fineDoc Number:Last Revision Date:Created by:Template Ver. Number:CAEUCS 1.4.1F Port Channel andTrunkEDCS- XXXXX January 24, 2011Dave McFarlandEDCS-781852 Rev 3

TABLE OF CONTENTS. 1. 1. 11INTRODUCTION/CAVEATS . 41.1 What Cisco Provides . 41.2 What the Field Site Must Provide . 41.3 Topology Used for this White Paper . 51.4 MDS configuration . 51.5 UCS f-port channel, trunk configuration . 61.5.1 Select fc port and set as uplink ports. Set the VSAN for those ports. Repeat forall ports that will be members of the port-channel . 61.5.2 Set the port native VSAN . 71.5.3 Configure the port-channel . 81.5.4 Port Channel Name. 91.5.5 If you have VSANs in the reserved range, you will see this error . 91.5.6 Port Channel Name. 91.5.7 Add the fc uplink port(s) into the port-channel . 91.5.8 Set the same native VSAN as what the f ports are in and enable the portchannel. 111.5.9 Check fc uplink status on UCS . 121.5.10In non-trunk mode. 121.5.11On the MDS side, ports fc 1/1 and fc 1/2 are the uplink ports to the UCSswitch 131.5.12In non-trunk mode, only VSAN 100 in this example is being transported . 131.5.13CLI configuration . 131.6 Trunk Mode . 141.6.1 Starting with the UCS f-ports in VSAN 1, the MDS connection ports in VSAN 1and no port-channels. 141.6.2 Enable Trunk mode . 161.6.3 Create the port-channel in UCS . 181.6.4 Check the port-channel trunk on the MDS . 201.6.4 CHECK THE PORT-CHANNEL AND TRUNK ON THE UCS SIDE . 211.7 Additional Checks. 211.7.1 Check UCS port transitions in the fault logs . 211.7.2 Verify switch WWN on UCS to MDS flogi database logins for the port-channel221.7.3 Verify UCS fc port and san-port-channel configuration. 231.7.4 Verify MDS fc port and port-channel configuration . 231.7.5 On UCS show npv and VSAN status . 251.7.6 On MDS show flogi status . 25

1Introduction/CaveatsThis white paper will guide the user through the configuration and verification of the f-portchannel and trunking.Make sure the sfp speed on all ports are identical. There is no provision to set the speed of portson the UCS FC module. If you attempt to create a port-channel with a 2G NPV and 4G NPV itwill fail. With additional configuration on the MDS side (not shown here) mixed speed sfps canbe made to work. But, it’s far simpler to just keep them all the same.In NX-OS 4.X and greater introduced a new range of reserved VSANs. These are in the range of3840 and 4078. Existing MDS and UCS users may have already configured these VSANs. Youwill receive a warning that any of those VSANs will be disabled if you proceed. On the UCSside, if you attempt to configure f port-channels, those f ports carrying any reserved VSAN willdisable.In UCS, trunk mode is disabled by default. It is enabled on a switch basis, not port.This document does not describe every possible variation of performing these configurations,but, will guide you to a good working setup.Supported MDS models. The MDS NX-OS version is per the current UCS interop guide. The fport-channel and trunk support was introduced with MDS NX-OS 4.2MDS 9509/9513 Gen-2,w/Gen-2 Line Card, 9222i,91489124, 9134MDS 9509/9506/9216 anyGen-1UCS f san-port-channelMDS NX-OS 5.0(4) andaboveUCS f port-trunkMDS NX-OS 5.0(4) andaboveMDS NX-SO 5.0(4) andaboveNot supportedNot supported1.1 What Cisco Provides SoftwareUCS 1.4.1 Image1.2 What the Field Site Must Provide Hardware Requirementso UCS SystemNot supported

o MDS SAN switch1.3 Topology Used for this White Paper1.4 MDS configurationConfigure MDS ports to connect to UCS portsMDS global configurationcae-sj-9506-1(config)# feature npivcae-sj-9506-1(config)# feature fport-channel-trunkcae-sj-9506-1(config)# trunk protocolMDS Channel-group configurationcae-sj-9506-1(config-if)# show running-config interface fc 1/1-2!Command: show running-config interface fc1/1-2!Time: Fri Dec 10 10:23:51 2010version 4.2(7b)

interface fc1/1switchport rate-mode dedicatedswitchport mode autoswitchport trunk mode offchannel-group 43 forceno shutdowninterface fc1/2switchport rate-mode dedicatedswitchport mode autoswitchport trunk mode offchannel-group 43 forceno shutdowncae-sj-9506-1(config-if)# show running-config interface port-channel 43!Command: show running-config interface port-channel 43!Time: Fri Dec 10 10:24:00 2010version 4.2(7b)interface port-channel 43channel mode activeswitchport rate-mode dedicatedswitchport trunk mode offno shutdown1.5 UCS f-port channel, trunk configurationConfigure UCS fibre module and san port channel1.5.1 Select fc port and set as uplink ports. Set the VSAN for those ports. Repeat for allports that will be members of the port-channel

1.5.2 Set the port native VSANscope fabric aenter interface 2 3enableset user-label ""exitenter interface 2 4enableset user-label ""exitenter interface 2 5enableset user-label ""exitenter interface 2 6enableset user-label ""exitenter interface 2 7enableset user-label ""exit

enter interface 2 8enableset user-label ""exitenter port-channel 1enableenter member-port 2 1enableexitenter member-port 2 2enableexitset adminspeed autoset name ""exitenter vsan 100 100 100set default-zoning disabledset fcoe-vlan 100set id 100enter member-port-channel a 1exitexitset uplink-trunking disabledexit1.5.3 Configure the port-channel

1.5.4 Port Channel Name1.5.5 If you have VSANs in the reserved range, you will see this error1.5.6 Port Channel Name1.5.7 Add the fc uplink port(s) into the port-channel

1.5.8 Set the same native VSAN as what the f ports are in and enable the port-channelIt will take a few minutes for the port-channel negotiation to complete and go from “admindown” to “admin-up”

1.5.9 Check fc uplink status on UCScae-sj-ca1-A(nxos)# show interface ---------------------------------Interface Vsan Admin Admin StatusSFP Oper Oper PortMode TrunkMode Speed 100 NP off upswl NP4 1fc2/2100 NP off upswl NP4 1fc2/31NP off sfpAbsent-- -------------------------------InterfaceVsan Admin StatusOper OperIPTrunkMode san-port-channel 1100offupNP8--1.5.10 In non-trunk modeVSAN 100 in this example is being transportedcae-sj-ca1-A(nxos)# show interface san-port-channel 1san-port-channel 1 is upHardware is Fibre ChannelPort WWN is 24:01:00:0d:ec:b1:33:00Admin port mode is NP, trunk mode is offsnmp link state traps are enabledPort mode is NPPort vsan is 100Speed is 8 Gbps5 minute input rate 160 bits/sec, 20 bytes/sec, 0 frames/sec

5 minute output rate 128 bits/sec, 16 bytes/sec, 0 frames/sec105267 frames input, 185749652 bytes74 discards, 0 errors0 CRC, 0 unknown class0 too long, 0 too short14571 frames output, 879244 bytes1 discards, 0 errors3158 input OLS, 18 LRR, 4 NOS, 0 loop inits349 output OLS, 46 LRR, 3053 NOS, 0 loop initsMember[1] : fc2/1Member[2] : fc2/2Interface last changed at Fri Dec 10 18:43:51 20101.5.11 On the MDS side, ports fc 1/1 and fc 1/2 are the uplink ports to the UCS switchcae-sj-9506-1(config-if)# sho interface ------------------------------Interface VsanAdmin AdminStatusSFPOper OperPortModeTrunkMode Speed ---------------------InterfaceVsan Admin StatusOper OperIPTrunkMode port-channel 43100offupF8--1.5.12 In non-trunk mode, only VSAN 100 in this example is being transportedcae-sj-9506-1(config)# show interface port-channel 43port-channel 43 is upHardware is Fibre ChannelPort WWN is 24:2b:00:0d:ec:24:5b:c0Admin port mode is auto, trunk mode is offsnmp link state traps are enabledPort mode is FPort vsan is 100Speed is 8 Gbps5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec35293 frames input, 9085960 bytes0 discards, 0 errors0 CRC, 0 unknown class0 too long, 0 too short224617 frames output, 394210440 bytes0 discards, 0 errors732 input OLS, 411 LRR, 304 NOS, 0 loop inits476 output OLS, 62 LRR, 567 NOS, 99 loop initsMember[1] : fc1/1Member[2] : fc1/21.5.13 CLI configurationcae-sj-ca1-A# scope fc-uplinkcae-sj-ca1-A /fc-uplink # scope fabric acae-sj-ca1-A /fc-uplink/fabric # enter port-channel 11cae-sj-ca1-A /fc-uplink/fabric/port-channel* # enablecae-sj-ca1-A /fc-uplink/fabric/port-channel* # enter member-port 2 1cae-sj-ca1-A /fc-uplink/fabric/port-channel/member-port* # enablecae-sj-ca1-A /fc-uplink/fabric/port-channel/member-port* # exit

cae-sj-ca1-A /fc-uplink/fabric/port-channel* # enter member-port 2 2cae-sj-ca1-A /fc-uplink/fabric/port-channel/member-port* # enablecae-sj-ca1-A /fc-uplink/fabric/port-channel/member-port* # exitcae-sj-ca1-A /fc-uplink/fabric/port-channel* # set adminspeed1gbps 1 Gbps2gbps 2 Gbps4gbps 4 Gbps8gbps 8 GbpsautoAutocae-sj-ca1-A /fc-uplink/fabric/port-channel* # set adminspeed autocae-sj-ca1-A /fc-uplink/fabric/port-channel* # exitcae-sj-ca1-A /fc-uplink/fabric* # enter vsan 100 100 100cae-sj-ca1-A /fc-uplink/fabric/vsan* # enter mmember-portmember-port-channel mon-srccae-sj-ca1-A /fc-uplink/fabric/vsan* # enter memmember-portmember-port-channelcae-sj-ca1-A /fc-uplink/fabric/vsan* # enter member-port-channel a 11cae-sj-ca1-A /fc-uplink/fabric/vsan/member-port-channel* # exitcae-sj-ca1-A /fc-uplink/fabric/vsan* # commit-bufferInterface last changed at Fri Dec 10 10:44:380:00:00:25:b5:10:10:0f1.6 Trunk ModeThis is a switch setting. All FC interfaces will be affected. Any uplinks, F port, TF port will betrunk on.Recommend first getting the individual links configured in VSAN 1. Make sure you haveconnectivity between the UCS and MDS before proceeding.VSAN 1 cannot be destroyed, so, you never have to worry about the native VSAN for a portdisappearing.1.6.1Starting with the UCS f-ports in VSAN 1, the MDS connection ports in VSAN 1 andno port-channels.1) Delete the port-channel from the previous exercise on the UCScae-sj-ca1-A /fc-uplink/fabric # delete port-channel 11cae-sj-ca1-A /fc-uplink/fabric* # commit-buffer2) Delete the port-channel from the MDScae-sj-9506-1(config-if)# interface port-channel 43cae-sj-9506-1(config-if)# shutcae-sj-9506-1(config-if)# interface fc 1/1-2cae-sj-9506-1(config-if)# no channel-group 43fc1/1 fc1/2 removed from port-channel 43 and disabled

shut/no-shut (disable/enable) the fc interfaces on the MDS and FI.cae-sj-ca1-A /fc-uplink # scope fabric acae-sj-ca1-A /fc-uplink/fabric # enter interface 2 2cae-sj-ca1-A /fc-uplink/fabric/interface # disablecae-sj-ca1-A /fc-uplink/fabric/interface* # commit-buffercae-sj-ca1-A /fc-uplink/fabric/interface # enablecae-sj-ca1-A /fc-uplink/fabric/interface* # commit-buffercae-sj-ca1-A /fc-uplink/fabric/interface #cae-sj-ca1-A /fc-uplink/fabric/interface # show interface detailInterfaces:Slot Id: 2Port Id: 2User Label:Admin State: EnabledOper State: UpState Reason:Oper Speed: 4 Gbps

cae-sj-9506-1(config-if)# sho interface offupswlF4--fc1/21autooffupswlF4--1.6.2 Enable Trunk modecae-sj-ca1-A /fc-uplink/fabric # set uplink-trunking enabledcae-sj-ca1-A /fc-uplink/fabric* # commit-buffercae-sj-ca1-A /fc-uplink/fabric # show detail expandFabric:Id: AUplink Trunking: EnabledCurrent Task:cae-sj-ca1-A(nxos)# show run interface fc 2/1-2!Command: show running-config interface fc2/1-2!Time: Fri Dec 10 21:07:55 2010version 4.2(1)N1(1.4)

interface fc2/1switchport trunk mode onno shutdowninterface fc2/2switchport trunk mode onno shutdowncae-sj-ca1-A(nxos)# sho interface fc 2/1fc2/1 is upHardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)Port WWN is 20:41:00:0d:ec:b1:33:00Admin port mode is NP, trunk mode is onsnmp link state traps are enabledPort mode is NPPort vsan is 1cae-sj-9506-1(config-if)# interface fc 1/1-2cae-sj-9506-1(config-if)# switchport trunkcae-sj-9506-1(config-if)# switchport trunk mode autocae-sj-9506-1(config-if)# shutcae-sj-9506-1(config-if)# no shutcae-sj-9506-1(config-if)# sho interface fc 1/2fc1/2 is trunkingHardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)Port WWN is 20:02:00:0d:ec:24:5b:c0Admin port mode is auto, trunk mode is autosnmp link state traps are enabledPort mode is TFPort vsan is 1Speed is 4 GbpsRate mode is dedicatedTransmit B2B Credit is 16Receive B2B Credit is 16Receive data field Size is 2112Beacon is turned offTrunk vsans (admin allowed and active) (1,10,50,100,103,1000)Trunk vsans (up)(1)Trunk vsans (isolated)(10,50,103,1000)Trunk vsans (initializing)(100)5 minutes input rate 160 bits/sec, 20 bytes/sec, 0 frames/sec5 minutes output rate 224 bits/sec, 28 bytes/sec, 0 frames/sec2109 frames input, 153484 bytes0 discards, 0 errors0 CRC, 0 unknown classcae-sj-ca1-A(nxos)# sho interface fc 2/1fc2/1 is trunkingHardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)Port WWN is 20:41:00:0d:ec:b1:33:00Admin port mode is NP, trunk mode is onsnmp link state traps are enabledPort mode is TNPPort vsan is 1Speed is 4 GbpsTransmit B2B Credit is 16Receive B2B Credit is 16Receive data field Size is 2112Beacon is turned off

Trunk vsans (admin allowed and active) (1,100)Trunk vsans (up)(1,100)Trunk vsans (isolated)()Trunk vsans (initializing)()5 minute input rate 224 bits/sec, 28 bytes/sec, 0 frames/sec5 minute output rate 152 bits/sec, 19 bytes/sec, 0 frames/sec105487 frames input, 185778292 bytes109 discards, 0 errors0 CRC, 0 unknown class0 too long, 0 too short14732 frames output, 896024 bytes3 discards, 0 errors4678 input OLS, 23 LRR, 4 NOS, 0 loop initscae-sj-9506-1(config-if)# show interface ---------------------------------Interface VsanAdmin AdminStatusSFPOper OperPortModeTrunkMode Speed F4-cae-sj-ca1-A(nxos)# sho interface ---------------------------------Interface VsanAdmin AdminStatusSFPOper OperPortModeTrunkMode Speed 6.3 Create the port-channel in UCS

cae-sj-9506-1(config)# interface port-channel 43cae-sj-9506-1(config-if)# switchport trunk mode autocae-sj-9506-1(config-if)# interface fc 1/1-2cae-sj-9506-1(config-if)# channel-group 43fc1/2 added to port-channel 43 and disabledplease do the same operation on the switch at the other end of the portchannel,then do "no shutdown" at both ends to bring it upcae-sj-9506-1(config-if)# shutcae-sj-9506-1(config-if)# no shut1.6.4 Check the port-channel trunk on the MDScae-sj-9506-1(config-if)# sho interface port-channel 43port-channel 43 is trunkingHardware is Fibre ChannelPort WWN is 24:2b:00:0d:ec:24:5b:c0Admin port mode is auto, trunk mode is autosnmp link state traps are enabledPort mode is TFPort vsan is 1Speed is 4 GbpsTrunk vsans (admin allowed and active) (1,10,50,100,103,1000)Trunk vsans (up)(1,100)Trunk vsans (isolated)(10,50,103,1000)Trunk vsans (initializing)()5 minutes input rate 184 bits/sec, 23 bytes/sec, 0 frames/sec5 minutes output rate 224 bits/sec, 28 bytes/sec, 0 frames/sec42 frames input, 4628 bytes0 discards, 0 errors0 CRC, 0 unknown class0 too long, 0 too short46 frames output, 5960 bytes0 discards, 0 errors1 input OLS, 1 LRR, 0 NOS, 0 loop inits

1.6.4 Check the port-channel and trunk on the UCS sidecae-sj-ca1-A(nxos)# show interface ---------------------------------Interface VsanAdmin AdminStatusSFPOper OperPortModeTrunkMode Speed ---------------------------InterfaceVsan Admin StatusOper OperIPTrunkMode san-port-channel 221ontrunkingTNP ------------------------------PortVRFStatus IP ca1-A(nxos)# show interface san-port-channel 22san-port-channel 22 is trunkingHardware is Fibre ChannelPort WWN is 24:16:00:0d:ec:b1:33:00Admin port mode is NP, trunk mode is onsnmp link state traps are enabledPort mode is TNPPort vsan is 1Speed is 4 GbpsTrunk vsans (admin allowed and active) (1,100)Trunk vsans (up)(1,100)Trunk vsans (isolated)()Trunk vsans (initializing)()5 minute input rate 264 bits/sec, 33 bytes/sec, 0 frames/sec5 minute output rate 216 bits/sec, 27 bytes/sec, 0 frames/sec105564 frames input, 185787576 bytes111 discards, 0 errors0 CRC, 0 unknown class0 too long, 0 too short14802 frames output, 903688 bytes3 discards, 0 errors4681 input OLS, 26 LRR, 4 NOS, 0 loop inits526 output OLS, 73 LRR, 4526 NOS, 0 loop initsMember[1] : fc2/1Member[2] : fc2/2Interface last changed at Fri Dec 10 21:15:33 20101.7 Additional Checks1.7.1 Check UCS port transitions in the fault logs

1.7.2 Verify switch WWN on UCS to MDS flogi database logins for the port-channelcae-sj-9506-1(config)# show flogi FCIDPORT NAMENODE ---------------------------------fc2/131000x640101 50:0a:09:81:86:78:3b:98 50:0a:09:80:86:78:3b:98fc4/9100x530013 50:0a:09:84:86:78:3b:98 50:0a:09:80:86:78:3b:98fc4/13100x530000 20:41:00:0d:ec:b1:33:00 20:0a:00:0d:ec:b1:33:01fc4/13100x530006 20:00:00:25:b5:77:00:1f 20:00:00:25:b5:99:00:0ffc4/13100x53000b 20:00:00:25:b5:77:00:3e 20:00:00:25:b5:99:00:1ffc4/14100x530002 20:42:00:0d:ec:b1:33:00 20:1e:00:0d:ec:b1:33:01port-channel 110x620213 24:01:00:0d:ec:50:0a:80 20:01:00:0d:ec:50:0a:81

port-channel 2port-channel 211000x6202150x64010624:01:00:0d:ec:d3:5d:c0 20:01:00:0d:ec:d3:5d:c120:00:00:25:b5:00:10:0e 20:00:00:25:b5:10:10:0f1.7.3 Verify UCS fc port and san-port-channel configurationcae-sj-ca3-A(nxos)# show run interface fc 2/3-4!Command: show running-config interface fc2/3-4!Time: Wed Aug 18 21:08:53 2010version 4.2(1)N1(1.4)interface fc2/3switchport trunk mode onchannel-group 1 forceno shutdowninterface fc2/4switchport trunk mode onchannel-group 1 forceno shutdowncae-sj-ca3-A(nxos)# show run interface san-port-channel 1!Command: show running-config interface san-port-channel 1!Time: Wed Aug 18 21:09:31 2010version 4.2(1)N1(1.4)interface san-port-channel 1channel mode activeswitchport mode NPswitchport trunk mode onno shutdown1.7.4 Verify MDS fc port and port-channel configurationcae-sj-9506-1(config)# show run interface fc 1/1-2!Command: show running-config interface fc1/1-2!Time: Wed Aug 18 14:09:45 2010version 5.0(1a)interface fc1/1switchport rate-mode sharedswitchport mode Fswitchport trunk mode autochannel-group 2 forceno shutdowninterface fc1/2switchport rate-mode sharedswitchport mode Fswitchport trunk mode autochannel-group 2 forceno shutdowncae-sj-9506-1(config)# show run interface port-channel 2!Command: show running-config interface port-channel 2!Time: Wed Aug 18 14:09:52 2010version 5.0(1a)

interface port-channel 2channel mode activeswitchport mode Fswitchport rate-mode sharedswitchport trunk mode autocae-sj-ca3-A(nxos)# show interface san-port-channel 1san-port-channel 1 is trunkingHardware is Fibre ChannelPort WWN is 24:01:00:0d:ec:d3:5d:c0Admin port mode is NP, trunk mode is onsnmp link state traps are enabledPort mode is TNPPort vsan is 1Speed is 8 GbpsTrunk vsans (admin allowed and active) (1,10,50,100,103)Trunk vsans (up)(1,100)Trunk vsans (isolated)()Trunk vsans (initializing)(10,50,103)5 minute input rate 8 bits/sec, 1 bytes/sec, 0 frames/sec5 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec102 frames input, 15644 bytes6 discards, 0 errors0 CRC, 0 unknown class0 too long, 0 too short90 frames output, 10884 bytes0 discards, 0 errors0 input OLS, 0 LRR, 0 NOS, 0 loop inits10 output OLS, 6 LRR, 0 NOS, 0 loop initsMember[1] : fc2/3Member[2] : fc2/4Interface last changed at Wed Aug 18 20:26:04 2010cae-sj-9506-1(config)# show interface port-channel 2port-channel 2 is trunkingHardware is Fibre ChannelPort WWN is 24:02:00:0d:ec:24:5b:c0Admin port mode is F, trunk mode is autosnmp link state traps are enabledPort mode is TFPort vsan is 1Speed is 8 GbpsTrunk vsans (admin allowed and active) (1,10,50,100,103)Trunk vsans (up)(1,100)Trunk vsans (isolated)()Trunk vsans (initializing)(10,50,103)5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec5 minutes output rate 8 bits/sec, 1 bytes/sec, 0 frames/sec287 frames input, 30216 bytes0 discards, 0 errors0 CRC, 0 unknown class0 too long, 0 too short292 frames output, 91220 bytes0 discards, 0 errors44 input OLS, 26 LRR, 31 NOS, 0 loop inits20 output OLS, 0 LRR, 35 NOS, 0 loop initsMember[1] : fc1/1Member[2] : fc1/2Interface last changed at Wed Aug 18 13:25:58 2010cae-sj-9506-1(config-if)# sho interface port-channel 2port-channel 2 is trunkingHardware is Fibre ChannelPort WWN is 24:02:00:0d:ec:24:5b:c0Admin port mode is F, trunk mode is autosnmp link state traps are enabled

Port mode is TFPort vsan is 1Speed is 8 GbpsTrunk vsans (admin allowed and active) (1,10,50,100,103)Trunk vsans (up)(1)Trunk vsans (isolated)()Trunk vsans (initializing)(10,50,100,103)5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec59 frames input, 9484 bytes0 discards, 0 errors0 CRC, 0 unknown class0 too long, 0 too short52 frames output, 10108 bytes0 discards, 0 errors24 input OLS, 16 LRR, 13 NOS, 0 loop inits12 output OLS, 0 LRR, 17 NOS, 0 loop initsMember[1] : fc1/1Member[2] : fc1/2Interface last changed at Tue Aug 17 16:28:10 20101.7.5 On UCS show npv and VSAN statuscae-sj-ca3-A(nxos)# show npv statusnpiv is enableddisruptive load balancing is disabledExternal Interfaces: Interface: fc2/1, State: Pre-InitializedInterface: fc2/2, State: Pre-InitializedInterface: fc2/5, State: DownInterface: fc2/6, State: DownInterface: san-port-channel 1, State: TrunkingVSAN:1, State: Up, FCID: 0x620215VSAN:10, State: UpVSAN: 100, State: UpVSAN: 103, State: UpVSAN:50, State: UpNumber of External Interfaces: 5Server Interfaces: Interface: vfc686, VSAN:100, State: UpNumber of Server Interfaces: 11.7.6 On MDS show flogi statuscae-sj-9506-1(config)# show flogi FCIDPORT NAMENODE ---------------------------------fc2/131000x640101 50:0a:09:81:86:78:3b:98 50:0a:09:80:86:78:3b:98fc4/9100x530013 50:0a:09:84:86:78:3b:98 50:0a:09:80:86:78:3b:98fc4/13100x530000 20:41:00:0d:ec:b1:33:00 20:0a:00:0d:ec:b1:33:01fc4/13100x530006 20:00:00:25:b5:77:00:1f 20:00:00:25:b5:99:00:0ffc4/13100x53000b 20:00:00:25:b5:77:00:3e 20:00:00:25:b5:99:00:1ffc4/14100x530002 20:42:00:0d:ec:b1:33:00 20:1e:00:0d:ec:b1:33:01port-channel 110x620213 24:01:00:0d:ec:50:0a:80 20:01:00:0d:ec:50:0a:81port-channel 210x620215 24:01:00:0d:ec:d3:5d:c0 20:01:00:0d:ec:d3:5d:c1port-channel 21000x640106 20:00:00:25:b5:00:10:0e 2

The MDS NX-OS version is per the current UCS interop guide. The f port-channel and trunk support was introduced with MDS NX-OS 4.2 UCS f san -port -channel UCS f port -trunk MDS 9509/9513 Gen -2, w/Gen -2 Line Card, 9222i, 9148 MDS NX -OS 5.0(4) and above MDS NX -OS 5.0 (4) and abov

Related Documents:

ACADEMIC CALENDAR – EVEN SEMESTER . BATCH 2016-21; 2017 – 22; 2018 . 13-Apr-21 TUE H Telugu New year 14-Apr-21 WED H Tamil New Year 15-Apr-21 THU W Online Class 33 CAE 1 CAE 1 16-Apr-21 FRI W Online Class 34 CAE 1 CAE 1 17-Apr-21 SAT W Online Class 35 CAE 1 CAE 1 18-Apr-21 SUN H 19-Apr-21 MON W Online Class 36 Online Class 21 CAE 1 CAE .

Cisco UCS 6454 provides the management and communication backbone for the Cisco UCS B-Series Blade Servers, UCS 5108 B-series server chassis, UCS Managed C-Series rack servers, and UCS S-Series storage servers. All severs attached to the Cisco UCS 6454 Fabric Interconnect bec

2.1. Cisco UCS 5108 Chassis 9 2.2. Cisco UCS Fabric Interconnects 9 2.3. Cisco UCS Fabric Extenders 10 2.4. Cisco UCS Blade Servers 11 2.5. Cisco UCS Rack Mount C-Series Servers 11 2.6. Virtual Interface Cards (VIC) and other Network Adapters 11 2.7. Cisco UCS Manager (UCSM) 12 2.8. Physical Scope of the TOE 13 2.9. Logical Scope of the TOE 15

Cisco UCS Leadership and Momentum 4 UCS revenue reached a 2B annualized run rate Data Center revenue was 515M growing 77% Y/Y Over 23,000 unique UCS customers which represents 89% Y/Y growth More than half of all Fortune 500 customers have invested in UCS Over 3,400 Channel Partners are actively selling UCS worldwide and over 1700 UCS specialized

Cisco UCS Fabric Interconnects (Read Only / Cut Through Interfaces) SNMP, Syslog, SMTP, SMASH CLP, CIM XML, Smart Call Home 20, 40, 48, and 96 portsCisco UCS I/O Modules and FEX's Cisco UCS Blade Server Chassis Cisco UCS Blade and Rack Servers (Cut through Interfaces to CIMC) Serial over LAN, KVM, IPMI Cisco UCS I/O Adapters Cisco UCS Manager

Integrated CAD/CAE/CAM SystemsIntegrated CAD/CAE/CAM Systems Professional CAD/CAE/CAM ToolsProfessional CAD/CAE/CAM Tools - Unigraphics NX (Electronic Data Systems Corp - EDS)-CATIA (Dassault Systems-IBM)- Pro/ENGINEER (PTC) - I-DEAS (EDS) Other CAD and Graphics Packages - AutoCAD Mechanical Desktop / Inventor

Cisco UCS C240 M4 1200 2 (1 main, 1 redundant) C14 Cisco UCS C260 M2 1200 2 (1 main, 1 redundant) C14 Cisco UCS C420 M3 1200 2 (1 main, 1 redundant) C14 Cisco UCS C460 M2 850 4 (2 main, 2 redundant) C14 Cisco UCS C460 M4 1400 4 (2 main, 2 redundant) C14

Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unified Computing System (Cisco UCS), Cisco UCS B-Series Blade Servers, Cisco UCS C-Series Rack Servers, Cisco UCS S-Series Storage Servers, Cisco UCS Manager, Cisco UCS