www.labtron.com info@labtron.com

Benchtop Dissolved oxygen meter LBDO-A10 Benchtop Dissolved oxygen meter LBDO-A10 is equipped with polarographic sensor to measure the dissolved oxygen content. The manual salinity & barometric pressure compensation helps in accurate measurement of dissolved oxygen. The system menu of dissolved oxygen meter can set 6 parameters which includes the number of calibration points, temperature units etc. Features Equipped with polarographic sensor Equipped with large backlit LCD display 1-2 points calibration using air saturated water & zero oxygen solution Manual salinity & barometric pressure compensation for better measurement of dissolved oxygen System menu allows setting the 6 optional parameters Automatic temperature compensation for accurate measured value over the entire range Auto hold function freezes stable, final readings for better viewing and recording Reset function automatically resumes all the settings to default mode Help message as an operational guide for quick beginning to the dissolved oxygen meter Applications Benchtop dissolved oxygen meter has applications in water & waste water management industry, environmental monitoring, surface ground water, research & development, education to detect content of dissolved oxygen.

Specifications Model no. LBDO-A10 Dissolved oxygen range 0.0 to 20.0 mg/L (or ppm) Dissolved oxygen accuracy 0.5 mg/L Resolution 0.1 mg/L Calibration points 1-2 points Sensor type Polarographic DO probe Temperature compensation range 0 to 400C, 32 to 1040F Barometric pressure correction 60.0 to 112.5kPa, 450-850 mmHg Salinity correction 0-35 g/L % of saturation of oxygen range 0.0 to 200.0% % of saturation of oxygen accuracy 10% F.S. % of saturation of oxygen resolution 0.1% System menu Allows setting of 6 parameters Data hold function Manual or automatic endpoint detection Manual or automatic (180 minutes) Reset function Yes Display Backlit LCD (135 75 mm) Connector 6 pin mini plug Power DC9V, use of SC adapter, AC220V/50Hz Dimension (L*W*H) 210 205 75 mm Weight 1.5 kg Standard accessories: Dissolved oxygen probe Dissolved oxygen Electrolyte solution Membrane cap DC9V power adapter Optional accessories: Polarographic sensor 30mL electrolyte solution per bottle Membrane cap

Benchtop Dissolved oxygen meter LBDO-A11 Benchtop Dissolved oxygen meter LBDO-A11 is equipped with polarographic sensor to measure the dissolved oxygen content. The manual salinity & barometric pressure compensation helps in accurate measurement of dissolved oxygen. The system menu of dissolved oxygen meter can set 9 parameters such as stability conditions, calibration points etc. This meter stores and recalls up to 500 sets of data & data is transferrable to PC via USB interface. Features Equipped with polarographic sensor Equipped with large backlit LCD display 1-2 points calibration using air saturated water & zero oxygen solution Manual salinity & barometric pressure compensation for better measurement of dissolved oxygen System menu allows setting the 9 optional parameters Automatic temperature compensation for accurate measured value over the entire range Auto hold function freezes stable, final readings for better viewing and recording Built-in real time clock stamps store data to meet GLP standard Expanded memory stores and recalls up to 500 readings Reset function automatically resumes all the settings to default mode Help message as an operational guide for quick beginning to the dissolved oxygen meter Applications Benchtop dissolved oxygen meter has applications in water & waste water management industry, environmental monitoring, surface ground water, research & development, education to detect content of dissolved oxygen.

Specifications LBDO-A11 Model no. Dissolved oxygen range 0.0-20.0 mg/L (or ppm) Dissolved oxygen accuracy 0.2 mg/L Resolution 0.01 mg/L Calibration points 1-2 points Sensor type Polarographic DO probe Temperature compensation range 0 to 500C, 32 to 1220F Barometric pressure correction 60.0 to 112.5kPa, 450 to 850 mmHg Salinity correction 0-50 g/L % of saturation of oxygen range 0.0-200.0% % of saturation of oxygen accuracy 2.0% F.S. % of saturation of oxygen resolution 0.1, 1% System menu Allows setting of 9 parameters Data hold function Manual or automatic endpoint detection Manual or automatic (10, 20, 30 minutes) Reset function Yes Memory Stores up to 50 data sets Output USB communication interface Display Backlit LCD (130 110 mm) Connector 6 pin mini plug Calibration due 0 to 31 days Stability conditions Low or high Power DC5V, use of AC adapter, AC220V/50Hz Dimension (L*W*H) 210 188 60 mm Weight 1.5 kg Standard accessories: Dissolved oxygen probe Dissolved oxygen Electrolyte solution Membrane cap DC9V power adapter Optional accessories: Polarographic sensor 30mL electrolyte solution per bottle Membrane cap

Benchtop Dissolved oxygen meter LBDO-AII is equipped With polarographic sensor to measure the dissolved oxygen content. The manua salinity Sbarometric pressure compen sation helps in accurate measurement Of dissolved oxygen. The system menu Of dissolved oxygen meter can set 9 parameters such as stability conditions, calibration points etc. This

Related Documents:

FreeZone Freeze Dryers Features & Benefits 7 Build a Freeze Dry System 8 Selection Guide 10 2.5 Liter Benchtop 12 4.5 Liter Benchtop 14 8 Liter Benchtop 16 6, 12 & 18 Liter Console 18 FreeZone Legacy Freeze Dryers 2.5 Liter Benchtop 21 6 Liter Benchtop 22 Dry Ice Benchtop Freeze Dryer 23 Tray Dryers FreeZone Legacy Triad Freeze .

dissolved oxygen. Dissolved oxygen is reported as milligrams per liter (mg/L), parts per million (ppm), or as percent air saturation (% Sat). 1 mg/L is equal to 1 ppm. 100% air saturation refers to the maximum amount of dissolved oxygen that a sample of water can hold at equilibrium. There are several common methods for determining dissolved .

Thermo Scientific Orion Star A214 Benchtop and Star A324 Portable pH/ISE Meter Reference Guide 5 Connecting Electrode Arm to an Orion Star A Series Benchtop Meter Orion Star A series benchtop meters include an electrode arm that can be attached to either side of the meter. 6OQBDL UIF FMFDUSPEF BSN BOE CBTF 2.

Dissolved Oxygen Bench Meter. HI2400. Instruction Manual. www.hannainst.com. 2 Dear Customer, Thank you for choosing a Hanna Instruments product. . For accurate Dissolved Oxygen measurements, a water movement of . 0.3 m/s is required. This is to ensure that the oxygen ‑depleted membrane

dissolved oxygen levels well above 5 mg/L. Low dissolved oxygen events occur in all the tidal rivers. In August 2015-the most recent year we have data-most low dissolved oxygen events in the tidal rivers lasted between two and six hours. PREP Goal Reduce nutrient loads to the estuaries and the ocean so that adverse, nutrient-related effects do

milliliters of dissolved oxygen in a liter of water. The concentration of the oxygen in aquatic environments is a very important component of water quality. At 20 C oxygen diffuses 300,000 times faster in air than in water, making the distribution of oxygen in air relatively uniform. Spatial distribution of oxygen in water, on the other hand, can

Factors Affecting Dissolved Oxygen Concentrations in Water Abiotic Factors The amount of oxygen that can be dissolved in water depends on several factors, including: water temperature, the amount of dissolved salts present in the water (salinity), and atmospheric pressure (Tables 1 and 2). On a relative scale, the amount of

This standard employs the principles of API 650; however, storage tank owner/operators, based on consideration of specific construction and operating details, may apply this standard to any steel tank constructed in accordance with a tank specification. This standard is intended for use by organizations that maintain or have access to engineering and inspection personnel technically trained .