CIRCUIT BREAKERS

REMOTE CONTROLLED CIRCUIT BREAKER (RCCB)Three Phase 115/200 VAC 400 Hz Three Phase OnlySingle Phase 28 VDC 115/200 VAC 400 HzQualifiedQualified to demanding performance parameters of MIL- PRF 83383 standard.PERFORMANCE DATARupture Levels3600 A (115 VAC or 28VDC for 1Pole and 115VAC for 3 Pole)Endurance(Resistive & Inductive(Motor)50,000 CyclesEndurance (Motor)5-50A: 50,000 cycles; 60-100A: 25,000 cyclesEndurance (Lamp)5-25A: 50,000 cycles; 35-50A: 25,000 cycles; 60-100A: no ratingDielectric Strength1500V, 60Hz, MIL-STD-202, method 301, 0.5 MA maxInsulation Resistance100 mega ohm min, MIL-STD-202, method 302Thermal Temperature Range-54 C to 71 C (-65 F to 160 F). MIL-STD-202, Method 107Vibration10G's to 2000 Hz. Exceeds MIL-STD-202, Method 204, Condition C, 10 microseconds max. chatterShock25G's. MIL-STD-202, Method 213, 10 microseconds max. chatterAltitude50,000 ft.EMI RequirementsMIL-STD-461, Requirements CS114 and RE102 over the frequency range of14 KHz to 400 MHz and RE102 limits for Aircraft and Space Systems.Weight and Cost SavingsEMI/RFI Susceptibilityand GenerationMIL-STD-461, Class 1DIn distributed-load applications,RCCBs are a more efficientpower distribution solution promoting cost and weight savingsthrough the elimination of longruns of heavy cables associatedwith the conventional relay flight deck circuit protectormethod. Control of the RCCBrequires only one #22 AWG control wire from the ICU on theflight deck to the RCCB.Moisture ResistanceMIL-STD-202, method 106Salt Spray ResistanceMIL-STD-202, method 101, Condition BSand and Dust ResistanceMIL-STD-202, method 110, Condition AFungus ResistanceMIL-HDBK-454, Guideline 4Explosion ProofMIL-STD-202, method 109Weight (Standard)5-25A: 318 grams (0.703 lbs.); 35-50A: 325 grams (0.719 lbs.); 60-100A: 332 grams (0.734 lbs.)Use as a Relay, CircuitBreaker, Or BothRCCBs combine the best attributes of a circuit breaker and arelay. Automatically protects thewires and the load device duringcircuit/load breakdown, butallows the flight deck control ofthe load during normal operation.Cockpit Space SavingsAn RCCB system removes thepresence of large circuit breakers from the cockpit while permitting remote On/Off operationfrom the flight deck. CombineLabinal Power Systems RCCBwith Indicator Control Unit (ICU)model #1500-053-05.Weight (w/ Auxiliary Contacts) 5-25A: 332 grams (0.734 lbs.); 35-50A: 339 grams (0.750 lbs.); 60-100A: 346 grams (0.766 lbs.)OVERLOAD CALIBRATION DATASpecificationTableMust Hold@ 25 CMINMAX115%@ 71 CMINMAX115%Must Trip138%@ -54 CMIN% for 1 Hour115%138%ORDERING INFORMATIONStandardLABINAL POWER SYSTEMS% Within 1 Hour150%Single Pole Single Throw (Double Break Contacts)34Test TimeParametersMAXThree Pole Single Throw(Double Break Contacts)w/ Auxiliary Contactsw/ Auxiliary ContactsAMPERERATING57.5MS P/NM83383/01-01LABINAL P/NSM600BA5N1**MS P/NM83383/02-01LABINAL P/NSM600BA5A1**MS P/NLABINAL 3383/04-10M83383/04-10All Ampere Ratings equal to Rated Contact Loads (Resistive, Inductive, Motor, and Lamp) except as noted.* No Lamp Load Rating** Contact Business UnitTF300-1ENote:Contact Business unit on Alternate Amperages, Trip Times, Control Configurations, Grounding, Auxiliary Switches, Mounting Systems, etc.

REMOTE CONTROLLED CIRCUIT BREAKER (RCCB)OVERLOAD CALIBRATION DATA - SINGLE POLEAMPERERATING200% Trip Times-54 C to 71 CMINMAX400% Trip Times-54 C to 71 CMINMAXOVERLOAD CALIBRATION DATA - THREE POLE1000% Trip Times-54 C to 71 51.7MAX1000% Trip Times-54 C to 71 C1.2545MIN400% Trip Times-54 C to 71 CSECONDS SECONDS SECONDS SECONDS2.8110.421.3SECONDS SECONDS SECONDS SECONDS13200% Trip Times-54 C to 71 CAMPERES SECONDS SECONDS101280AMPERES SECONDS .261.88014602.712.50.3210017633.5130.381.9TRIP CURVEContact business unit for trip curve.LABINAL POWER SYSTEMSTF300-1E35

REMOTE CONTROLLED CIRCUIT BREAKER (RCCB)1 POLE AND 3 POLEEngineering DataApplication NoteDistributed Load ConceptWith RCCBWithout RCCB1/2 AMPC8SWITCHSWITCH1/2 AMPBUSSC8100 AMPS100 AMPSC8RELAYBUSSRCCBLOADMS22073-1/2 ORMS26574-1/2LOADFLIGHT DECK100 AMPSFLIGHT DECKTypical Wiring DiagramIntegrated Wire Termination Module(MIL-STD-1549)LOAD3LINEA1A24 5A 5B 6 S3 S1 S2LOADLINELOADLINELOADAuxiliary Contacts When ApplicableTo Indicator/Control UnitCircuit BreakerInternal ConnectionType MS220731/2 OR MS26574Backup Control Power (when used)1/2115 V 400 HZ or 28 Vdc(Must be same AC Phase as the“Line” Power)Contacts and CoilCircuits OnlyS1S3A2S3 S1 S2To Indicator/Control UnitCircuit BreakerType MS220731/2 OR MS265741/2345A 5B6345A 5B6A1Internal CoilCurrentCut-OffSingle PoleLABINAL POWER SYSTEMSBackup ControlPower (whenused) 28 VdcContacts and CoilCircuits OnlyTF300-1EAuxiliary ContactsInternal ConnectionAuxiliary ContactsS2S2S3A2B2S2C2S2S2Intermittent DutyCoils Current CutOff ControlledElectronicallyNOTE: Units with date codesbeginning with third quarter 1993use electronically controlled coilcut-off without internal coil currentcut-off.NOTE: Terminals 5A and 5B internally grounded to the mounting leg (s). Integrated wiretermination (IWT) module accepts pin contacts P/N M39029/1-100 or -101. Use withinsertion/extraction tool M81969/14-02.363 4 5A 5BWiring for MultipleLine Protection3 4 5A 5B 6S2LINE Three Pole

REMOTE CONTROLLED CIRCUIT BREAKER (RCCB)1 POLE AND 3 POLEEngineering DataApproximate Dimensions - 1 PoleLOAD A2.688/17.48.172/4.37 DIA.2 MTG. HOLESLINE A1Typical Placement ofRating on Top PlaneR. g. FlangesMain ContactMate As ShownPosition IndicatorRed: Closed; Green: Open1.20030.48.3508.89.4210.67.071.778.0561.42.500 - .61012.70 - 15.24.1804.57NamePlateOptions Special application auxil-iary switches Unique grounding Power sources Other current ratings Control via systems otherthan I/CU Low level auxiliary con-tacts available Data Bus/Interface capability available Electronically held coil4.26108.203.4286.87.0842.13LINE A13.6993.731.5038.86LINE .562.52664.16.051.27.1303.3050LOAD C22.52664.162.2857.91LINE C1LOAD A2Main ContactPosition IndicatorRed: Closed;Green: OpenLOAD B23Pole4.26108.20Location ofNamePlate3.4387.123.25082.55Coil Operate Current/Set And Trip Time RCCBCircuits1 Pole3 PoleNominal SystemVoltage28 Vdc(18 Volts MIN.)115 Vac400 Hz (104 V.MIN.)28 Vdc(18 Volts MIN.)115 Vac400 Hz (104 V.MIN.)I/CU SetCurrent @NomVoltage(Mulliamp)Set CoilCurrent @NomVoltagePulse2MAX. Set Time*I/CU. Trip Current NominalNominalVoltage &RoomTemp.Most AdverseCondition - MIN.Voltage 71 C.Ambient71 C &NominalVoltage-54 C &NominalVoltageRoomTemp.NominalVoltage3.0 AMPMAX20 Millisec35 Millisec1.4 AMP1.9 AMP210 AMPMAX15 Millisec30 Millisec6.8 AMP**6.3 AMP**27.0 AMPMAX20 Millisec35 Millisec1.5 AMP2.0 AMP213.0 AMPMAX15 Millisec30 Millisec4.3 AMP**3.3 AMP*** MAX. I/CU. Line Impedance 7.5** Average Half-Wave Rectified DC Current71 C &NominalVoltage-54 C &NominalVoltageMAX.StandbyCurrentMilliamp1.6 AMP0.9 AMP***2.1 AMP108.6 AMP**6.1 AMP**7.0 AMP**101.7 AMP0.9 AMP***2.2 AMP104.5 AMP**4.0 AMP**3.1 AMP**10Current Decreases w/Time so that I2t***Absolute Min. Value from -54 to 71 CLABINAL POWER SYSTEMSTF300-1E37

MIL-STD-461, Class 1D Moisture Resistance MIL-STD-202, method 106 Salt Spray Resistance MIL-STD-202, method 101, Condition B Sand and Dust Resistance MIL-STD-202, method 110, Condition A Fungus Resistance MIL-HDBK-454, Guideline 4 Explosion Proof MIL-STD-202, method 109

Related Documents:

molded-case circuit breakers (MCCB), insulated-case circuit breakers (ICCB) and low voltage power circuit breakers LVPCB). Insulated-case circuit breakers are designed to meet the standards for molded-case circuit breakers. Low voltage power circuit breakers comply with the following standards: ANSI Std. C37.16—Preferred Ratings

Air Circuit Breakers Fixed Version for Power Distribution Emax 2 Icu 100kA - 200kA 4.14 . Air Circuit Breakers Accessories 4.16. 4 1SWC 010 000 C 0314 7 Circuit Breakers: 2 ABB SA LV Products Prices exclude VAT, subject to change without notice E & O.E. Terms & Conditions Apply Moulded Case Circuit Breakers

www.schneider-electric.us 1 . QO Miniature Circuit Breakers QO Plug-On Circuit Breakers Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801 QO Arc-Fault Circuit Breaker QO arc-fault circuit breakers provide protection for Series and Parallel Type Arcing as required by the NEC and local code adoption, and comply with UL1699. .

1-38 Siemens Industry, Inc. SPEEDFAX 2017 Product Catalog 1 LOAD CENTERS & CIRCUIT BREAKERS Circuit Breakers Special Application Breakers Product Category RESI n Built to order. Allow 2–3 weeks for delivery. Note: All circuit breakers on this page are 10K AIC a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting. Switching Neutral

Siemens LV 10 · 04/2020 Miniature Circuit Breakers Miniature Circuit Breakers All the information you need 3/2 Devices for all applications 3/4 System overview 3/5 Quick selection guide 3/6 Miniature circuit breakers 3/6 Device protection switches 3/10 Basic units 3/12 5SL3 miniature circuit breakers 3/12

Siemens Industry, Inc. SPEEDFAX 2017 Product Catalog 7-3 7 MOLDED CASE CIRCUIT BREAKERS Siemens / Speedfax Previous folio: 6-2 What’s new in molded case circuit breakers: The development of VL Circuit Breaker enclosures for the150A and 250A breakers demonstrates a significant

Section 1—General Information, provides an overview of electronic trip molded case circuit breakers. Section 2—MICROLOGIC Trip Systems Based On LE, LX, LXI, ME, MX, NE, NX, PE and PX Circuit Breakers, provides information about the electronic trip systems used in LE, LX, LXI, ME, MX, NE, NX, PE and PX circuit breakers only.

Molded Case Circuit Breakers M1-M4 Product Overview Features Series M Molded Case Circuit Breakers, 15 - 600A NOARK Electric offers a complete range of Molded Case Circuit Breakers in four frame sizes: 100AF, 225AF, 400AF and 600AF. Each frame offers a choice of interrupting ratings at voltages ranging from 240VAC to 690VAC and 250VDC to 600VDC.