Simplified Surgery. Personalized Performance. - Ortho.smith

2y ago
9 Views
3 Downloads
4.31 MB
12 Pages
Last View : 1y ago
Last Download : 3m ago
Upload by : Victor Nelms
Transcription

Simplified surgery.Personalized performance.

VISIONAIRE FastPak ContentsVISIONAIRE Cutting GuidesMetal AP Cutting BlockReam-through Femoral TrialPS Cam Module Insert Trials (9,11,13mm)Tibial BaseplateFin PunchVISIONAIRE Core ValuesEfficiencyConfidenceAccuracySimplifying surgery, reducing costs,Personalized, reliable solutions,Advanced surgical precision,and improving performanceleading to increased satisfactionresulting in reproducible outcomes

VISIONAIRE Personalized ServicesRegionalcustomer supportRegionalengineersSimplified surgery.Personalized performance.In-housemanufacturingIn-housedesignThe ‘brain trust’engineering QCThe ‘pit crew’personalized imaging techs

Conventional Total KneeExpensiveTotal knee arthroplasty is a complicated and expensive procedure. There are many resources required for eachTKA, including numerous hospital staff, multiple instrument trays and rooms full of back-up inventory.All of this is required and necessary for just one case. For hospitals and surgeons performing multiple TKAsa day, the resource requirements can double or triple to support those surgeries, thus increasing the cost ofsurgery as well.ComplexDue to the complexity of surgery, one total knee procedure may require up to 7 or more trays of sterileinstruments. With this number of trays and instruments required for surgery, the opportunity for inefficienciesincrease as well. ChallengesLong setup and turnover due to number of instruments and trays150 to 175 lbs (68 to 80kgs) of instruments that need to be moved around and setup for each surgeryChallenging instrumentation and set up for less experienced nurses and staffConventional Total Knee Arthoplasty requires a lot of equipment and resources, which can make the procedureexpensive, complex and challenging. These are just some of the challenges hospitals and staff face each day.Below is an image of all the instruments and implants needed to support just one total knee surgery.Instruments and Implants required for conventional TKA7 trays 150lbs (68kgs)63 boxes of implants

VISIONAIRE FastPakCost-EffectiveSmith & Nephew’s VISIONAIRE FastPak is a cost-effective approach to total knee arthroplasty. VISIONAIREFastPak includes VISIONAIRE Cutting Guides and size-specific single-use instruments. This can significantlyreduce the resources and time required for a total knee arthroplasty.5SimpleVISIONAIRE FastPak simplifies the requirements for a total knee. The number of trays required for surgery arereduced to only 2-3 trays. The patient’s implant size is known prior to surgery, so only the instruments andimplants specific to that patient are needed.BenefitsVISIONAIRE FastPak offers a patient-specific solution to help reduce complexity and cost in the OR while helpingto improve patient alignment. This solution allows a surgeon and staff to to know exactly what to expect insurgery and take in exactly what is needed for that procedure. FastPak includes all of the size-specific single-useinstruments and the patient-matched cutting guide. Below is an image of the instrument trays and implants thatare required for a surgery utilizing VISIONAIRE FastPak. FastPakVISIONIARE Cutting GuidesMetal AP cutting blockReam-through femoral trialInsert trials (9, 11, 13mm)Tibial baseplatePS cam moduleInstruments and Implants needed for VISIONAIRE FastPak3 trays 75lbs (34kgs)24 boxes of implants

EfficiencyVISIONAIRE uses 57% less trays for total knee surgery.

Efficiency is the ability to accomplish a job with minimal expenditure of time and effort. VISIONAIRE FastPak helps achieve efficiency by reducing instrument trays required for surgery and improving OR setup and turnover time.5FastPakTotal knee arthroplasty with standard instrumentation requires up to 7 or more trays of instruments. With theVISIONAIRE FastPak, a knee surgery can be completed with only 2-3 instrument trays. Advantages57% reduction in instrument traysNew, sterile instruments for every surgery to make precise bone cuts.Streamlined surgical procedure with less instrumentation and time required for OR setup and turnover5Potential to reduce surgical delays due to missing, broken or comprimised instruments and trays due to thefact there are less instruments required.Potentially less risk of contamination due to reasons stated aboveAvg Tourniquet Time (min)Room Turnover Time (min)p .022107.2p .02412012042% shorter86.831% shorter10083.2808063.360n 30620n 500STDSTDVISIONAIRE TechnologyVISIONAIRE Technologyn 306Patient-Specific Versus Conventional Instrumentation for Total Knee Arthroplasty: Peri-Operative and Cost Differences;J Arthroplasty (2014) DeHaan AM, Huff, TW, et al604040n 50100200

ConfidenceConfidence is having trust or reliability in something. VISIONAIRE FastPak helps add confidence inthe OR by reducing the complexity of surgery with patient-specific kits and less instruments requiredfor surgery.Ease of UseReducing instrument trays by 57% in the OR significantly helps the flow in the OR. This makes the procedureless complicated for less experienced nurses and OR staff. So, for hospitals or surgeons who do not have adedicated Ortho team, this simplifies surgery for rotating staff.FlexibilityHospital staff can also take confidence in the fact that single use instruments from the VISIONAIRE FastPakcan be used in a manner that best suits their hospital. Smith & Nephew offers several different solutions thatutilize this new technology. Some of those solutions are described below. VISIONAIRE FastPak: These kits include the VISIONAIRE Cutting Guides and all the size-specific single-useinstruments. This option allows for the least amount of instruments and trays to be used in the OR. VISIONAIRE Digital Templating: This option allows the hospital or surgeon to use digital templatingtechnology to determine the implant size pre-operative, therefore requiring a smaller, more precise range ofsingle-use instruments necessary for the OR. Standard Instrumentation: Single-use size-specific instruments will also be offered in individual, sizespecific peel packed kits, allowing the surgeon to determine the size intraoperatively and open the correctsingle-use trials to be used in surgery.Peace of MindThe surgeon has confidence that he will have new, sterile instruments specific for each patient and the ORstaff can have confidence that setup, surgery and cleanup will be simple with minimal time commitment.

Proven PerformanceVISIONAIRE FastPak is available for our LEGION Total Knee System. LEGION is based on the GENESIS IItotal knee system, which has over 20 years of clincial history, giving you confidence in your implant andinstruments. LEGION Total Knee SystemSeamless transition from primary, revision to hingeAnatomical BaseplateReam Through Femoral Trial for PS box prepEnvironmentally ResponsibleSmith & Nephew understands the benefits FastPak can offer a hospital and surgical staff, but we also careabout our impact on the environment. We have established a recycling program for our single-use instrumentsto help ensure an environmentally friendly solution for our customers. All of the contents of the VISIONAIREFastPak can be recycled. Please contact your local sales rep to enroll in this program.

AccuracyAccuracy is the condition or quality of being true, correct or exact. VISIONAIRE FastPak helps achieveaccuracy in alignment, rotation and sizing by incorporating the VISIONAIRE Cutting Guides in everypatient-specific kit.Segment bone & cartilageCreate 3D bone modelAlign implant on bone modelActual postop X-Ray showingimplanted componentsVISIONAIRE Cutting Guides incorporate a patient’s MRI and full leg X-Ray to determine mechanical axisalignment, rotation and sizing. Utilizing common anatomical land marks from these images, an engineercreates a precise surgical plan based on each surgeon’s specific preferences.Femoral RotationCoronal Plane Alignmentp .05p .0591%n 150STD90%80%78%n 0%20%10%0%n 48n 46VISIONAIRE TechnologyA comparison of conventional and patient-specificHeyse J. Improved femoral component rotation in TKAinstruments in total knee arthroplasty;using patient-specific instrumentation; The Knee; 2012International Orthopaedics; Jul 2013;Daniilidis, Tibesku (Germany)100%10%0%

SizingThe bone models created from the patient’s MRI also allow the engineer to determine the most accurate Smith& Nephew implant size combination for the patient. VISIONAIRE Cutting Guide sizing has demonstratedaccuracy as high as 94% in published reports.4The combination of the VISIONAIRE Cutting Guides and the single-use instruments creates an opportunity toincrease efficiencies in the OR and provide just the instruments and sizes needed for surgery.

References1Patient-Specific Versus Conventional Instrumentation for Total Knee Arthroplasty: Peri-Operative and Cost Differences;J Arthroplasty (2014) DeHaan AM, Huff, TW, et al2 Heyse J. Improved femoral component rotation in TKA using patient-specific instrumentation; The Knee; 20123 Daniilidis K, Tibesku C. Frontal plane alignment after total knee arthroplasty using patient-specific instruments. Int Orthop.2012 Dec 12.4 Kamali Bali, MBBS, MS, DNB, Peter Walker, FRACS, and Warwick Bruce, FRACSJ Arthroplasty. 2012 Jun;27(6):1149-54. Epub2012 Jan 27.5 Patient-Specific Versus Conventional Instrumentation for Total Knee Arthroplasty: Peri-Operative and Cost Differences;J Arthroplasty (2014) DeHaan AM, Huff, TW, et alSmith & Nephew, Inc.1450 Brooks RoadMemphis, TN 38116USAwww.smith-nephew.com Trademark of Smith & Nephew Registered US Patent and Trademark Office. 2015 Smith & Nephew, Inc.02897 V1 01/15

Smith & Nephew’s VISIONAIRE FastPak is a cost-effective approach to total knee arthroplasty. VISIONAIRE . LEGION is based on the GENESIS II total knee system, which has over 20 years of clin

Related Documents:

Plastic surgery Cosmetic Surgery Reconstructive Surgery Aesthetic Surgical & Non-Surgical procedures Craniofacial Surgery Rhinoplasty & Otoplasty Hand Surgery or Chiroplasty Oral and Maxillofacial Surgery Trauma Surgery Skin Rejuvenation and Resurfacing Anesthesia for Plastic Surgery

Reserved/Personalized License Plates-Application For VLIC-4.420 Original Date: 09/28/1990 Revision Date: 07/15/2017 Personalized Plate Policy Violations Create Personalized Message Relinquish Personalized/Reserved Plates Governor Series and Low Number License Plates Customer Requirements-Original/Reissue Front Counter CSR-Original/Reissue

ii. personalized medicine from a regulatory perspective 5 1. defining personalized medicine 5 2. fda's unique role and responsibilities in personalized medicine 11 iii. driving toward and responding to scientific advances 14 1. building the infrastructure to support personalized medicine 16 2. recent organizational efforts 20 iv.

The device performed as des ired'a'nd was as safe and as effective as the predicate devices. . Plastic and Reconstructive Surgery. N81Jrosuirgery, Gastrointestinal and Affili ted Organ Surgery, Urological Surgery, Orthopedic Surgery, Gynecological Surgery, ThoraclO Surgery, Lta aoscopic Surgery. .

Jennifer S. Schwartz, MD Assistant Professor of Surgery Department of Surgery Division of General & Gastrointestinal Surgery The Ohio State University Wexner Medical Center Robotics in General Surgery Objectives Brief History of Robotics in General Surgery Robotic General Surgery

Jennifer S. Schwartz, MD Assistant Professor of Surgery Department of Surgery Division of General & Gastrointestinal Surgery The Ohio State University Wexner Medical Center Robotics in General Surgery Objectives Brief History of Robotics in General Surgery Robotic General Surgery

History of surgery - Wikipedia Surgery is the branch of medicine that deals with the physical manipulation of a bodily structure to diagnose, prevent, or cure an ailment. The history and literature of surgery : Billings : Internet Archive The history and literature of surgery. by. The Historical Timeline of Surgery Verywell Health Find out about the history of surgery from this

Procedure Code Service/Category 15824 Neurology 15826 Neurology 19316 Select Outpatient Procedures 19318 Select Outpatient Procedures 20930 Joint, Spine Surgery 20931 Joint, Spine Surgery 20936 Joint, Spine Surgery 20937 Joint, Spine Surgery 20938 Joint, Spine Surgery 20974 Joint, Spine Surgery 20975 Joint, Spine Surgery