ULTRA SERIES ULTRA98/120Installation & Operation InstructionsThe Santa Fe ULTRA98 and ULTRA120 areventilating dehumidifiers that integrate into theheating and cooling system to provide the ultimatein comfort, health and property protection through:Serial NumberInstall DateSold By Dehumidification Fresh Air Ventilation (Optional) Air Filtration* The Santa Fe Ultra98/120 was previously known as the Ultra Aire 98H/120H.800.533.7533 Santa-Fe-Products.comSanta-Fe-Products.com 800.533.7533Patent: thermastor.com/patentsSanta Fe ULTRA98/ULTRA120 Installation & OperationInstructionsTS-112604/21 Rev A 1

TABLE OF CONTENTSSafety Instructions.3Dehumidifier Set Up.4Attaching Duct Collars.5Electrical Requirements.6Drain Installation.7Ducting to HVAC Systems.8Recommended HVAC System Installation. 9Fresh Air Ventilation.10Determine Ventilation Requirements. 11Controls.12Air Filtration.14MERV Rating Chart. 15Service.16Warranty.19FOR REPAIR & TECH SUPPORT: 1-800-533-7533 (follow prompts)or CONTACT US AT: service@madisoniaq.comSanta Fe is committed to manufacturing quality products. To maintainour standards, product specifications may change without notice.4201 Lien Road, Madison, WI 53704(800) 533-7533Thermastor.com Santa-Fe-Products.com 2019 Therma-Stor LLC2Santa Fe ULTRA98/ULTRA120 Installation & Operation InstructionsSanta-Fe-Products.com 800.533.7533

SAFETY INSTRUCTIONSREAD THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS CAREFULLY BEFOREINSTALLING AND OPERATING THIS DEVICE. PROPER ADHERENCE TO THESE INSTRUCTIONS ISESSENTIAL TO OBTAIN MAXIMUM BENEFIT FROM YOUR SANTA FE VENTILATING DEHUMIDIFIER.WARNING!THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT IN SERIOUS INJURY OR DEATH.CAUTION!THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT IN INJURY OR MATERIAL PROPERTY DAMAGE.RegistrationsThis Santa Fe dehumidifier conforms to unified standard UL 60335-2-40 and CSA standardC22.2.60335-2-40.WARNING!120 VOLTS MAY CAUSE SERIOUS INJURY FROM ELECTRIC SHOCK.DISCONNECT ELECTRICAL POWER BEFORE STARTING INSTALLATION ORSERVICING, AND LEAVE POWER DISCONNECTED UNTIL INSTALLATION ORSERVICE IS COMPLETED.CAUTION!READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.ALWAYS USE CAUTION AND WEAR CUT RESISTANT GLOVES WHEN HANDLING SHEET METAL.IMPROPER INSTALLATION MAY CAUSE PROPERTY DAMAGE OR INJURY.INSTALLATION, SERVICE, AND MAINTENANCE MUST BE PERFORMED BY A QUALIFIED SERVICETECHNICIAN.DEHUMIDIFIER IS HEAVY. HANDLE WITH CARE AND FOLLOW INSTALLATION INSTRUCTIONS.NEVER OPERATE A UNIT WITH A DAMAGED POWER CORD. IF THE POWER CORD ISDAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS SERVICE AGENT, OR A SIMILARLYQUALIFIED PERSON IN ORDER TO AVOID A HAZARD.THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCEDPHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCEOR KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTIONCONCERNING THE USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIRSAFETY. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THEAPPLIANCE.800.533.7533 Santa-Fe-Products.comSanta Fe ULTRA98/ULTRA120 Installation & Operation Instructions3

DEHUMIDIFIER SET UPImportant Precautions The device is designed to be installed indoors in a space that is protected from rain and flooding. Install the unit with enough space to access one of the side panels for maintenance and service. Avoid directing the discharge air at people. The dehumidifier should be used in the upright position. If used near a water source, be certain there is no chance the unit could fall into the water or get splashed andthat it is plugged into a dedicated circuit and Ground Fault Circuit Interrupter (GFCI) protected outlet. DO NOT use the dehumidifier as a bench or table. DO NOT place the dehumidifier directly on structural building members without vibration absorbers orunwanted noise may result. Place the Santa Fe Dehumidifier on supports to raise the base of the unit. A drain pan with a float switch MUST be placed under the dehumidifier if installed above a living area or abovean area where water leakage could cause damage.Location Considerations6" Minimum ClearanceFor Proper Airflow Allow sufficient clearance to handle the unit’s overalldimensions as well as the necessary return andsupply ductwork to the unit.A Allow sufficient clearance for filter removal and toprevent airflow obstruction. Electrical service access will require the removal ofa side panel. Allow sufficient clearance on a side ofthe unit. Locate the dehumidifier in an area where the cord’slength (9') easily reaches a 115 VAC electrical outletwith a minimum of a 15 Amp circuit capacity.BMinimumClearance15"For Filter(Either Side) Locate the dehumidifier in an area where field wiringthe control (low voltage) to the unit will be possible.Top ViewElectrical Service Access(Either Side)FilterCDrain Port9' Power CordA 6" Fresh Air Intake (Optional)B 10" Return Air DuctC 10" Supply Air Duct It is recommended that a backdraft damper beused in the discharge duct of the Santa FeDehumidifier, especially when connecting to the supply ducting system. The backdraft damper prevents supplyair from counter flowing through the Santa Fe Dehumidifier when it is not operating. The dehumidifier’slocation should be chosen to allow installation of this accessory if necessary. The Santa Fe Dehumidifier may be suspended from structural members with steel hanger straps or a suitablealternative, ensuring the assembly supports the dehumidifier’s base in its entirety. DO NOT hang the Santa FeDehumidifier from its cabinet. Allow for proper routing and drainage of needed drain pipes.CAUTION!REMOVE COMPRESSOR SHIPPING TIE FROM THE UNIT. FAILURE TO REMOVE SHIPPING TIEWILL CAUSE EXCESS VIBRATION TO BE TRANSMITTED TO THE FRAME.Removal of Compressor Shipping SupportThe Santa Fe Dehumidifier uses a compressor to power therefrigeration system. To protect the compressor and refrigerationsystem during shipping, a plastic tie wrap secures it to the unit’sframe. Remove the tie wrap by cutting the tie wrap and pullingfrom the unit as shown. After removing tie wrap, insert plastic plugsprovided into the holes.4Santa Fe ULTRA98/ULTRA120 Installation & Operation InstructionsSanta-Fe-Products.com 800.533.7533

ATTACHING DUCT COLLARSFresh Air Ventilation DuctFresh air ventilation is optional. A 6" diameter duct is attached to the unit. The 6" duct should be capped iffresh air is not desired. If setting up the unit to provide fresh air ventilation, see page 10.Return Air InletA 10" diameter duct collar is attached to the unit.Supply Air Outlet he back panel of the dehumidifier can be rotated to allow for horizontal flow through or vertical flow throughTof the supply air. Horizontal Flow ThroughThe unit ships configured for a horizontal flow through. A 10" diameter duct collar is attached to the unit. Vertical Flow ThroughRemove the exhaust panel using a T25 torx bit. Rotate the panel so the exhaust collar is located on the topof the unit. Align screw holes and snap the panel onto the base. Secure the exhaust panel to the base byreplacing the six wThroughThrough(Top(TopDischarge)Discharge)CCAAAir AirFlow FlowBBCCAAAir AirFlow FlowBBA 6" AFresh6" FreshAir InletAir Inlet(Optional)(Optional)10" ReturnAir InletAir InletB 10"BReturnC 10"CSupply10" SupplyAir OutletAir OutletFrontFrontView ViewARear RearView ViewABCB800.533.7533 Santa-Fe-Products.comCA 6" AFresh6" FreshAir InletAir Inlet(Optional)(Optional)10" ReturnAir InletAir InletB 10"BReturnC 10"CSupply10" SupplyAir OutletAir OutletFrontFrontView ViewARear RearView ViewTop ViewTop ViewACBCBSanta Fe ULTRA98/ULTRA120 Installation & Operation Instructions5

ELECTRICAL REQUIREMENTSThe Santa Fe Dehumidifier plugs into a common grounded 115 VAC outlet. Locate the dehumidifier in anarea where the cord’s length (9') easily reaches a 115 VAC electrical outlet with a minimum of 15 Amp circuitcapacity. If used in an area that may become wet, a GFCI protected circuit is recommended. Consult localelectrical codes for further information.Santa Fe offers a variety of control devices for use with the Santa Fe Dehumidifier. The control is to be locatedremotely from the dehumidifier and placed in the space to be conditioned. A low voltage (24 Volt) control MUST beused with the Santa Fe Dehumidifier and MUST be connected with low voltage (18-22 gauge) thermostat wire.WARNING!THE REMOTE CONTROLS OF THE SANTA FE DEHUMIDIFIER ARE POWERED BY A LOW VOLTAGECIRCUIT (24 VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE CIRCUIT.CAUTION!DO NOT ALLOW THE 24V TERMINAL TO CONTACT THE COM/DMPR TERMINALS ON THESANTA FE DEHUMIDIFIER OR DAMAGE TO THE TRANSFORMER WILL RESULT.CAUTION!SOME OF THE SCREW TERMINALS ON THE SANTA FE DEHUMIDIFIER MAY NOT BE USED WITHCERTAIN CONTROLS AND SHOULD BE LEFT UNCONNECTED.Electrical Precautions Do not install the control where it may not accurately sense the relative humidity such as near HVACsupply registers, near exterior doors, on an outside wall, near a window, or near a water source. The screw terminals on the Santa Fe Dehumidifier and the control are labeled to prevent confusion. Be sure to consult the electrical schematic in the CONTROLS Section (page 12) of this manual or insidethe access panel of the Santa Fe Dehumidifier before making control connections.Santa Fe ULTRA98H Wiring Diagram6Santa Fe ULTRA120H Wiring DiagramSanta Fe ULTRA98/ULTRA120 Installation & Operation InstructionsSanta-Fe-Products.com 800.533.7533

DRAIN INSTALLATIONDrain PortThe Santa Fe Dehumidifier generates condensate.Place a secondary drain pan with a float switch under the dehumidifier if it is suspended above a finishedSecondary Drain Panarea or above an area where water leakage could cause damage.Drain TrapA drain trap is required for the dehumidifier to drain properly. Install a 3/4" threaded male NPT adapter tothe drain pan. Install a drain pipe assembly utilizing 3/4" PVC pipe to transport the condensate to a drain.Pitch of drain should be 1" per 10'.An optional condensate pump kit is available for use with the Santa Fe Dehumidifier and may be installedif lift is required to dispose of condensate. Condensate is automatically pumped to a remote location whenthe water level in the pump’s reservoir rises to close the float switch.The pump also contains a safety float switch. The white leads from this switch extend from beneath thepump cover. This switch should be installed in series with the field wire that connects to the common leadfrom the Santa Fe Dehumidifier to the control panel. If the pump fails, this switch opens the common controlcircuit and stops water production before the reservoir overflows. Contact a qualified electrician to install thesafety float switch to the Santa Fe Dehumidifier.Note: An optional condensate pump kit can be purchased through your dealer or online.Drain InstallationDrainPortSide ViewDrainTrapDrain PortDrain Trap800.533.7533 Santa-Fe-Products.comSecondaryDrain PanSecondary Drain PanDrainPortSanta Fe ULTRA98/ULTRA120 Installation & Operation Instructions7

DUCTING TO HVAC SYSTEMSThe recommended installation creates a separate return for the Santa Fe Dehumidifier in a central areaof the structure. Duct the supply of the unit to the air supply of the existing HVAC system. Connect aninsulated duct from outside to the 6" collar of the Santa Fe Dehumidifier to provide fresh make-up air.CAUTION!DO NOT CONNECT WITH A STATIC PRESSURE GREATER THAN OR EQUAL TO 0.5 WG.CONTACT TECHNICAL SUPPORT AT (800) 533-7533 FOR ADDITIONAL DETAILS.Ducting Considerations: All flexible ducting connected to the Santa Fe Dehumidifier should be UL listed. A short piece of flexible ducting on all Santa Fe Dehumidifier duct connections is recommended to reducenoise and vibration transmitted to rigid ductwork in the structure. Use a minimum 10" diameter round or equivalent rectangular duct for total duct lengths of up to 25'. Usea minimum 12" diameter round or equivalent rectangular duct for longer lengths. Grills or diffusers on the duct ends must not excessively restrict airflow. Effective dehumidification may require that ducting be branched to isolated, stagnant air flow areas. Whenducting to two or three areas, use 8" or larger diameter branch ducting. When ducting to four or moreareas, use 6" or larger diameter branch ducting. Provisions must be made to provide airflow from supplylocations to the central return location. Proper air distribution is important to ensure even humidity controland heat distribution throughout the structure. DO NOT locate the return in a bathroom or a kitchen.8Santa Fe ULTRA98/ULTRA120 Installation & Operation InstructionsSanta-Fe-Products.com 800.533.7533

DUCTING TO HVAC SYSTEMSRecommended HVAC System InstallationThe recommended installation draws air from a dedicated indoor air return and ducts the supply of thedehumidifier to the air supply of the existing HVAC system. Utilize the optional fresh air ventilation duct toprovide outside air. Install a dedicated 10" air return for the Santa Fe Dehumidifier from a central area of the structure. Install an insulated duct from outside to the 6" collar of the Santa Fe Dehumidifier to provide fresh airventilation (optional). Duct the supply of the Santa Fe Dehumidifier to the supply of the existing HVAC system with a backdraftdamper. If the existing system has multiple returns, instead of installing a dedicated return to the Santa FeDehumidifier, it is possible to select one to disconnect from the existing HVAC system and use it for thededicated Santa Fe Dehumidifier return. Select a return from a central location in the house that is alwaysopen to the rest of the structure. DO NOT use a return from a room where doors are kept closed. DO NOT locate return in a bathroom or kitchen. Control should be located remotely from the dehumidifier and placed in a central location.Dedicated Ultra-Aire 90 Return to A/C SupplyPlease visit our website at www.Santa-Fe-Products.com/install-options/ for more installation options.Dedicated Santa Fe Return to HVAC SupplyFresh Air Intake(Optional)MotorizedDamperAir HandlerHVAC ReturnHVAC SupplyBackdraftDamperIndoorAir Return800.533.7533 Santa-Fe-Products.comSanta FeSupplySanta Fe ULTRA98/ULTRA120 Installation & Operation Instructions9

FRESH AIR VENTILATIONFresh air ventilation is optional.Fresh air may be brought into the structure by connecting an insulated duct from outside the structure tothe 6" inlet of the Santa Fe Dehumidifier. A ventilation control is needed to program the time and frequencythat the unit introduces outside air. The time and frequency of ventilation should be based on the size andoccupancy of the residence. The fresh air ventilation duct should be connected to the 6" round collar on the front of the Santa FeDehumidifier. An insulated 6" diameter duct can provide up to 75 CFM of outside air. If a motorized damper is not being used, fresh air is controlled by the manual damper in the 6” collar of theSanta Fe dehumidifier. Performance of the Santa Fe Dehumidifier can be impacted by inside and outside air conditions. When a 6" motorized damper is used, a digital control is required. It may be necessary to use 8" duct work if additional fresh air is required. In cold climates or at times when the dew point is low, ventilation can be used to dehumidify the structure,making the Santa Fe Dehumidifier capable of year-round drying.Fresh Air Ventilation With Dehumidifier Off and Fan Only OperationOutside air mixes with the dehumidifier’s return air before being supplied to the home. Outsidetemperature, inside temperature and relative humidity will impact the combined outlet air conditions.Hot ClimateA 6" Fresh Air Inlet(Optional)B 10" Return Air InletC 10" Supply Air OutletAOutdoor Air90 F, 65%RHBIndoor Air70 F, 50%RHMixed Air75 F65%RHCOutlet Air75 F, 65%RHCold ClimateA 6" Fresh Air Inlet(Optional)B 10" Return Air InletC 10" Supply Air OutletAOutdoor Air30 F, 65%RHBIndoor Air70 F, 50%RHMixed Air59 F51%RHCOutlet Air59 F, 51%RHNote: Temperature and relative humidity may vary depending on duct distribution scheme.10Santa Fe ULTRA98/ULTRA120 Installation & Operation InstructionsSanta-Fe-Products.com 800.533.7533

FRESH AIR VENTILATIONDetermine Ventilation RequirementsThe MINIMUM ventilation requirement is calculated using ASHRAE 62.2-2016. Use one or both of the options belowto determine your ventilation requirement. Follow all local and national building and safety codes.Option 1: Calculating Airflow Requirement Using ASHRAE 62.2-2016 Airflow EquationASHRAE Airflow in CFM [House Area in Sq.Ft. x 0.03] [(Number of Bedrooms 1) x 7.5]NOTE: Use ‘Number of Bedrooms 1’ or ‘Number of Occupants’, whichever is larger.Example 1: Number of Bedrooms 11800 square foot house with 3 bedrooms, 4 occupants [1800 X 0.03] [(3 1) X 7.5] 84 CFMExample 2: Number of Occupants1800 square foot house with 3 bedrooms, 5 occupants [1800 X 0.03] [5 X 7.5] 91.5 CFMRecord the required CFMOption 2: Calculating Airflow Requirement Using Table 4.1 from ASHRAE 62.2-2016Ventilation Air Requirements, CFMFloor Area(ft2)Number of Bedrooms12345 5003038455360501 - 100045536068751001 - 150060687583901501 - 2000758390981052001 - 250090981051131202501 - 30001051131201281353001 - 3500120128135143150Table 4.1 from ASHRAE 62.2-2016Record the required CFM800.533.7533 Santa-Fe-Products.comSanta Fe ULTRA98/ULTRA120 Installation & Operation Instructions11

CONTROLSA control must be used with the Santa Fe Dehumidifier. Santa Fe offers the DEH 3000 proprietary control.The DEH 3000 allows homeowners to monitor and control relative humidity and proper ventilation levels intheir home. This control is also available with a remote sensing option.Note: The DEH 3000 is sold seperately and can be purchased through your local dealer or online. Otherthermostats are compatible with the Santa Fe Dehumidifier.Wiring ControlsCAUTION! O NOT ALLOW THE 24V TERMINAL FROM THE SANTA FE DEHUMIDIFIER TO CONTACTDTHE COM TERMINAL ON THE SANTA FE DEHUMIDIFIER OR DAMAGE TO THETRANSFORMERS WILL RESULT.Circuit BreakerTo prevent damage to the 24 volt controltransformer, the Santa Fe Dehumidifier comeswith a resettable circuit breaker. Check wiringfor any electrical short and repair beforeresetting breaker. Resetting the circuit breakerwithout correcting the electrical short mayresult in transformer damage. Be sure tocheck the electrical schematic in this manualor inside the access panel of the Santa FeDehumidifier before making any controlconnections. The reset button for the circuitbreaker can be found on the back of the unit.Rear ViewSanta Fe ULTRA98HSanta Fe ULTRA120HCircuit Breaker Reset Button12Santa Fe ULTRA98/ULTRA120 Installation & Operation InstructionsSanta-Fe-Products.com 800.533.7533

CONTROLSControl ConnectionsThe control and the Santa Fe Dehumidifier are labeled to prevent confusion. Depending on the control,some of the screw terminals on the Santa Fe Dehumidifier may not be used. Be sure to consult theelectrical schematic in this manual or inside the access panel of the Santa Fe Dehumidifier beforemaking control connections.A low voltage control must be used with the Santa Fe Dehumidifier.Santa Fe ULTRA98H Terminal Block Control Operation:COM24VAC Power Transformer Neutral SideFANFan Control24VTransformer High SideDEHUDehumidification (Fan and Compressor) ControlDMPR24VAC Power Transforme Neutral Side*Spare Terminal (Open)Santa Fe ULTRA120H Terminal Block Control Operation:COM24VAC Power Transformer Neutral SideFANFan Control24VTransformer High SideDEHUDehumidification (Fan and Compressor) ControlFLOAT External Low Voltage Float Switch or Water Sensor(Use Normally Closed Switch)FLOAT External Low Voltage Float Switch or Water Sensor(Use Normally Closed Switch)Between the COM lead and the 24V TERMINAL is a 40VA transformer. This low voltage power sourcepowers the relay coils which control the fan and compressors. This 24VAC transformer can also beused to power HVAC accessories external to the dehumidifier.Compressor ON / Fan ONMake contact between 24V and DEHU terminalsCompressor OFF / Fan ONMake contact between 24V and FAN terminalsPower HVAC AccessoryConnect the accessory to the DMPR (OR COM) and 24V terminalsNOTE: 18 gauge wire needed between the Santa Fe Dehumidifier and the external control.800.533.7533 Santa-Fe-Products.comSanta Fe ULTRA98/ULTRA120 Installation & Operation Instructions13

AIR FILTRATIONThe Santa Fe Dehumidifier is equipped with a MERV-13 (Dimensions: 1.75” x 14.00” x 17.50”) filter. The filtershould be checked and replaced every three to six months. Operating the unit with a dirty filter will reducedehumidifier capacity and efficiency.DO NOT operate the unit without the recommended filter. Filter non-compliance voids the product warranty.CAUTION!MAKE SURE UNIT IS OFF BEFORE CHANGING THE FILTER.Changing the FilterFor greatest filtration and efficiency of the Santa Fe Dehumidifier, it is recommended the air filter bereplaced every three to six months with a MERV-13 filter.MagneticMagneticStrip StripnaleshFreshakeSupplySupplyStep 1: Pull back slide latch to swing filter door open.Slide LatchFresh Air Intake(Optional)neturnTop ViewTop ViewReturnSide ViewSide ViewSide ViewFilter DoorStep 2: Remove the filter by gently pulling it straight out of the unit. Insert new filter by gently pushing itstraight into the unit. Make sure the AIR FLOW arrow on the filter is pointing into the unit.SupplySupplyViewTop ViewFresh AirIntake(Optional)To Remove,pull out FreshAir urnReturnSide ViewFront ViewViewTop ViewTo Replace,push in straight.FilterDoorFront ViewFilterStep 3: Insert filter door into tabsand swing door closed to lockTabsthe latch into place.Side View14Santa Fe ULTRA98/ULTRA120 Installation & Operation InstructionsSide ViewSanta-Fe-Products.com 800.533.7533

AIR FILTRATIONMERV Rating ChartStandard 52.5 MinimumEfficiency ReportingValueDust SpotEfficiencyArrestanceTypical ControlledContaminantn/an/a 0.30 pm Particle SizeCleanroomsn/an/aCarbon DustPharmaceutical Man.201918171615 95%n/a1490-95% 98%Most Tobacco Smoke131289-90% 98%Proplet Nuceli (Sneeze)1160-65%n/an/an/a70-75%n/an/an/a 95% 95%Virus (unattached)All Combustion Smoke.30-1.0 pm Particle SizeAll Bacteria1.0-3.0 pm Particle SizeLegionellaTypical Applications andLimitationsRadioactive MaterialsCarcinogenetic MaterialsLead DustBag Filter - NonsupportedMilled Flour940-45% 90%Welding FumesAuto EmissionsHospital Laboratories830-35% 90%3.0-10.0 pm Particle SizeCommercial Buildings725-30% 90%6 20%85-90%5 20%80-85%4 20%321Better ResidentialDusting AidsIndustrial WorkplaceCement Dust 99.97% eff. On .30 pm Particlesmicrofine fiberglass orsynthetic media, 12-36 in. deep,6-12 pockets.Smoking LoungesBox Filter - Rigid Style CartridgeFilters 6 to 12" deep may useSuperior Commercial Buildings lofted or paper media. 95%Fabric ProtectorpSuperior ResidentialHospital Inpatient Care50-55%Hair SprayParticulatesBag Filter - Nonsupported10Mold SporesParticlesGeneral SurgeryBetter Commercial BuildingsHumidifier DustTypical Air Filter/Cleaner Type 99.999% eff. On .10-.20 pmParticlespmicrofine fiberglass orsynthetic media, 12-36 in. deep,6-12 pockets.Box Filter - Rigid Style CartridgeFilters 6 to 12" deep may uselofted or paper media.Pleated Filters - Disposable,extended surface area, thick withcotton-polyester blend media,cardboard frame.Cartridge Filters - Graded densityviscous coated cube or pocketfilters, synthetic media.Throwaway - Disposablesynthetic panel filter.Pudding MixPaint Booth Inlet75-80% 10.0 pm Particle SizeMinimal FiltrationThrowaway - Disposablefiberglass or synthetic panel filter. 20%70-75%Dust MitesResidentialWashable - Aluminum Mesh. 20%65-70%Window A/C UnitsElectrostatic - Self chargingwoven panel filter. 20% 65%PollenSanding DustSpray Paint DustTextile FibersCarpet FibersTable Data Source: United States Environmental Protection Agency800.533.7533 Santa-Fe-Products.comSanta Fe ULTRA98/ULTRA120 Installation & Operation Instructions15

SERVICETroubleshootingCAUTION!TROUBLESHOOTING SHOULD BE PERFORMED BY A QUALIFIED HVAC TECHNICIAN.SymptomPossible ReasonNeither fan norcompressorrunning.Dehumidificationis being called for.1. D ehumidifier unplugged or no power to outlet.6. O pen circuit betweenFLOAT terminals.1. D efective compressorrun capacitor.2. Loose connection incompressor circuit.3. Defective compressoroverload.4. Defective compressor.5. Defrost thermostat open.1. Low ambienttemperature and/orhumidity causing unitto cycle throughdefrost mode.2. Defective compressoroverload.3. Defective compressor.4. Defrost thermostatdefective.5. Dirty air filter(s) or airflow restricted.6. Defective fan or relay.16ELECTRICAL SHOCK HAZARD:ELECTRICAL POWER MUST BE PRESENTTO PERFORM SOME TESTS. THESE TESTSSHOULD BE PERFORMED BY A QUALIFIEDSERVICE PERSON.3. Loose connection ininternal or control wiring.5. D efective controltransformer.Compressorcycles on and off.Dehumidification isbeing called for.WARNING!2. H umidity control settoo high.4. D efective compressorrelay.Compressor isnot running.Dehumidificationis being called for.Fan is running.Troubleshooting ProcedureTroubleshooting Procedure for ControlRelated IssuesThis method of diagnosis will test the 3 maincomponents of the control circuit individually toindicate any potential problems. This is to be usedwhen the control will not activate the main unit.1. Detach field control wiring connections fromthe terminals on the main unit.2. Connect the 24V and FAN terminalstogether; only the fan should run. Disconnectthe terminals.3. Connect the 24V and DEHU terminalstogether; fan and compressor should run.Disconnect the terminals.4. If this test works, the main unit is workingcorrectly from a control standpoint.5. Reconnect field control wiring to the terminalson the main unit.6. Remove the control panel cover and detachthe field wiring from the control connections.7. Connect the 24V and FAN terminals together;only the fan should run. Disconnect the terminals.8. Connect the 24V and DEHU terminals together;fan and compressor should run. Disconnect theterminals.9. If this test works, then the field control wiringis ok.10. If the problem persists, then the control ismost likely faulty.Santa Fe ULTRA98/ULTRA120 Installation & Operation InstructionsSanta-Fe-Products.com 800.533.7533

SERVICETroubleshooting (Continued)SymptomPossible ReasonFan is not running.Dehumidificationor fan is beingcalled for.1. Loose connection infan circuit.Troubleshooting ProcedureWARNING!ELECTRICAL SHOCK HAZARD:ELECTRICAL POWER MUST BE PRESENTTO PERFORM SOME TESTS. THESE TESTSSHOULD BE PERFORMED BY A QUALIFIEDSERVICE PERSON.2. Obstruction preventsfan impeller rotation.3. Defective fan.4. Defective fan relay.Low dehumidification 1. Defrost thermostat loosecapacity (evaporatoror defective.is frosted2. Low refrigerant charge.continuously).3. Dirty air filter(s) or air flowDehumidification isrestricted.being called for.4. Excessively restrictiveducting connected to unit.No ventilation.Ventilation is beingcalled for.1. L oose connection inventilation control circuit.2. L oose connection indamper power circuit.1. A ir temperature and/orhumidity have dropped.3. U nit has entered defrostcycle.4. D irty air filter(s) or air flowis restricted.6. Low refrigerant charge.7. A ir leak such as loosecover or ducting leaks.8. Defective compressor.9. Restrictive ducting.800.533.7533 Santa-Fe-Products.com1. Set the humidity controller all the way to themost humid setting or off position – Did theunit shut off?2. If yes, turn the fan setting to the ON position –does the fan start?4. Listen for a distinct buzzing/humming soundof a compressor starting up – do you hear thisnoise?2. H umidity meter and orthermometer used areout of calibration.5. D efective defrostthermostat.This method of diagnosis is used to functioncheck the internal components in the dehumidifier. This is to be used when a performance issueis suspected.3. If fan starts, leave in the fan ON position andset the humidity all the way to driest setting.May have to wait 5 minutes for the compressorto start.3. D efective fresh airdamper.Dehumidifierremoves somewater, but not asmuch as expected.Troubleshooting Procedure for PerformanceRelated Issues5. If compressor is running and continues to run,after about 15 minutes you should feel a slightincrease in air

6" Fresh Air Inlet (Optional) 10" Return Air Inlet 10" Supply Air Outlet A B C A B C Flow Front View Rear View A B Fresh Air Ventilation Duct Fresh air ventilation is optional. A 6" diameter duct is attached to the unit. The 6" duct should be capped if fresh air is not desired. If setting up the unit to pro

Related Documents:

4 santa: ungodly santa & elves: happy all the time santa: when they sing until they’re bluish, santa wishes he were jewish, cause they’re santa & elves: happy all the time santa: i swear they're santa & elves: happy all the time santa: bizarrely happy all the time (elves ad lib: "hi santa" we love you santa" etc.) popsy:

SANTA ANA CITY COUNCIL Vicente Sarmiento Mayor vsarmiento@santa-ana.org David Penaloza Mayor Pro Tem, Ward 2 dpenaloza@santa-ana.org Thai Viet Phan Ward 1 tphan@santa-ana.org Jessie Lopez Ward 3 jessielopez@santa-ana.org Phil Bacerra Ward 4 pbacerra@santa-ana.org Johnathan Ryan Hernandez Ward 5 jryanhernandez@santa-ana.org Nelida Mendoza

SANTA MARIA OUTER SANTA CRUZ S A LI N A S C U Y A M A OFFSHORE SANTA MARIA SANTA LUCIA SANTA BARBARA-VENTURA LOS ANGELES . SANTA ROSA 20 KM Figure 1C. Oil and gas fields in the assessment province and adjacent areas to

301 Santa Monica Pier Bubba Gump Shrimp Co. 401 Santa Monica Pier Mariasol Restaurant 200-B Santa Monica Pier Soda Jerks 330 Santa Monica Pier Pier Burger (replacing Surfview Café September 2011) 350 Santa Monica Pier Playland Arcade 250 Santa Monica Pier Pizza Al Mare (in Plan Check expected to open by Summer 2012)

Samy’s Camera and Digital Santa Barbara Adventure Company Santa Barbara Four Seasons Biltmore Santa Barbara Museum of Natural History Santa Barbara Sailing Center Santa Barbara Zoo SBCC Theatre Michael J. Singer, IntuitiveSurf Happens Suzanne’s Restaurant Terra Sol The Cottage - Kristine

Installation, Operation, and Service Instructions Installation, Operation and Maintenance Instructions for your Cryo-Torr vacuum pump provides easily accessible information. All personnel with installation, operation, and servicing responsibilities should become familiar with the contents of these instructions to ensure safe, reliable

II. INSTALLATION/OPERATION INSTRUCTIONS Installation Instructions 5 Electrical Installation Instructions 6 Operation Instructions 7 Chemical Dispensing Equipment 9 Detergent Control 10 III. PREVENTATIVE MAINTENANCE 12 IV. TROUBLESHOOTING SECTION Common Problems 15 V. PARTS SECTION Chemical Feeder Pump Assembly 17 Solenoid Valve Repair Parts 18

Santa Fe Opera Guild Board member, Benjamin N. Saiz. His roots in Santa Fe’s arts and civic communities run deep and include over five decades of service to the Santa Fe Opera. Ben is a true son of Santa Fe, a direct descendent of one of the city’s oldest families. Melinda Ortiz, h