Field Xpert SMT70 - Portal.endress

2y ago
20 Views
2 Downloads
614.00 KB
12 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Jerry Bolanos
Transcription

cesTechnical InformationField Xpert SMT70Universal, high-performance tablet PC for deviceconfigurationApplicationYour benefitsThe Field Xpert SMT70 tablet PC for device configurationenables mobile plant asset management in hazardous andnon-hazardous areas. It is suitable for commissioning andmaintenance staff to manage field instruments with a digitalcommunication interface and to record progress. This tablet PCis designed as a complete solution and is an easy-to-use,touch-enabled tool which can be used to manage fieldinstruments during their entire life cycle. It provides extensive,pre-installed driver libraries and offers access to the "IndustrialInternet of Things" as well as to information anddocumentation during the entire life cycle of the device. FieldXpert SMT70 offers a modern software user interface and theoption of online updates based on a secure Microsoft Windows10 multi-functional environment. High-performance, robust tablet with large 11.6" display anda battery runtime of up to 14 hours. Touch-enabled device configuration software in 20languages. Includes NAMUR NE 107 instrument diagnosis. Pre-installed device driver libraries for all of the importantindustrial protocols. Fast connection to devices with a single click. Automatic hardware detection saves time. Integrated Heartbeat Verification incl. PDF documentation. Online application software update service offers newfunctionality and maximum security.

Field Xpert SMT70Table of contentsAbout this document . . . . . . . . . . . . . . . . . . . . . . . .3Safety symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Symbols for certain types of information . . . . . . . . . . . . . . 3Function and system design . . . . . . . . . . . . . . . . . . . 3Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3System design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Communication and data processing . . . . . . . . . . . . . . . . . 6Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .777Performance characteristics . . . . . . . . . . . . . . . . . . . 7Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Ambient temperature range . . . . . . . . . . . . . . . . . . . . . .Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . .Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Operating height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . .Shock resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . .Electromagnetic compatibility . . . . . . . . . . . . . . . . . . . . .88899999Mechanical construction . . . . . . . . . . . . . . . . . . . . . . 9Design, dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Software operation . . . . . . . . . . . . . . . . . . . . . . . . . 10Certificates and approvals . . . . . . . . . . . . . . . . . . .CE approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Radio approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10101010Ordering Information . . . . . . . . . . . . . . . . . . . . . . . 10Scope of delivery . . . . . . . . . . . . . . . .

HART point-to-point connection via MACTek Bluetooth modem - -1 2 4 5 3 3 Point-to-point connection via a load resistor 1 Load resistor: 250 to 1 100 Ω 2 HART device 3 Field Xpert SMT70 tablet PC 4 VIATOR Bluetooth modem 5 Trans

Related Documents:

Xpert CT/NG 1 301-0234, Rev. K August 2019 Xpert CT/NG For in vitro diagnostic use only 1 Proprietary Name Xpert CT/NG 2 Common or Usual Name Xpert CT/NG 3 Intended Use The Xpert CT/NG test, performed on the GeneXpert Instrument Systems, is a qualitative in vitro real-time PCR test for the automated detection and differentiation of genomic DNA from Chlamydia trachomatis (CT) and/or .

PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus, and Endress Hauser service protocols (CDI, ISS, IPC and PCP). The devices can be connected directly via a suitable interface e.g. a modem (point-to-point) or a bus system (point-to-bus). The Field Xpert software package is fast, easy and intuitive to use.

services and solutions for industrial process engineering. To learn more about Endress Hauser, visit: www.endress.com Flow measurement as competence The Endress Hauser group is a global player. Within the group, Endress Hauser Flowtec AG ranks interna-tionally as one of the leading producers of industrial flowmeters for liquids, gases and steam.

Siegenia Lift & Slide Patio Gear - HS Portal 413-414 17. TBT TBT Selection Guide 417-418 Siegenia Titan AF 419-420 Contents Contents Siegenia Titan AF PAS24 421-422 Siegenia Titan AF 24 423-424 Siegenia Titan AF 24 PAS24 425-426 18. T Pivots Pivot Gear Guide 429-430 T-Pivot 431-432 19. Xpert Tools Xpert Air Dentist Drill 438 Xpert Air .

PXG 900 User's Guide - Firmware Version 4.3 - 1/9/2017 2 PXG Users Guide The Power Xpert Gateway 900 (PXG) is a powerful tool for monitoring electrical systems. It can also serve as a data aggregation point if used with Eaton's Power Xpert Insight or third party s

The Portal Admin is the primary user for each Client Axcess portal. The Portal Admin may perform all portal-related functions, create other Portal Users and control access for other Portal Users. The Portal Admin user will be the only user that exists initially when a portal is created.

Jul 27, 2018 · installed driver libraries and offers access to the "Industrial Internet of Things" as well as to information and documentation during the entire life cycle of the device. The tablet PC offers . ‣ In the hazardous area, always use an Ex-tablet with the MACTek V

Gauge Field Theory Dr. Ben Gripaios CavendishLaboratory, JJThomsonAvenue, Cambridge,CB30HE,UnitedKingdom. January4,2016 E-mail: gripaios@hep.phy.cam.ac.uk. Contents 1 Avantpropos1 2 BedtimeReading2 3 Notationandconventions3 4 Relativisticquantummechanics5 4.1 WhyQMdoesanddoesn’twork5 4.2 TheKlein-Gordonequation7 4.3 TheDiracequation7 4.4 Maxwell’sequations10 4.5 .