Exterior Expansion Joint Systems Architectural Products

JOINTMASTER Expansion Joint Systems They're not just Expansion Joint Systems. They’re masters of movement. Acoustic authorities. Waterproofing warriors. Forbidders of Fire. Air and moisture mercenaries. They’re on a mission to maintain the integrity of buildings in the face of earthquakes, hurricanes, fires and just plain everyday forces. Often the unsung heroes of building protection, they’re built to do what they do every day because that’s what it takes to keep people safe. 2 obsessed with protecting buildings 04 06 26 Why Inpro 04 Why Inpro Exterior Systems 06 Model Number Guide 08 Selection Guide 12 600 Series 20 Transitions Recent Projects 26 Recent Projects inpro.com 800.222.5556 3

ChristChurch, Justice Emergency Services Precinct Christchurch, New Zealand 353 Wall Ceiling System why Our Expansion Joint Fire Barrier Systems are engineered to handle the unique conditions of your building. 4 obsessed with protecting buildings engineered protected manufactured We constantly test and review our systems for continuous innovation to provide you with the best solutions. Yeah we're obsessed, but in a good way. From ensuring smooth transitions for rolling equipment carts, gurneys and wheelchairs, to preventing the spread of smoke and fire, we integrate building protection right into the product's design. As the manufacturer, we verify that only the best products are shipped out to your project. obsessively by design with care inpro.com 800.222.5556 5

Model Number Guide Understanding product numbers We’ve made it even easier for you to place the right system configuration in your next project. Just visit inpro.com to download our industry leading specifications which are adaptable and easy to work with.just like us! Series Model 100 200 300 400 500 600 700 800 900 1000 1100 1200 Dual Elastomeric Seal Systems for Floors/Walls/Ceilings A02 A07 A09 V18 V24 Series/Model Number Glide Plate Seismic Systems for Floors/Walls/Ceilings Center Bar Seismic Systems for Floors/Walls/Ceilings Exterior Seismic Systems for Walls and Roofs Heavy Duty Seismic Systems for Floors FRAME HEIGHT Cover Plate Systems for Floors / Walls / Ceilings Fire Barrier Systems JOINT JOINT WIDTH WIDTH Exterior Compression Seals Foam Seals Silicone Foam Seals Floor to Floor/Roof to Roof Floor to Wall/Roof to Wall Wall to Wall or Ceiling to Ceiling Wall to Corner or Ceiling to Wall Ceiling to Wall for Acoustical Ceiling Systems Ceiling to Ceiling for Acoustical Ceiling Systems 025 1" (25mm) 050 2" (51mm) 075 100 125 150 200 300 350 400 450 500 600 6 Joint Width SEAL COLOR CONDITION Loading Definitions Standard/Moderate/Heavy Duty are designations as they relate to load ratings. These are provided as a guideline to assist in making a preliminary product selection for a given application. “Standard” suggests use in common applications such as typical office settings or other spaces where pedestrian traffic or occasional rubberwheeled traffic like mail carts and light-weight cleaning equipment, luggage, etc. is the norm. “Moderate” suggests applications where occasional heavier maintenance equipment with soft rubber tires (such as gurneys, light duty scissor lifts, motorized cleaning equipment, etc.) would be added to the standard traffic. The systems in this category are comprised of heavier aluminum extrusions, with thicker walled extruded rubber inserts. “Heavy Duty” is for applications where truly heavy loads (such as vehicles) or high-point loads (such as mobile medical equipment, coin carts, materials handling equipment, etc.) are the norm. They are capable of multi-directional movements and are also available in surface or blockout mounted variations. Joint Width 038 Condition Seismic Systems for Floors Condition A01 101 - A01 - 025 Elastomeric Seal Systems for Floors/Walls/Ceilings 1½" (38mm) 3" (76mm) 4" (102mm) 5" (125mm) 6" (152mm) 8" (203mm) 12" (305mm) 14" (356mm) 16" (406mm) 18" (457mm) 20" (508mm) 24" (600mm) obsessed with protecting buildings Forest Park Middle School Franklin, WI 114 ceiling system, 432 floor system, 300 wall system inpro.com 800.222.5556 7

Exterior Systems Oregon Health And Science University, Portland, Oregon Floor Systems, Interior Exterior Wall Systems, Roof Systems, Insulated Vapor Barrier Pleated Seal System 8 Metal Wall System Metal Roof System Bellows Roof System Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint Opening 2"-36" (50mm – 900mm) 1"-24" (25mm – 600mm) 1"-36" (25mm – 900mm) 2"-36" (50mm – 900mm) Movement /- 50% of Joint Width 50% of Joint Width 50% of Joint Width 50% of Joint Width obsessed with protecting buildings inpro.com 800.222.5556 9

Austin Bergstrom International Airport Austin, TX 1200 Foam, 615 Exterior Wall System, 620 Exterior Wall System, 114 Wall Ceiling System, 115 Wall Ceiling System, 432 Floor System, 806 Floor System, 925 Fire Barrier

Pleated Seal Systems % of Movement 50% Joint Width 2" (50mm) – 24" (600mm) Protection that seamlessly integrates into any building facade using our Santoprene Seals. Industry unique seal maintains tight, linear profile. Linear Santoprene Seal design allows for fluid seismic movement during joint expansion and contraction. Field heat-weldable Santoprene Seals for weather tight seams and crisp transitions. Seal walls are among the thickest in the industry to allow for installation in soffits and corridor ceilings with no sagging. 615 Series - Flush Mount S W B A H1 A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown) 616 Series - Flush Mount S S C S H1 H1 W H1 A Throat-mount brackets reduce sightline to width of seal only. B Insulated Vapor Barrier option available. C Pleated Santoprene Seal design allows for fluid seismic movement. Application Wall/Wall Ceiling/Ceiling Wall/Corner Wall/Ceiling 12 System 615-A07-050 615-A07-075 615-A07-100 615-A07-125 615-A07-150 615-A09-050 615-A09-075 615-A09-100 615-A09-125 615-A09-150 H1 H2 S Joint Width US mm Frame Height 1 US mm Height 2 US mm Sightline US mm 2" 3" 4" 5” 6" 2" 3" 4" 5” 6" 2 3/8" 2 3/8" 2 3/8" 2 3/8” 2 3/8" 2 3/8" 2 3/8" 2 3/8" 2 3/8” 2 3/8" obsessed with protecting buildings 60 60 60 60 60 60 60 60 60 60 W A07 Wall/Wall, Ceiling/Ceiling (12" (300 mm) system shown) W 51 76 102 127 152 51 76 102 127 152 W A09 Wall/Corner Wall/Ceiling (3" (75mm) system shown) * * * * * * * * * * * * * * * * * * * * 2" 3" 4" 5” 6" 2" 3" 4" 5” 6" B 51 76 102 127 152 51 76 102 127 152 Movement /- Blockout US mm * * * * * * * * * * * * * * * * * * * * Horizontal US mm 1" 1 1/2" 2" 2 1/2” 3" 1" 1 1/2" 2" 2 1/2” 3" 25 38 51 63 76 25 38 51 63 76 Vertical US mm 1" 1 1/2" 2" 2 1/2” 3" 1" 1 1/2" 2" 2 1/2” 3" 25 38 51 63 76 25 38 51 63 76 Application Wall to Wall Wall to Corner Larger sizes available. System 616-A07-200 616-A07-250 616-A07-300 616-A07-450 616-A07-600 616-A09-200 616-A09-250 616-A09-300 616-A09-450 616-A09-600 W H1 H2 S B Joint Width Frame Height 1 Height 2 Sightline Blockout US 8" 10" 12" 18" 24" 8" 10" 12" 18" 24" mm 200 250 300 450 600 200 250 300 450 600 US 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" mm 75 75 75 75 75 75 75 75 75 75 US * * * * * * * * * * mm * * * * * * * * * * US 8" 10" 12" 18" 24" 8" 10" 12" 18" 24" mm 200 250 300 450 600 200 250 300 450 600 US * * * * * * * * * * Movement /mm * * * * * * * * * * Horizontal US 4" 5" 6" 9" 12" 4" 5" 6" 9" 12" mm 102 127 152 229 305 102 127 152 229 305 Vertical US 4" 5" 6" 9" 12" 4" 5" 6" 9" 12" inpro.com 800.222.5556 mm 102 127 152 229 305 102 127 152 229 305 13

Tacoma Art Gallery Tacoma, WA 501 Pan Floor System, 491 Wall Ceiling System, Vapor Barrier, F520 Fire Barrier, 611 Exterior System, 616 Exterior System, 651 Roof System, 806 Floor System

H1 11/4" (32mm) S W A07 Wall/Wall (2" (51mm) system shown) Application 601 Series - Flush Mount Wall to Wall Ceiling to Ceiling Wall to Corner Wall to Ceiling Larger sizes available. System 651-A07-025 651-A07-050 651-A07-075 651-A07-100 651-A07-150 651-A07-200 651-A07-300 651-A09-025 651-A09-050 651-A09-075 651-A09-100 651-A09-150 651-A09-200 W H1 H2 S B Frame Height 1 Height 2 Sightline Blockout mm 1" 2" 3" 4" 6" 8" 12" 1" 2" 3" 4" 6" 8" 25 51 76 102 152 203 305 25 51 76 102 152 203 US mm 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 5/16" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 32 32 32 32 32 32 33 32 32 32 32 32 32 US mm * * * * * * * * * * * * * * * * * * * * * * * * * * Operational Position The Hinged Cover plate or “pan” can be filled with adjacent architectural systems to disguise the expansion joint (glazing, metal panels and the masonry units such as stone and brick). Ideal system for high-end exterior systems or conditions where the structural joint is located in a high-profile position on the building veneer. Flush-mounted exterior system reduces sightline to two reveals of approximately 1" (25mm) and 3" (76mm) dimensions. System is seismic-capable while allowing for daily thermal movement and wind sway. Compression spring shock absorption assembly correctly repositions the pan to the normal position after a system movement. Application Wall to Wall Ceiling to Ceiling System W2 S1 S2 "A" 5 /8" recessed frame designed for inset installations (can be surface mounted as well). Snap-fit cover designed for easy on-site assembly, no exposed fasteners make system ideal for public/high abuse conditions. Clear anodized finish. Custom angles available. H1 Application "A" W1 Wall to Wall Ceiling to Ceiling A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown) W1 W2 Joint Width Frame Height 1 601-A07/A09-300 US 12" mm 601-A07/A09-450 18" 457 601-A07/A09-600 24" 610 305 US 17 1/2" 23 1/2" 29 1/2" obsessed with protecting buildings mm 4 1/4" 5 1/4" 6 1/4" 7 1/4" 10 1/2" 13 1/2" 19 1/2" 2 5/8" 3 5/8" 5" 6 1/2" 9 1/2" 12 1/2" 108 133 159 184 267 343 495 67 92 127 165 241 318 US mm * * * * * * * * * * * * * * * * * * * * * * * * * * mm 445 597 749 H1 S1 S2 Height 2 Sightline Sightline US US US 1 1/2" 1 1/2" 1 1/2" mm 38 38 38 1 3/16" 1 3/16" 1 3/16" mm 30 30 30 3 1/16" 3 1/16" 3 1/16" Thermal Movement /- Seismic Movement /Horiz. Vert. mm US mm US mm 78 1" 25 1" 25 78 1" 25 1" 25 78 1" 25 1" 25 Horiz. Vert. US mm 6" 9" 12" 152 229 305 Wall to Corner Wall to Ceiling System S S 300E-A07-025 300E-A07-050 300E-A07-075 300E-A07-100 300E-A07-150 300E-A07-200 300E-A07-250 300E-A07-300 300E-A09-025 300E-A09-050 300E-A09-075 300E-A09-100 300E-A09-150 300E-A09-200 300E-A09-250 300E-A09-300 1" 1 1/2" 2" 3" 4" 6" 1/2" 1" 1 1/2" 2" 3" 4" H1 H2 S B Height 2 Sightline Blockout mm 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 US * * * * * * * * * * * * * * * * mm * * * * * * * * * * * * * * * * 1/2" 1" 1 1/2" 2" 3" 4" 6" 1/2" 1" 1 1/2" 2" 3" 4" mm 13 25 38 51 76 102 152 13 25 38 51 76 102 A09 Wall/Corner Wall/Ceiling (2" (51mm) system shown) Frame Height 1 US 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 13 25 38 51 76 102 152 13 25 38 51 76 102 Vertical US W W W mm 25 51 76 102 152 203 254 305 25 51 76 102 152 203 254 305 1/2" mm S S W W Joint Width US 1" 2" 3" 4" 6" 8" 10" 12" 1" 2" 3" 4" 6" 8" 10" 12" US H1 H1 A07 Wall/Wall Ceiling/Ceiling (2" (51mm) system shown) System available in any variation of size for 10" (250mm) -36" (750mm) expansion gaps. 16 Closed/Nominal Position US Movement /Horizontal H1 H1 300E Series - Glide Plate Closed/Nominal Position A09 Wall/Corner (2" (51mm) system shown) Joint Width US SS W W % of Movement 50% Joint Width 12" (305mm) – 36"(914mm) urface-mount frame S accommodates uneven joint widths. Rubberized washers prevent the elements from penetrating the cover plate at anchor points. Factory formed transitions available. Mill finish standard – custom finishes available. H1 S H1 W H1 11/4"(32mm) Metal Wall Systems 651 Series - Surface Mount US 5" 6" 9" 10" 14" 18" 24" 26" 4 5/8" 6 1/8" 8 1/8" 9 1/8" 12 1/8" 15 1/8" 21 5/8" 23 5/8" mm 127 152 229 254 356 458 610 661 117 156 206 232 308 384 549 600 US 2" 2" 3" 3" 4" 5" 7" 7" 2" 2" 3" 3" 4" 5" 7" 7" Movement /mm 51 51 76 76 102 127 178 178 51 51 76 76 102 127 178 178 Horizontal US 1/2" 1" 1 1/2" 2" 3" 4" 5" 6" 1/4" 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" mm 13 25 38 51 76 102 127 152 6 13 19 25 38 51 64 76 Vertical US 1/4" 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 3/4" 3/4" 7/8" 1" 1 1/4" 1 1/2" 2" 2 1/2" inpro.com 800.222.5556 mm 6 13 19 25 38 51 64 76 19 19 22 25 32 38 51 64 17

661 Series - Curb Mounted Centering Bar Metal Roof Systems % of Movement 50% Joint Width 1" (25mm) – 12" (300mm) Exterior roof systems available with standard hard-lid aluminum covers. Moisture barrier included. Neoprene weather washers prevent leaking where fasteners Mill finish standard. Factory formed transitions available. SS SS penetrate frames/covers. Application SS 651 Series SS Roof to Roof H1 H1 11/4" (32mm) H1 H1 11/4"(32mm) Roof to Wall W W W W 651-A01 Roof/Roof (2" (50mm) system shown) asy onsite assembly and installation. E Capable of multi-directional seismic movement. Moisture barrier included. Neoprene weather washers prevent leaking where fasteners penetrate frames/covers. Surface mount accommodates uneven joint widths. Factory formed transitions available. Application Roof to Roof Roof to Wall System 651-A01-025 651-A01-050 651-A01-075 651-A01-100 651-A01-150 651-A01-200 651-A01-250 651-A01-300 651-A01-350 651-A01-400 651-A02-025 651-A02-050 651-A02-075 651-A02-100 651-A02-150 651-A02-200 651-A02-250 651-A02-300 651-A02-350 651-A02-400 W H1 Joint Width Frame Height 1 1" 2" 3" 4" 6" 8" 10" 12" 14" 16" 1" 2" 3" 4" 6" 8" 10" 12" 14" 16" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 5/16" 1 5/16" 1 5/16" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 5/16" 1 5/16" 1 5/16" US mm 25 51 76 102 152 203 254 305 356 406 25 51 76 102 152 203 254 305 356 406 US mm 32 32 32 32 32 32 32 33 33 33 32 32 32 32 32 32 32 33 33 33 Height 2 * * * * * * * * * * * * * * * * * * * * Larger sizes available. ill finish standard. M Plate available in stainless steel. Versatile frame profile allows for a wide range of building applications. 100% movement available. High performance Kynar 500 resin-based coatings optional. H2 US 651-A02 Roof/Wall (2" (50mm) system shown) mm * * * * * * * * * * * * * * * * * * * * S Sightline US 4 1/4" 5 1/4" 6 1/4" 7 1/4" 10 1/2" 13 1/2" 16 1/2" 19 1/2" 22 1/2" 25" 2 5/8" 3 5/8" 5" 6 1/2" 9 1/2" 12 1/2" 15 1/2" 18 1/2" 21 1/2" 25" mm 108 133 159 184 267 343 419 495 572 635 67 92 127 165 241 318 394 470 546 635 B Horizontal * * * * * * * * * * * * * * * * * * * * 1/2" US mm * * * * * * * * * * * * * * * * * * * * obsessed with protecting buildings 661-A01-025 661-A01-050 661-A01-075 661-A01-100 661-A01-150 661-A01-200 661-A01-300 661-A02-025 661-A02-050 661-A02-075 661-A02-100 661-A02-150 661-A02-200 US 1" 1 1/2" 2" 3" 4" 5" 6" 7" 8" 1/2" 1" 1 1/2" 2" 3" 4" 5" 6" 7" 8" mm 13 25 38 51 76 102 127 152 178 203 13 25 38 51 76 102 127 152 178 203 US 1" 1 1/2" 2" 3" 4" 5" 6" 7" 8" 1/2" 1" 1 1/2" 2" 3" 4" 5" 6" 7" 8" W W W W 661-A02 Roof/Wall (2" (50mm) system shown) 661-A02 Roof/Wall (2" (50mm) system shown) W H1 H2 S B Frame Height 1 Height 2 Sightline Blockout US mm 1" 2" 3" 4" 6" 8" 12" 1" 2" 3" 4" 6" 8" mm 13 25 38 51 76 102 127 152 178 203 13 25 38 51 76 102 127 152 178 203 H1 13/8" 13/(35mm) 8" (35mm) Joint Width Vertical 1/2" H1 13/8" (35mm) H1 13/8" (35mm) US mm 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 3/8" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 25 51 76 102 152 203 305 25 51 76 102 152 203 32 32 32 32 32 32 35 32 32 32 32 32 35 US * * * * * * * * * * * * * mm * * * * * * * * * * * * * US 4 1/4" 5 1/4" 6 1/4" 7 1/4" 10 1/2" 13 1/2" 19 1/2" 2 5/8" 3 5/8" 5" 6 1/2" 9 1/2" 12 1/2" mm US 8 3/8" 8 7/8" 9 5/8" 10 5/8" 12 1/8" 14 1/8" 18 1/8" 4 5/8" 5 3/8" 6 3/8" 7 3/8" 9 3/8" 11 3/8" 108 133 159 184 267 343 495 67 92 127 165 241 318 Movement /Horizontal mm US mm 1/2" 213 225 244 270 308 359 460 117 137 162 187 238 289 13 25 38 51 76 102 152 13 25 38 51 76 102 1" 1 1/2" 2" 3" 4" 6" 1/2" 1" 1 1/2" 2" 3" 4" Vertical US mm 1/2" 13 25 38 51 76 102 152 13 25 38 51 76 102 1" 1 1/2" 2" 3" 4" 6" 1/2" 1" 1 1/2" 2" 3" 4" 691 Series - Vertical Curb Mount Application Roof to Roof Roof to Wall Larger sizes available. 18 System Movement /- Blockout H1 61 – 45 Curb Mounted. 6 Frame angled to assist in securing roofing membrane down on 45 curb. Moisture barrier included. Weather washers prevent leaking where fasteners penetrate frames/covers. Factory pre-formed transitions available. Mill finish pre-formed standard. Custom options available. Drain tube optional. System 691-A01-025 691-A01-050 691-A01-075 691-A01-100 691-A01-150 691-A01-200 691-A01-300 691-A02-025 691-A02-050 691-A02-075 691-A02-100 691-A02-150 691-A02-200 asy on-site assembly and installation. E Multi-directional seismic movement. Moisture barrier included. Neoprene weather washers prevent leaking where fasteners penetrate frames/covers. 2x wood blocking mount. Factory formed transitions available. Cover plate available in stainless steel or alternate secondary finishes. Drain tube optional. Mill finish standard. W H1 Joint Width Frame Height 1 1" 2" 3" 4" 6" 8" 12" 1" 2" 3" 4" 6" 8" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 3/8" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" US mm 25 51 76 102 152 203 305 25 51 76 102 152 203 US mm 32 32 32 32 32 32 35 32 32 32 32 32 35 s S s S w W A01 Roof/Roof (2" (51mm) system shown) S Sightline US 4 1/4" 5 1/4" 6 1/4" 7 1/4" 10 1/2" 13 1/2" 19 1/2" 2 5/8" 3 5/8" 5" 6 1/2" 9 1/2" 12 1/2" H1 H1 H1 H1 mm 108 133 159 184 267 343 495 67 92 127 165 241 318 B Blockout US 8 3/8" 8 7/8" 9 5/8" 10 5/8" 12 1/8" 14 1/8" 18 1/8" 4 5/8" 5 3/8" 6 3/8" 7 3/8" 9 3/8" 11 3/8" mm 213 225 244 270 308 359 460 117 137 162 187 238 289 w W A02 Roof/Wall (2" (51mm) system shown) Movement /- Horizontal US 1/2" 1" 1 1/2" 2" 3" 4" 6" 1/2" 1" 1 1/2" 2" 3" 4" mm 13 25 38 51 76 102 152 13 25 38 51 76 102 Vertical US 1/2" 1" 1 1/2" 2" 3" 4" 6" 1/2" 1" 1 1/2" 2" 3" 4" inpro.com 800.222.5556 mm 13 25 38 51 76 102 152 13 25 38 51 76 102 19

D Common Roof Transitions This is merely a sampling of common transition types encountered in the field. Contact a Inpro Expansion Joint expert for more information regarding your specific transition. B CE A Metal Roof Transitions F D This is merely a sampling of common transition types encountered in the field. Contact a Inpro Expansion Joint expert for more information regarding your specific transition. C A A B E DF B C E G C B. Roof to Roof A. Parapet D F D E G F E B FH G C I D E. Roof to Wall D. Vertical to Horizontal Roof to Wall H C. Roof to Wall F. Roof to Wall I E FH G C G. "T" Intersection Roof to Wall 20 E D H. Horizontal to Vertical Roof to Roof I obsessed with protecting buildings H G I. Horizontal to Vertical Roof to Wall H inpro.com 800.222.5556 21

Bellows Roof System Expansion Joints intersect and change directions. Ensure maximum flexibility, clean lines and waterproofing in these critical areas with the application of factory-formed intersections and transitions. Remains watertight during severe seismic movement. Splicing kits are included for simple installation. Flanges available standard as galvanized optional stainless steel, copper, aluminum and EPDM. 672 Series - Bellows/Canted Roof 4" (102mm) 4” (102mm) 4” (102mm) W W W W G01 Canted Roof/Roof (2" (51mm) system shown) Application Movement /- System Horizontal US 672-G01-050 672-G01-075 672-G01-100 672-G01-150 672-G01-200 672-G02-050 672-G02-075 672-G02-100 672-G02-150 672-G02-200 Roof to Roof Roof to Wall G02 Canted Roof/Wall (2" (51mm) system shown) Vertical mm 1" 1 1/2" 2" 3" 4" 1" 1 1/2" 2" 3" 4" US 25 38 51 76 102 25 38 51 76 102 mm 1" 1 1/2" 2" 3" 4" 1" 1 1/2" 2" 3" 4" 25 38 51 76 102 25 38 51 76 102 674 Series - Bellows/Curb Flange 2" (51mm) 2" (51mm) 2" (51mm) 2" (51mm) 2" (51mm) 2" (51mm) 2" (51mm) W W 2" (51mm) W W G01 Curb Flange Roof/Roof (2" (51mm) system shown) Application Roof to Roof Roof to Wall 22 System 674-G01-050 674-G01-075 674-G01-100 674-G01-150 674-G01-200 674-G02-050 674-G02-075 674-G02-100 674-G02-150 674-G02-200 obsessed with protecting buildings G02 Curb Flange Roof/Wall (2" (51mm) system shown) W Movement /- Joint Width US 2" 3" 4" 6" 8" 2" 3" 4" 6" 8" Horizontal mm 51 76 102 152 203 51 76 102 152 203 US 1" 1 1/2" 2" 3" 4" 1" 1 1/2" 2" 3" 4" Vertical mm 25 38 51 76 102 25 38 51 76 102 US 1" 1 1/2" 2" 3" 4" 1" 1 1/2" 2" 3" 4" mm 25 38 51 76 102 25 38 51 76 102 Good Samaritan Hospital Mount Vernon, IL 615 Wall System, 616 System 23

D AE C B D F Bellows Roof Transitions This is merely a sampling of common transition types encountered in the field. Contact a Inpro Expansion Joint expert for more information regarding your specific transition. E F B E D C G B. Roof to Roof A. Parapet F E G F H D C E. Roof to Wall D. Vertical to Horizontal Roof to Wall HF G D 24 F. Roof to Wall I G E H. Horizontal to Vertical Roof to Roof G. "T" Intersection Roof to Wall H C. Roof to Wall I. Horizontal to Vertical Roof to Wall H I obsessed with protecting buildings G Oregon Health & Science University Portland, Oregon F520 Blanket, 200 Series System, 223 Floor Series System, 600 Series System, 616 Wall Series System (Shown), 651 Roof with Insulated Moisture Barrier, Insulated Moisture Barrier System inpro.com 800.222.5556 25

Recent Projects The list below is a sample of projects we’ve completed across the globe. For more information or detailed project profiles, visit inpro.com/jointmaster. Citrus Bowl SunTrust Stadium College of San Mateo Orlando, FL Atlanta, GA San Mateo, CA MGM National Harbor World Trade Center Milwaukee Mitchell Airport CLSB - OHSU Life Sciences UW Platteville Yas Mall Anchorage Museum Phase 2 Anchorage, AK OK State Fairgrounds Expo Center Oklahoma City, OK Las Vegas VA Hospital Las Vegas, NV Owensboro Medical Center Owensboro, KY Texas City High School Texas City, TX Silver Spot movie theater Brookfield, WI Weld County Courts Greeley, CO Jeanne Bellamah Comm Center Albuquerque, NM SUMC Nuclear Medicine Dept Standford, CA Parkland Hospital Dallas, TX Waikiki Shopping Plaza Honolulu, HI BCT-H Barracks Complex Fort Carson, CO Cross Point Church Oconomowoc, WI Rocky Mtn Hospital for Children Denver, CO Abraham Lincoln High School San Fransisco, CA Maui Lani Shopping Center Wailuku, HI Salt Lake County Office Building and Parking Structure Salt Lake City, UT LA Coroners Office Los Angeles, CA River Spirit Casino Tulsa, OK Moab Regional Medical Center Moab, UT Dufur School Dufur, OR Three Rivers Mall Regal Theater Connection Kelso, WA McCully District Park Honolulu, HI Google Tech Corners Bldgs Sunnyvale, CA UNMH Clinical Neuroscience Center Albuquerque, NM Sierra Vista Middle School La Puente, CA Harley Davidson of Scottsdale Scottsdale, AZ Tacoma Art Museum Tacoma, WA Richmond Masonic Temple Richmond, VA Boys & Girls Club @ Shoreline Santa Cruz, CA Alaska Regional Hospital Anchorage, AK Chemawa Indian School Salem, OR Rusnak MB Arcadia Mercedes-Benz Arcadia, CA Santa Clara Square Santa Clara, CA Lake Oswego Water Treatment Plant Portland, OR Pensacola Regional Airport Pensacola, FL Community Hospital of Grand Junction Grand Junction, CO Jefferson Elementary School West Allis, WI Palos Verde Senior Living Peoria, AZ AVA at Esterra Park Redmond, WA Yakama Nation Casino-Exteriors Toppenish, WA Jackson Hole Airport Baggage Claim Jackson Hole, WY Rush University Medical Center Chicago, IL BSU Student Union Transit Center Boise, ID Oakmont Senior Housing Windsor, CA Jefferson Stadium Park Apartments Anaheim, CA Cinemark Movie Theater North Haven, CT SDIA Rental Car San Diego, CA Hospital Expansion & Renovation Laurium, MI Seattle University Fitness Center Seattle, WA Forest park Middle School Franklin, WI UC San Diego Osler Parking La Jolla, CA Kirkwood Public Library Kirkwood, MO Lambert Airport Terminal 1 Baggage St. Louis, MO Biloxi VA Mental Health Biloxi, VA Pima Community College Tuscon, AZ Shinola Hotel Detroit, MI Idaho National Lab Idaho Falls, ID Village of Paletine Police Department Palatine, IL Delta Airlines Lobby / ATO Renovation Sea Tac Airport Seattle, WA Jennie Sealy Galveston, TX Purdue Honors College West Lafayette, IN Wrigley Field renovations Chicago, IL ICD Brookfield Place Dubai, UAE Mercy Cancer Center Joplin, MO Santa Clara Univ Phase 2 Student Residence Santa Clara, CA Hamilton Sussex intermediate school Sussex, WI Nshama Town Square Development Dubai, UAE Cleveland Clinic Abu Dhabi, UAE St. Louis University Residence Hall St. Louis, MO Austin Bergstrom International Airport (ABIA) Austin, TX Oxon Hill, MD Rock County Jail Janesville, WI Milwaukee Art Museum Milwaukee, WI 26 New York City, NY St. Mary's Hospital Century Project Grand Junction, CO obsessed with protecting buildings Milwaukee, WI Portland, OR Platteville, WI Abu Dhabi, UAE The District at Milpitas Milpitas, CA Stanford at Redwood City inpro.com 800.222.5556 27

obsessed with protecting buildings How they look. How they function. And how they protect the health and safety of the people who use them every day. That’s why we make hundreds of architectural products all under one roof and work tirelessly to make sure you and your buildings succeed. Yeah, we are obsessed. But we wouldn’t have it any other way. inpro.com 800.222.5556 World Headquarters S80 W18766 Apollo Drive Muskego, WI 53150 USA IPC Door Wall Protection Ascend Elevator Protection Juniper Commercial Window Treatments Clickeze Privacy Systems Endurant Washroom Systems SignScape Architectural Signage JointMaster Expansion Joint Systems 2019 Inpro Corporation

Exterior Systems Page Number 12 16 17 22 Series 600 300E, 600 600 600 Models 615, 616 300E, 601, 651 651, 661, 691 672, 674 Joint Opening 2"-36" (50mm - 900mm) 1"-24" (25mm - 600mm) 1"-36" (25mm - 900mm) 2"-36" (50mm - 900mm) Movement /-50% of Joint Width 50% of Joint Width 50% of Joint Width 50% of Joint WidthPleated Seal System Metal Wall System Metal Roof System Bellows Roof System

Related Documents:

expansion joint movement and/or excessive heating of the expansion joint material to exceed the maximum rated capability of the expansion joint.) Proco Products, Inc. Page 7 2012 IOM Spool Type Fig. 3 4.1.3 Heat Tracing Over Expansion Joint: Do not use heat tracing over expansion joints. Figure 10: Do Not Heat Trace Over Expansion Joint .

A tied single expansion joint is best used in piping systems without a main anchor. It allows for lateral movement only while also restraining pressure thrust. Example of a Tied Single expansion joint where the expansion joint is installed 90º to the thermal growth of the piping. Because of the rods, the expansion joint is able to absorb

TECHSTAR // Modular ExpansIon JoInts 2 s IntroductIon Modular ExpansIon JoInt systEM The Modular Expansion Joint System (MEJS) is a mechanical device installed in bridge expansion joint openings. The primary function of the MEJS is to permit vehicle traffic to travel smoothly across large expansion joint openings. It does this by dividing the .

EXPANSION JOINT SOLUTIONS MIGUMAX MIGUA 360 SERVICE Introducing MIGUTRANS 4-5 Innovations at MIGUA 6-8 Expansion joints according to joint width/load bearing capacity/ alphabetically sorted 9 Expansion joints according to application areas 10-11 Solid, full metal expansion joint constructions Expansion joints for high load requirements .

Result: Total expansion of the pipe (44,49mm) must be absorbed by expansion joint that must have min. 44,49mm compression capacity. Using single Ayvaz pipe expansion joint with 50mm (-45/ 5) axial movement capacity is sufficient enough to absorb total pipe's expansion. Single Expansion Joint for The Buildings Up To 17 Floors

Source: Freely adapted from EJMA Source: Freely adapted from EN 14917 AXIAL Expansion joint selection AXIAL Expansion joint selection between the two fix points, the distance between the expansion joint and a fix point, the proximity of the first guide (G1), the spacing between the expansion joints thrusts on each side of the reducer.

12.2 Thermal Expansion Most materials expand when heated and contract when cooled. Thermal expansion is a consequence of the change in the dimensions of a body accompanying a change in temperature. 3 types of expansion: Linear expansion. area expansion, volume expansion In solid, all types of thermal expansion are occurred.

The Academic Phrasebank is a general resource for academic writers. It aims to provide the phraseological ‘nuts and bolts’ of academic writing organised according to the main sections of a research paper or dissertation. Other phrases are listed under the more general communicative functions of academic writing. The resource was designed primarily for academic and scientific writers who .