01991 D2 Phaser MON14.qxp:210x279

2y ago
4 Views
3 Downloads
1.69 MB
7 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Matteo Vollmer
Transcription

Bruker AXSD2 PHASERDiffraction Solutionsthink forwardXRD

Compact all-in-onedesktop designInnovative high-endgoniometer designIntegrated PC / monitorDIFFRAC.SUITE softwareLeading detector technologyThe whole worldof X-ray diffractionon a desktop –D2 PHASERStatus display LEDsTransport handles1-dimensional LYNXEYE detectorInternal chillerUSB and Ethernet connectorsIntegrated drawer forkeyboard and mouseD2 PHASER with openedfront coverX-ray on status LEDsWhat do you obtain when patentedtechnologies, award-winning software,a fully functional PC with monitor andstate-of-the-art detectors meet up withleadership in innovative X-ray diffraction?Perfect solutions for powder diffraction.And if it all fits onto a desktop,it is called D2 PHASER!What enables this evolutionary leap to take place andhow can the amazing performance of this space savingsensation actually be explained?First of all, you develop an ultra compact goniometer,file a patent, complete the system with all the othercomponents for autonomous operation and package thewhole configuration together with a fully functional PC,monitor, keyboard and mouse, into a compact housing.Second, you use the unique DIFFRAC.SUITE softwarefor controlling the instrument and analyzing the data.Since its introduction the DIFFRAC software has developed into a high performance tool for the characterizationof crystalline phases in research and industry.Third, you use only the best components, forexample the LYNXEYE detector. This state-of-the-art andextremely efficient 1-dimensional detector simultaneously captures a large angular range and radically reducesthe measurement time: hours turn into minutes.Combining all of these incredible innovations creates adesktop X-ray diffractometer which has the analyticalperformance and functions of a large instrument, butwhich is easy to transport and opens up the whole worldof powder diffraction without a lot of infrastructure.D2 PHASER – all-in-one desktop design2D2 PHASER – never before was desktopX-ray diffraction better, smaller and morepowerful!3

Holderswith variouscavitiesHolder forautomatedsamplepreparationHolder forclaysLow backgroundholders forsmall sampleamountsAirtightholder forenvironmentsensitivesamplesHolder forfilter samplesD2 PHASER – thedesktop giant!Wishes come true – comprehensive,unique and non-destructive characterizationof crystalline samples by means of X-raydiffraction (XRD) with the D2 PHASER.Our D2 PHASER opens the door to modern XRD for you.This means qualitative and quantitative phase analysis,polymorphism investigation, the determination ofcrystallinity, all the way through to structure investigation– all of it fast, simple, efficient and with high quality.It is not just its analytical performance that makes theD2 PHASER so revolutionary, but also its flexibility inhandling very diverse samples. Different materialproperties require different sample preparations.Therefore, besides a series of standard sample holdersmade from PMMA or steel, the D2 PHASER also offersholders for small sample amounts, low-absorbing andweakly diffracting samples, for filters, for environmentsensitive samples and for examining materials that tendto show a preferred orientation.Cement &Raw MaterialsMinerals& MiningGeology &ExplorationCeramicsChemistry& CatalystsResearch& EducationPharmaceuticalsEnvironmentLYNXEYE fast-lane editionWhat makes the D2 PHASER absolutely unique is theintegration of the world's leading 1-dimensional detectorfor X-ray powder diffraction: Our LYNXEYE.With a performance enhancement in terms of intensityby a factor of more than 150, the D2 PHASER is actuallyplaying in the top class. Additionally the LYNXEYE allowssuppression of sample fluorescence providing an excellent peak-to-background ratio even for strongly fluorescent samples, eliminating any need for secondarymonochromators.D2 PHASER – slide-up front cover for sample loading, monitor remains activeD2 PHASER – X-ray diffraction in anew dimension!Phase identification and quantificationDegree of crystallinity determinationPhase properties (cell parameters,crystallite size, and lattice strain)Crystal structure analysisWide variety of different sample holders ofindustrial standard dimension (Ø 51.5 mm)45

Plug’nAnalyze On-SiteReadyHand CarryWeightNoWaterSupplyNoHighPowerNoPC &PeripheralsAll-in one is everything you need –D2 PHASERCan XRD – the best method for phasecharacterization – really produce highquality data without the need for acorresponding infrastructure?Yes! With our D2 PHASER a new era begins.All that is required is a simple domestic wall socket andyou can start producing outstanding analytical results:Plug ‘n Analyze. Since it is a desktop system it requiresonly a minimum amount of space and is in no wayinferior to a large system in terms of its analyticalperformance. Resolution, angular accuracy and datastatistics set new standards in this class of analyticalinstruments; data quality which you can rely on and withwhich even complex questions can be answered.Our D2 PHASER is a transportable all-in-one instrumentthat requires no additional cooling water or PC peripherals.This means that there is nothing to prevent it from beingused outdoors: simply switch-on a power generator, plugin the connector and start measuring!DIFFRAC.EVAQualitative phase identification- ICDD PDF2 and PDF4- User-defined databasesSemi-quantitative phase analysis- RIR method- Combined XRD-XRF analysisPublication-ready reportingDIFFRAC.TOPASQuantitative AnalysisDIFFRAC.TOPASStructure AnalysisQuantitative phase analysis- Crystalline phases- Amorphous phasesIndexing (LSI and LP-Search methods)Degree of crystallinitydeterminationSpiking methodPONKCS methodPawley and LeBail fittingRietveld structure refinementAb-initio structure determination- Simulated annealing- Charge Flipping- 3D Fourier analysisMicrostructure analysisD2 PHASER – X-ray diffraction tool foreveryone – everywhere!Minimal electrical powerconsumption (650 W)No cooling water supplyNo significant tube ageing –practically endless tube lifetimeMinimal space required67

XRD on polycrystalline material – more intensity with LYNXEYE detectorCommon point detector setupX-RaySourceScintillationCounterIn an XRD experimentperformed on polycrystalline material the incidentX-ray beam is diffracted byinnumerous crystallites inspecific 2Theta directions.SampleIncidentBeamD2 PHASER – dataquality, functionalityand safety withoutany compromisesDiffractedBeams2ThetaTo record the exact2Theta positions a narrowslit in front of a pointdetector is required.Advanced 1D detector setupThe LYNXEYE literallyprovides more than 150integrated slits, allowingmore than 150 2Thetapositions to be recordedsimultaneously.LYNXEYEMicro StripSensorWe give you our word: Good Diffraction Practice andBest Data Guarantee!Safety assurance:Each instrument always complies with the world’shighest statutory requirements regarding X-ray safety,machine and electrical safety. This certainty isobtained after stringent scrutiny by independentinstitutions.0.030The best in its class: the D2 PHASER.Shake on it!A simple domestic wallsocket is all you needIntensity increases by afactor of more than 150Minimum spacerequirementsNo installation100% working strips atdelivery – guaranteedHandles for convenienttransportationNo instrumentconfigurationEnergy discriminationfor sample fluorescencesuppressionMaximum X-ray safetywith radiation levelsignificantly below 1µSv/hNo infrastructureScanning and snapshotmodeClearly visible warningand operating elementsNo pre-installationrequirementsAngular coverage 5.5 2ThetaAlignment accuracybetter than 0.02 2Theta– guaranteedAll-in-one analytics:X-ray source:Island-mode:Simple sample loadingCommon sealedX-ray tube designInternal cooling systemNo alignmentWhy is this important?Accurate and verifiableinstrument alignment isa basic requirement foraccurate and reliable phaseidentification or structureanalysis.0.0100.000-0.010-0.020- 0.020 20.0040.0060.0080.00100.00120.00140.002Theta [ ]Unrivaled resolution5000SRM 660a4000FWHM 0.0421 2Θ30002000Very small peak width ofless than 0.05 2Thetaobtained by high-resolutionXRD measurement ofLaB6 (NIST SRM 660a)with LYNXEYE detector;0.1 divergence and 1.5 Soller slit.Why is this important?Good instrument resolutionis a prerequisite to resolveoverlapping diffractionpeaks in complex powderpatterns.1000029.908Desktop design:-0.040CountsWe guarantee that our 1-dimensional LYNXEYE is absolutely faultless! This is due to Bruker AXS’ uniquedetector design. By integrating the LYNXEYE detectorin the D2 PHASER it becomes the fastest and mostefficient desktop diffractometer in the world.Instrument alignment 0.02 2Theta over thewhole angular range –guaranteed!LYNXEYE detector:-0.030The D2 PHASER is pre-aligned at delivery. Everysingle instrument must pass our strict test procedure,which is based on the internationally accepted reference material corundum. The corundum reference issupplied with the instrument, so you can check yourinstrument at any time.Detector guarantee: 0.020 0.020Two independent, fail-safe safety circuits and “X-rayOn” monitors guarantee that the most recent radiation and personal safety regulations are observed.Alignment guarantee:LYNXEYE DetectorScintillation Counter0.040Deviation 2Theta [ ]Our D2 PHASER delivers uncompromisingly good and reliable analyses. Thestrict quality standards of our entireproduct range are applied to the assembling, testing and certified safety of theD2 PHASER!Instrument alignment – a sound base for accuracy!Plug’n Analyze:30.1030.3030.502Theta [ ]30.70Industrial standardsample holdersTheta/Theta geometry,horizontal samplesFully-fledgedintegrated PCLow power load –no tube ageingHigh speed ethernetconnection2 USB portsVirtually infinitetube lifetimeCr, Co, Cu radiationOn-site and remoteoperation30.909

The ultimate inease-of-use –D2 PHASER withDIFFRAC.SUITE1X-ray analysis has never been easier!Even inexperienced users produce perfectmeasurements from the very beginning thanksto the DIFFRAC.SUITE Easy-mode.13This is how X-ray analysis works in the Easy-mode:42Select COMMANDER plug-in, enter measurement timeand angular range and start. That’s all!2If a method has already been defined, it goes even faster:Select START JOBS, click on Method and off you go!Easy-mode1 Real-time measurementdisplay2 Straightforward selectionof scan parameters:- Angular range- Step size- Measurement time3 Full access to all settings:- User management- Database maintenance- Instrument configuration- Service toolsIt goes without saying that the software solutions of ourDIFFRAC.SUITE go beyond this. In Expert-mode the fullscope of functions is available. Using the COMMANDER,CONFIGURATION and TOOLS plug-in the expert has controlover administration of experimental databases, user rightsand all the way through to the Audit Trail. Everything on thesystem works in a safe, simple and reliable way.4 Full access to allinstrument parameters:- Drives- Detector settings- Generator settingsDIFFRAC.SUITE – performance made-to-measure:easy for anyone to operate, full functionalityand control for experts. Integrated within anetworked world.Expert-modeOur D2 PHASER is fully network capable. This enablesXRD experts in the central laboratory to access the data thathas been collected, no matter if they are next door or at theother end of the world. Use the D2 PHASER where it isneeded – on-site – and you will save time and money!Compatible with the entireBruker AXS’ Diffraction SolutionsfamilyFully network capableSupport of different user levelsand modesEVA – powerful phase identification10TOPAS – sophisticated quantitativephase and structure analysisAll-in-one analysisThe D2 PHASER is a full-blown diffractometer: itsmeasured data is fully compatible with all of ourDIFFRAC.SUITE solutions. The familiar world ofsearch/match and structure databases, EVA, TOPAS, all of this is available to the XRD specialist for identifying,quantifying and determining the characteristics of thecrystalline phases.D2 PHASER – Welcome to the world ofBruker AXS!11

www.aim.de 01991All configurations and specifications are subject to change without notice. Order No. : DOC-B88-EXS017. 2009 Bruker AXS. Printed in Germany.Technical DataGeometryTheta / ThetaMax. useable angular range(depending on detector)-3 160 2ThetaAccuracy 0.02 throughout the entire measuring rangeAchievable peak width 0.05 AlignmentNot needed, factory alignedX-ray wavelengthsCr / Co / Cu, standard ceramic sealed tubeX-ray generation30 kV / 10 mADetectorsScintillation counter1-dimensional LYNXEYEInstrument typePortable desktopExterior Dimension61 x 60 x 70 cm (h x d x w)24.02” x 23.62” x 27.56”Weight95 kgPower supply90 – 250 VExternal cooling water supplyNoneComputerBuilt-inOptional additional PC connected via LAN interfaceInterfaces2 x USB and 1 x LANwww.bruker-axs.comBruker AXS GmbHBruker AXS Inc.Karlsruhe, GermanyTel. 49 (7 21) 5 95-28 88Fax 49 (7 21) 5 95-45 87info@bruker-axs.deMadison, WI, USAPhone 1 (800) 234-XRAYPhone 1 (608) 276-3000Fax 1 (608) 276-3006info@bruker-axs.comD2 PHASER , DIFFRAC ,LYNXEYE , Plug’n Analyze are trademarks of Bruker AXS

D2 PHASER – Welcome to the world of Bruker AXS! The ultimate in ease-of-use – D2 PHASER with DIFFRAC.SUITE All-in-one analysis Compatible with the entire Bruker AXS’ Diffraction Solutions family Fully network capable Support of different user levels and modes EVA – powerfu

Related Documents:

Xerox Phaser 1235 . IBM InfoPrint 1145L MFP : Xerox Phaser 2135DT . IBM InfoPrint Color 8 : Xerox Phaser 3400 . IBM LaserPrinter 4039 : Xerox Phaser 3450 . IBM Network Printer 12 : Xerox Phaser 3500 . IBN Network Printer 17 : Xerox Phaser 4500DX . Konica KL-3015 : Xerox Phaser 5400 . Kyocera FS-C50 16N :

Phaser 8510/8560MFP Multifunction Product 1-2 Parts of the System This section includes: Front View on page 1-2 Side View on page 1-3 Back View on page 1-3 Open View on page 1-4 Front View Phaser 8510MFP/D Product and All Phaser 8560MFP Products Phaser 8510MFP/N Product 1. Tray 4 (optiona

PHASER 8560 EVALUATOR GUIDE 1 SECTION 1 Introducing the Xerox Phaser 8560 Solid Ink Color Printer PRODUCT OVERVIEW The Xerox Phaser 8560 solid ink color printer is a high-performance color printer based on Xerox-exclusive solid ink technology. It is designed for busy workgroups in both small and large companies. The Phaser 8560 delivers

Xerox Phaser 4622 Black-and-white Printer Detailed Specifications 1 Phaser 4622DN Phaser 4622DT Output Speed Up to 65 ppm 8.5 x 11 in. Up to 62 ppm A

2 Xerox Phaser 3635 User Guide Introduction The Xerox Phaser 3635MFP is a digital device capable of being used for copying, printing, faxing, and scanning. The features and functions available on your machine depend on the model purchased: Xerox Phaser 3635MFP/S This model provides digital copying, printing and scanning. The device supports

The Xerox Phaser 4622 is a laser printer. The Xero x Phaser 4622 prints at 65 pages per minute for Letter (62 ppm for A4). The features and functions available on your mach ine depend on the options purchased. Paper Tray 1 (Bypass) and Paper Tray 2 are provided as standard. The Duplex Unit is standard on the Xerox Phaser 4622.

The Xerox Phaser 4622 is a laser printer. The Xero x Phaser 4622 prints at 65 pages per minute for Letter (62 ppm for A4). The features and functions available on your mach ine depend on the options purchased. Paper Tray 1 (Bypass) and Paper Tray 2 are provided as standard. The Duplex Unit is standard on the Xerox Phaser 4622.

Tulang rawan yang paling banyak dijumpai pada orang dewasa. Lokasi : - Ujung ventral iga - Larynx,trachea, bronchus - Permukaan sendi tulang - Pada janin & anak yg sedang tumbuh pada lempeng epifisis Matriks tulang rawan hilain mengandung kolagen tipe II, meskipun terdapat juga sejumlah kecil kolagen tipe IX, X, XI dan tipe lainnya. Proteoglikan mengandung kondroitin 4-sulfat, kondroitin 6 .