SECTION 00 9112 - ADDENDUM NUMBER 2 PARTICULARS

2y ago
41 Views
2 Downloads
4.55 MB
15 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Adele Mcdaniel
Transcription

SECTION 00 9112 - ADDENDUM NUMBER 2PARTICULARS1.01 DATE: NOVEMBER 30, 20171.02 PROJECT: USC BARRINGER HOUSE MECHANICAL RENOVATION1.03 OWNER'S PROJECT NUMBER: H27-Z3351.04 OWNER : THE UNIVERSITY OF SOUTH CAROLINA1.05 ARCHITECT: GMK ASSOCIATES, INC.TO: PROSPECTIVE BIDDERS :2.01 THIS ADDENDUM FORMS A PART OF THE CONTRACT DOCUMENTS AND MODIFIES THEORIGINALPROCUREMENT DOCUMENTS DATED OCTOBER 25, 2017, AND ADDENDUMNUMBER 1 ISSUED NOVEMBER 28, 2017 , WITH AMENDMENTS AND ADDITIONS NOTEDBELOW.2.02 ACKNOWLEDGE RECEIPT OF THIS ADDENDUM IN THE SPACE PROVIDED IN THE BIDFORM . FAILURE TO DO SO MAY DISQUALIFY THE BIDDER.2.03 THIS ADDENDUM CONSISTS OF 2 PAGES AND THE FOLLOWING ATTACHMENTS:A.Drawing A6.0B.Drawing A8.0C.Drawing P0.0D.Drawing P1.0.1E.Drawing P2.0.1F.Drawing P3.0.1G.Drawing M1.0H.Drawing M1.1I.Drawing M1.2J.Drawing M2.0K.Drawing M2.1L.Drawing M2.2M. Drawing M7.1CHANGES TO THE DRAWINGS/PROJECT MANUAL:3.01 DRAWING A6.0 - ENLARGED PLANS AND INTERIOR ELEVATIONSA.Replace the existing drawing A6.0 in its entirety with the revised attached drawing A6.0.1. Doors were revised to match the door schedule.3.02 DRAWING A8.0 - DOOR SCHEDULE, DOOR AND FRAME TYPESA.Replace the existing drawing A8.0 in its entirety with the revised attached drawing A8.0.1. Door sizes were revised.3.03 DRAWING P0.0 - PLUMBING DETAILS, GENERAL NOTES, PLUMBING LEGEND &ABBREVIATIONSA.Replace the existing drawing P0.0 in its entirety with the revised attached drawing P0.0.1. The Owner will construct the domestic water line to within 5'-0" of the building foundationwall. The Contractor is to connect to the Owner supplied domestic water line at 5'-0"outside of the building as indicated.3.04 DRAWING P1.0.1 - PLUMBING DEMOLITION BELOW BASEMENT FLOOR PLANA.Replace the existing drawing P1.0.1 in its entirety with the revised attached drawing P1.0.1.H27-Z335 / USC Barringer House Mechanical RenovationADDENDUM NUMBER 200 9112 - 1

1.The Owner will construct the domestic water line to within 5'-0" of the building foundationwall. The Contractor is to connect to the Owner supplied domestic water line at 5'-0"outside of the building as indicated.3.05 DRAWING P2.0.1 - PLUMBING WASTE & VENT PIPING BELOW BASEMENT FLOOR PLANA.Replace the existing drawing P2.0.1 in its entirety with the revised attached drawing P2.0.1.1. The Owner will construct the domestic water line to within 5'-0" of the building foundationwall. The Contractor is to connect to the Owner supplied domestic water line at 5'-0"outside of the building as indicated.3.06 DRAWING P3.0.1 - PLUMBING DOMESTIC WATER PIPING BELOW BASEMENT FLOOR PLANA.Replace the existing drawing P3.0.1 in its entirety with the revised attached drawing P3.0.1.1. The Owner will construct the domestic water line to within 5'-0" of the building foundationwall. The Contractor is to connect to the Owner supplied domestic water line at 5'-0"outside of the building as indicated.3.07 DRAWING M1.0 - HVAC DEMOLITION BASEMENT PLANA.Replace the existing drawing M1.0 in its entirety with the revised attached drawing M1.0.1. Revisions to the demolition, ductwork and diffusers are indicated.3.08 DRAWING M1.1 - HVAC DEMOLITION FIRST FLOOR PLANA.Replace the existing drawing M1.1 in its entirety with the revised attached drawing M1.1.1. Revisions to the demolition, ductwork and diffusers are indicated.3.09 DRAWING M1.2 - HVAC DEMOLITION SECOND FLOOR PLANA.Replace the existing drawing M1.2 in its entirety with the revised attached drawing M1.2.1. Revisions to the demolition, ductwork and diffusers are indicated.3.10 DRAWING M2.0 - HVAC RENOVATION BASEMENT PLANA.Replace the existing drawing M2.0 in its entirety with the revised attached drawing M2.0.1. Revisions to the demolition, ductwork and diffusers are indicated.3.11 DRAWING M2.1 - HVAC RENOVATION FIRST FLOOR PLANA.Replace the existing drawing M2.1 in its entirety with the revised attached drawing M2.1.1. Revisions to the demolition, ductwork and diffusers are indicated.3.12 DRAWING M2.2 - HVAC RENOVATION SECOND FLOOR PLANA.Replace the existing drawing M2.2 in its entirety with the revised attached drawing M2.2.1. Revisions to the demolition, ductwork and diffusers are indicated.3.13 DRAWING M7.1 - HVAC NOTES & SCHEDULESA.Replace the existing drawing M7.1 in its entirety with the revised attached drawing M7.1.1. Revisions to the demolition, ductwork and diffusers are indicated.END OF ADDENDUM NUMBER 2H27-Z335 / USC Barringer House Mechanical RenovationADDENDUM NUMBER 200 9112 - 2

T FLOOR0' - 0"A2.1INT. ELEV - 114 WOMEN'S TOILET NORTH41/4" 1'-0"A2.1INT. ELEV - 114 WOMEN'S TOILET EAST51/4" 1'-0"A2.1GB36WT4FIRST FLOOR0' - 0"WT413GB18GB42WT3WT2WT1QFIRST FLOOR0' - 0"51'-6"P1WBP5WT1WT3REPAIR ANDREPAINT EXISTINGCROWN MOLDING.PAINT P1P5TPP5P5FIRST FLOOR0' - 0"4A6.0A10.0P1WT4WOMEN'STOILETREPAIR AND REPAINTEXISTING CROWNMOLDING. PAINT P12'-10"1'-6"REPAIR ANDREPAINT EXISTINGCROWN MOLDING.PAINT P14'-0"REPAIR ANDREPAINT EXISTINGCROWN MOLDING.PAINT P1P5GMKSim2'-10"1'-6"24'-0"1'-6"5'-1 1/4"0'-2"1'-6"4'-6 3/4"4'-0"4'-7"1'-0"5'-0"INT. ELEV - 114 WOMEN'S TOILET SOUTH61/4" 1'-0"A2.1INT. ELEV - 114 WOMEN'S TOILET WESTA S S O C I A T E S, I N C.Architects/Engineers/Planners1201 Main Street, Suite 2100Columbia, S.C. 29201tel. 803-256-0000fax 803-255-7243ALL RIGHTS RESERVED. THIS DRAWING AND THE DESIGN SHOWNTHEREON ARE COPYWRITED AS PRESCRIBED BY THE LAWS OFTHE UNITED STATES AND ARE THE PROPERTY OF GMK ASSOCIATESARCHITECTURAL DIVISION. ANYONE DUPLICATED, REPRODUCINGOR CAUSING TO BE REPRODUCED THE WHOLE OR PART OF THESEDRAWINGS OR THE DESIGN THEREON WITHOUT THE PERMISSION OFTHE ARCHITECT WILL BE SUBJECT TO LEGAL ACTION.consultants1/4" 1'-0"1'-0"min.5'-7 1/2"7SDUNDER COUNTER ADAHEIGHT 2PTDWT4FIRST FLOOR0' - 0"2'-1 1/2"PARTITIONWT2WT2QWT1H1013'-6"P1PTDCORRIDORFIRST FLOOR0' - 0"TPMRQP5FIRST FLOOR0' - 0"WT41091'-8"81INT. ELEV - 113 PREFUNCTION ROOM WET BAR7119A6.0A2.181/4" 1'-0"A2.1INT. ELEV - 112 MEN'S TOILET NORTH91/4" 1'-0"A2.1INT. ELEV - 112 MEN'S TOILET EAST101/4" 1'-0"A2.1USC CAMPUS PLANNING ANDCONSTRUCTION743 GREENE STREETCOLUMBIA, SC 29208WT41MEN'STOILETownerTTDWT1WT1FIRST FLOOR0' - 0"REPAIR AND REPAINTEXISTING CROWNMOLDING. PAINT P1REPAIR AND REPAINTEXISTING CROWNMOLDING. PAINT P1REPAIR AND REPAINTEXISTING CROWNMOLDING. PAINT P10'-5"A10.0Sim2REPAIR AND REPAINTEXISTING CROWNMOLDING. PAINT P14'-0"A10.0Sim32'-10"Sim1INT. ELEV - 112 MEN'S TOILET SOUTH1/4" 1'-0"project nameBARRINGER HOUSEMECHANICAL RENOVATIONstate project numberPROJECT # H27-Z33510WB5'-0"3'-2"EQEQEQEQ17A6.0P118GMK project numberREPAIR AND REPAINTEXISTING CROWN MOLDING.PAINT P1PROJECT # 16070.02P5seals/signature1'-6"5'-0"3'-3"3'-1 7/8"GB18GB42GB363'-1 7/8"WT3WT2QTTDWT1FIRST FLOOR0' - 0"WT4ENLARGED PLAN - FIRST FLOOR TOILET ROOMS1A2.11/4" 1'-0"11A2.1INT. ELEV - 112 MEN'S TOILET WEST1/4" "1'-6"14WDB2WDB2ENLARGED PLAN - SECOND FLOOR TOILETA2.2121/4" 1'-0"A2.2WDB2WDB2SECOND FLOOR12' - 0"2ACCESSORIES LEGENDP5SECOND FLOOR12' - 0"INT. ELEV - 209 TOILET NORTH131/4" 1'-0"A2.2SECOND FLOOR12' - 0"INT. ELEV - 209 TOILET EAST141/4" 1'-0"A2.2SECOND FLOOR12' - 0"INT. ELEV - 209 TOILET SOUTH151/4" YLEMRMIRROR36" x 66"BLACK FRAMEDissued forPTDPAPER TOWEL DISPENSERBOBRICKB-43949CONSTRUCTION DOCUMENTSSDSOAP DISPENSERGOJOLTX-12, 1919-04TTDTOILET TISSUE DISPENSERCASCADESTANDEM 4259, BLACKdateSNDSANITARY NAPKIN RECEPT.BOBRICKB27010/25/2017GB1818" GRAB BARBOBRICKGB4242" GRAB BARBOBRICKnumberGB3636" GRAB BARBOBRICK1itemdateADDENDUM #211/30/2017INT. ELEV - 209 TOILET WEST1/4" 1'-0"1P4P1P1P11P11P1P11STAIN TOMATCHEXISTINGFINISHP1P1P1P1EXISTING DOOR ANDHARDWARE TOREMAIN, REPAIR ANDREFINISHP1P1key planOPENOPENP41 PIECE 3" CUSTOMPROFILE, MATCHEXISTINGFIRST FLOOR0' - 0" 3 PIECE 8" CUSTOM103P4P1NOTE: REPAIR AND REPAINT EXISTING CROWN, CHAIR RAIL ANDBASE MOLDING. IF EXISTING MOLDING IS NOT SUFFICIENT,MATCH EXISTING CUSTOM PROFILES.PROFILE, MATCH EXISTING16A2.1INT. ELEV - H101 CORRIDOR 01P1P1P4P4FIRST FLOOR0' - 0"1/4" 1'-0"P117A2.1P1OPENINT. ELEV - H101 CORRIDOR 02P4P1P4P1NOTE: REPAIR AND REPAINT EXISTING CROWN, CHAIR RAIL ANDBASE MOLDING. IF EXISTING MOLDING IS NOT SUFFICIENT,MATCH EXISTING CUSTOM PROFILES.P4FIRST FLOOR0' - 0"P1P1181/4" 1'-0"P4A2.1P1INT. ELEV - H101 CORRIDOR 03NOTE: REPAIR AND REPAINT EXISTING CROWN, CHAIR RAIL ANDBASE MOLDING. IF EXISTING MOLDING IS NOT SUFFICIENT,MATCH EXISTING CUSTOM PROFILES.1/4" 1'-0"P1P1P1P111P11OPENOPENP1P4P1FIRST FLOOR0' - 0"19A2.1P1P4P1INT. ELEV - H101 CORRIDOR 041/4" 1'-0"sheet titleP4P1P4NOTE: REPAIR AND REPAINT EXISTING CROWN, CHAIR RAIL ANDBASE MOLDING. IF EXISTING MOLDING IS NOT SUFFICIENT,MATCH EXISTING CUSTOM PROFILES.FIRST FLOOR0' - 0"20A2.1INT. ELEV - H101 CORRIDOR 05ENLARGED PLANS AND INTERIORELEVATIONSP4NOTE: REPAIR AND REPAINT EXISTING CROWN, CHAIR RAIL ANDBASE MOLDING. IF EXISTING MOLDING IS NOT SUFFICIENT,MATCH EXISTING CUSTOM PROFILES.sheet number1/4" 1'-0"A6.0drawn bychecked byMAPTMW

GMKDOOR SCHEDULEROOM NAMEDOOR LECTRICALFIRST FLOORFOYERSTUDYMECH.JANITORMEN'S TOILETPREFUNCTION ROOMWOMEN'S TOILETWOMEN'S TOILETDOOR ELEVDOOR SIZEFRAME ELEVHDWR SET001002003004005A8A1J1A1A148" x 80"36" x 80"72" x 80"36" x 80"36" x 80"aafaa53653100103OPEN-36" x 80"48" x 90"b--106108109110111112A3AAAAA30" x 80"32" x 80"36" x 80"36" x 80"36" x 80"36" x 80"bbbbbb332221REMARKSEXISTING.REPAIR AND REFINISH EXISTING DOOR, HARDWARE& FRAMEA1SET NO. 3 STORAGE SETHINGESMORTISE LOCKSETSILENCERSBUMPERSET NO. 2 PASSAGE SET WITH DEADBOLT FUNCTIONHINGESCLOSERMORTISE LOCKSETSILENCERSBUMPERSET NO. 4 PASSAGE SETHINGESMORTISE LOCKSET ACTIVE LEAFFLUSH BOLT INACTIVE 201 Main Street, Suite 2100Columbia, S.C. 29201tel. 803-256-0000fax 803-255-72432HARDWARE SETSSET NO. 1 PASSAGE SETHINGESMORTISE LOCKSETSILENCERSBUMPERA S S O C I A T E S, I N C.PANELED DOOR FORTYPES A & J ONLY.MATCH PANELING OFEXISTING DOORS.SET NO. 5 EXIT DOOR SETHINGESMORTISE LOCKSETPANIC DEVICECLOSERSILENCERSBUMPERSET NO. 6 STORAGE SETHINGESMORTISE LOCKSET ACTIVE LEAFFLUSH BOLT INACTIVE LEAFSILENCERSBUMPERSJWD- PANELSWD- PANELSA1MTL- NO LABELJ1MTL- NO LABELA2WD- 3/4 HR. "C" LABELJ2WD- 3/4 HR. "C" LABELA3MTL- 3/4 HR. "C" LABELJ3MTL- 3/4 HR. "C" LABELALL RIGHTS RESERVED. THIS DRAWING AND THE DESIGN SHOWNTHEREON ARE COPYWRITED AS PRESCRIBED BY THE LAWS OFTHE UNITED STATES AND ARE THE PROPERTY OF GMK ASSOCIATESARCHITECTURAL DIVISION. ANYONE DUPLICATED, REPRODUCINGOR CAUSING TO BE REPRODUCED THE WHOLE OR PART OF THESEDRAWINGS OR THE DESIGN THEREON WITHOUT THE PERMISSION OFTHE ARCHITECT WILL BE SUBJECT TO LEGAL ACTION.A4WD- 1-1/2 HR. "B"LABELJ4WD- 1-1/2 HR. "B"LABELconsultantsA5MTL- 1-1/2 HR. "B"LABELJ5MTL- 1-1/2 HR. "B"LABELA6WD- 3 HR. "A"LABELJ6WD- 3 HR. "A"LABELA7MTL- 3 HR. "A"LABELJ7MTL- 3 HR. "A"LABELA8MTL- EXTERIOR INSULATEDJ8MTL- EXTERIOR INSULATEDA9WD- 20 MIN. CERTIFIEDCONSTRUCTIONJ9WD- 20 MIN. CERTIFIEDCONSTRUCTIONA10A11TYPES1 DOORNOTES:WD- 20 MIN. CERTIFIEDCONSTRUCTION- 7'-10" HIGH1. ASTRAGAL REQUIRED AT DOUBLE EGRESS DOORS2. ALL EXTERIOR DOORS TO BE HOT DIPPED GALVANIZED DOOR AND FRAMEMTL- 3 HR. "A" LABEL1CL HOSPITAL ARMPULL (LOWER BASE& PUSH PLATE)7-1/8"3/A8.01/A8.02USC CAMPUS PLANNING ANDCONSTRUCTION743 GREENE STREETCOLUMBIA, SC 29208project nameBARRINGER HOUSEMECHANICAL RENOVATIONCL DEADLOCKSTRIKE4/A8.0EQUAL2/A8.0ownerstate project numberPROJECT # H27-Z335GMK project numberPROJECT # 16070.02g42"40 /-5"7 1/8"3/A8.01/A8.04/A8.0STANDARD STOPSseals/signatureCL PUSH BAR& PULLCL STRIKE FORKNOB LOCKS,HANDLE SETS,ROLLER LATCHES,& EXIT DEVICES2/A8.0THREE HINGE DIM.& MODIFY FOR FOURSTANDARD STOPSwith wood frameDOOR HARDWARE3 LOCATIONSFRAME TYPES2 NOTES:LABELED DOORS REQUIRE LABELED FRAMESINSULATED GLASS AT EXTERIOR 2" MASONRYWOOD HEAD JAMB CASING TO MATCHEXISTING OR REUSE EXISTING.CONTRACTOR'S OPTION.1/2"5/8" GYP.BD.1/2"5/8" GYP.BD.5/8" GYP.BD.issued forSEALANTCONSTRUCTION DOCUMENTSdate2" GYP. BD.4" MASONRY5/8"10/25/20171 15/16"HEAD DETAILJAMB DETAIL1 15/16"1/2"24 "Z" CLIPSPER JAMBdate1ADDENDUM #111/28/20172ADDENDUM #211/30/2017HEAD DETAILSEALANT5/8" GYP. BD.5/8" GYP. BD.5/8" GYP. BD.itemWOOD HEAD JAMB CASING TO MATCHEXISTING OR REUSE EXISTING.CONTRACTOR'S OPTION.2"5/8"1/2"5/8"GYP.BD. ORMASONRYPART.2"1/2"SEALANT5/8" GYP. BD.1 15/16"1/2"13number1 15/16"1 15/16"1 15/16"44 "Z" CLIPSPER JAMB1 15/16"5/8"1 15/16"15/8" GYP.BD.SEALANTGYP.BD. ORMASONRYPART.f45"60"bSTANDARD STOPSEQUALaSTANDARD STOPSwith wood framekey planJAMB DETAILDETAILS6 HEAD/JAMBNOTE: GROUT ALL FRAMES SOLID.sheet titleDOOR SCHEDULE, DOOR AND FRAMETYPESsheet numberA8.0drawn bychecked byMAPTMW

h27-z335 / usc barringer house mechanical renovation 00 9112 - 1 addendum number 2 section 00 9112 - addendum number 2 particulars 1.01 date: november 30, 2017 1.02 project: usc barringer house mechanical renovation 1.03 owner's project number: h27-z335 1.04 owner : the university of south carolina 1.05 architect: gmk associates, inc.

Related Documents:

Re: ADDENDUM SEVEN - DELAWARE STATE POLICE - TROOP 3- BID PACK 1 Dover, Delaware 2011116.00 ADDENDUM SEVEN The addendum forms a part of the contract documents and modifies the original bidding documents dated, October 9, 2013, modified by Addendum No. 1 dated 10-18-2013, Addendum No. 2 dated

2900 Olney Sandy Spring Rd Olney MD 20832 301-774-9112 www.stpetersschoololney.org Dear Parent or Guardian: Saint Peter's School values parents who are committed to participation in our school's programs and events. Parent volunteers are vital to the success of many of the programs that make our school

Services 14-19 ("WSCA-NASPO Master Agreement" or "Master Agreement"). The Master Agreement, as now or hereafter amended, is incorporated into this addendum ("Participating Addendum") as if set forth at length. This Participating Addendum covers the Data Communications Products and Services contracts led by the

1 New Relic Data Processing Addendum This Data Processing Addendum (Addendum _) including its Exhibits and Appendices forms part of the agreement (Agreement _) for the purchase of services between New Relic, Inc. a Delaware corporation with offices located at 188 Spear Street, Suite 1200, San Francisco, CA 94105 ( New Relic _) and the entity identified as Customer on

Request for Proposal: Multiple Site Landscape Maintenance Services Addendum Number: Three DATE: 12/18/2020 To All Potential Proposers: This addendum is issued to modify the previously issued Request for Proposal, and is hereby made a part of the RFP document. Please attach this addendum to the documents in your possession and consider the

Addendum conflicts with any provision of the Agreement, the provisions of this Addendum shall prevail. All terms used in this Addendum shall have the same meaning as in the Agreement. 1. MANDATORY SOLAR ENERGY SYSTEMS. California Code of Regulations (CCR), Title 24imposes energy efficiency standards on the construction of new homes in California.

Addendum Chart of the Kings of the 18th Dynasty of Egypt (from College Press) Addendum Constable’s Identification of Significant Pharaohs Addendum Addendum The Book of Exodus—an Excellent One-Page Visual (a graphic) Beginning of Document Preface and

être imposées à l'alimentation dans le cas d'un additif, pesticide, ou d'autres contenus qui sont interdites au Japon, alors que leurs niveaux dépassent les limites approuvées, ou lorsque la présence de mycotoxines, etc. est au-dessus des niveaux admissibles. Par conséquent, les aliments santé et des compléments alimentaires doit être vérifiée sur le site de production avant l .