VIAVI Solutions Data Sheet VIAVI T-BERD/MTS

3y ago
42 Views
2 Downloads
1.74 MB
12 Pages
Last View : 15d ago
Last Download : 3m ago
Upload by : Milo Davies
Transcription

VIAVI SolutionsData SheetVIAVI T-BERD/MTS4100-Series OTDR ModulesFor T-BERD /MTS-2000, -4000, -5800 & CellAdvisor 5G PlatformsVIAVI Solutions 4100-Series OTDR modules let fieldtechnicians rapidly, reliably, and cost-effectively install,turn up, and troubleshoot any optical network architecture—enterprise, metro, long-haul, and FTTx/access point-to-pointor point-to-multipoint passive (PONs).The OTDR modules’ optical performance, combined withthe complete suite of T-BERD/MTS and CellAdvisor 5Gplatform testing features, ensures that testing is doneright the first time.Benefitsyy Up to 45 dB dynamic range and256,000 acquisition pointsyy PON-optimized to test througha 1x256 splitterStandard testing features include:yy Automatic macrobend detectionyy Summary results table with pass/fail analysisyy Combined single-mode/multimode intoone (quad)yy Bidirectional OTDR analysisyy Single/dual/tri-wavelength versions with1310/1550/1625/1650 nmyy Fast-Report — onboard report generationyy Integrated CW light source and power meteryy Smart Link Mapper (SLM) icon-based map viewyy Ready for Enterprise-SLM, FTTA-SLM,and FTTH-SLM intelligent opticalapplication softwareof the fiber linkyy SmartAcq perform a short and long pulse acquisition toimprove measurement reliabilityyy SmartTEST Assistant guides users with an easy step bystep processT-BERD/MTS-2000one-slot handheldmodular platform fortesting fiber networksT-BERD/MTS-4000 v2Two-slot handheldmodular platform fortesting fiber networksCellAdvisor 5GCell site test solutionT-BERD/MTS-5800Handheld testinstrument for testing10 G Ethernet and fibernetworksyy Instantly detects traffic when connected tolive fiber (except on live/filtered port)yy ITU Fiber type identification (G65x A, B, C andD) with water peak detection at 1383nm

SpecificationsGeneral (typical at 25 C)Attenuation MeasurementWeight0.35 kg (0.77 lb)ModeDimensions (w x h x d)Software can be enhanced andupgraded in the fieldAutomatic, manual, 2-point, 5-point,and LSADisplay range1.25 to 55 dBDisplay resolution0.001 dBCursor resolution0.001 dBLinearity 0.03 dB/dB/ 0.05 for LAThreshold0.01 to 5.99 dB in 0.01 dB stepsOptical InterfacesInterchangeableoptical connectors1FC, SC, LC (PC or APC) and ST (PC)Technical CharacteristicsLaser safety class (21CFR)Class 1Distance unitsKilometers, feet, and milesGroup index range1.30000 to 1.70000 in0.00001 stepsNumber of data pointsReflectance/ORL Measurements- Up to 128,000 for MM, QUAD, LA- Up to 256,000 for MA2, MA3, MP2Distance measurementModeAutomatic or dual cursorDisplay range0.1 up to 400 kmCursor resolution1 cmSampling resolution4 cmAccuracy .5 m sampling resolution 1.10 5 x distance (excluding groupindex uncertainties)for MA2, MA3, MP2Reflectance accuracy 2 dBDisplay resolution0.01 dBThreshold 11 to 99 dB in 1 dB stepsSource Power Meter (optional)2CW source output powerlevel 3.5 dBmPower level range (MM/SM)3 3 to 30/0 to 55 dBmCalibrated wavelengths (SM)1310/1490/1550/1625/1650 nmCalibrated wavelengths(MM)4850/1300 nmMeasurement accuracy (SM) 0.5 dBMeasurement accuracy(MM)5 1 dB 1 m sampling resolution 1.10-5 x distance for LA, MMand QUADOTDR Modules (typical at 25 C)Central Wavelength6RMSDynamic Range7EventDead Zone8AttenuationDead Zone9ApplicationsMM850/1300 30 nm26/24 dB0.8 m4mEnterprise/FTTAMultimode network qualificationQuad850/1300 30 nm1310/1550 20 nm26/24 dB37/35 dB0.8 m0.9 m4mEnterprise/FTTA/access/metroMultimode and single-modeshort- and medium-haul networkqualificationLA1310/1550/1650 20 nm35/33/30 dB1.5 m6mFTTA/FTTH/accessShort-haul qualificationFTTH drop-cablequalification/maintenanceMA21310 20 nm1383 3 nm1550 20 nm1625 10 nm40 dB37 dB40 dB1038 dB0.7 m2m0.7 m0.7 m3m6m3m3mFTTA/access/metroShort/medium-haul qualificationWireless fronthaul and backhaulWater peak detection at 1383nmMA31310 20 nm1550 20 nm1625 10 nm1650 10/ 5 nm43 dB41 dB41 dB41 dB0.7 ulqualificationFTTH test up to 1x128 splitterMP21310 20 nm1550 20 nm1625 10 nm1650 10 nm46 dB45 dB44 dB42 dB0.65 m2.5 mFTTH/long-haul/very long-haulLong haul/very long haulqualificationFTTH test up to 1x256 splitter1. ST for QUAD/MM only2. Sames wavelengths as the OTDR port. Not available on live port.3. 2 to 50 dBm for Quad4. Available on MM and Quad modules5. Using a modal controller6. Laser at 25 C and measured at 10 μs2Network Type4100-Series OTDR Modules7. The one-way difference between the extrapolated backscattering level at the startof the fiber and the RMS noise level, after 3 minutes averaging8. Measured at 1.5 dB down from the peak of an unsaturated reflective event9. Measured at 0.5 dB from the linear regression using aFC/UPC-type reflectance10. Measured on optical fiber with Rayleigh parameter K(-82.01dB 0.17dB at 1546nm

Ordering InformationDescriptionDescriptionPart NumberPart NumberUniversal Optical Connectors (for MM and QUAD)OTDR ModulesMultimode 850/1300OTDR 50 nmOTDR moduleE4146QUADStraightEUNIPCFC, EUNIPCSC, EUNIPCST8 angledEUNIAPCFC, EUNIAPCSCUniversal Optical Connectors (for MA2, MA3 and MP2 modules)LA 1310/1550 nm OTDR moduleE4126LAMA2 1310/1550 nm OTDRmodule with straight connectorE4126MA2-PCMA2 1310/1383/1550 nm OTDRmodule with straight connectorE4138MA283-PCMA3 1310/1550 nm OTDRmodule with angled connectorE4126MA3-APCMP2 1310/1550/1625 nm OTDRmodule with straight connectorE4136MP2-PCStraightEUSCADS, EUFCADS, EULCADS8 angledEUSCADS-APC, EUFCADS, EULCADS-APCAdditional part numbers are available, please contact your VIAVI sales representative.For more information on T-BERD/MTS-2000, -4000 V2, -5800 and CellAdvisor 5G test platforms or individualmodules, refer to their respective data sheets and brochures.For more information about our SLM (Smart Link Mapper) OTDR applications, refer to this heet-en.pdfContact UsVIAVI Solutions 1 844 GO VIAVI( 1 844 468 4284)To reach the VIAVI office nearest you,visit viavisolutions.com/contact. 2019 VIAVI Solutions Inc.Product specifications and descriptions in thisdocument are subject to change without notice.otdr20004000-ds-fop-tm-ae30168330 910 0819viavisolutions.com

VIAVI SolutionsData SheetVIAVI T-BERD/MTS-2000Handheld Modular Test SetFiber Optic Multitest Tool for Smarter, Faster Field TestingCosts, workflow, quality, network performance, and customer experience arecritical for the success of today’s fiber optic networks. Selecting the righttest tools has become key toward meeting these needs. The VIAVI Solutions T-BERD /MTS-2000 is a handheld multi-test platform that provides fieldtechnicians with a single handheld unit to install, turn-up and maintainthese networks to the highest standards.Its innovative design and hands-free bag ensure that allessential fiber test tools are close at hand, whatever thejob or location. A large color screen with graphical userinterface drives simple operation and optimal workflowin the field.Test capabilities include a range of OTDR modules formultimode and single-mode testing, including CWDM& DWDM OTDR, as well as a range of FiberComplete modules for automated insertion loss/optical returnLoss (IL/ORL), OTDR and fault finding. Both OTDR andFiberComplete modules are passive optical network(PON) optimized. The unit is also ready for connectorend face pass/fail analysis to IEC standards with a digitalanalysis microscope.Key Benefitsyy Ensure the highest-quality connectorizing,splicing, and turn-up of new fiber linksyy Improve workflow with hands-free solution,driving best practices to IEC standardsyy Smarter and faster field testing with simplesetup and instantaneous pass/fail resultsyy Boost productivity with improved reportgeneration and flexible connectivityyy Decrease OpEx and increase fieldproductivity when combined withStrataSync & CerTiFiKey Featuresyy High-visibility touch-screen displayThe CWDM-OSA and DWDM-OCC modules alsoenable turn-up and troubleshooting of coarse or densewavelength division multiplexing (CWDM DWDM orHybrid) networks.yy Wide range of field installable OTDR modulesincluding QUAD and PONyy Optional built-in optical power meter, visualfault locator (VFL), and optical talk setyy Flexible connectivity with Ethernet, USB,Bluetooth , and WiFi capabilitiesyy Smart Access Anywhere (SAA) for remotecontrol & field tech supportyy StrataSync enabled — centralized cloudbased asset, configuration, test data andworkflow managementT-BERD/MTS-2000

Applicationsyy Fiber optic test, qualification, certificationand reportingyy Certify the fiber physical layer on FTTx/ PON,access, metro and enterprise networksyy FiberComplete automated uni & bidirectional IL, ORL, Length, OTDR certificationyy Automated fiber inspection and IEC pass/failanalysisWidest Range of Applications for Maximum FlexibilityThe T-BERD/MTS-2000 provides the largest range of test capabilities offered in one handheld unit. The modulardesign allows service providers the maximum flexibility to scale their investment and evolve with the growth oftheir network.The instrument supports the whole range of essential fiber analysis tools including connection inspection,connection check, source, ORL, OTDR, a power meter, and DWDM Optical Channel Checker (DWDM-OCC).Application modules used with the T-BERD/MTS-2000 can also be used with the T-BERD/MTS-4000 V2 and thetwo products are ultFinderExpertOTDRSourceDWDMOCCReportBoosted Productivity with Seamless Data WorkflowThe T-BERD/MTS-2000 integrates various communication capabilities allowing remote control, data and setupuploads/downloads, and report transfer. The unit has one high-speed 1G Ethernet port, three USB ports, andoptional WiFi and Bluetooth network connections.Upload filesRemote controlTransfer to PC,tablets, smartphones.Test andcreate report2 T-BERD /MTS-2000 Handheld Modular Test SetData and report storagePost-processingRemote coaching

T-BERD/MTS-2000 Design Optimizes Operational Efficiency123 4895671 5-inch touch screen12 Results page2 Charge indicator13 Loudspeaker3 On indicator14 Headset jack4 File menu15 AC/DC input5 Setup menu16 Slave mini USB port6 Start/Stop17 RJ45 connector7 Testing indicator18 Master USB ports (2)8 On/Off19 Power meter port9 Home page20 VFL or talk set port10 Cancel21 WiFi and Bluetooth options11 Direction and validation keys317141415163 T-BERD /MTS-2000 Handheld Modular Test Set1819 20

StrataSync — Empower Your AssetsStrataSync Core capabilities are included when you purchase any StrataSyncenabled instrument from VIAVI, there is nothing to buy to take advantage ofthese benefits. StrataSync Core includes asset and configuration management,test data management with 35 day limit, and even instrument self-managementfor techs via the Tech Portal. StrataSync Plus extends test data storage for up to6 years and provides access to seasoned VIAVI StrataSync experts for assistancewith setup, config, usage, reporting – just about anything that you desire.SpecificationsConnector typeGeneral (typical at 25 C)Universal push pull (UPP)Display5-inch TFT color touch screen (12.5 cm)Resolution 800 x 480 WVGABuilt-In Visual Fault Locator (VFL)InterfacesTwo USB 2.0 portsOne mini-USB 2.0 portRJ45 LAN 10/100/1000 MbpsBuilt-in Bluetooth (optional)Built-in WiFi 802.11 b/g/n (optional)Wavelength650 nmEmission modeCW, 1 HzLaser classClass 2 per standards EN60825-1 andFDA21 CFR Part 1040.10Built-In Talk SetInternal memory8 GB (1 GB for storage)Dynamic range32 dB (typical)BatteryRechargeable lithium-polymer battery9-hour operation as per TelcordiaGR-196-COREConnector typesSC, FC, and UPP (three adapters included)Power supplyAC/DC adapter, input 100-250 V AC, 50-60Hz; 2.5 A max, output 12 V DC, 25 WElectrical safety: EN60950-compliantSize with module(H x W x D)175 x 138 x 80 mm (6.9 x 5.4 x 3.2 in)DescriptionPart Number0.864 kg (1.89 lb)1.21 kg (2.67 lb)T-BERD/MTS-2000 Handheld ModularTest SetIncludes: touch screen, hands-free soft case,shoulder strap, power supply with 5 adaptableplugs (US, Europe, UK, Australia, Japan), on-lineGetting Started manualETB2000HVT/EM2000HVTBuilt-in optical power meter and VFL, with2.5 mm UPP connectorsE20PMVFLBuilt-in optical power meter with 2.5 mm UPPconnectorE20PMBuilt-in visual fault locator (VFL) with 2.5 mmUPP connectorE20VFLBuilt-in optical power meter and talk setE20TSPMInternal Bluetooth optionE20BLUEInternal WiFi optionE20WIFIUSB2.0 digital video scope kit (P5000i), including7 tips and soft caseEDFSCOPE5KiSoft carrying case for T-BERD/MTS-2000/4000E40SCASE1Hard carrying case for T-BERD/MTS-2000Modular Test SetE20HCASE12 V car adapter for T-BERD/MTS-2000/4000E40LIGHTERWeightwith batterywith battery and LMOTDROperating temperaturesNo options/modules–20 to 50 C (–4 to 122 F)With options/modules 0 to 40 C (32 to 104 F)Relative humidity0% to 95% noncondensingBuilt-In Power Meter1Calibrated wavelengths850/1310/1490/1550/1625/1650Wavelength range800 to 1650 nm in 1 nm stepsAccuracy 0.2 dBMeasurement range3 5 to 50 dBmMaximum resolution0.01 dB/0.01 nW21. At 25 C, after 20 minutes stabilization time and after zero setting.2. At calibrated wavelength (except 1650 nm)3. –45 dBm from 800 to 1250 nmContact UsVIAVI SolutionsOrdering Information 1 844 GO VIAVI( 1 844 468 4284)To reach the VIAVI office nearest you,visit viavisolutions.com/contact 2019 VIAVI Solutions Inc.Product specifications and descriptions in thisdocument are subject to change without notice.t-berd-mts-2000-ds-fop-tm-ae30168463 906 0319viavisolutions.com

VIAVI SolutionsData SheetVIAVISmartOTDR Handheld Fiber TesterThe affordable, easy-to-use handheld tester for techs at any levelThe lightweight and compact SmartOTDR speeds andoptimizes field testing of metro and access networks—with a tailored OTDR interface and automatic analysisthat any technician can understand.With SmartOTDR, generic or user-defined setupconfigurations eliminate setup errors and maintainresults consistency. One-touch operation and a singleresults window ensure fast and easy measurements,while robust wireless connectivity options increaseproductivity anywhere.Benefitsy Combines all essential fiber tests in onehandheld with visual fault locator (VFL),optical power meter (OPM), and P5000imicroscope optionsy Simplifies OTDR analysis with Smart LinkMapper (SLM) result viewy Upgrades easily in the fieldy Automates testing with objective,pass/fail resultsy Enhances productivity anywhere withpowerful network connectivity options)Featuresy Single-/dual-/tri-wavelength versions with1310/1550 nm and in-service 1625 or 1650nm wavelengthsy Light, compact, hands-free design includes5” high-visibility outdoor touch screeny Integrated CW light sourcey PON optimized to test through1x128 splitter ratio with FTTH-SLMy Built-in PON/XG-PON power meter(1490/1550/1578 nm)MicroscopeVFLPowermeterSmartTESTOTDRy Automated fiber inspection and macrobenddetection with pass/fail analysis softwarey 3G/4G connectivity via USB, Bluetooth /WiFioptionsSourcePONPowermeterExpertOTDRy 3-year warrantyy All-day battery life

Powerful ConnectivityUpload filesRemote controlSeveral connectivity options (3G/4G smartphones via USB andoptional Bluetooth/WiFi) enable remote control as well as dataand work-order transfers to-and-from tablets, smartphones,and computers. The SmartOTDR quickly resolves field issues inreal time, and optional SmartAccess Anywhere (SAA) can openTransfer to PC,tablets, smartphones.a tunnel in the cloud so a technician can remotely access andoperate the instrument. Compatible with a wide range of cloudservers (WebDAV service providers), the SmartOTDR can alsoTest andcreate reportData and report storagePost-processingRemote coachinginstantly share measurement reports using onboard FastReportConnectivity features and options enhance workflows.pdf report generation.SmartOTDR includes a one-year trial of cloud-based StrataSync for asset, configuration, and test-data management, and toensure that all instruments have the latest software andoptions installed.11416171819153456722089101112131.5-inch high-visibility capacitive touch screen11. Direction and validation keys2.Charge indicator12. Results page3.On indicator13. Loudspeaker4.File menu14. AC/DC input5.Setup menu15. Slave mini USB port6.Start/Stop16. Visual fault locator (VFL)7.Testing indicator17. Master USB ports8.On/Off18. OTDR port/continuous light source/power meter9.Home page19. OTDR live port (in-service test)/PON/XG-PON power meter10. Cancel (switch off functions)2 SmartOTDR 100A/B Series20. WiFi or Bluetooth options

Specifications (typical at 25 C)GeneralDisplay5-inch capacitive color touch screen (12.5 cm)Display resolution800 x 480 W VGAInterfaces2x USB 2.0 ports, 1x mini-USB 2.0 port, built-in Bluetooth and WiFi (optional, dongles also available)Storage10,000 OTDR traces typicalBatteryRechargeable Lithium-polymer battery, up to 20 hours of operation1Power supplyAC/DC adapter, input 100-250 V AC, 50-60 Hz; 2.5 A max, output 12 V DC, 25 WElectrical safetyEN60950 compliantSize (HxWxD)175 x 138 x 57 mm (6.9 x 5.4 x 2.24 in)Weight (battery included)Approx. 0.9 kg (1.98 lb)Operating/storage temperatureOperating: –20 to 50 C; storage: –20 to 60 CHumidity (noncondensing)95%OTDRLaser safety class (21 CFR)Class 1Number of data pointsUp to 256,000 data pointsDisplay range0.1 km to 260 kmSampling resolution4 cmDistance accuracy( 1 m) (sampling resolution) (1.10–5 x distance), excluding group index uncertaintiesAttenuation resolution0.001 dBAttenuation linearity 0.04 dB/dBSmartOTDR 100ASmartOTDR 100BCentral wavelength21310/1550/1650 nm 20 nm1310/1550/1625/1650 nm 20 nmRMS dynamic range337/35/32 dB40/40/41/41 dBPulse widths5 ns to 20 µs3 ns to 20 μsEvent dead zone1.35 m0.9 mAttenuation dead zone54m2.5 mSplitter attenuation dead zoneNot available45 m after 15 dB splitter loss4CW Light SourceOutput power level6–3.5 dBmStability long term (8 hr)7 0.05 dBBuilt-in Power Meter (optional)Operating mode270, 330, 1 kHz, 2 kHz, and TWINTestPower level range0 to –55 dBmCalibrated wavelengths1310, 1490, 1550, 1625, and 1650 nmMeasurement accuracy8 0.5 dBBuilt-in Visual Fault Locator (optional)Wavelength650 nmEmission modeCW, 1 HzLaser classClass 2 per EN60825-1 and FDA21 CFR Part 1040.10 standardsBuilt-in PON/XG-PON Power Meter (E118FA65PPM version)Wavelengths1490/1550 nm; 1490/1578 nmMeasurement ranges1490 nm: –35 to 5 dB m ; 1 550/1578 nm: –35 to 23 dBmMeasurement accuracy 0.5 dB1. Per Telcordia GR-196-CORE.2. Laser at 25 C and measured at 10 µs.3. The one-way difference between the extrapolated backscattering level at the start of the fiber and the RMS (SNR 1) noise level, after 3 minutes of averaging using the largest pulsewidth.4. Measured at 1.5 dB below the peak of an unsaturated reflective event using the shortest pulse width.5. Measured at 0.5 dB from the linear regression using a FC/UPC-type reflectance and the shortest pulse width.6. 1 dB.7. After light source stabilization, warm-up time of 20 min.8. At calibrated wavelengths and at –30 dBm.3 SmartOTDR 100A/B Series

Ordering InformationSmartOTDR ConfigurationsPart NumberAll configurations include a hands-free soft case with neck strap, a stylus for capacitive touch screen, a Lithium-Polymer batteryandSC/PC or SC/APC connector(s).SmartOTDR 1550nm A-range handheld testerE100A-PC/-APCSmartOTDR filtered 1650 nm A-range handheld testerE118FA65-APCSmartOTDR filtered 1650 nm A-range handheld tester with broadband and PON-XGPON (1490/1550/1578 nm)power metersE118FA65PPM-APCSmartOTDR 1310/1550 nm A-range handheld testerE126A-PC/-APCSmartOTDR 1310/1550/filtered 1650 nm A-range handheld testerE138FA65-PC/-APCSmartOTDR 1310/1550 nm B-range handheld testerE126B-PC/-APCSmartOTDR 1310/1550/filtered 1625nm B-range handheld testerE136FB-PC/-APCSmartOTDR 1310/1550/filtered 1650 nm B-range handhel

The VIAVI Solutions T-BERD /MTS-2000 is a handheld multi-test platform that provides field technicians with a single handheld unit to install, turn-up and maintain

Related Documents:

VIAVI Solutions Data Sheet VIAVI Trilithic DSP Series Meters Value-based models for every technician work group The DSP Series Meters As cable networks migrate to newer technologies, and anticipating an eventual move to DOCSIS 3.1 and 1.2 GHz downstream range for all meters, the complete VIAVI meter line provides these installation and service

VIAVI Solutions Data Sheet VIAVI OLP-82/82P SmartClass fiber power meter and microscope The new OLP-82 from VIAVI Solutions is the first handheld tool to combine pass/fail fiber inspection and optical power measurement (OPM) into one solution. As part of the new VIAVI SmartClass Fiber family, the OLP-82 helps service providers guarantee a .

VIAVI Solutions Data Sheet VIAVI OneExpert DSL (ONX-580) For xDSL, G.fast and FTTH Fast, consistent, and complete! Key Benefits and Features y Modular platform scales for new WiFi, fiber, and xDSL technology including VDSL Profile 35b and G.fast y OneCheck automates field tests and simplifies Copper and DSL results to consistently close jobs .

VIAVI Solutions Inc. Subject: The VIAVI OLS-3x series consists of small and rugged optical light sources for quick, easy, and convenient field insertion loss measurement and continuity checks. Created Date: 4/2/2020 3:17:10 PM

Significant Strategic Benefits to VIAVI Significantly strengthened VIAVI’s position in emerging 5G wireless Increased scale and presence with Tier 1 NEMs and Service Providers Market leadership position in military, public safety and avionics test markets Strong profitability and free cash flow leveraging VIAVI’s NOLs

VIAVI Solutions Data Sheet VIAVI Optimeter A simple to use, intelligent optical fiber meter to certify and troubleshoot fiber links The Optimeter is the ideal fiber test tool for novice or entry-level technicians in charge of fiber premises installation and repair. Benefits y Ramp-up new fiber techs faster y Deliver repeatable test procedure for

VIAVI Solutions Data Sheet VIAVI OneExpert ONX-580 For xDSL, G.fast and FTTH Fast, consistent, and complete! Key Benefits and Features y Modular platform scales for new WiFi, fiber, and xDSL technology including VDSL Profile 35b and G.fast y OneCheck automates field tests and simplifies Copper and DSL results to consistently close jobs correctly

American National Standards Institute (ANSI) A300 (Part 6) – 2012 Transplanting for Tree Care Operations – Tree, Shrub, and other Woody Plant Maintenance Standard Practices (Transplanting) Drip line The hole should be 1.5-2 times the width of the root ball. EX: a 32” root ball should have a minimum wide 48” hole