Mirage Micro nasal maskUser GuideEnglish

EnglishMirage Micro nasal maskThank you for choosing the Mirage Micro .Rx OnlyIntended UseThe Mirage Micro channels airflow noninvasively to a patient from a positiveairway pressure device such as a continuous positive airway pressure (CPAP)or bilevel system.The Mirage Micro is: to be used by adult patients ( 66 lb/30 kg) for whom positive airwaypressure has been prescribed intended for single-patient re-use in the home environment andmultipatient re-use in the hospital/institutional environment.Before Using the MaskWARNINGS The vent holes must be kept clear. The mask should not be used unless the CPAP system is turned on andoperating properly. Follow all precautions when using supplemental oxygen. Oxygen flow must be turned off when the flow generator is not operating,so that unused oxygen does not accumulate within the flow generatorenclosure and create a risk of fire. At a fixed flow rate of supplemental oxygen flow, the inhaled oxygenconcentration varies, depending on the pressure settings, patient breathingpattern, mask, point of application and leak rate. The technical specifications of the mask are provided for your clinician tocheck that they are compatible with the flow generator. If used outsidespecification or if used with incompatible devices, the seal and comfort ofthe mask may not be effective, optimum therapy may not be achieved, andleak, or variation in the rate of leak, may affect the flow generator function. Discontinue using the Mirage Micro if you have ANY adverse reaction tothe use of the mask, and consult your physician or sleep therapist. Using a mask may cause tooth, gum or jaw soreness or aggravate anexisting dental condition. If symptoms occur, consult your physician ordentist. As with all masks, some rebreathing may occur at low CPAP pressures.1

Refer to your flow generator manual for details on settings and operationalinformation.Flow Generator SettingsSelect ‘Standard’ (or ‘Vista’ for VPAP Adapt SV ) as the mask option whenusing the Mirage Micro with ResMed flow generators that have mask settingoptions. For a full list of compatible devices for this mask, see the Mask/Device Compatibility List on www.resmed.com on the Products page underService & Support. If you do not have internet access, please contact yourResMed representative.Parts of the Mask & Ordering InformationComplete systemS* 16333 M&L* 16334 LW&XL* 16335Frame system (no headgear)S* 16378 M* 16379 L* 16380 LW* 16381 XL* 16382Frame assembly (no headgear, no cushion)S* 16383 St* 16384Foreheadsupport pad60123 (1)60124 (10)Elbow assembly (elbow, swivel)16399Forehead support16393Mask cushion16388 (S*)16389 (M*)16390 (L*)16391 (LW*)16392 (XL*)Dial61289Mask frame16395 (S*)16394 (St*)Elbow16387Swivel16565Headgear clip16569 (2)16734 (10)Ports cap16570 (2)16571 (10)Upper strapsHeadgear16118 (S*)16117 (M)16119 (L*)Lower strapsS* Small; M* Medium; L* Large; LW* Large-Wide; XL* Extra-Large; St* Standard2

1Turn the dial, so that theforehead support is fullyextended.4Unfasten the Velcro ,pull the upper headgearstraps evenly until they arecomfortable and firm, andreattach the Velcro.7Lie down in your sleepingposition. Adjust the dialuntil the mask is evenlypositioned on your face.It should be comfortable,with a satisfactory seal.Adjust the headgear strapsif necessary.23Hold the mask over yournose and pull the headgearover your head.5Bringing the lower strapsbelow your ears, connectthe headgear clip to the themask frame.6Repeat step 4 with thelower headgear straps.Connect the main airtubing to the swivel. Thenconnect the free end ofthe air tubing to your flowgenerator and turn the flowgenerator on.8The fitted mask is shownabove.3Removing the MaskDisconnect one of theheadgear clips and pull themask and headgear up overyour head.EnglishFitting the Mask

Disassembling the Mask1Detach the air tubing.423Unclip the headgear clipsand unthread the upperheadgear straps. It is notnecessary to remove theheadgear clips from theheadgear.Remove the elbowassembly from the maskframe by pivoting from thebottom edge.5(b)(a)Remove the swivel fromthe elbow.6Remove the foreheadsupport pads from theforehead support.Note the position on the dial for the next time you usethe mask. Unscrew and remove the dial (a) then pull theforehead support (b) out of the mask frame.78Remove the cushionfrom the mask frame.4Remove the ports capfrom the mask frame.

Notes: The mask and headgear should be cleaned by handwashing. The headgear may be washed without removing the headgear clips.WARNINGDo not use aromatic-based solutions or scented oils (eg, eucalyptus oressential oils), bleach, alcohol or products that smell strongly (eg, citrus)to clean any of the mask components. Residual vapours from thesesolutions can be inhaled if not rinsed thoroughly. They may also damagethe mask, causing cracks.CAUTION If any visible deterioration of a mask component is apparent (cracking,crazing, tears etc.), the mask component should be discarded andreplaced. Avoid connecting flexible PVC products (eg, PVC tubing) directlyto any part of this mask. Flexible PVC contains elements that canbe detrimental to the materials of the mask, and may cause thecomponents to crack or break.Daily/After Each UseTo optimize the mask seal, facial oils should be removed from the cushionbefore use.Handwash the mask by gently rubbing in warm (86 F/30 C) water using mildsoap.If the vent requires cleaning use a soft bristle brush.Rinse all components well with drinking quality water and allow them to airdry out of direct sunlight. Do not soak the mask.WeeklyHandwash the headgear in warm (approx. 86 F/30 C) water using mild soap.Reprocessing the Mask between PatientsThis mask should be reprocessed when used between patients.Cleaning, disinfection and sterilisation instructions are available from theResMed website, www.resmed.com/masks/sterilization/americas.If you do not have Internet access, please contact your ResMedrepresentative.5EnglishCleaning the Mask at Home

Reassembling the Mask12Insert the cushion into themask frame. Ensure thatthe arrows at base of thecushion and mask frameare aligned.Insert the ports cap.43(c)(a)Push the forehead padsfirmly into the foreheadsupport.5(b)Insert the forehead support (a) into the mask frame andscrew (b) the dial clockwise onto the pole. Turn the dialuntil it clicks (c). Ensure the dial sits flush against theframe.6Insert the assembledelbow into the mask frame.7Reattach the top headgearstraps by threading themthrough the loops.6Insert the swivel into theend of the elbow.

ProblemPossible reasonPossible solutionMask won’t sealproperlyor is uncomfortableMask may have beenfitted incorrectly or isincorrectly adjusted.Carefully follow instructionsin “Fitting the Mask”. Checkheadgear and dial are not overtightened. Extend dial to applymore force to upper lip. Shortendial to increase force at nosebridge.Mask is wrong size.Talk to your clinician.Mask cushion isskewed in mask frame.Check insertion of cushionand reinsert correctlyaccording to the instructions in“Reassembling the Mask”.Mask cushion ismisaligned or creasedon face.Ensure cushion is properlyaligned according to theinstructions in “Reassemblingthe Mask”. Make sure thecushion has no creases in it:undo headgear clip, checkcushion and reposition the maskover your nose.Mask cushion may bedirty.Clean cushion according toinstructions in “Cleaning theMask at Home”.Mask is assembledincorrectly.Reassemble mask.Vents are blocked orpartially blocked.Clean vents according toinstructions in “Cleaning theMask at Home”.Misassembly.Push dial base onto a hardsurface until the dial comes outof the frame.Mask is too noisyDial inserted into maskframe before foreheadsupportSymbolsCaution, consult accompanying documents; LOT Batch Code; REF CatalogueNumber;Temperature limitation;Humidity limitation;Does not containnatural rubber latex;Indicates a Warning or Caution and alerts you to a possibleinjury or explains special measures for the safe and effective use of the device;European Authorised g

Limited WarrantyResMed warrants that your ResMed mask system, including its components:mask frame, cushion, headgear, tubing and other accessories (“Product”) shallbe free from defects in material and workmanship for a period of ninety (90)days from the date of purchase by the initial consumer.For further details refer to the Warranty.Technical SpecificationsNote: The mask system does not contain latex, PVC or DEHP materials.Pressure–FlowCurveThe mask contains passive venting to protectagainst rebreathing. As a result of manufacturingvariations, the vent flow rate may vary.50Vent Flow Rate 10504Dead SpaceInformationPressure(cm H2O)6810121416Mask Pressure (cm H2O)1820The dead space of the mask varies according to cushion size. It is128 mL for the Extra Large size.Therapy Pressure4 to 20 cm H2OResistanceDrop in pressure measured (nominal)at 50 L/min: 0.1 cm H2Oat 100 L/min: 0.7 cm H2OEnvironmentalConditionsOperating temperature: 41 F to 104 F ( 5 C to 40 C)Operating humidity: up to 95% non-condensingStorage and transport temperature: -4 F to 140 F (-20 C to 60 C)Storage and transport humidity: up to 95% non-condensingGrossdimensionsS: 140 mm (H) x 91 mm (W) x 93 mm (D)M, L, LW, XL: 155 mm (H) x 91 mm (W) x 98 mm (D)Mask fully assembled – no headgear.Note: The manufacturer reserves the right to change these specificationswithout notice.StorageEnsure that the mask is thoroughly clean and dry before storing it for anylength of time. Store the mask in a cool dry place out of direct sunlight.DisposalThe Mirage Micro does not contain any hazardous substances and may bedisposed of with your normal household refuse.8

Manufacturer:ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 AustraliaFor patent information, see www.resmed.com/ip.AutoSet CS, Mirage and Mirage Micro are trademarks of ResMed Ltd.Velcro is a registered trademark of Velcro Industries B.V. 2017 ResMed Ltd.

123456618114/4 2017-08MIRAGE MICROUSERAMER - MULTI618114Global leaders in sleep and respiratory medicine   www.resmed.com

Flow Generator Settings Select ‘Standard’ (or ‘Vista’ for VPAP Adapt SV ) as the mask option when using the Mirage Micro with ResMed flow generators that have mask setting options. For a full list of compatible devices for this mask, see the Mask/ Device Compatibility List on www.resmed

Related Documents:

Amazon SageMaker Amazon Transcribe Amazon Polly Amazon Lex CHATBOTS Amazon Rekognition Image Amazon Rekognition Video VISION SPEECH Amazon Comprehend Amazon Translate LANGUAGES P3 P3dn C5 C5n Elastic inference Inferentia AWS Greengrass NEW NEW Ground Truth Notebooks Algorithms Marketplace RL Training Optimization Deployment Hosting N E W AI & ML

Why Amazon Vendors Should Invest In Amazon Marketing Services 7 The Amazon Marketing Services program provides vendors an opportunity to: Create engaging display ad content Measure ad content success Reach potential customers throughout Amazon and Amazon-owned & operated sites Amazon Marketing Services offers targeting options for vendors to optimize their

Amazon Web Services AbouttheTutorial Amazon Web Services (AWS) is Amazon's cloud web hosting platform that offers flexible, reliable, scalable, easy-to-use, and cost-effective solutions. This tutorial covers various important topics illustrating how AWS works and how it is beneficial to run your website on Amazon Web Services. Audience

Amazon Web Services Tao Chen Amazon Web Services Fan Ping Amazon Web Services Abstract Starting in 2013, we set out to build a new database to act as the configuration store for a high-performance cloud block storage system (Amazon EBS).This database needs to be not only highly available, durable, and scalable but also strongly consistent.

You can offer your products on all Amazon EU Marketplaces without having to open separate accounts locally. Amazon Marketplaces include Amazon.co.uk, Amazon.de, Amazon.fr, Amazon.it and Amazon.es, countries representing over 80% of European Ecommerce spend. You have a single user interface to manage your European seller account details.

Amazon Web Services (AWS) 2 September, 2021 Import Amazon Web Services Patterns Before you can start creating AWS diagrams to specify or document your Cloud services you must first import the graphics from a pattern. This will inject all the AWS icons as components into the selected location in the Browser window. Create an Amazon Web Services .

Amazon Web Services - Overview of Amazon Web Services November 2014 Page 8 of 30 party attestations. More information is available in the Risk and Compliance whitepaper and the AWS Security Center. Amazon Web Services Cloud Platform AWS consists of many cloud services that you can use in combinations tailored to your business or .

The Connector for Amazon continuously discovers Amazon EC2 and VPC assets using an Amazon API integration. Connectors may be configured to connect to one or more Amazon accounts so they can automatically detect and synchronize changes to virtual machine instance inventories from all Amazon EC2 Regions and Amazon VPCs.