CIRRUS photoCertainty meets versatility

2

CIRRUS photoOne system for fundus imaging and OCTBroader clinical insights, greater diagnostic certainty and added practicevalue – the new CIRRUSTM photo from ZeISS delivers all that in a single,integrated system for both fundus imaging and OCT.CIRRUS photo combines a full mydriatic/non-mydriatic fundus camerawith proven CIRRUS HD-OCT technology in one compact and highlyversatile system. Available in two models, CIRRUS photo 600 andCIRRUS photo 800, it provides multiple insights for comprehensiveretina and posterior segment care.Visualize findings from various modalities. Correlate data from high-densityOCT cubes, thickness and layer maps with results from superb color fundusimages as well as fundus autofluorescence and fluorescein angiography*images. All in one convenient sitting.Achieve a more comprehensive clinical evaluation. Save time and space.enhance the examination experience for your patients and staff.Have it all in a single system for fundus imaging and OCT.* Only with CIRRUS photo 8003

Broader clinical insightsBy simultaneously providing high-quality fundus images andOCT scans, CIRRUS photo facilitates broader, more comprehensivediagnostic insights. Each modality by itself is a premier qualitydiagnostic instrument. Together, they enable you to characterizeand examine the patient’s condition more completely and easily.A fundus camera and a CIRRUS HD-OCTCIRRUS photo is a full-featured mydriatic/CIRRUS photo incorporates unsurpassednon-mydriatic fundus camera.OCT technology with its provenCIRRUS HD-OCT capabilities.Exceptional visualizationsGreat detail densityLegendary ZEISS optics let you visualize findingsHighly dense OCT data cubes make even thewith high-resolution clarity and sharpness.smallest details clearly visible.Single-shot fundus autofluorescenceAnalysis you can trustFundus autofluorescence imaging designed forDetailed OCT scans and change analyses providefast and easy assessment of dry AMD.highly reliable diagnostic data in seconds.High-resolution angiographiesAlso available with fluorescein angiography* andindocyanine green angiography, CIRRUS photoequips you with a more detailed diagnostic view.* Only with CIRRUS photo 8004

Interactive reviewThe system’s one-of-a-kind MultiMode Navigator enablesinteractive analysis of registered fundus images and OCT cube scans –horizontal and vertical direction.Precise registrationOCT scans are automatically registered with different types offundus images including color fundus, angiography* and fundusautofluorescence* images, bringing depth to your analysis.Multimodal assessmentsCIRRUS photo allows you to conduct examinations with variousmodalities and to correlate the findings at one single workstation.Every fundus image can also be registered independently of theacquisition sequence, along with other flexible combinations.(inset magnified to show detail)Orientation at a glanceWhether for a quick overview or point-by-point comparisons,thumbnails provide at-a-glance insights.5

Versatile visualizationsHarada’s diseaseRetinalpigment ephithelialdetachmentProliferative diabeticretinopathyGlaucoma6

17

Greater diagnostic certaintyComprehensive, high-quality diagnostics form the basis for informeddecisions. With its superb multimodality visualizations, CIRRUS photodelivers exceptional insights, supporting greater diagnostic accuracyand certainty.Extraordinary image qualityCIRRUS photo features standard-setting CIRRUS HD-OCT technology and a full-featuredmydriatic/non-mydriatic fundus camera. The result – visualizations of a quality that istruly extraordinary.Overview at a glance8See the details

Algorithm excellenceZeISS and its research collaborators have developed advanced algorithms to measureand display layers.Accurate centeringFoveaFinder and AutoCenter automatically ensure that measurements are made inthe correct locations, taking the pressure off the operator to perfectly center the scans.Comparison capabilitiesCIRRUS data cubes are automatically registered with data from prior visits, allowing formore detailed comparisons.Normative databasesDiversified normative databases for ONH, RNFL and macular thickness facilitate evenmore at-a-glance assessments.Specific fundus detailsenabling efficient cross-modality analysis, CIRRUS photo allows easy switchingbetween fundus images registered with OCT scans and maps.9

Fundus and OCT details in one viewCIRRUS photo delivers combined fundus and OCT reports that enablequick, at-a-glance assessments for a wide variety of retina and posteriorsegment disorders.10

Get the complete picture in a single viewONH & RNFL OU AnalysisSingle Eye Analysis10aGPA Analysis

Enhanced HD Raster Single LineEnhanced HD 5 Line RasterAnterior Segment10b

Macular Thickness AnalysisMacular Change AnalysisAdvanced VisualizationCIRRUS photo offers a versatilesuite of OCT analyses, whichmeans more insight into yourtreatment decisions.11

Added practice valueAs a highly efficient and versatile instrument, CIRRUS photo offerssubstantial value. In addition to streamlining your workflow andsupporting more comprehensive assessments, it saves time and space.By eliminating the need to move patients to another instrument,it also enhances the examination experience – for patients andpractice staff alike.CIRRUS photo – a single workstationcomplete with joystick, keyboardand TFT monitor for comprehensiveclinical evaluations.12

Konturdicke 8ptKonturfarbe 60% kFüllung 10% knetFundusphotographyBiometryOCTportVisual FieldFORUM ArchiveInstrument(non-DICOM)Back officeInstrument(no network)Practice receptionareaFORUM ViewerExam lane 1Exam lane 2Electronic Medical RecordMore clinical efficiencyMore practice efficiencyWith CIRRUS photo, you can add a color fundusThe ability to capture all necessary fundus imagesimage to an OCT examination for additionaland HD-OCT scans in a single patient setup savesassessment – in seconds and without additionalyou time and space. As such, CIRRUS photo isdilation.ideally suited for comprehensive practices workingwith or without angiography.More time for patientsMore flexibilityEasy, convenient and operator-independentFeaturing a modular design, CIRRUS photo lets youstorage of CIRRUS photo data is provided byindividually choose the diagnostic modalities andFORUM . Via the FORUM Archive & Viewer,clinical insights best suited for your practice needs –you can effortlessly exchange examination resultswhether OCT, color and red-free fundus imaging,with EMR systems and other diagnosticfundus autofluorescence, fluorescein angiography,instruments – even with other practice sites.ICG angiography, and anterior segment.Image courtesy of:Annette Brusis MD, Eye Center Heppenheim Dr. Wolff, Dr. Brusis, Dr. Köster, Germany (p. 2, 11)Antonio Ferreras MD, Miguel Servet University Hospital, Spain (p. 6, 7, 11)Matthias Jütte MD, Ophthalmic Practice Jütte, Jurkutat, Ilgner, Germany (p. 4, 8)13

Technical dataMain systemCIRRUS photo 600/800Field angle45 and 30 Pupil diameter 4.0 mm; 3.3 mm (30 small pupil mode) 2.0 mm for OCT scans onlyRefractive error compensation 35 D -35 D, continuousWorking distance40 mm (patient’s eye – front lens)Fixation targetsInternalExternal and internalAttention mode and free position or programmed sequencesDatabasePatient information and images with field angle, FA time, R/L recognition and date of visit are storedMonitor23” TFT (1920 x 1200)Instrument tableAsymmetric, suitable for wheelchairsAccessoriesNetwork printer, sliding keyboard shelf, network isolator,FORUM eye care data management systemFundus cameraCapture modesColor, red-free, blue, red and fundus autofluorescence pictures,as well as pictures of the anterior segment,CIRRUS photo 800 only: fluorescein angiography and ICG angiographyFiltersFilters for green, blue and fundus autofluorescence images, UV/IR barrier filtersCIRRUS photo 800 only: FA ICGA: exciter and barrier filtersCapture sequenceFrom 1.5 seconds (depends on flash energy)Capture sensorCCD 5.0 megapixelsXenon flash lamp16 flash levels (30 Ws)CIRRUS photo 800 only: 24 flash levels (80 Ws)OCTTechnologySpectral domain OCTOptical sourceSuperluminescent diode (SLD), 840 nmScan speed27,000 A-scan per secondA-scan depth2.0 mm (in tissue), 1024 pointsResolutionAxial 5 µm (in tissue), transverse 15 µm (in tissue)ComputerOperating systemWindows EmbeddedHard driveStorage of over 30,000 fundus images with OCT cube scans (present size: 320 GB)InterfacesUSB ports and network connectors, DVI portExport/importImage formats: BMP, TIFF, JPEG, PNGPatient list, DICOM MWL, DICOM storageDimensionsMain unit410 mm x 480 mm x 680 mm (W 16.1 x D 18.9 x H 26.8 inches)Weight (main unit)33 kg (72.7 lbs)Rated voltage100 240 V 10%Frequency50 / 60 HzPower consumption400 VA (w/o instrument table)14

The moment a subtle change in pathologybecomes a turning point in care.This is the moment we work for.// CirrusMade By Carl Zeiss

ArgentinaCarl Zeiss Argentina S.A.Calle Nahuel Huapi 4015 / 25C1430 BCO Buenos AiresArgentinaPhone: 54 11 45 45 66 61bruzzi@zeiss.com.arAustraliaCarl Zeiss Pty LtdTenancy Office 4, Level 140-52 Talavera RoadNorth Ryde NSW 2113AustraliaPhone: 61 2 9020 1333med@zeiss.comAustriaCarl Zeiss GmbHLaxenburger Str. 21100 ViennaAustriaPhone: 43 1 79 51 80austria@zeiss.orgBelgiumCarl Zeiss NV-SAIkaroslaan 491930 ZaventemBelgiumPhone: 32 2 719 39 11info@zeiss.beBrazilCarl Zeiss do Brasil Ltda.Av. Naçoes Unidas, 21711CEP04795-100 São PauloBrazilPhone: 55 11 5693 5521medbrasil@zeiss.orgCanadaCarl Zeiss Canada Ltd.45 Valleybrook DriveToronto, ON M3B 2S6CanadaPhone: 1 800 387 8037czcmed@zeiss.comChinaCarl Zeiss Shanghai Co. Ltd.1/f., Ke Yuan Building11 Ri Yin Nan RoadWaigaoqiao Free Trade Zone2005 Yang Gao Bei RoadShanghai 200131ChinaPhone: 86 21 5048 17 17sro@zeiss.com.cn 0297Carl Zeiss Meditec AGGoeschwitzer Strasse 51–5207745 JenaGermanywww.meditec.zeiss.com/cirrusphotoCzech RepublicCarl Zeiss spol. s.r.o.Radlická 14/3201150 00 Prague 5Czech RepublicPhone: 420 233 101 221zeiss@zeiss.czFranceCarl Zeiss Meditec France SAS60, route de Sartrouville78230 Le PecqFrancePhone: 33 1 34 80 21 00med@zeiss.frGermanyCarl Zeiss Meditec VG mbHCarl-Zeiss-Strasse 2273447 OberkochenGermanyPhone: 49 7364 20 6000vertrieb@meditec.zeiss.comSurgical Ophthalmology:Phone: 49 800 470 50 30iol.order@meditec.zeiss.comHong KongCarl Zeiss Far East Co. Ltd.Units 11-12. 25/FTower 2, Ever Gain PlazaNo. 88 Container Port RoadKwai ChungHong KongPhone: 852 2332 0402czfe@zeiss.com.hkIndiaCarl Zeiss India Pvt. Ltd.Plot No.3, Jigani Link RoadBommasandra Industrial AreaBangalore - 560 099IndiaPhone: 91 80 4343 8000info@zeiss.co.inItalyCarl Zeiss S.p.A.Viale delle Industrie 2020020 Arese (Milan)ItalyPhone: 39 02 93773 1infomed@zeiss.itJapanCarl Zeiss Meditec Japan Co. Ltd.Shinjuku KuTokyo 160-000322 Honchio-ChoJapanOphthalmic instruments:Phone: 81 3 33 55 0331medsales@zeiss.co.jpSurgical instruments:Phone: 81 3 33 55 0341cmskoho@zeiss.co.jpMalaysiaCarl Zeiss Sdn Bhd.Lot2, Jalan 243/51 A46100 Petaling JayaSelangor Darul EhsanMalaysiaPhone: 60 3 7877 50 58malaysia@zeiss.com.sgMexicoCarl Zeiss de México S.A. de C.V.Avenida Miguel Angel de Quevedo49604010 Mexico CityMexicoPhone: 52 55 59 99 0200cz-mexico@zeiss.orgNetherlandsCarl Zeiss B.V.Trapezium 300Postbus 3103364 DL SliedrechtNetherlandsPhone: 31 184 43 34 00info@zeiss.nlNew ZealandCarl Zeiss (N.Z.) Ltd.15B Paramount DriveP.O. Box 121 - 1001Henderson, Auckland 0650New ZealandPhone: 64 9 838 5626med@zeiss.comPolandCarl Zeiss sp. Z o.o.ul. Lopuszanska 3202-220 WarsawPolandPhone: 48 22 858 2343medycyna@zeiss.plSingaporeCarl Zeiss Ptd. Ltd.50 Kaki Bukit PlaceSingapore 415926SingaporePhone: 65 6741 9600info@zeiss.com.sgSouth AfricaCarl Zeiss (Pty.) Ltd.363 Oak AvenueFerndaleRandburg 2194South AfricaPhone: 27 11 886 9510info@zeiss.co.zaSouth KoreaCarl Zeiss Co. Ltd.Seoul 121-828Mapo-gu141-1, Sangsu-dong2F, BR Elitel Bldg.South KoreaPhone: 82 2 3140 2600korea@zeiss.co.krSpainCarl Zeiss Meditec Iberia S.A.U.Ronda de Poniente, 15Tres Cantos28760 MadridSpainPhone: 34 91 203 37 00info@zeiss.esSwedenCarl Zeiss ABTegeluddsvaegen 7610254 StockholmSwedenPhone: 46 84 59 25 00info@zeiss.seSwitzerlandCarl Zeiss AGFeldbachstrasse 818714 FeldbachSwitzerlandPhone: 41 55 254 7200med@zeiss.chThailandCarl Zeiss Thailand90 CyberWorld Tower A,36th Floor, Unit A 3601230 Ratchadapisek RoadHuaykhwang, Bangkok 10310ThailandPhone: 66 2 248 8787thailand@zeiss.com.sgUnited KingdomCarl Zeiss Ltd.509 Coldhams laneCambridgeCAMBSCB1 3JS,United KingdomPhone: 44 1707 871200info@zeiss.co.ukUnited States of AmericaCarl Zeiss Meditec, Inc.5160 Hacienda DriveDublin, CA 94568USAPhone: 1 925 557 4100info@meditec.zeiss.comPublication No: 000000-2031-489 CIR.4718 CZ-XI/2012The contents of the brochure may differ from the current status of approval of the product in your country. Please contact our regional representative for more information.Subject to change in design and scope of delivery and as a result of ongoing technical development. CIRRUS, FORUM, Advanced Visualization, Guided Progression Analysis, GPA, FoveaFinder, AutoCenter are either trademarks or registered trademarks of Carl Zeiss Meditec in the United States and/or other countries. 2012 by Carl Zeiss Meditec, Inc. All copyrights reserved. 1112 2.5MYour local contact:

the correct locations, taking the pressure off the operator to perfectly center the scans. Comparison capabilities CIRRUS data cubes are automatically registered with data from prior visits, allowing for more detailed comparisons. Normative databases Diversified normative databases for ONH, RNFL and macular thickness facilitate even

Related Documents:

ZEISS GT2 3D 1.4 ZEISS GT2 3D Short 1.5 ZEISS Individual Single Vision 1.6 ZEISS 3DSingle Vision 1.7 SOLA HDV 1.8 SOLA Elan HDV 1.9 SOLA Elan HD 1.10 SOLA Elan Short 1.11 SOLAOne HD 1.12 Compact ULTRA HD 1.13 AO Easy HD 1.14 SOLA ATL HD Single Vision 1.15 Customized Wrap Rx Only Lenses ZEISS Individual

BEST Zeiss Individual PAL Zeiss Individual SV BETTER Zeiss GT2 3DV Zeiss 3D SV GOOD Zeiss GT2 3D / short Electronic Measuring The wave of the future All dispensaries will have one As common as the corneal reflex pupillometer Takes frame measurements Takes POW measurements High degree

ZEISS provides a broad spectrum of precision lenses for better vision; from endless-frame and easy-to-handle options with high visual performance to optimally individualised solutions. GT2 3D Gradal Individual EyeFit Gradal Plus ZEISS Progressive Superb ZEISS Progressive Individual 2 ZEISS Progre

of the measuring room. ZEISS is a machine manufacturer, calibra- tion laboratory, measurement service provider and service technician. We know the challenges in the measuring room from our own experience from A to Z. ZEISS Original Accessories are continuously tested, developed and improved. With ZEISS, you are the leader in the measuring room.

fluorescence microscope (Zeiss Axiovert 40 CFL; Carl Zeiss Inc). Images were captured on a cooled CCD camera. Image acquisition and analysis were performed and visualized by fluorescence, and images were obtained on a PC computer using a Zeiss Axiovert 40 CFL fluorescence microscope with Zeiss Zhen microscope soft-ware (Zeiss Inc).

ZEISS TEMPAR starter The entry-level solution ZEISS TEMPAR basic The standard package ZEISS TEMPAR mobile The mobile solution ZEISS TEMPAR precision The precision solution Setup schematic System Logic Box Console Console Console Console No wall mount Wall mount Table stand Wall mount Temperature sensors 4x factory calibrated 0.1 K 1x DAkkS 0.05 K

The CMM specifications are only valid when using original accessories by ZEISS. The specified parameters are observed in the application of the internal test instructions for acceptance testing and in the use of the released standards in accordance with the ISO 10360 series. ZEISS VAST gold 1) ZEISS VAST XT gold1) ZEISS VAST XTR gold1)

Type as per ISO 10360-1:2000 Bridge-type CMM with a moveable bridge Operating mode Motorized/CNC Sensor mounts Fixed installation Software ZEISS CALYPSO, ZEISS GEAR PRO, ZEISS HOLOS ZEISS PRISMO 5 7 . ZEISS VAST gold: stylus: max. length 800 mm, max. weight 600 g incl. stylus adapter, min. stylus tip diameter 0.3 mm. .