AIR CONDITIONER APFM Series - Documents Indexing

2y ago
11 Views
2 Downloads
322.45 KB
7 Pages
Last View : 16d ago
Last Download : 3m ago
Upload by : Madison Stoltz
Transcription

AIR CONDITIONERAPFM SeriesThree Phase UnitsAir ConditionerSPECIFICATIONSCONVERTIBLE SINGLE PACKAGE AIR CONDITIONER3 THRU 5 TON, THREE PHASE· Efficiency: APFM -- 10 SEER.· Combination heating and electric cooling, self-contained for year-round comfort. Systems install on rooftop or at ground level. Units are shipped complete in one carton; withonly the electric heat requiring mounting at time of installation.CONSTRUCTION· Triple--coated steel, consisting of a Polyester top coat, a urethane primer coat preceeded by an oxide pretreatment. One piece weather resistant top. Access panels for easyservice. Side by side supply and return. Heavy 16 gauge base with rails.· Coil Guard to protect condenser coil.ACCESS PANELS· Located to provide easy serviceability. The controls are behind the same exterior panel.CONVERTIBLE DISCHARGE· Units have side-by-side supply and return air openings for either horizontal or downflow applications. Simply relocate duct cover panels.COMPRESSOR· The high efficiency compressor has external rubber mounts to help minimize system noise and features an automatic reset current / temperature sensing overload protectionsystem. 3 and 4 ton use reciprocating compressors, 5 ton uses a scroll.COILS· Both the condenser and evaporator coils have aluminum fins and copper tubes to promote efficient heat transfer. The refrigerant circuit is sealed, tested, and fully charged atthe factory.EXTERNALLY-MOUNTED GAUGE PORTS· Provides easier servicing and allows for more accurate reading of operating conditions.EVAPORATOR BLOWER· All model sizes are equipped with multiple speed direct drive blower motors to provide proper air flow for both heating and cooling requirements.AIR FILTERS· Air filters are supplied with these units.Electric Heat· 10 to 20 kwTransformer· 65VA· Resettable circuit breaker.Economizer· Factory wired to accept economizer.WARRANTY· Standard five (1) year limited warranty on parts.· Five (5) year limited warranty on the compressor.Rated in accordancewith ARI Standard 210.International Comfort Products650 Heil--Quaker Ave.Lewisburg, Tennessee 37091513 31 1201 065/16/02Listed ByUnderwriters’Laboratories

UNIT SPECIFICATIONSCondenser DataElectrical DataVoltagePhase - HzHACRBreaker /Max. FuseAPFM36H000208--230--3--60APFM36L000Fan MotorCoilFanSizeDiameter(In.)NumberBlades /Pitch CFM(Max.)BELSAmpacityTotal FaceArea(Sq. Ft.)Fins PerIn. / RowsTubeDiameter(In.)HPFullLoadAmps30 amps.19.711.3820 / 13/81/31.920.33 / 2728007.8460--3--6015 amps.1011.3820 / 13/81/3.7420.33 / 2728007.8APFM48H000208--230--3--6035 amps.24.710.520 / 23/81/31.920.33 / 08--230--3--60460--3--6015 amps.45 amps.20 amps.10.430.613.710.514.914.920 / 220 / 220 / 23/83/83/81/31/31/3.741.9.7420.320.320.33 / 274 / 254 / 253000330033007.88.08.0MODEL *NUMBEREvaporator CoilCoilTotalFaceArea(Sq. eR-22 (Oz.)ShipWeight( Lbs. 2000Scroll8.759.6136380Fins PerIn. / RowsTubeDiam.(In.)BlowerH.P. / Type /SpeedsFullLoadAmpsType &SizeRPM(Max)CFMRated3.6714 / 33/81/3 / PSC / 33.1DD10--8A11003.6714 / 33/81/2 / PSC / 32.0DD10--8A1100APFM48H0005.3314 / 33/83/4 / PSC / 36.0DD11-11AAPFM48L0005.3314 / 33/81 / PSC / 32.1APFM60H0005.3314 / 43/81 / PSC / 4APFM60L0005.3314 / 43/81 / PSC / 3MODELNUMBERAir Filters -- 3 ton use 12 x 25 x 1 (2 ea), 4 & 5 ton use 14 x 25 x 1 (2 ea).PERFORMANCE DATA: ty 1BTUH38.00045,50058,000S/TRatio.75.79.75E.E.R. 0006629EvaporatorRatedAirflow (SCFM)125016002000Ext. Static 2Pressure DropWet.3.3.3Rated Capacity @ ARI standard conditions, 95 Amb, 80 DB/67 WB, 230 Volts. For applications at 208 volts deduct 1000 BTU.Includes a .08 drop for a filterFor reference onlyBlower Performance Data in Horizontal ConfigurationPAF/PHFAir Delivery in CFM at ESP (in. W.C.)MotorUNIT SIZE0.200.300.400.50SpeedHI16061534145913823 4023544 2402169MD HI23922313221921245 TONMD LO2253218821072009LO2178210820461946ARI Minimum StaticWithout Filterinches of lCapacity 005860058600ARI Minimum AllowableAirflow - 350 lower Performance is for Horizontal Configuration without Accessories.Air delivery against shown external static pressues taken with 230V to unit and dry coil. For wet coil subtract approximately 25 CFM. Add .08 staticfor internal fitlers.** Applied to the ACTUAL capacity ratingSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE2

ELECTRICAL DATA: ELECTRIC HEAT ACCESSORYHEATERMODELAAH10FBHAAUsed With3 -- 5 TonAAH10FBLAAAAH15FBHAA3 -- 5 TonAAH15FBLAAAAH20FBHAA3 -- 5 TonNominal 14765,53065,530Supply 20FBLAASupplyCircuit mps20.023.111.530.034.617.340.046.223.1Maximum OvercurrentProtective Device(Amps)303015404525606030Mininum 9*Temperature Rise F @ CFMHeaterModelAAH10Use With3 -- 5 TonAAH153 -- 5 TonAAH203 -- 5 TonSupply --3--60208--3--60KW Rating9.67.214.410.819.214.4Total 0.7EXPANDED PERFORMANCE DATA (COOLING) -- 3 TON (GROSS DATA)65AirflowIDB* 903.81* Entering Indoor Temperature -- Degrees F. Dry BulbOutdoor Ambient Temperature - Degrees F. Dry Bulb8595Entering Indoor Temperature - Degrees F. Wet Bulb6771 59 63 67 71 59 63 00.804.9737.80.764.9335.90.734.85Standard Rating3SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

EXPANDED PERFORMANCE DATA (COOLING) -- 4 TON (GROSS DATA)65AirflowIDB* 954.34Outdoor Ambient Temperature - Degrees F. Dry Bulb8595Entering Indoor Temperature - Degrees F. Wet Bulb6771 59 63 67 71 59 63 60.845.6345.20.805.5943.00.775.506771EXPANDED PERFORMANCE DATA (COOLING) -- 5 TON (GROSS DATA)65AirflowIDB* 905.72Outdoor Ambient Temperature - Degrees F. Dry Bulb8595Entering Indoor Temperature - Degrees F. Wet Bulb6771 59 63 67 71 59 63 63.80.686.43* Entering Indoor Temperature -- Degrees F. Dry BulbStandard RatingSPECIFICATIONS SUBJECT TO CHANGE WITHOUT 57.60.767.3854.80.737.26

ACCESSORIESROOF CURBS, TRANSITION AND DUCT KITSUsed on(Unit Size)3 Ton4 -- 5 Ton8” Curb14” Curb24” CurbACL01FB0A *AXB020CLA **ACL01FB0A *AXB020CLA **ACM01FB0A *AXB020CMA **ACM01FB0A *AXB020CMA **ACH01FB0A *AXB020CHA **ACH01FB0A *AXB020CHA **Square to RoundTransition KitACT01FB0AAXB020CTAACT11FB0AACT22FB0ARound Duct Size(Inches)16161818Concentric GrillFlush c GrillStep DownAXB020CSAAXB020CSAAXB030CSAAXB030CSAROOF CURB DIMENSIONS (AC SERIES)Model No.ABCDEFGHK (ACL)K (ACM)K 442--3/42081424CDEFGHK (CLA)K (CMA)K (CHA)ROOF CURB DIMENSIONS (AX SERIES)Model 9-3/41881424* Full Perimeter Curbs** AXB curbs are not full perimenter curbs. 3 ton units will have a 3 inch overhang on the control access panel end of the unit . There will be some supply air blockage but , this doesnot affect the performance of the unit.ECONOMIZERSDescriptionMainlineModel NumberUsed onFully Modulating HorizontalAHE01FB0A3 TonFully Modulating HorizontalAHE02FB0A4 to 5 TonFully Modulating DownflowAEM01FB0A3 TonFully Modulating DownflowAEM03FB0A4 Ton3 Position HorizontalAHP01FB0A3 Ton3 Position HorizontalAHP02FB0A4 to 5 Ton3 Position DownflowAEP01FB0A3 TonC E3 Position DownflowAEP03FB0A4 TonAHFRESH AIR DAMPERSDescriptionMainlineModel Number35% Manual Fresh Air Damper35% Manual Fresh Air Damper35% Motorized Fresh Air Damper35% Motorized Fresh Air DamperAFA01FB0AAFA02FB0AAFM01FB0AAFM02FB0ABACKF GUsed on3 Ton4 to 5 TonBDK*Curb Dimensions3 TonRoof Curbs available in 8’’, 14” and 24‘‘ Heights (K Dimensions)4 to 5 TonRETURN AIR FILTER KITDescriptionReturn Air Filter Kit *MainlineModel NumberAKF12FBOAUsed onALLFilters not included in kit, small chassis uses 12 x 25 x 1 (2 ea), large chassis uses 14 x 25 x 1 (2 ea)HAIL GUARDDescriptionHail GuardMainlineModel NumberAGH01FB0AAGH02FB0AUsed on3 Ton4 to 5 TonACCESSORIES: LOW AMBIENT CONTROLModel NumberALA12CU0AKit Number1085493Used onALLSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE5

UNIT DIMENSIONS3 TO 5 TONAll Dimensions In InchesSeeDetail46--1/2BASE PAN -- CHASSIS42--3/4**BASE RAILBASE RAIL2746--1/4**12--1/4Condensate 3/1662--3/163--3/4ABCDEFGHIJ3 TonUNIT SIZE29--1/247--1/247--1/239--1/2121412144--1/24 TO 5 Ton37--1/247--1/247--1/246--1/2191912124--1/2** Measured from inside to inside on base rails.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE6

MODEL NUMBER IDENTIFICATION GUIDEMODEL NUMBERAPFM24H000AIR CONDITIONERP Single PackageELECTRICAL CHARACTERISTICSH 208 / 230--3--60, L 460--3--60COOLING CAPACITY (NOMINAL BTUH) M used on 5 ton and below.F STANDARD SERIES36 3 ton48 4 Ton60 5 TonGUIDE SPECIFICATIONCABINETThe cabinet is made of triple--coated steel, consisting of a Polyester top coat, a urethane primercoat preceeded byan oxide pretreatment. One piece weatherresistanttop.The base rails are 16 gauge steel with fork lift slots and holes providedfor lifting shackles. The unit is designed with convertible airflow for eitherhorizontal or downflow applications with conversion accomplished by relocating two panels. Indoor blower compartment interior cabinet surfaces are insulated with a minimum 1/2’’ thick, flexible glass insulation,coated on the air side.COOLING SECTIONThe unit is factory charged and operationally ready upon delivery. Theunit refrigerant circuit has a high efficiency fully reciprocating compressor (5 ton has scroll compressor) with internal overload protection, andcopper tube / aluminum fin evaporator and condenser coils. The unit isdesigned for cooling operation to 40o F and will be capable of beingwired for field installed economizer type accessories.COILSThe evaporator and condenser coils are fabricated with aluminum finsmechanically bonded to copper tubing. Both coils are pressure testedprior to assembly into the unit and electronically leak tested after assembly into the unit.CONDENSER FANThe unit has a single direct-drive propeller-fan / motor assembly. Theassembly is mounted directly to a vertical-discharge grille that is easilyremoved for service. Motors are 1100 RPM with sleeve or ball bearingsand internal overload protection.EVAPORATOR BLOWERAll units have a direct-drive evaporator blower motor as a standard. Thedirect-drive evaporator blower motor has sleeve bearings and internaloverload protection.INSTALLATION CLEARANCESRECOMMENDEDFOR SERVICERIGGING DETAILSCORNER WEIGHTS (LBS)UNIT SIZE3 TON4 TON5 TONABCDOPERATINGWEIGHT FICATIONS SUBJECT TO CHANGE WITHOUT NOTICE7

650 Heil--Quaker Ave. Lewisburg, Tennessee 37091 Listed By Underwriters Laboratories Rated in accordance with ARI Standard 210. AIR CONDITIONER APFM Series Three Phase Units Air Conditioner SPECIFICATIONS CONVERTIBLE SINGLE PACKAGE AIR CONDITIONER 3 THRU5 TON

Related Documents:

system room air conditioner. We are sure you will nd your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of the air conditioner and its functions. To avoid the risks that are always present when you use an electrical

Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner. After installing, the consumer must operate the air conditioner correctly according to this manual,keep a suitable storage for maintenance and moving of the air conditioner in the future. There must be an air-break switch.

A Word From Haier America Product Registration Thank you for buying a dependable, energy saving and easy-to-operate Commercial Cool air conditioner. This manual contains useful information for you to maintain, operate, install and safely use your air conditioner. Your air conditioner cleans, cools and dehumidifies the air in

Thank you for choosing the Whynter SNO portable air conditioner. You have bought one of the best portable air conditioners available today. Follow the instructions given in this booklet to obtain the very best performance from your portable air conditioner and take full advantage of the many advance features that your portable air conditioner .

to this manual,keep a suitable storage for maintenance and moving of the air conditioner in the future. There must be an air-break switch. Check the connecting cables and pipes carefully, make sure they are correct and firm before connecting the power of the air conditioner. T 3.15A 250V T 20A 250V Properly ground the air conditioner into the .

with air conditioner air conditioner operator's manual caution before installing and using this air conditioner, it is important that this manual be read and understood thoroughly kooltronic, inc. 30 pennington-hopewell road pennington, nj 08534 609†466-3400 fax: 609†466-1114 trimline np47 series 7,000 & 10,000 btu/h 900-034-08 (2/19) (cdr .

1. Inspect the air conditioner and verify correct functionality before mounting the air conditioner. See HANDLING AND TESTING THE AIR CONDITIONER on page 3. 2. Determine if the unit is to be surface or recess mounted. Using the appropriate cutout dimensions, see MOUNTING CUTOUT DIMENSIONS on page 5 of this manual. Prepare the enclosure

9781860960147 Jazz Piano Grade 5: The CD 22.92 17.24 18.76 19.83 9781860960154 Jazz Piano from Scratch 55.00 41.36 45.02 47.58 9781860960161 Jazz Piano Aural Tests, Grades 1-3 18.15 13.65 14.86 15.70 9781860960505 Jazz Piano Aural Tests, Grades 4-5 15.29 11.50 12.52 13.23 Easier Piano Pieces (ABRSM)