Real-Time Spectrum Analyzerand Measurement ApplicationSpecificationsData Sheet Version 01.00R&S FSW-B512R real-time spectrum analyzer 512 MHzR&S FSW-B800R real-time spectrum analyzer 800 MHzR&S FSW-K161R real-time spectrum measurement application 160 MHzR&S FSW-K512RE real-time spectrum measurement application 512 MHzR&S FSW-K800RE real-time spectrum measurement application 800 MHzFSW-B512R-B800R-K161R-K512RE-K800RE dat-sw en 5215-7445-22 v0100 cover.indd 101.02.2019 10:41:54

Version 01.00, February 2019CONTENTSDefinitions . 3Specifications . 4Level. 7Result display . 10Trigger . 11Ordering information . 12Options for R&S FSW with order no. 1331.5003.xx . 12Upgrades . 14Recommended extras. 152Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application

Version 01.00, February 2019DefinitionsGeneralProduct data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operationSpecified environmental conditions metRecommended calibration interval adhered toAll internal automatic adjustments performed, if applicableSpecifications with limitsRepresent warranted product performance by means of a range of values for the specified parameter. These specifications aremarked with limiting symbols such as , , , , , or descriptions such as maximum, limit of, minimum. Compliance is ensured bytesting or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, driftand aging, if applicable.Specifications without limitsRepresent warranted product performance for the specified parameter. These specifications are not specially marked and representvalues with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance isensured by design.Typical data (typ.)Characterizes product performance by means of representative information for the given parameter. When marked with , or as arange, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents themean value.Nominal values (nom.)Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast totypical data, a statistical evaluation does not take place and the parameter is not tested during production.Measured values (meas.)Characterize expected product performance by means of measurement results gained from individual samples.UncertaintiesRepresent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has beencalculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into accountenvironmental conditions, aging, wear and tear.Device settings and GUI parameters are indicated as follows: “parameter: value”.Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz.Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application3

Version 01.00, February 2019SpecificationsThe specifications of the R&S FSW-B512R, R&S FSW-B800R, R&S FSW-K161R, R&S FSW-K512RE and the R&S FSW-K800REoptions are based on the specifications in the data sheet for the R&S FSW signal and spectrum analyzer. For frequencies 8 GHz,the specifications for YIG preselector off apply.The R&S FSW-K161R 160 MHz real-time measurement application requires: R&S FSW-B160 160 MHz analysis bandwidth option or R&S FSW-B320 320 MHz analysis bandwidth optionThe R&S FSW-K512RE 512 MHz real-time measurement application requires: R&S FSW-B512 512 MHz analysis bandwidth optionThe R&S FSW-K800RE 800 MHz real-time measurement application requires: R&S FSW-B1200 1200 MHz analysis bandwidth option or R&S FSW-B2001 2000 MHz analysis bandwidth optionSpanRangeR&S FSW-K161Rhigh resolution operating modemulti-domain operating modeR&S FSW-B512R, R&S FSW-K512RER&S FSW-B800R, R&S FSW-K800REResolutionFrequency readoutNumber of sweep (trace) pointsMarker resolutionUncertainty10010.01 Hz (marker frequency referenceuncertainty 10 % resolution bandwidth ½ (span/(sweep points –1)) 1 Hz)span/1000Marker tuning frequency step sizeSweep timeBlackman-Harris windowRange141 kHz to 160 MHz1 kHz to 100 MHz1 kHz to 512 MHz1 kHz to 800 MHz1 HzR&S FSW-K161Rspan/RBW ratio 200real-time spectrum, real-timespectrogram, max. spanhigh resolution operating modemulti-domain operating modeR&S FSW-B512Rspan/RBW ratio 200real-time spectrum, real-timespectrogram, 512 MHz spanR&S FSW-B800Rspan/RBW ratio 100real-time spectrum, real-timespectrogram, 800 MHz spanR&S FSW-K512REspan/RBW ratio 200real-time spectrum, real-timespectrogram, 512 MHz spanR&S FSW-K800REspan/RBW ratio 100real-time spectrum, real-timespectrogram, 800 MHz spanTime period during which individual FFTs contribute to the results of the selected trace detector.Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application51.3 µs to 1 s 153.3 µs to 1 s 151.2 µs to 334 ms 151.3 µs to 200 ms 164 µs to 334 ms 164 µs to 200 ms 1

Version 01.00, February 2019Resolution 2Data acquisitionInputOutputA/D converterSampling rateResolutionFFT lengthR&S FSW-K161Rhigh resolution operating modemulti-domain operating modeR&S FSW-B512RR&S FSW-B800RR&S FSW-K512RER&S FSW-K800RE5.2 µs4.1 µs3.42 µs3.42 µs64 µs64 µsstandardwith R&S FSW-B21 optionwith R&S FSW-B17 optionRFexternal mixerdigital baseband 3R&S FSW-B512Rspan 80 MHzspan 80 MHzR&S FSW-B800Rspan 80 MHzspan 80 MHzR&S FSW-B512Rspan 80 MHzspan 80 MHzR&S FSW-B800Rspan 80 MHzspan 80 MHzR&S FSW-K161Rhigh resolution operating modemulti-domain operating modeR&S FSW-512R/R&S FSW-K512RER&S FSW-B800R/R&S FSW-K800REFFT windowFFT overlapMax. spectrum (FFT) processing rateMinimum detectable signal durationR&S FSW-K161Rhigh resolution operating modemulti-domain operating modeR&S FSW-B512RR&S FSW-B800RR&S FSW-K512RER&S FSW-K800RER&S FSW-K161Rhigh resolution operating modemulti-domain operating modeR&S FSW-B512RR&S FSW-B800RR&S FSW-K512RER&S FSW-K800RER&S FSW-K161Rspan 160 MHz, SNR 60 dBR&S FSW-B512Rspan 512 MHz, SNR 60 dBR&S FSW-B800Rspan 800 MHz, SNR 60 dBR&S FSW-K512REspan 512 MHz, SNR 60 dBR&S FSW-K800REspan 800 MHz, SNR 60 dB2The same span and span/RBW ratio apply as for the sweep time range.3Only available for a frequency span 160 MHz.200 Msample/s1 Gsample/s200 Msample/s2.4 Gsample/s16 bit14 bit16 bit14 84/32768Blackman-Harris, Flattop, Gaussian,Rectangular, Hanning, Hamming 66.7 % 50 % 50 % 16.7 %n/an/a585 938/s244 141/s1 171 875/s2 343 750/s58 824/s58 824/s5 ns (nom.)1.67 ns (nom.)1 ns (nom.)17 µs (nom.)17 µs (nom.)Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application5

Version 01.00, February 2019Resolution bandwidthsRange 4 with Blackman-Harris windowSpan/RBW ratio with Blackman-HarriswindowR&S FSW-K161Rwith R&S FSW-B8 optionR&S FSW-B512Rwith R&S FSW-B8 optionR&S FSW-B800Rwith R&S FSW-B8 optionR&S FSW-K512REwith R&S FSW-B8 optionR&S FSW-K800REwith R&S FSW-B8 optionR&S FSW-K161Rhigh resolution operating modemulti-domain operating modeR&S FSW-B512RR&S FSW-B800RR&S FSW-K512RER&S FSW-K800REBandwidth uncertainty46The min. (max.) resolution bandwidth is defined with respect to the min. (max.) span only.Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application0.3 Hz to 10 MHz10 MHz to 25.6 MHz additionally0.3 Hz to 10 MHz10 MHz to 81.9 MHz additionally0.5 Hz to 10 MHz10 MHz to 128 MHz additionally0.3 Hz to 10 MHz10 MHz to 81.9 MHz additionally0.3 Hz to 10 MHz10 MHz to 128 MHz additionally6.25 to 32006.25 to 8006.25 to 64006.25 to 64006.25 to 64006.25 to 6400 3 % (nom.)

Version 01.00, February 2019LevelSpan 80 MHzAmplitude flatnessNonlinearity of displayed levelLevel measurement uncertaintyThird-order intermodulation distortionADC related spurious responseOther spurious responsessee R&S FSWsee R&S FSWsee R&S FSWsee R&S FSWsee R&S FSWsee R&S FSWSpan 80 MHzAmplitude flatnessR&S FSW-K161Rdata sheet, section I/Q data – Amplitude flatness 5data sheet, section I/Q data – Nonlinearity of displayed level 5data sheet, section I/Q data – Level measurement uncertainty 5data sheet, section I/Q data – Third-order intermodulation distortion 5data sheet, section I/Q data – ADC related spurious response 5data sheet, section I/Q data – Other spurious responses 5R&S FSW-B512R, R&S FSW-K512RER&S FSW-B800R, R&S FSW-K800RENonlinearity of displayed levelR&S FSW-K161RR&S FSW-B512R, R&S FSW-K512RER&S FSW-B800R, R&S FSW-K800RELevel measurement uncertainty at centerfrequencyR&S FSW-K161RR&S FSW-B512R, R&S FSW-K512RER&S FSW-B800R, R&S FSW-K800REThird-order intermodulation distortionR&S FSW-K161RR&S FSW-B512R, R&S FSW-K512RER&S FSW-B800R, R&S FSW-K800RE5678see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 160 MHz – Amplitude flatness 6see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 512 MHz – Amplitude flatness 7see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 1200 MHz – Amplitude flatness 8see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 160 MHz – Nonlinearity ofdisplayed level 6see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 512 MHz – Nonlinearity ofdisplayed level 7see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 1200 MHz – Nonlinearity ofdisplayed level 8see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 160 MHz – Level measurementuncertainty at center frequency 6see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 512 MHz – Level measurementuncertainty at center frequency 7see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 1200 MHz – Levelmeasurement uncertainty at centerfrequency 8see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 160 MHz – Third-orderintermodulation distortion 6see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 512 MHz – Third-orderintermodulation distortion 7see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 1200 MHz – Third-orderintermodulation distortion 8Span in the R&S FSW-B512R/-B800R/-K161R/-K512RE/-K800RE is referred to as “signal analysis bandwidth” in the R&S FSW data sheet, here foranalysis bandwidth 80 MHz.Span in the R&S FSW-K161R is referred to as “signal analysis bandwidth” in the R&S FSW data sheet, here for analysis bandwidth 80 MHz.Span in the R&S FSW-B512R/-K512RE is referred to as “signal analysis bandwidth” in the R&S FSW data sheet, here for a signal analysis bandwidthfrom 80 MHz to 512 MHz.Span in the R&S FSW-B800R/-K800RE is referred to as “signal analysis bandwidth” in the R&S FSW data sheet, here for a signal analysis bandwidthfrom 80 MHz to 800 MHz.Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application7

Version 01.00, February 2019R&S FSW-K161RResidual spurious responseR&S FSW-B512R, R&S FSW-K512RER&S FSW-B800R, R&S FSW-K800READC related spurious responseR&S FSW-K161RR&S FSW-B512R, R&S FSW-K512RER&S FSW-B800R, R&S FSW-K800REOther spurious responsesR&S FSW-K161RR&S FSW-B512R, R&S FSW-K512RER&S FSW-B800R, R&S FSW-K800REMinimum signal durationfor 100 % probability ofintercept with fullamplitude accuracy 9Minimum signal durationfor 100 % probability ofintercept with fullamplitude accuracy 998R&S FSW-K161Rhigh resolution operating modeBlackman-Harris window, trace detector max. peakSpanSpan/RBWSpan/RBWSpan/RBWratio 6.25ratio 50ratio 200160 MHz1.87 µs2.99 µs6.83 µs100 MHz1.96 µs3.75 µs9.9 µs80 MHz2.03 µs4.27 µs12 µs40 MHz2.35 µs6.83 µs22.2 µs20 MHz2.99 µs11.9 µs42.7 µs10 MHz4.27 µs22.2 µs83.6 µs1 MHz27.3 µs206 µs820 µsR&S FSW-K161Rmulti-domain operating modeBlackman-Harris window, trace detector max. peakSpanSpan/RBWSpan/RBWSpan/RBWratio 6.25ratio 50ratio 200100 MHz4.35 µs6.14 µs12.3 µs80 MHz4.42 µs6.66 µs14.3 µs40 MHz4.74 µs9.22 µs24.6 µs20 MHz5.38 µs14.3 µs45.1 µs10 MHz6.66 µs24.6 µs86 µs1 MHz29.7 µs209 µs823 µssee R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 160 MHz – Residual spuriousresponse 6see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 512 MHz – Residual spuriousresponse 7see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 1200 MHz – Residual spuriousresponse 8see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 160 MHz – ADC relatedspurious response 6see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 512 MHz – ADC relatedspurious response 7see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 1200 MHz – ADC relatedspurious response 8see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 160 MHz – Other spuriousresponses 6see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 512 MHz – Other spuriousresponses 7see R&S FSW data sheet, sectionI/Q data – Signal analysis bandwidth80 MHz to 1200 MHz – Other spuriousresponses 8Span/RBWratio 80027.3 µs39.6 µs47.8 µs88.8 µs171 µs335 µs3.28 msSpan/RBWratio 3200109 µs158 µs191 µs355 µs683 µs1.34 ms13.1 ms–Span/RBWratio 80049.2 µs57.3 µs98.3 µs180 µs344 µs3.29 ms––––––––––––––Events lasting shorter than the minimum signal duration specification will result in degraded level accuracy.Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application–––––––

Version 01.00, February 2019Minimum signal durationfor 100 % probability ofintercept with fullamplitude accuracy 9Minimum signal durationfor 100 % probability ofintercept with fullamplitude accuracy 9Minimum signal durationfor 100 % probability ofintercept with fullamplitude accuracy 9Minimum signal durationfor 100 % probability ofintercept with fullamplitude accuracy 9R&S FSW-B512RBlackman-Harris window, trace detector max. peakSpanSpan/RBWSpan/RBWSpan/RBWratio 6.25ratio 50ratio 200512 MHz0.91 µs1.28 µs2.56 µs160 MHz1.02 µs2.14 µs5.98 µs100 MHz1.11 µs2.9 µs9.05 µs80 MHz1.18 µs3.42 µs11.1 µs40 MHz1.5 µs5.98 µs21.3 µs20 MHz2.16 µs11.1 µs41.8 µs10 MHz3.44 µs21.4 µs82.8 µs1 MHz27.2 µs206 µs821 µsR&S FSW-B800RBlackman-Harris window, trace detector max. peakSpanSpan/RBWSpan/RBWSpan/RBWratio 6.25ratio 50ratio 200800 MHz0.46 µs0.68 µs1.88 µs512 MHz0.48 µs0.83 µs2.46 µs160 MHz0.59 µs1.71 µs5.98 µs100 MHz0.69 µs2.48 µs9.05 µs80 MHz0.75 µs2.99 µs11.1 µs40 MHz1.08 µs5.56 µs21.3 µs20 MHz1.72 µs10.68 µs41.8 µs10 MHz3.04 µs20.96 µs82.8 µs1 MHz26.4 µs205.6 µs821 µsR&S FSW-K512REBlackman-Harris window, trace detector max. peakSpanSpan/RBWSpan/RBWSpan/RBWratio 6.25ratio 50ratio 200512 MHz17 µs17 µs17 µs160 MHz17 µs17 µs17 µs100 MHz17 µs17 µs17 µs80 MHz17 µs17 µs17 µs40 MHz17 µs17 µs21.3 µs20 MHz17 µs17 µs41.8 µs10 MHz17 µs21.4 µs82.8 µs1 MHz27.2 µs206 µs821 µsR&S FSW-K800REBlackman-Harris window, trace detector max. peakSpanSpan/RBWSpan/RBWSpan/RBWratio 6.25ratio 50ratio 200800 MHz17 µs17 µs17 µs512 MHz17 µs17 µs17 µs160 MHz17 µs17 µs17 µs100 MHz17 µs17 µs17 µs80 MHz17 µs17 µs17 µs40 MHz17 µs17 µs21.3 µs20 MHz17 µs17 µs41.8 µs10 MHz17 µs20.96 µs82.8 µs1 MHz26.4 µs205.6 µs821 µsSpan/RBWratio 80010.2 µs23.9 µs36.2 µs44.4 µs85.3 µs167 µs331 µs3.28 msSpan/RBWratio 320041 µs95.6 µs145 µs178 µs341 µs669 µs1.32 ms13.12 msSpan/RBWratio 640081.9 µs191 µs289 µs355 µs683 µs1.34 ms2.65 ms26.24 msSpan/RBWratio 8007.51 µs9.82 µs23.9 µs36.2 µs44.4 µs85.3 µs167 µs331 µs3.28 msSpan/RBWratio 320030 µs39.3 µs95.6 µs145 µs178 µs341 µs669 µs1.32 ms13.12 msSpan/RBWratio 640060.1 µs78.6 µs191 µs289 µs355 µs683 µs1.34 ms2.65 ms26.24 msSpan/RBWratio 80017 µs23.9 µs36.2 µs44.4 µs85.3 µs167 µs331 µs3.28 msSpan/RBWratio 320041 µs95.6 µs145 µs178 µs341 µs669 µs1.32 ms13.12 msSpan/RBWratio 640081.9 µs191 µs289 µs355 µs683 µs1.34 ms2.65 ms26.24 msSpan/RBWratio 80017 µs17 µs23.9 µs36.2 µs44.4 µs85.3 µs167 µs331 µs3.28 msSpan/RBWratio 320030 µs39.3 µs95.6 µs145 µs178 µs341 µs669 µs1.32 ms13.12 msSpan/RBWratio 640060.1 µs78.6 µs191 µs289 µs355 µs683 µs1.34 ms2.65 ms26.24 msRohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application9

Version 01.00, February 2019Result displayResult display types with or without activefrequency mask trigger, or in anycombinationR&S FSW-K161Rhigh resolution operating modemulti-domain operating modeR&S FSW-B512R , R&S FSW-B800R,R&S FSW-K512RE, R&S FSW-K800REreal-time spectrum, persistence spectrum,real-time spectrogramreal-time spectrum, persistence spectrum,real-time spectrogram,power versus time, power versus timewaterfallreal-time spectrum, persistence spectrum,real-time spectrogram, power versus time,power versus time waterfallReal-time spectrumNumber of tracesTrace detectorTrace functionsNumber of markersMarker readout4max. peak, min. peak, average, sampleclear/write, max. hold, min. hold, view16frequency, levelPersistence spectrumPersistence bitmap resolutionPersistence bitmap color depthProbability range covered by bitmap colorsPersistence durationNumber of markersMarker readoutNumber of real-time tracesin addition to persistence spectrum displayReal-time trace detectorReal-time trace functions1001 600 points256 colorsselectable, 0 % to 100 %0 s to 8 s16frequency, level, hit probability1max. peak, min. peak, sample, averageclear/write, max. hold, min. holdSpectrogramResult displaySpectrogram bitmap color depthDynamic range covered by bitmap colorsHistory depthRecording modeTrace detectorNumber of markersMarker readoutcolor-graded bitmap240 colorsselectable, up to 200 dB (nom.)max. 100 000 frames 10single trace, continuous, frame countmax. peak, min. peak, sample16frequency, time/frame number, levelPower versus timeNumber of tracesTrace detectorTrace functionsNumber of markersMarker readout4max. peak, min. peak, average, sampleclear/write, view16time, levelPower versus time waterfallResult displaySpectrogram bitmap color depthDynamic range covered by bitmap colorsHistory depthRecording modeTrace detectorNumber of markersMarker readoutcolor-graded bitmap240 colorsselectable, up to 200 dB (nom.)max. 100 000 frames 10single trace, continuous, frame countmax. peak, min. peak, sample16time, time/frame number, level10A frame is the measurement result displayed in one row of the spectrogram. It may consist of one or more traces, depending on the set sweep count.For example, a sweep count of 2 means that two traces will be combined to one row in the spectrogram using the set trace detector.10Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application

Version 01.00, February 2019TriggerTrigger sourceR&S FSW-K161Rhigh resolution operating modemulti-domain operating modeR&S FSW-B512R, R&S FSW-B800R,R&S FSW-K512RE, R&S FSW-K800REFrequency mask triggerTrigger level resolutionMinimum required mask distance tonoise floorDynamic rangeTrigger level accuracyTrigger uncertaintyTrigger conditionsTrigger modesTrigger maskMask lengthMask frequency resolutionMask shape generationTrigger outConnectorOutputfree run, frequency mask, externalfree run, frequency mask, external,time domainfree run, frequency mask, external,time domain0.5 dB30 dB (nom.)frequency mask – reference levelfrequency mask reference level – 50 dBfrequency mask reference level – 70 dBR&S FSW-K161Rhigh resolution operating mode,span 160 MHz, span/RBW ratio 6.25multi-domain operating mode,span 100 MHz, span/RBW ratio 6.25R&S FSW-B512Rspan 512 MHz, span/RBW 6.25R&S FSW-B800Rspan 800 MHz, span/RBW 6.25R&S FSW-K512REspan 512 MHz, span/RBW 6.25R&S FSW-K800REspan 800 MHz, span/RBW 6.250 dB to –80 dB (nom.) (frequency response 1.0 dB) (nom.) (frequency response 2.5 dB) (nom.) 2.8 µs (nom.) 4.2 µs (nom.) 0.85 µs (nom.) 0.85 µs (nom.) 25 µs (nom.) 25 µs (nom.)enter mask area, leave mask areaauto rearm trigger, stop on trigger3 to 1001 frequency pointsspan/1001manual, auto set (mask derived from themeasured spectrum)BNC femaleTTL-compatible, 0 V/5 V (nom.)Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application11

Version 01.00, February 2019Ordering informationDesignationSignal and spectrum analyzer, 2 Hz to 8 GHzSignal and spectrum analyzer, 2 Hz to 13.6 GHzSignal and spectrum analyzer, 2 Hz to 26.5 GHzSignal and spectrum analyzer, 2 Hz to 43.5 GHzSignal and spectrum analyzer, 2 Hz to 50 GHzSignal and spectrum analyzer, 2 Hz to 67 GHzSignal and spectrum analyzer, 2 Hz to 85 GHz 11TypeR&S FSW8R&S FSW13R&S FSW26R&S FSW43R&S FSW50R&S FSW67R&S FSW85Order 31331.5003.501331.5003.671331.5003.85Options for R&S FSW with order no. 1331.5003.xxDesignationReal-time spectrum analyzer512 MHz, POI 15 µsTypeR&S FSW-B512ROrder No.1331.7106.16RetrofittableyesReal-time spectrum analyzer800 MHz, POI 15 µsR&S FSW-B800R1331.6400.16yesReal-time measurement application,160 MHz, POI 15 µsR&S FSW-K161R1338.2700.02yesReal-time measurement application,512 MHz, POI 15 µsR&S FSW-K512RE1338.4731.02yesReal-time measurement application,800 MHz, POI 15 µsR&S FSW-K800RE1338.7801.02yesResolution bandwidth 10 MHzR&S FSW-B81313.2464.26yes11Frequency range for R&S FSW85 with R&S FSW-B90G option: 2 Hz to 90 GHz (YIG preselector off).12Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement ApplicationRemarkscontact service center;includes 512 MHz analysisbandwidth and 200 MHz IF filter;export license requiredcontact service center;includes 2000 MHz analysisbandwidth;not available in combination withR&S FSW-B2000;export license requiredone of the R&S FSW-B160/-B320 options is needed;not available for R&S FSW-B512/-B512R/-B1200/-B2001/-B800R;no export license requiredR&S FSW-B512 required;not available for R&S FSW-B160/-B320/-B512R/-B1200/-B2001/-B800R;no export license requiredone of the R&S FSW-B1200/-B2001 options is needed;not available for R&S FSW-B160/-B320/-B512/-B512R/-B800R;no export license requiredcontact service center;for R&S FSW8/13/26;the signal analysis bandwidth isdefined by the R&S -B2001/-B800R/-B5000 options,not defined by the R&S FSW-B8option

Version 01.00, February 2019DesignationResolution bandwidth 10 MHzTypeR&S FSW-B8Order No.1313.2464.02RetrofittableyesHighpass filter for harmonicmeasurementsDigital baseband interfaceLO/IF Connections for external mixersR&S FSW-B131313.0761.02yesR&S FSW-B17R&S FSW-B211313.0784.021313.1100.28yesyesLO/IF Connections for external mixersR&S FSW-B211313.1100.86yesAnalysis bandwidth, 160 MHzAnalysis bandwidth, 320 MHzR&S FSW-B160R&S FSW-B3201325.4850.141325.4867.14yesyesAnalysis bandwidth, 512 MHzR&S FSW-B5121331.7106.14yesAnalysis bandwidth, 1200 MHzR&S FSW-B12001331.6400.14yesAnalysis bandwidth, 2000 MHzR&S FSW-B20011331.6916.14yesRemarkscontact service center;for R&S FSW43/50/67/85;the signal analysis bandwidth isdefined by the R&S -B2001/-B5000/-B800R options,not defined by the R&S FSW-B8option;export license t service center;for R&S FSW26/43/50/67contact service center;for R&S FSW85contact service centercontact service center;includes 200 MHz IF filtercontact service center;includes 200 MHz IF filtercontact service center;for R&S FSW26/-43/-50/-67/-85ex-factory;for later upgrade of R&S FSWinstruments use R&S FSW-U1200;not available in combination withR&S FSW-B2000contact service center;for R&S FSW26/-43/-50/-67/-85ex-factory;for later upgrade of R&S FSWinstruments use R&S FSW-U2001;not available in combination withR&S FSW-B2000Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application13

Version 01.00, February 2019UpgradesDesignationReal-time spectrum analyzer upgrade,from 80 MHz to 512 MHz,POI 15 µsTypeR&S FSW-U512ROrder No.1321.6320.26RetrofittableyesAnalysis bandwidth upgrade,from 28 MHz to 40 MHzAnalysis bandwidth upgrade,from 40 MHz to 80 MHzR&S FSW-U401313.5205.02yesR&S FSW-U801313.5211.02yesAnalysis bandwidth upgrade,from 80 MHz to 160 MHzR&S FSW-U1601325.5357.14yesAnalysis bandwidth upgrade,from 160 MHz to 320 MHzAnalysis bandwidth upgrade,from 80 MHz to 512 MHzR&S FSW-U3201313.7189.02yesR&S FSW-U5121321.6320.24yesAnalysis bandwidth upgrade,from 80 MHz, 160 MHz, 320 MHz,512 MHz to 1200 MHzR&S FSW-U12001331.7006.14yesAnalysis bandwidth upgrade,from 1200 MHz to 2000 MHzR&S FSW-U20011331.7070.02yes14Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement ApplicationRemarkscontact service center;includes 512 MHz analysisbandwidth;R&S FSW-B80 or R&S FSW-U80required;export license requireduser-retrofittable;R&S FSW-B28 requireduser-retrofittable;R&S FSW-B40 or R&S FSW-U40requiredcontact service center;R&S FSW-B80 or R&S FSW-U80requireduser-retrofittable;R&S FSW-B160/-U160 requiredcontact service center;R&S FSW-B80 or R&S FSW-U80required;excludes R&S FSW-B160/-U160/-B320contact service center;for R&S FSW26/-43/-50/-67/-85;R&S FSW-B80 orR&S FSW-B160/-U160 orR&S FSW-B320/-U320 orR&S FSW-B512/-U512 requirednot available for instruments withR&S FSW-B512R,R&S FSW-U512R,R&S FSW-B2000,R&S FSW-U2000user-retrofittable;R&S FSW-B1200 orR&S FSW-U1200 required

Version 01.00, February 2019Recommended extrasDesignationTypeOrder No.External harmonic mixers from RPG 12(for R&S FSW26, R&S FSW43, R&S FSW50, R&S FSW67 and R&S FSW85 with R&S FSW-B21 option)Harmonic mixer, 40 GHz to 60 GHzRPG FS-Z601048.0171.02Harmonic mixer, 50 GHz to 75 GHzRPG FS-Z753638.2240.02Harmonic mixer, 60 GHz to 90 GHzRPG FS-Z903638.2270.02Harmonic mixer, 75 GHz to 110 GHzRPG FS-Z1103638.2292.02Harmonic mixer, 90 GHz to 140 GHzRPG FS-Z1403622.0708.02Harmonic mixer, 110 GHz to 170 GHzRPG FS-Z1703622.0714.02Harmonic mixer, 140 GHz to 220 GHzRPG FS-Z2203593.3250.02Harmonic mixer, 220 GHz to 325 GHzRPG FS-Z3253593.3267.02Harmonic mixer, 325 GHz to 500 GHzRPG FS-Z5003593.3273.02For R&S FSW data sheet see PD 5215.6749.22,for R&S FSW product brochure, see PD 5215.6749.12 and www.rohde-schwarz.com12RPG is the abbreviation of Radiometer Physics GmbH, a Rohde & Schwarz company.Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application15

Service that adds valueWorldwideLocal and personalized Customized and flexible Uncompromising quality Long-term dependability Rohde & SchwarzThe Rohde & Schwarz electronics group offers innovativesolutions in the following business fields: test and measurement, broadcast and media, secure communications,cybersecurity, monitoring and network testing. Foundedmore than 80 years ago, the independent company whichis headquartered in Munich, Germany, has an extensivesales and service network with locations in more than70 countries.www.rohde-schwarz.comSustainable product design Environmental compatibility and eco-footprint Energy efficiency and low emissions Longevity and optimized total cost of ownershipCertified Quality ManagementISO 9001Certified Environmental ManagementISO 14001Rohde & Schwarz trainingwww.training.rohde-schwarz.comR&S is a registered trademark of Rohde & Schwarz GmbH & Co. KGTrade names are trademarks of the ownersPD 5215.7445.22 Version 01.00 February 2019 (fi)Real-Time Spectrum Analyzer and Measurement ApplicationData without tolerance limits is not binding Subject to change 2019 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany5215.7445.22 01.00 PDP 1 enRegional contact Europe, Africa, Middle East 49 89 4129 12345customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72)customer.support@rsa.rohde-schwarz.com Latin America 1 410 910 79 88customersupport.la@rohde-schwarz.com Asia Pacific 65 65 13 04 88customersupport.asia@rohde-schwarz.com China 86 800 810 82 28 86 400 650 58 2FSW-B512R-B800R-K161R-K512RE-K800RE dat-sw en 5215-7445-22 v0100 cover.indd 201.02.2019 10:41:55

Version 01.00, February 2019 6 Rohde & Schwarz Real-Time Spectrum Analyzer and Measurement Application Resolution bandwidths Range 4 with Blackman-Harris window R&S FSW-K161R 0.3 Hz to 10 MHz with R&S FSW-B8 option 10 MHz to 25.6 MHz additionally R&S FSW-B512R 0.3 Hz to 10 MHz with R&S FSW-B8 option 10 MHz to 81.9 MHz

Related Documents:

Fig. 5. Using a package for spectrum analyzer with a EMI diagnosis kits to execute the pretest will make EMI/EMC certification to pass smoothly. Chapter 2. The Super-heterodyne Spectrum Analyzer The super-heterodyne spectrum analyzer, sometimes called a scanning spectrum analyzer or sweeping spectrum analyzer, operates on the principle of the

User Manual I SSA3000X Plus Spectrum Analyzer SSA3000X-R Real-Time spectrum Analyzer SVA1000X Spectrum & Vector Network Analyzer User Manual UM0703P-E02A . User Manual I . Avant de relier l'instrument, lisez svp le manuel soigneusement pour obtenir plus d'informations sur les estimations.

4 Rohde & Schwarz R&S FSVR Real-Time Spectrum Analyzer Specifications Operating modes signal and spectrum analyzer real-time spectrum analyzer Specifications for all operating modes Frequency Frequency range R&S FSVR7 DC-coupled 10 Hz to 7 GHz AC-coupled 1 MHz to 7 GHz R&S FSVR13 DC-coupled 10 Hz to 13.6 GHz AC-coupled 10 MHz to 13.6 GHz

Type Handheld spectrum analyzer Universal spectrum analyzer from the Family 300 General-purpose spectrum analyzer High-performance spectrum analyzer High-performance signal analyzer Frequency range 100 kHz to 6 GHz 9 kHz to 3 GHz 9 kHz to 40 GHz 20 Hz to 50 GHz 20 Hz to 40 GHz With external mixer – – up to 1.12 THz1) up to 1.12 THz1) up to .

2 Choosing the Right Spectrum Analyzer Figure 2. Swept spectrum analyzer block diagram Figure 3. Swept spectrum analyzer example with pulse noise Figure 4. Swept spectrum analyzer with impulse noise and DOCSIS carrier In Figure 2, when the ramp generator is generating zero volts, the VCO is set to 2 GHz. Any signal at DC is up-converted to 2 GHz.

Jul 31, 2014 · VSA Vector signal analyzer SA Spectrum analyzer VNA Vector signal analyzer TG/SA Tracking generator/spectrum analyzer SNA Scalar network analyzer NF Mtr. Noise-figure meter Imped. An. Impedance analyzer (LCR meter) Power Mtr. Power meter Det./Scope Diode detector/oscilloscope Measure

We will begin with an overview of spectrum analysis. In this section, we will define spectrum analysis as well as present a brief introduction to the types of tests that are made with a spectrum analyzer. From there, we will learn about spectrum analyzers in term s of File Size: 1MBPage Count: 86Explore furtherSpectrum Analysis Basics, Part 1 - What is a Spectrum .blogs.keysight.comSpectrum Analysis Basics (AN150) Keysightwww.keysight.comSpectrum Analyzer : Working Principle, Classfication & Its .www.elprocus.comFundamentals of Spectrum Analysis - TU Delftqtwork.tudelft.nlRecommended to you b

a spectrum analyzer, and an optional impedance analyzer. Take an innovative approach to evaluating electronic components and circuits. The Agilent Technologies combination analyzers family combines three analyzer functions in one powerful instrument: a vector network analyzer, a spectrum analyzer