Reinforced Concrete Cantilever Retaining Wall Analysis and Design (ACI 318-14)

Reinforced Concrete Cantilever Retaining Wall Analysis and Design (ACI 318-14)Reinforced concrete cantilever retaining walls consist of a relatively thin stem and a base slab. The stem may haveconstant thickness along the length or may be tapered based on economic and construction criteria. The base is dividedinto two parts, the heel and toe. The heel is the part of the base under the backfill. This system uses much less concretethan monolithic gravity walls, but require more design and careful construction. Cantilever retaining walls can beprecast in a factory or formed on site and considered economical up to about 25 ft in height. This design examplefocuses on the analysis and design of a tapered cantilever retaining wall including a comparison with model resultsfrom the engineering software programs spWall and spMats. The retaining wall is fixed to the reinforced concrete slabfoundation with a shear key for sliding resistance. The following figure and design data section will serve as input fordetailed analysis and design.Figure 1 – Cantilever Retaining Wall Dimensions

CodeBuilding Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14)ReferenceDesign of Concrete Structures, 15th Edition, 2016, Darwin et. al., McGraw-Hill Education, Example 16.8spWall Engineering Software Program Manual v5.01, StucturePoint LLC., 2016spMats Engineering Software Program Manual v8.50, StucturePoint LLC., 2016Design DataWall Stem MaterialsWall Foundation Materialsfc’ 4,500 psifc’ 4,500 psify 60,000 psify 60,000 psiγc 150 pcfγc 150 pcfWall Stem DimensionsWall Foundation DimensionsWidth 1 ft stripWidth 1 ft stripHeight 13.5 ftLength 9.75 ftThickness 8 in. topThickness 18 in. 16 in. bottomRetaining Wall LoadsThe following figure shows all the loads applied to the cantilever retaining wall where:W1 0.67 13.5 150 1360 lbW2 0.67 0.5 13.5 150 680 lbW3 9.75 1.5 150 2190 lbW4 1.33 1.25 150 250 lbW5 3.75 2 120 900 lbW6 0.67 0.5 13.5 120 540 lbW6 4.67 13.5 120 7570 lbVersion: May-28-2019

Figure 2 – Applied Loads and Soil Pressure at Critical SectionsVersion: May-28-2019

Contents1.Preliminary Design .12.Wall Stability Checks .32.1. Wall Overturning Check .32.2. Soil Bearing Pressure .32.3. Wall Sliding Check .43.Flexural Reinforcement Requirements .54.Cantilever Retaining Wall Analysis and Design – spWall Software .74.1. Cantilever Retaining Wall Model Input .84.2. Cantilever Retaining Wall Result Contours . 104.3. Cantilever Retaining Wall Cross-Sectional Forces . 124.4. Cantilever Retaining Wall Maximum Displacement . 164.5. Cantilever Retaining Wall Cross-Sectional Forces at Stem Base . 165.Cantilever Retaining Wall Foundation Analysis and Design – spMats Software . 175.1. Cantilever Retaining Wall Foundation Model Input . 175.2. Cantilever Retaining Wall Foundation Result Contours . 195.3. Cantilever Retaining Wall Foundation Required Reinforcement . 225.4. Soil Reactions / Pressure . 235.5. Cantilever Retaining Wall Foundation Model Statistics . 246.Cantilever Retaining Wall Analysis and Design Results Comparison & Conclusions . 25Version: May-28-2019

1.Preliminary DesignThe thickness of the footing is roughly estimated to calculate the required thickness of the stem at the criticalsection (stem bottom). With the bottom of the footing at 3.5 ft below grade and an estimated footing thickness of1.5 ft, the free height of the stem is 13.5 ft. using the information provided in Figures 1 and 2:P 0.5 0.333 120 13.5 13.5 2 3.33 5440 lb (at the stem bottom)y 13.52 3 13.5 3.33 5.25 ft3 13.5 2 3.33 M u Pu y 1.6 5440 5.25 45.7 ft-kipFigure 3 – Bearing Pressure, Overturning and Sliding LoadsThe preliminary dimensions are selected using design aids from the reference Appendix A. 0.005 0.85 1 f c'0.003 f y 0.003 0.005 0.005 0.85 0.825 Reference 1 (Table A.4)45000.003 0.019760000 0.003 0.0051

The reference recommends the use of a ratio of about 40% of the maximum (ρ 0.008) for economy and ease ofbar placement.Mu b d2d 430Reference 1 (Graph A.1b)45700 12 10.9 in.0.9 12 430Using cover of 2 in. for members exposed to weather or in contact with ground. ACI 318-14 (Table 20.6.1.3.1)And #8 bars (db 1 in.), the minimum required thickness of the stem at the base equals:minimum tstem,base d min cover db1 10.9 2 13.4 in.22Use tstem,base 16 in.For Shear Check (at distance d above the base):P 0.5 0.333 120 12.5 12.5 2 3.33 4800 lbVu 1.6 P 1.6 4800 7680 lb Vc 2 f c' b d 2ACI 318-14 (22.5.5.1) Vc 0.75 2 1 4500 12 13.52 16300 lb VuStem thickness of 16 in. is adequate to resist the factored shear force.The thickness of the foundation (base) is the same as or slightly larger than that at the bottom of the stem. Thus,the 18 in. selected earlier need not be revised. The stem thickness can be reduced by tapering one side only up to8 in. at the top since the bending moment decreases with increasing distance from the wall base to zero at the topof the wall.2

2.Wall Stability ChecksThe wall has two failure modes: 1) Wall parts may not be strong enough to resist the acting forces, 2) the wall asa rigid body may be displaced or overturned by the earth pressure acting on it. The latter will be discussed in thissection to ensure that the retaining wall is stable by checking stability against overturning, sliding, and allowablesoil bearing pressure.Note: two cases are being examined. Case 1 where surcharge load is applied to point a (see Figure 3), and Case 2where surcharge load is applied to point b.2.1. Wall Overturning CheckCase 1 governs for wall overturning since it generated the highest overturning with the least resistance.Weights and moments about the front edge of the wall are shown in the following table (See figure 2 and designdata section):Table 1 - Weights and Moments about the Front Edgecomponent WeightsW, kipsx, ftMr, 256.17Total13.4981.00P 0.5 0.333 120 15 15 2 3.33 6.49 kipsy 152 3 15 3.33 5.77 ft3 15 2 3.33 The overturning moment is equal to:M o P y 6492 5.77 37.46 ft-kipFactor of Safety against overturning:FOSoverturning 81.00 2.16 1.5 (o.k.)37.462.2. Soil Bearing PressureThe distance of the resultant force from the base slab front edge is:3

a 81.00 37.469.75 3.23 ft 3.25 ft13.493The resultant is barely outside the middle third of the foundation (it is assumed that the bearing pressure becomeszero exactly at the edge of the heel as shown in Figure 2). The maximum soil pressure at the toe is calculated asfollows:q1 2 Rv3 aq1 2 13.49 1000 2784 psf qallowable 8000 psf (o.k.)3 3.23Reference 1 (Figure 16.5c)q2 0Reference 1 (Figure 16.5c)The soil pressure values calculated for Case 1. The soil pressure values for Case 2 do not govern for overturningand sliding. However, values calculated from Case 2 are needed for foundation flexural design as follows:q1 4 l 6 a Rvl2Reference 1 (Figure 16.5a)q1 2710 psf qallowable 8000 psf (o.k.)q2 6 a 2 l Rvl2Reference 1 (Figure 16.5a)q2 492 psf qallowable 8000 psf (o.k.)2.3. Wall Sliding CheckCase 1 also governs for sliding since it produces the least pressure and corresponding friction resistance.The coefficient of friction that applies for the length along the heel and key is 0.5, while the coefficient of frictionfor the length in front of the key is equal to the internal soil friction, that is, tan 30 ᴼ 0.577. More informationabout selecting the friction coefficient can be found in the reference in chapter 16 section 4. (for case wheresurcharge load is applied to point a):Friction, toe:Ftoe 0.5 2784 1713 3.75 0.577 4.87 kipsFriction, heel and key:Fheel and key 0.5 1713 6 0.5 2.57 kips4

Passive earth pressure:Ppassive 0.5 3.0 120 4.75 1.5 1.90 kips2Note that the top 1.5 ft layer of soil is discounted in this check as unreliable.Total:Ftotal 4.87 2.57 1.90 9.34 kipsFactor of Safety against sliding:FOSsliding 9.34 1.44 1.5 (can be regarded as adequate)6.49Thus, the retaining wall with the selected geometry is externally stable.3.Flexural Reinforcement RequirementsThe required flexural reinforcement is traditionally calculated at three critical sections: at the stem base, the toeand heel at the face of the stem.Calculate the required reinforcement to resist the moment at the stem base:M u 45.7 kip-ftUse #8 bars with 2.0 in. concrete cover per ACI 318-14 (Table 20.6.1.3.1). The distance from extremecompression fiber to the centroid of longitudinal tension reinforcement, d, is calculated below:d 16 2 0.5 1 13.5 in.To determine the area of steel, assumptions have to be made whether the section is tension or compressioncontrolled, and regarding the distance between the resultant compression and tension forces along the beamsection (jd). In this example, tension-controlled section will be assumed so the reduction factor ϕ is equal to 0.9,and jd will be taken equal to 0.95d. The assumptions will be verified once the area of steel is finalized.jd 0.95 d 0.95 13.5 12.83 in.b 12 in.The required reinforcement at initial trial is calculated as follows:As Mu45.7 12, 000 0.79 in.2 f y jd 0.9 60, 000 12.83Recalculate ‘a’ for the actual As 0.79 in.2: a c a 1 As f y0.85 f 'c b 0.79 60, 000 1.04 in.0.85 4500 121.04 1.25 in.0.83 0.003 0.003 dt 0.003 13.5 0.003 0.0293 0.005c 1.25 t 5

Therefore, the assumption that section is tension-controlled is valid.As Mu45.7 12, 000 0.78 in.2 f y (d a / 2) 0.9 60, 000 (13.5 1.04 / 2)The minimum reinforcement shall not be less thanAs ,min 3 fc'fy b d 3 4,500 12 13.5 0.54 in.260, 000ACI 318-14 (9.6.1.2(a))And not less thanAs ,min 200200 b d 12 13.5 0.54 in.2fy60, 000ACI 318-14 (9.6.1.2(b)) As,min 0.54 in.2Maximum spacing allowed:Check the requirement for distribution of flexural reinforcement to control flexural cracking: 40000 40000 s 15 2.5cc 12 fs fs ACI 318-14 (Table 24.3.2)cc 2.0 in.Use f s 2f y 40, 000 psi3ACI 318-14 (24.3.2.1) 40, 000 s 15 2.5 2.0 10 in. (Governs) 40, 000 40, 000 s 12 12 in. 40, 000 Provide #8 bars at 9 in. on centers.Note that the stem bending moment decreases rapidly with increasing distance from the bottom. For this reason,only part of the main reinforcement is needed at higher elevations and alternate bars can be discontinued whereno longer needed. More information about cutting bars in the stem are provided in the reference. All the valuesin the following table are calculated based on the procedure outlined above for the stem.Table 2 – Reinforcing Design SummaryCritical SectionStem BaseToeHeelDesign Moment, Mu (ft-kips)45.724.329.9Effective depth, d (in.)13.514.514.52As,req (in. )0.780.380.4720.540.580.58#8 @ 9 in.#7 @ 12 in.#7 @ 12 in.As,min (in. )Reinforcement6

4.Cantilever Retaining Wall Analysis and Design – spWall SoftwarespWall is a program for the analysis and design of reinforced concrete shear walls, tilt-up walls, precast walls,retaining walls, tank walls and Insulated Concrete Form (ICF) walls. It uses a graphical interface that enables theuser to easily generate complex wall models. Graphical user interface is provided for: Wall geometry (including any number of openings and stiffeners) Material properties including cracking coefficients Wall loads (point, line, and area), Support conditions (including translational and rotational spring supports)spWall uses the Finite Element Method for the structural modeling, analysis, and design of slender and nonslender reinforced concrete walls subject to static loading conditions. The wall is idealized as a mesh ofrectangular plate elements and straight line stiffener elemen

Reinforced concrete cantilever retaining walls consist of a relatively thin stem and a base slab. The stem may have constant thickness along the length or may be tapered based on economic and construction criteria. The base is divided into two parts, the heel and toe. The heel is the part of the base under the backfill.

Related Documents:

The BPR typical plans present retaining wall dimensions for wall heights from 6 to 30 ft. The first type of retaining wall shown is the cantilever retaining wall on a spread footing. Also shown are pile-supported cantilever walls and counterfort walls. For our discussion we will refer only to the cantilever retaining walls on spread footings.

Fig 1. Design variables of a cantilever retaining wall model Cross-section and forces action on a typical cantilever retaining wall can be seen in Fig. 1. Fig 1. Cross section and forces acting on a cantilever retaining wal

Page 2Page 2 Retaining wall design and price guide 2022-2023 Retaining wall design and price guide 2022-2023 Page 3 Contents. Basic design principles. 5. Cantilever retaining walls. King post 6 L shape 10 Reinforced block 7014 Stepoc masonry 18. Gravity retaining walls. Concrete block 22 Masonry 26 Gabion basket 30 Inclined concrete block 34

Island Block & Paving Retaining Wall Software Q11050501-1 5/5/11 Page 3 PART 1 User Manual - Design Check to AS 4678 of: Segmental Concrete Reinforced Soils Segmental Concrete Gravity Retaining Walls Reinforced Concrete Masonry Cantilever Retaining Walls Scope This manual applies to the use of

c. Counter fort retaining wall. d. Buttress retaining wall. Cantilever retaining walls are constructed of reinforced concrete. They consist of a relatively thin stem and a base slab. The base is also divided into two parts, theheel and toe. The heel is the part of the base under the backfill. The toe is the other part of the base. The analysis .

example of geosynthetically reinforced concrete block retaining wall is shown in Figure 1. Figure 1. Example of CBR wall 1.1 Uses of concrete block retaining walls Concrete block retaining walls are reasonably versatile structures, and generally provide a more cost effective solution when compared to reinforced concrete walls or gabion structures.

125 Retaining walls Example 3.16 Design of a cantilever retaining wall (BS 8 110) The cantilever retaining wall shown below is backÞlled with granular material having a unit weight, ,

(a) Cantilever retaining (b) Counterfort retaining wall wall (c) Retaining wall with relieving platforms is typically triangular, least at the top of the wall and increasing towards the bottom. The earth pressure could push the wall forward or overturn it if not properly addressed. Also, the groundwa