Residential & Light CommercialHVAC Solutions2019 LG CanadaEngineering and Specifications Guidewww.lgdfs.ca

ABOUT LGAbout LG Electronics CanadaLG Electronics Canada, Inc., based in Toronto, Ontario, is the Canadian subsidiary of LG Electronics,Inc., a 48 billion global force and technology leader in consumer electronics, home appliances andmobile communications. LG Electronics, named an ENERGY STAR Partner of the Year for manyyears, sells a range of stylish and innovative home entertainment products, mobile phones, homeappliances, commercial displays, air conditioning systems and solar energy solutions in Canada, allunder LG’s “Life’s Good” marketing theme. For more news and information on LG Electronics, pleasevisit www.lgdfs.ca.LG Electronics Canada Air Conditioning TechnologiesThe LG Electronics Canada Air Conditioning Technologies business is based in Toronto,Ontario. LG is a leading player in the global air conditioning market, manufacturing bothcommercial and residential air conditioners and providing total sustainability and buildingmanagement solutions. From consumer and individual units to industrial and specialized airconditioning systems, LG provides a wide range of products for heating, ventilating and airconditioning. For more information, please visit www.lgdfs.ca.1LG Air Conditioning Technologies

DUCT-FREE SYSTEMS:A NEW WAY TO THINKABOUT AIR CONDITIONINGFor truly personalized comfort in all rooms,consider an LG Duct-Free Split air conditioningsystem. LG air conditioning systems makeit easier to provide customized cooling andheating in every room without any bulkywindow units or costly ductwork, and withseveral indoor unit designs sure to matchany décor, LG air conditioning systems canbe right for every job.LG air conditioning systemsare THE smart alternative totraditional air conditioning23 22 24 21 Our Commitment to You:QUALITYLG air conditioning systems reflect our commitment to building high-qualityproducts. Operating several state-of-the-art research & development facilities acrossthe globe, LG invests heavily to ensure we are combining the best technologies withthe best ideas.TRAININGWith LG training academy in Toronto Ontario, LG makes it easy to learn about LGsystems and product applications.PERFORMANCELG makes a wide range of duct-free products with powerful cooling and heatingcapabilities while maintaining high energy efficiencies, quiet operation, ease of usefor personalization of comfort control for the end user.INNOVATIONLG utilizes smart technology to enhance a homeowner's, and the technician’s,experience in operating and providing routine maintenance or service on our airconditioning systems. Our continued efforts to look for the most innovative ideasin HVAC, with our commitment to building green technologies, ensures that we willcontinue to develop and bring to market smarter, sustainable products.2

3LG Air Conditioning Technologies

TABLE OF CONTENTSINTRODUCTIONAbout LGLG AdvantagesTraining & RecognitionInstallation Best PracticesKey Features15789SINGLE ZONE SYSTEMSWall Mounted ART COOL Prestige ART COOL Mirror Gloss White1113144-Way Cassette16High Static Ducted17Low Static Ducted18Vertical AHU19Multi-Zone SYSTEMSOutdoor UnitsIndoor UnitsMulti F MAX Piping AccessoriesMulti F Piping Summary23273132ACCESSORIESControlsIndoor AccessoriesOutdoor Accessories333435REFERENCE TABLESControls & Accessories CompatibilityENERGY STAR SystemsModel Number Nomenclature3638394

LG ADVANTAGESROOM-BY-ROOM CONTROLWith a controller for each indoor unit, LG air conditioningsystems offer precise temperature settings in each zone whilemaximizing energy useage by heating or cooling only thezones in use.21 22 22 23 QUIET OPERATIONIndoor Unit50 dB(A)Conversationat HomeLG duct-free systems operate at low sound levels, thanks toLG’s unique low-vibration compressor, skew fan and brushlessdirect current (BLDC) motor technology that eliminatesunnecessary noise and allows for smooth operation.40 dB(A)60 dB(A)Bird CallsConversationin Restaurant17 dB(A)70 dB(A)VacuumCleanerLG AC Indoor Unitas low as 17 dB(A)Art Cool Premier(Sleep Mode)Noise Level ComparisonTECHNOLOGYInverter, variable-speed, compressor outdoor units use lessenergy and are measurably quieter than conventional airconditioner units. Unlike conventional systems that cycle onand off, an inverter compressor ramps up or down to matchthe capacity needed to maintain comfort levels selectedby the homeowner within a conditioned zone.Conventional ACTemperatureLG ergySaving22dBConventionalInverter19TimedB5LG Air Conditioning Technologies

LG ADVANTAGESLG SMARTTHINQ Whenever, wherever and no matter how many air conditionersyou have, LG SmartThinQ let you easily access and control yourair conditioner from your compatible smart device.1EASY INSTALLATION &NO DUCTWORKLG duct-free systems are designed for easier and moreefficient installation. They require little to no ductwork, andmost indoor units can mount on any wall. Installation requiresonly a small hole to be drilled in the wall. Smaller indoor andoutdoor units ensure space-saving convenience. Moreover, longrefrigerant piping lengths increase the distance between theindoor and outdoor units, allowing for extra installation anddesign flexibility.Indoor Unit /EvaporatorConduit forRefrigerant Lines &WiringOutdoor Unit / CondenserDiagram of a Single Zone SystemAIR QUALITYThe LG duct-free indoor units utilize 3M Micro Protection Filterswhich reduce dust and microscopic particles including pollen, petdander and odors. Additional primary filters are washable andantifungal, reducing life-time operation costs. Indoor units alsoself-clean the coil to protect against mold growth.Self-Cleaning Indoor CoilThe interior of the air conditioner is maintainedby drying off the heat exchanger, eliminatingunwanted mold and odors.3M Micro Protection Filter, a high air flow filterwith low noise, collects harmful microscopicsubstances including pollen and fine dust.Air FilterThis primary filter captures dust size over 10μm.1. LG SmartThinQ is only available for select models. See product details for full compatibility.6

TRAINING & RECOGNITIONTrainingThe LG Canada Air Conditioning division is headquartered in Toronto, Ontario, along with a full training academy. Since 2013, ouracademies have trained hundreds on the advantages of LG air conditioning systems. World class trainers with years of experienceteach classes in duct-free technology, with topics covering everything from installation to service for the full range of LG airconditioning products. LG also has a number of strategically placed partner academies throughout the United States that offer anumber of LG training classes as well.Service ToolsAs part of our commitment to innovation, LG has developed innovative ways to enhance the service technician’s experience duringroutine maintenance or service with these tools: LG SIMS (Smart Inverter Monitoring System) connects to select outdoor units and allows technicians to troubleshootaccurately by interfacing directly with the unit and following step-by-step troubleshooting guidelines. This is a free smartphoneapp developed by LG factory engineers.AHRI Performance AwardsPTAC AwardVRF AwardWCCL AwardUSAC AwardUSHP AwardLG's continuous excellence recognized at AHRI performance awards7LG Air Conditioning TechnologiesACCL Award

INSTALLATION BEST PRACTICESFor jobs small to large, look for opportunities to use LG comfort systems everywhere! Explore the many applications of LG Single andMulti-Zone systems: whole home renovations, older system replacements, home additions, energy savings opportunities, hot or coldzones and many, many more!System sizing and installation accuracy are key factors for the optimal performanace of a LG comfort system. Increased energyefficiency, customizable design aesthetics and room by room comfort control are just a few of the benefits that come from aproperly installed system.Below are a few of the best practices used by Excellence Contractors across the U.S. during installation:Unit Placement (Indoor & Outdoor) Leave appropriate clearances on all sides of theindoor and outdoor units to allow for properairflow as well as service access Include space for drainage to ensure condensateflows properly out of the unit Units should be properly anchored to preventunnecessary vibrationsAdditionally for indoor units: Keep unit away from any indoor steam orexcessive heat No obstacles should be placed around unit Do not install near a doorway or over a window Condensation drain should be routed awayfrom the indoor unit to the outsideWiring Use wire that fulfills or exceeds the minimumwire requirements: Multi F MAX to BD unit: 16-4 All other wiring: Follow local guidelines L1 and L2 are polarity sensitive on all models Indoor units are 208/230 volts Never use wire nuts or splices in wiring Use non-insulated spade connectors on all terminal connections Use a JIS screwdriver on terminal block to avoidstripping out the screws Only a dedicated electrical circuit is allowed Always ground indoor and outdoor unit Only connect one (1) end of the shielded cable if using shielded wire*NOTE* All wiring must comply with applicable local and national codes.ChargingPiping Use only the correct line sizes as determined bythe indoor unitUse only copper refrigerant pipingInsulate both refrigerant lines independentlyof each otherFlare connections using a 45-degree flaring toolConsider Flaretite fittings for all connections andtorque flares to specsDo not exceed the maximum pipe length or installless than the required minimumDo not make vertical loops in the refrigerant pipingSupport pipe runs from sagging or bending Leak test with dry nitrogen to at least 550 p.s.i. Never use anything but soap bubbles designed forHVAC leak testing Use only an approved evacuation hose for proper evacuationand leak testing If possible, remove cores from system prior to startingevacuation Start with fresh vacuum pump oil and evacuate toless than 500 microns If refrigerant is added, use an electronic scale andweigh in the precise amount Open service valves prior to energizing the unitInstallation and Service Tools: Quality Flaring Tool Digital Refrigerant Charging Scale Torque Wrench Phillips Screwdriver Micron GaugeVacuum PumpHigh-Quality Multimeter8

KEY FEATURESLGHHV HEAT TECHNOLOGYDEHUMIDIFYING MODEAdvanced technology that canexceed 100% of the rated heatingcapacity performance down to-15 C and continuous heatingperformance down to -25 C.Uses sensors in the indoorunit to accurately measureroom temperature and controlhumidity by adjusting the setpoint and fan speed.HHVOPTIMIZED AIRFLOW-4 cJet Cool / Jet Heat Mode operates the unit at a high speedfor up to 30 minutes to quickly cool or heat a room.Swirl Wind / Chaos Wind allows for customizedlouver and fan speed operation to create a stronger,wider airflow for reduced temperature stratificationand to provide more natural air circulation.Auto Operation adjusts the temperature and fan speedautomatically to match the user’s preference fromthree levels of comfort.9GOLD FINDEFROST CONTROLGold Fin Coating is ananticorrosion coating to helpprotect your system from corrosiveelements, allowing the coil tomaintain excellent heat transferproperties for an extended time.Removes frost from the outdoor coilwhen ambient outdoor temperaturesare low and simultaneouslyAutomashutsticVoltagedown the indoor fan to preventSwitchercold air from being blown intothe controlled space.AUTO SLEEP MODEAUTO RESTARTAutomatically increases thetemperature setting 2 F twicein 30 minute increments.The indoor unit shuts off whenthe timer setting is reached.Automatically restarts thesystem after a power failure.LG Air Conditioning TechnologiesRestartin 3 min

SINGLE ZONESINGLE ZONE 180HSV5LS243HLVLong PipingLS303HLVLong PipingLS363HLVLong VLH367HVLV240HV4LV360HV442,00048,000ART COOL PrestigeART COOL MirrorCeiling MountedGloss White4-WayCassetteLC427HVDuctedHigh StaticLow StaticLD097HV4LD127HV4LD187HV4Vertical AHULV180HV4LV420HVLV480HV10

ART COOL tIndoor UnitOutdoor UnitCapacityLAU120HYV9,00011,00015,000Cooling Capacity RangeRated Heating CapacityBtu/hBtu/h1,023 12,96611,0001,023 13,78512,0003,070 21,00018,000Heating Capacity RangeBtu/h1,023 20,4721,023 22,1783,070 25,200Max Heating Capacity at -8.3 CBtu/h11,94014,65021,430Max Heating Capacity at -15 CBtu/h11,22013,72018,950Max Heating Capacity at -25 CBtu/h7,9209,52014,66027.5, 15.6525.5, 13.7524.0, 13.48121212.5Voltage (IDU)V, Ø, Hz208/230-1-60208/230-1-60208/230-1-60Voltage (ODU)V, Ø, Hz208/230-1-60208/230-1-60208/230-1-60Cooling Power InputkW0.580.81.11Heating Power InputkW0.710.751.39A11.2, 1511.2, 1519.0, 25Power/Communication Wiring4Rated Amps Cool/HeatNo. x AWG4 x 184 x 184 x 18A8.7/8.78.7/8.715.0/15.0Heating Operation Range C WB-25 18.3-25 18.3-25 18.3Cooling Operation Range C DB-10 47.8-10 47.8-10 47.8Optional Wind Baffle6WeightUnit DataPAG-HS0 / PAG-HS3PAG-HS0 / PAG-HS3PAG-HS2 / PAG-HS8IDU Operation Range Cooling C WB11.7 23.911.7 23.911.7 23.9IDU Operation Range Heating C DB15.5 3015.5 3015.5 30Setpoint Range Cooling C17.8 3017.8 3017.8 30Setpoint Range Heating C15.5 3015.5 3015.5 30IDU Dimensions 2-15/16x12-31/32x9-25/32ODU Dimensions /1634-1/4 x 31-1/2 x 12-19/32IDU Weight (Net/Shipping)lbs24/3024/3034/38ODU Weight (Net/Shipping)lbs77/8277/82122/131Airflow 5/424/318Dehumidificationpts/hr3.203.603.80Twin RotaryTwin RotaryTwin RotaryCompressor TypeRefrigerant TypeSound or MaxdB(A)454557in1/41/43/8Vapor Pipein3/83/85/8Pipe Length (Min/Max)ft6.6/65.66.6/65.69.8/98.4Max Pipe Elevationft32.832.865.6Precharge Pipe Lengthft414124.6Additional Refrigerantoz/ft0.220.220.38in27/32, 5/827/32, 5/827/32, 5/8AKB73835320AKB73835320AKB74955602Drain (OD, ID)ControllerR410A42/36/25/17Indoor (H/M/L/SL)Liquid PipePipingLAU150HYV2LAU090HYV1MCA, g RangeLA120HYVLAN120HYVRated Cooling CapacitySEER, EERPowerLA090HYV1LAN090HYV1SuppliedNote:1. Rated capacity at 0 ft. above sea level with 25 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor unit.2. Rated cooling capacity obtained with air entering the indoor unit at 26.7 C dry bulb (DB) and 19.4 C wet bulb (WB) and outdoor ambient conditions of 35 C dry bulb (DB) and 23.8 C wet bulb (WB).Rated heating capacity obtained with air entering the indoor unit at 21.1 C dry bulb (DB) and 15.6 C wet bulb (WB) and outdoor ambient conditions of 8.3 C dry bulb (DB) and 6.1 C wet bulb (WB).For capacity information, see engineering manual capacity tables.3. All power/communication wiring minimum 4-conductor, stranded, shielded, and must comply with applicable local and national codes.4. Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to -17.7 C in cooling mode for applicable outdoor units.5. Airflow shown is in cooling mode.6. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the same in both cooling and heating mode. These values can increase due to ambient conditions during operation.7. Piping lengths are equivalent.8. Due to our commitment to continued innovation, some specifications may be changed without notification.11LG Air Conditioning Technologies

LA180HYV1LA240HYV1SpecificationUnitIndoor UnitOutdoor UnitCapacity22,000Cooling Capacity RangeBtu/h3,070 29,5153,070 30,000Rated Heating CapacityBtu/h22,00027,000Heating Capacity RangeBtu/h3,070 30,7093,070 35,200Max Heating Capacity at -8.3 CBtu/h22,34027,410Max Heating Capacity at -15 CBtu/h19,30023,690Max Heating Capacity at -25 CBtu/h14,06017,25024, 13.4822, 12.51312.3Voltage (IDU)V, Ø, Hz208-230, 1, 60208-230, 1, 60Voltage (ODU)V, Ø, Hz208-230, 1, 60208-230, 1, 60Cooling Power InputkW1.351.76Heating Power InputkW1.692.19A19, 2519, 25Power/Communication Wiring3Rated Amps Cool/HeatNo. x AWG4 x 184 x 18A15.3/15.315.3/15.3Heating Operation Range C WB-25 18.3-25 18.3Cooling Operation Range C DB-10 47.8-10 47.8Optional Wind Baffle4WeightUnit DataPAG-HS2 / PAG-HS8PAG-HS2 / PAG-HS8IDU Operation Range Cooling C WB11.7 23.911.7 23.9IDU Operation Range Heating C DB15.5 3015.5 30Setpoint Range Cooling C17.8 3017.8 30Setpoint Range Heating C15.5 3015.5 30IDU Dimensions (WxHxD)in42-15/16 x 12-31/32 x 9-25/3242-15/16 x 12-31/32 x 9-25/32ODU Dimensions (WxHxD)in34-1/4 31-1/2 12-19/3234-1/4 31-1/2 12-19/32IDU Weight (Net/Shipping)lbs34/3834/38ODU Weight (Net/Shipping)lbs122/131122/131Airflow r3.804.70Twin RotaryTwin RotaryCompressor TypeRefrigerant TypeSound door MaxdB(A)5757in3/83/8Vapor Pipein5/85/8Pipe Length (Min/Max)ft9.8/98.49.8/98.4Max Pipe Elevationft65.665.6Precharge Pipe Lengthft24.624.6Additional Refrigerantoz/ft0.380.38in27/32, 5/827/32, 5/8AKB74835304AKB74835304Drain (OD, ID)Controller777/565/424/318Indoor (H/M/L/SL)Liquid PipePipingLAU240 HYV118,200MCA, MOCPDimensionsLAU180HYV1Btu/hHSPFOperating RangeLA240HYV1LAN240HYV1Rated Cooling CapacitySEER, EERPowerLA180HYV1LAN180HYV1SuppliedNote:1. Rated capacity at 0 ft. above sea level with 25 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor unit.2. Rated cooling capacity obtained with air entering the indoor unit at 26.7 C dry bulb (DB) and 19.4 C wet bulb (WB) and outdoor ambient conditions of 35 C dry bulb (DB) and 23.8 C wet bulb (WB).Rated heating capacity obtained with air entering the indoor unit at 21.1 C dry bulb (DB) and 15.6 C wet bulb (WB) and outdoor ambient conditions of 8.3 C dry bulb (DB) and 6.1 C wet bulb (WB).For capacity information, see engineering manual capacity tables.3. All power/communication wiring minimum 4-conductor, stranded, shielded, and must comply with applicable local and national codes.4. Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to -17.8 C in cooling mode for applicable outdoor units.5. Airflow shown is in cooling mode.6. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the same in both cooling and heating mode. These values can increase due to ambient conditions during operation.7. Piping lengths are equivalent.8. Due to our commitment to continued innovation, some specifications may be changed without notification.12SINGLE ZONEART COOL PRESTIGE

ART COOL city1,2UnitLA090HSV5LA120HSV5LA180HSV5Indoor UnitOutdoor UnitRated Cooling U120HSV512,000LAN180HSV5LSU180HSV518,000Cooling Capacity RangeBtu/h1,023 12,6251,023 13,7853,070 29,515Rated Heating CapacityBtu/h10,90013,600Heating Capacity RangeMax Heating Capacity at -8.3 CBtu/h1,023 17,061Btu/h11,08013,81022,340Max Heating Capacity at -15 CBtu/h9,57011,93019,300Max Heating Capacity at -20 CBtu/h8,31010,36016,760SEER, EERBtu/h23.5, 14.5222.7, 12.521.5, 12.5811.311.410.2Voltage (IDU)V- Ø - Hz208/230-1-60208/230-1-60208/230-1-60Voltage (ODU)208/230-1-60HSPFPowerV- Ø - Hz208/230-1-60208/230-1-60kW0.620.961.43Heating Power InputkW0.711.041.7313, 20A10, 1510, 15No. x AWG4 x 184 x 184 x 18Rated Amps (Cool/Heat)A7.4/7.47.4/7.49.85/9.85Heating Operation Range C WB-20 18.3-20 18.3-20 18.3Cooling Operation Range C DB-10 47.8-10 47.8-10 47.8PAG-HS0 / PAG-HS3PAG-HS0 / PAG-HS3PAG-HS2 / PAG-HS8Power/Communication Wiring3Optional Wind Baffle4DimensionsWeightUnit DataIDU Operation Range Cooling C11.7 23.911.7 23.911.7 23.9IDU Operation Range Heating C15.5 3015.5 3015.5 30Setpoint Range Cooling C17.8 3017.8 3017.8 30Setpoint Range Heating C15.5 3015.5 3015.5 30IDU Dimensions (WxHxD)in32-15/16 x 12-1/8 x 7-9/1632-15/16 x 12-1/8 x 7-9/1639-9/32 x 13-19/32 x 8-11/32ODU Dimensions (WxHxD)in30-5/16 x 21-1/2 x 11-5/1630-5/16 x 21-1/2 x 11-5/1634-1/4 x 31-1/2 x 12-19/32IDU Weight (Net/Shipping)lbs20.5 / 25.620.5 / 25.629.8 / 36.4ODU Weight (Net/Shipping)lbs74.1 / 78.974.1 / 78.9116.8 / 126.5Airflow (Max/H/M/L)5CFM459 / 338 / 317 / 194459 / 338 / 317 / 194706 / 530 / 477 / 371Dehumidificationpts/hr2.72.75.5Twin RotaryTwin RotaryTwin RotaryCompressor TypeRefrigerant TypeSound Pressure6R410AR410A39 / 33 / 23 / 1945 / 40 / 35 / 29dB(A)Outdoor MaxdB(A)484853in1/41/43/8Vapor Pipein3/83/85/8Pipe Length (Min/Max)ft9.8 / 829.8 / 829.8 / 114.8Max Pipe Elevationft49.249.249.2Precharge Pipe Lengthft414124.6Additional Refrigerantoz/ft0.220.220.38in27/32, 5/827/32, 5/827/32, 5/8AKB74955602AKB74955602AKB74955602Drain (OD, ID)ControllerR410A39 / 33 / 23 / 19Indoor (H/M/L/SL)Liquid PipePiping721,6003,070 38,898Cooling Power InputMCA, MOCPOperation Range1,023 22,178SuppliedNote:1. Rated capacity at 0 ft. above sea level with 25 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor unit.2. Rated cooling capacity obtained with air entering the indoor unit at 26.7 C dry bulb (DB) and 19.4 C wet bulb (WB) and outdoor ambient conditions of 35 C dry bulb (DB) and 23.8 C wet bulb (WB).Rated heating capacity obtained with air entering the indoor unit at 21.1 C dry bulb (DB) and 15.6 C wet bulb (WB) and outdoor ambient conditions of 8.3 C dry bulb (DB) and 6.1 C wet bulb (WB).For capacity information, see engineering manual capacity tables.3. All power/communication wiring minimum 4-conductor, stranded, shielded, and must comply with applicable local and national codes.4. Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to -17.8 C in cooling mode for applicable outdoor units.5. Airflow shown is in cooling mode.6. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the same in both cooling and heating mode. These values can increase due to ambient conditions during operation.7. Piping lengths are equivalent.8. Due to our commitment to continued innovation, some specifications may be changed without notification.13LG Air Conditioning Technologies

SINGLE ZONEGLOSS ndoor UnitOutdoor UnitCapacity1,2Btu/h9,00012,00018,000Btu/h1,023 12,6251,023 13,7853,070 29,515Rated Heating CapacityBtu/h10,90013,60021,600Heating Capacity RangeMax Heating Capacity at -8.3 CBtu/h1,023 17,0611,023 22,1783,070 38,898Btu/h11,08013,81022,340Max Heating Capacity at -15 CBtu/h9,57011,93019,300Max Heating Capacity at -20 CBtu/h8,31010,36016,760SEER, EERBtu/h23.5, 14.5222.7, 12.521.5, 12.5811.311.410.2Voltage (IDU)V- Ø - Hz208/230-1-60208/230-1-60208/230-1-60Voltage (ODU)208/230-1-60V- Ø - Hz208/230-1-60208/230-1-60Cooling Power InputkW0.620.961.43Heating Power InputkW0.711.041.7313, 20A10, 1510, 15No. x AWG4 x 184 x 184 x 18Rated Amps (Cool/Heat)A7.4/7.47.4/7.49.85/9.85Heating Operation Range C WB-20 - 18.3-20 - 18.3-20 - 18.3Cooling Operation Range C DB-10 47.8-10 47.8-10 47.8Power/Communication Wiring3Optional Wind Baffle4DimensionsWeightUnit DataPAG-HS0 / PAG-HS3PAG-HS0 / PAG-HS3PAG-HS2 / PAG-HS8IDU Operation Range Cooling C11.7 23.911.7 23.911.7 23.9IDU Operation Range Heating C15.5 3015.5 3015.5 30Setpoint Range Cooling C17.8 3017.8 3017.8 30Setpoint Range Heating C15.5 3015.5 3015.5 30IDU Dimensions (WxHxD)in32-15/16 x 12-1/8 x 7-7/1632-15/16 x 12-1/8 x 7-7/1639-9/32 x 13-19/32 x 8-9/32ODU Dimensions (WxHxD)in30-5/16 x 21-1/2 x 11-5/1630-5/16 x 21-1/2 x 11-5/1634-1/4 x 31-1/2 x 12-19/32IDU Weight (Net/Shipping)lbs18.3 / 23.418.3 / 23.425.6 / 32.2ODU Weight (Net/Shipping)lbs74.1 / 78.974.1 / 78.9116.8 / 126.5Airflow (Max/H/M/L)5CFM459 / 338 / 317 / 194459 / 338 / 317 / 194706 / 530 / 477 / 371Dehumidificationpts/hr2.72.75.5Twin RotaryTwin RotaryTwin RotaryCompressor TypeRefrigerant TypeSound Pressure6R410AR410A39 / 33 / 23 / 1945 / 40 / 35 / 29dB(A)Outdoor MaxdB(A)484853in1/41/43/8Vapor Pipein3/83/85/8Pipe Length (Min/Max)ft9.8 / 829.8 / 829.8 / 114.8Max Pipe Elevationft49.249.249.2Precharge Pipe Lengthft414124.6Additional Refrigerantoz/ft0.220.220.38in27/32, 5/827/32, 5/827/32, 5/8AKB74955602AKB74955602AKB74955602Drain (OD, ID)ControllerR410A39 / 33 / 23 / 19Indoor (H/M/L/SL)Liquid PipePiping7LS180HSV5LSN180HSV5LSU180HSV5Cooling Capacity RangeMCA, MOCPOperation RangeLS120HSV5LSN120HSV5LSU120HSV5Rated Cooling liedNote:1. Rated capacity at 0 ft. above sea level with 25 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor unit.2. Rated cooling capacity obtained with air entering the indoor unit at 26.7 C dry bulb (DB) and 19.4 C wet bulb (WB) and outdoor ambient conditions of 35 C dry bulb (DB) and 23.8 C wet bulb (WB).Rated heating capacity obtained with air entering the indoor unit at 21.1 C dry bulb (DB) and 15.6 C wet bulb (WB) and outdoor ambient conditions of 8.3 C dry bulb (DB) and 6.1 C wet bulb (WB).For capacity information, see engineering manual capacity tables.3. All power/communication wiring minimum 4-conductor, stranded, shielded, and must comply with applicable local and national codes.4. Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to -17.8 C in cooling mode for applicable outdoor units.5. Airflow shown is in cooling mode.6. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the same in both cooling and heating mode. These values can increase due to ambient conditions during operation.7. Piping lengths are equivalent.8. Due to our commitment to continued innovation, some specifications may be changed without notification.14

GLOSS WHITE Long oor UnitOutdoor UnitCapacityBtu/h22,00030,00033,000Btu/h3,070 29,5153,070 34,0003,070 34,000Rated Heating CapacityBtu/h27,00032,00035,200Heating Capacity RangeMax Heating Capacity at -8.3 CBtu/h3,070 38,8983,070 38,8983,070 38,898Btu/h27,41032,49035,740Max Heating Capacity at -15 CBtu/h23,69028,08030,890Max Heating Capacity at 20 CBtu/h20,58024,39026,82021.5, 12.519.0, 10.017.5, 8.181110.010Voltage (IDU)V, Ø, Hz208/230-1-60208/230-1-60208/230-1-60Voltage (ODU)V, Ø, Hz208/230-1-60208/230-1-60208/230-1-60Cooling Power InputkW1.763.004.04Heating Power InputkW2.383.103.84A19, 3019, 3019, 30MCA, MOCPRecommended FusePower/Communication Wiring3Rated Amps Cool/HeatA252525No. x AWG4 x 184 x 184 x 1814.85/14.85A14.85/14.8514.85/14.85Heating Operation Range C WB-20 - 18.3-20 - 18.3-20 - 18.3Cooling Operation Range C DB-10 47.8-10 47.8-10 47.8Optional Wind Baffle4DimensionsWeightUnit DataPAG-HS2 / PAG-HS8PAG-HS2 / PAG-HS8PAG-HS2 / PAG-HS8IDU Operation Range Cooling C WB11.7 23.911.7 23.911.7 23.9IDU Operation Range Heating C DB15.5 3015.5 3015.5 30Setpoint Range Cooling C17.8 3017.8 3017.8 30Setpoint Range Heating C15.5 3015.5 3015.5 30IDU Dimensions 646-7/8x13-5/8x10-7/16ODU Dimensions /3234-1/4x31-1/2x12-19/32IDU Weight (Net/Shipping)lbs40/4640/4640/46ODU Weight (Net/Shipping)lbs125/133125/133125/133Airflow 48/706/530Dehumidificationpts/hr5.55.96.6Twin RotaryTwin RotaryTwin RotaryCompressor TypeRefrigerant TypeSound or MaxdB(A)555555in3/83/83/8Vapor Pipein5/85/85/8Pipe Length (Min/Max)ft9.84/1649.84/1649.84/164Max Pipe Elevationft98.498.498.4Precharge Pipe Lengthft24.624.624.6Additional Refrigerantoz/ft0.380.380.38in27/32, 5/827/32, 5/827/32, 5/8AKB74955602AKB74955602AKB74955602Drain (OD, ID)ControllerR410A49/44/40/37Indoor (H/M/L/SL)Liquid PipePipingLS363HLVLSN363HLVLSU363HLVRated Cooling CapacityHSPFOperating RangeLS303HLVLSN303HLVLSU303HLVCooling Capacity RangeSEER, EERPowerLS243HLVLSN243HLVLSU243HLVSuppliedNote:1. Rated capacity at 0 ft. above sea level with 25 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor unit.2. Rated cooling capacity obtained with air entering the indoor unit at 26.7 C dry bulb (DB) and 19.4 C wet bulb (WB) and outdoor ambient conditions of 35 C dry bulb (DB) and 23.8 C wet bulb (WB).Rated heating capacity obtained with air entering the indoor unit at 21.1 C dry bulb (DB) and 15.6 C wet bulb (WB) and outdoor ambient conditions of 8.3 C dry bulb (DB) and 6.1 C wet bulb (WB).For capacity information, see engineering manual capacity tables.3. All power/communication wiring minimum 4-conductor, stranded, shielded, and must comply with applicable local and national codes.4. Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to -17.8 C in cooling mode for applicable outdoor units.5. Airflow shown is in cooling mode.6. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the same in both cooling and heating mode. These values can increase due to ambient conditions during operation.7. Piping lengths are equivalent.8. Due to our commitment to continued innovation, some specifications may be changed without notification.15LG Air Conditioning Technologies

4-WAY HV4SpecificationUnitIndoor UnitOutdoor 00 12,4007,700 24,8009,700 26,70014,000 42,00017,100

number of LG training classes as well. Service Tools . TRAINING & RECOGNITION PTAC Award VRF Award WCCL Award USAC Award USHP Award ACCL Award LG's continuous excellence recognized at AHRI performance awards. 8 For jobs small to large, look for opportunities to use LG comfort systems everywhere! Explor

Related Documents:

surveyed 227 HVAC contractors who provided sales and services to residential customers and 803 residential customers who had purchased HVAC equipment in the previous five years. In addition, ODC conducted in-depthtelephone interviews with fourofthe eight major manufacturers of residential HVAC equipment, 20 HVAC distributors, and 20 residential

hvac piping abbreviations hvac piping symbols hvac symbols hvac electrical symbols sheet metal general notes hvac piping general notes project general notes all starters, disconnect switches, motor control centers, and variable frequency drives, for equipment provided under division 23, shall be furnished under

Alabama Power Company HVAC Training Center Approved Curriculum To Sit For State of Alabama HVAC Contractor’s Exam 1501 -Foundations for Troubleshooting HVAC Refrigerant Systems: 27 hours 4 Days. Systematic implementation of the HVAC system analysis procedure and validation of actual sealed system performance of fully operational HVAC equipment.

230548 vibration and seismic controls for hvac piping and equipment 230553 identification for hvac piping and equipment 230593 testing, adjusting, and balancing for hvac 230713 duct insulation 230716 hvac equipment insulation 230719 hvac piping insulation 230900 instrumentation and control for hvac 231113 facility fuel oil piping

High-rise commercial residential complex is a common form of the complex building. The form of the high-rise commercial residential complex building is formed a preliminary to the business services and residential function, based on some auxiliary building space. The high-rise commercial residential complex building has three dimensional spaces.

3.4 HVAC 84 3.4.1 HVAC Equipment 84 3.4.2 Cooling Equipment 85 3.4.3 Recent HVAC Cooling Purchases 96 3.4.4 Heating Equipment 99 3.4.5 Heating System Fuels 106 3.4.6 Heating System Efficiency 109 3.4.7 Recent HVAC Heating Purchases 113 3.4.8 HVAC

ACCA Approved Software Programs. Adtek Acculoads. AvenirMJ8 Editions. Carmelsoft HVAC. Elite HVAC. Cool Calc. Spec Pro. Wrightsoft. SUBMITTAL PROCEDURES. New Residential HVAC Process. New Permit Apply for a New Residential HVAC Permit Email Notification from DBS to Permit Holder of Manual S, J & D

products for over 50 years. From traditional Unit Heaters to Rooftop and Indoor Make-Up Air units, Sterling HVAC has the solution to fit every residential, commercial or industrial application. A division of Mestek, Inc. a family of over 36 specialty HVAC related manufacturers, Sterling HVAC proudly manufactures