DETAIL ASCALE 1 : 1Remote powered fixture canopy pictured.Integral powered fixtures (not pictured)have test switch on fixture body.AECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.13/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D EINTEGRAL POWERED FIXTURE EMB WIRINGWHITE w/BLACKBLACK HITEN/AEM Constant PowerCommonSwitched HotGround0-10v Dimming ( )0-10v Dimming (-)2 Port Connector - EMB power(DO NOT DISCONNECT)POWER CORD FROM FIXTUREREMOTE POWERED FIXTURE EMB WIRINGREDREDBLACKBLUEREDBLACK2 Port WagoCommonSwitched HotGroundEM Constant PowerREDBLUERemote Driver Housing0-10v Dimming ( )0-10v Dimming (-)Low Voltage Power Cable From FixtureECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.14/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D EWIRING DIAGRAMSECTION 6.1WD-CS-INT-010V-EMWEMW OPTIONWHITE w/BLACKBLACK HITECommon - EM CircuitSwitched Hot - EM CircuitCommon - Main CircuitSwitched Hot - Main CircuitGND0-10 VOLT DIMMING ( )0-10 VOLT DIMMING (-)0-10 VOLT DIMMING ( )0-10 VOLT DIMMING (-)MainCircuitEMCircuitPOWER CORD FROM FIXTURECable Suspended Integral Driver 0-10v EMWECOSENSE LIGHTING INC.837 NORTH SPRING STREETSUITE 103LOS ANGELES, CA 90012P 310 . 496 . 6255F 310 . 496 . 6256T 855 . 632 . 6736855 . 6 . ECOSENSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT SPECIFICATIONS.FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-PORTFOLIO/ 2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THEECOSENSE LOGO, TRoV, TROV AND ECOSPEC ARE REGISTERED TRADEMARKSOF ECOSENSE LIGHTING INC.1 5/ 17RISE , SLIM COVE , FREEDOM TO CREATE , MACRO , FLIP-TO-FLAT ARETRADEMARKS OF ECOSENSE LIGHTING INC.20200107

C AB LE S U S PE N D E D LU M I NAI R E SI N S TA L L ATI O N G U I D EINSTALLATION CONSIDERATIONSCaution, risk of electric shock.Remarques Concernant L’installationAttention : risque de choc électrique.MIN 90C SUPPLY CONDUCTORSLES FILS D’ALIMENTATION 90C MINCable Suspended Remote Power Unit with Cable Suspended Luminaire / Unité d’alimentation à distance suspendue avec luminaire suspendu par un câbleELECTRICAL RATINGS / CARACTÉRISTIQUES ÉLECTRIQUESOPERATING VOLTAGE / Tension de Fonctionnement120-277VAC, 50/60 Hz, MAX 0.22-0.10A, MAX 26W NOMINAL PER FOOT OF LUMINAIRE HOUSING LENGTH / Puissance nominale par pied de la longuer du boîtier du luminaire347V, 50/60Hz, MAX 26W NOMINAL PER FOOT OF LUMINAIRE HOUSING LENGTH / Puissance nominale par pied de la longuer du boîtier du luminaire347-480V, 50/60Hz, MAX 0.07 - 0.05A, MAX 36W NOMINAL PER FOOT OF LUMINAIRE HOUSING LENGTH / Puissance nominale par pied de la longuer du boîtier du luminaireWhen shipped separately, surface mounted luminaire rated max nominal 600 mA/ ft total or max nominal 24W/ft constant current or max nominal 24 Vdc constant voltageas applicable based on LED array type provided. / Lorsqu’il est expédié séparément, le luminaire monté en surface a une valeur nominale maximale de 600 mA/pied au totalou un courant constant de fréquence nominale maximale de 24 W/pied ou une tension constante nominale maximale de 24 Vcc, selon le cas et la LED et en fonction du typede tableau fourni.Cable Suspended Integral Driver Cable Suspended Luminaire/ Boîtier intégral suspendu par un câble avec luminaire suspendu par un câbleOPERATING VOLTAGE / Tension de Fonctionnement120-277V, 50/60Hz, MAX 0.22-1.10A NOMINAL PER FOOT OF LUMINAIRE / Puissance nominale par pied de la longuer du boîtier du luminaire77 F (25 C)OPERATING TEMPERATURE / Température de Fonctionnement:Refer to electrical rating marked on the luminaire. / Reportez-vous aux caractéristiques électriques indiquées sur le luminaire. Read and understand the installation instructions before attempting to install or use the fixture.Lire et comprendre les instructions d’installation avant de tenter d’installer ou d’utiliser l’appareil. Only use fixtures with voltage for which it is rated. Do not exceed the specified voltage and current input.N’utiliser que des appareils avec une tension pour laquelle il est classé. Ne pas dépasser la tension indiquée et la puissance absorbée. Do not use fixture if the housing, lens, or power cable are damaged.Ne pas utiliser cet appareil si le boîtier, l’objectif ou câble d’alimentation sont endommagés Ensure that main power supply is off before installing or wiring a fixture.Assurez-vous que l’alimentation principale est coupée avant l’installation ou le câblage d’un appareil. Hazardous live parts shall not be accessible after installation, and it is the installer’s responsibility to ensure that the installation/connections are in compliance with nationaland local electrical codes and regulations.Les parties actives dangereuses ne doit pas être accessible après installation, et c’est la responsabilité de l’installateur de s’assurer que l’installation / connexions sont conformesaux codes nationaux et locaux électriques et les règlements The wire connection method shall be determined by local electrical codes and regulations, typically using either wire nuts or screw terminal blocks.La méthode de connexion de fil doit être déterminé par les codes électriques locaux et des règlements, typiquement en utilisant soit les serre-fils ou borniers à vis. Possibly hazardous optical radiation emitted from this product.Peut-être dangereux rayonnement optique émis par ce produ

*mnl-000126-00* installation guide 1/17 20200107 p 310.496.6255 f 310.496.6256 t ecosense855.632.6736 855.6.ecosen ecosense lighting inc. 837 north spring street suite 103 los angeles, ca 0012 rise specifications subject to change without notice. visit e

Related Documents:

FigureSiWS5 TG curves of SiW12-MnL (a), PW12-MnL (b) and PMo12-MnL (c). To further confirm the crystal structures and thermal stabilities, the TG curves of POM-MnL were also researched. As shown in Figure S5, all the POM-MnL can be stable at least 150 oC, taking 12-MnL for example,

Dec 06, 2016 · COMMERCIAL LIGHTING 01-13 14-29 industrial lighting hazardous area lighting cleanroom lighting INDUSTRIAL LIGHTING street lighting area lighting induction lighting landscape lighting CITYSCAPE LIGHTING 30-51 ballast light sources HID lamps spares price list A

43.10 2. 1 53.40 the information contained in this drawing is the sole property of ecosense lighting. any reproduction in part or as a whole without the written permission of ecosense lighting is prohibited. third angle projection interpret according to asme y14.5 angle 1 fraction 1/64

high transmission frosted lensing 84.07mm 84.07mm 3/8 p 310.4966255 f 310.496.6256 t 8556326736 8556.ecosen ecosense lighting inc. 837 north spring street suite 103 los angeles, ca 90012 rise

LIGHTING ( DEFINED ) OPEN AREA (ANTI-PANIC) LIGHTING ( UNDEFINED ) HIGH RISK TASK LIGHTING Emergency lighting standards tree. Escape route lighting. 1.Escape Route Lighting The emergency lighting on a route forming part of the means of escape from a point in a building to final exit. 2.Open Area (Anti-panic) Lighting The part of emergency .

Small Lighting controls 20 80/22 21 Small Lighting-only 20 80/22 18 Large Lighting controls 10 80/31 10 Large Lighting-only 10 80/31 7 2013-2014 Small Lighting controls 40 80/16 42 Small Lighting-only 20 80/22 21 Large Lighting controls 30 80/18 33 Large Lighting-only 10 80/31 10 Total 160 80/15 162

1.3. Related work A basic pillar in the MNL-Bandit problem is the MNL choice model, originally introduced (independently) by Luce [17] and Plackett [25]; see also Train [33], McFadden [19], Ben-Akiva and Lerman [8] for further discussion and survey of other co

worts, lichens, mosses, algae and fungi also occur. CLIMATE : The abrupt variations in the altitude (elevations) have created diverse climatic conditions. The climate is warm and humid during summer and monsoon season (June Oct.) and moderately cold during winter (Dec. Feb.) at lower elevations. The winter months become more severe as one goes up. Places like Lachen, Lachung and Dzongri areas .